Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Fetal Diagn Ther ; 51(2): 184-190, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38198774

RESUMO

INTRODUCTION: Randomized controlled trials found that fetoscopic endoluminal tracheal occlusion (FETO) resulted in increased fetal lung volume and improved survival for infants with isolated, severe left-sided congenital diaphragmatic hernia (CDH). The delivery room resuscitation of these infants is particularly unique, and the specific delivery room events are largely unknown. The objective of this study was to compare the delivery room resuscitation of infants treated with FETO to standard of care (SOC) and describe lessons learned. METHODS: Retrospective single-center cohort study of infants treated with FETO compared to infants who met FETO criteria during the same period but who received SOC. RESULTS: FETO infants were more likely to be born prematurely with 8/12 infants born <35 weeks gestational age compared to 3/35 SOC infants. There were 5 infants who required emergent balloon removal (2 ex utero intrapartum treatment and 3 tracheoscopic removal on placental bypass with delayed cord clamping) and 7 with prenatal balloon removal. Surfactant was administered in 6/12 FETO (50%) infants compared to 2/35 (6%) in the SOC group. Extracorporeal membrane oxygenation use was lower at 25% and survival was higher at 92% compared to 60% and 71% in the SOC infants, respectively. CONCLUSION: The delivery room resuscitation of infants treated with FETO requires thoughtful preparation with an experienced multidisciplinary team. Given increased survival, FETO should be offered to infants with severe isolated left-sided CDH, but only in high-volume centers with the experience and capability of removing the balloon, emergently if needed. The neonatal clinical team must be skilled in managing the unique postnatal physiology inherent to FETO where effective interdisciplinary teamwork is essential. Empiric and immediate surfactant administration should be considered in all FETO infants to lavage thick airway secretions, particularly those delivered <48 h after balloon removal.


Assuntos
Oclusão com Balão , Hérnias Diafragmáticas Congênitas , Feminino , Humanos , Lactente , Recém-Nascido , Gravidez , Oclusão com Balão/métodos , Estudos de Coortes , Salas de Parto , Fetoscopia/métodos , Hérnias Diafragmáticas Congênitas/cirurgia , Placenta , Estudos Retrospectivos , Tensoativos , Traqueia/cirurgia
2.
Laryngoscope ; 134(5): 2444-2448, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-37983867

RESUMO

OBJECTIVE: Surgical plume has known potential occupational health hazards. This study compares nanoparticle concentrations in surgical plumes generated between different pediatric tonsillectomy surgical techniques and assesses the efficacy of mitigation measures. METHODS: This is a cross-sectional study performed at a tertiary care academic center. Extracapsular or intracapsular tonsillectomy was performed in 60 patients using four techniques and in 10 additional patients using mitigation measures. Two nanoparticle counters were used to measure particulate concentrations: CPC™ and DiSCmini™. Tonsillectomy techniques included: (1) microdebrider (MD), (2) Bovie with manual suctioning by an assistant (B), (3) Bovie with built-in smoke evacuation system (BS), and (4) Coblator™ (CB). An additional Yankauer suction was used in the mitigation groups (BSY) and (CBY). Comparative analysis was performed using one-way ANOVA on ranks and pairwise comparisons between the groups. RESULTS: The mean concentrations (particles/cm3) and coefficient of variants for the DiSCmini particulate counter were MD: 5140 (1.6), B: 30700 (1.5), BS: 25001 (0.8), CB: 54814 (1.7), CBY: 2395 (1.3) and BSY: 11552 (1.0). Mean concentrations for the CPC particulate counter were MD: 1223 (1.4), B: 3405 (0.7), BS: 5002 (0.9), CB: 13273 (1.0), CBY: 1048 (1.2) and BSY: 3046 (0.6). The lowest mean concentrations were noted in cases using MD and the highest in cases using CB. However, after mitigation, CBY had the lowest overall levels. CONCLUSION: Tonsillectomy technique does impact the levels of nanoparticles emitted within the surgical plume, which may present an occupational hazard for operating room personnel. LEVEL OF EVIDENCE: 3 Laryngoscope, 134:2444-2448, 2024.


Assuntos
Tonsilectomia , Criança , Humanos , Tonsilectomia/métodos , Estudos Transversais , Adenoidectomia , Eletrocirurgia , Eletrocoagulação/métodos , Poeira
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA