Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
J Med Imaging Radiat Sci ; 54(4): 611-619, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37718151

RESUMO

BACKGROUND: Time is a valuable commodity that impacts hospital flow, patient experience and economic resources. This study aims to identify factors that affect daily treatment time over a course of radiation therapy (RT) in patients who underwent adjuvant breast RT. METHODS: In all adjuvant breast/chestwall RT patients treated from October 2017 to May 2018, daily set-up, beam delivery time, and overall treatment times were collected. A multivariable linear regression analysis was conducted to identify significant predictive factors related to treatment time. A general linear regression model was used to determine whether there was a learning curve effect throughout the course of treatment that decreased treatment time as patient and staff familiarity with the treatment procedure increased. RESULTS: A total of 567 patients were included with a median age of 61 years. The average overall treatment time for 2-field and 4-field RT was 8.3 (SD 2.4) and 13.1 (SD 5.6) minutes, respectively. Factors that significantly increased overall treatment times in patients prescribed 2-field RT were: bilateral techniques, breath-hold (BH) techniques, prone techniques (PR), reverse decubitus techniques (RD), wide tangents techniques, the use of bolus and number of segments delivered. (p < 0.05). Factors that significantly increased overall treatment times in patients who received 3-field and 4-field RT were: wide tangents volumes, a higher number of monitor units (MUs), bilateral techniques and BH techniques (p < 0.05). Older patients (≥60) who underwent 3-field and 4-field RT demonstrated a statistically significant increase in set-up time (p < 0.0001). Overall treatment time decreased from 10.0 to 9.3 min over the course of treatment, suggesting a minor learning curve (p = 0.009). CONCLUSION: The use of bilateral RT, BH, PR, RD, wide tangents, bolus, increasing treatment volumes, and increasing plan complexity were associated with increased treatment times. Future research should quantify the impact of other factors (BMI, mobility, patient care assessments, and imaging protocols) and utility of technological tools (time-predicting models, machine learning tools, and operations research models) on treatment time to optimize RT scheduling and improve resource management.


Assuntos
Neoplasias , Humanos , Pessoa de Meia-Idade , Ontário , Radioterapia Adjuvante , Suspensão da Respiração , Fatores de Tempo
2.
CJC Open ; 3(12): 1438-1443, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34993455

RESUMO

BACKGROUND: Radiation therapy (RT) is a standard cancer treatment modality, and an increasing number of patients with cardiac implantable electronic devices (CIEDs) are being referred for RT. The goals of this study were as follows: (i) to determine the incidence of CIED malfunction following RT; (ii) to characterize the various types of malfunctions that occur; and (iii) to identify risk factors associated with CIED malfunction following RT. METHODS: A retrospective study of patients with CIEDs who received RT between 2007 and 2018 at 4 Canadian centres (Sunnybrook Health Sciences Centre, Kingston General Hospital, Hamilton Health Sciences Centre, and University of Ottawa Heart Institute) was conducted. Patients underwent CIED interrogation after completion of RT, to assess for late damage to the CIEDs. Data on demographics, devices, and RT were compared for the primary outcome of device malfunction. RESULTS: Of 1041 patients with CIEDs who received RT, 811 patients with complete data were included. Device malfunctions occurred in 32 of 811 patients (4%). The most common device malfunctions were reduced ventricular/atrial sensing (in 13 of 32 [41%]), an increase in lead threshold (in 9 of 32 [22%]), lead noise (in 5 of 32 [16%]), and electrical reset (in 2 of 32 [6%]). Higher beam energy (≥ 10 MV) was associated with malfunction (P < 0.0001). Radiation dose was not significantly different between the malfunction and non-malfunction groups (58.3 cGy vs 65 cGy, respectively, P = 0.71). CONCLUSIONS: Although RT-induced CIED malfunctions are rare (occurring in 4% of patients with a CIED who undergo RT), collaborative efforts between radiation oncologists and cardiac rhythm device clinics to optimize CIED monitoring are needed, to detect and manage CIED malfunctions. Malfunctions are more common in patients receiving higher-beam energy ( ≥ 10 MV ) RT.


CONTEXTE: La radiothérapie (RT) est une modalité standard de traitement du cancer, et un nombre croissant de patients porteurs de dispositifs cardiaques électroniques implantables (DCEI) doivent recevoir un traitement de RT. Les objectifs de cette étude étaient les suivants : (i) déterminer l'incidence d'une défaillance du DCEI après une RT; (ii) caractériser les différents types de défaillances qui se produisent; (iii) déterminer les facteurs de risque associés à la défaillance du DCEI après une RT. MÉTHODOLOGIE: Une étude rétrospective des patients avec un DCEI ayant reçu une RT entre 2007 et 2018 dans quatre centres canadiens (Sunnybrook Health Sciences Centre, Kingston General Hospital, Hamilton Health Sciences Centre et Institut de cardiologie de l'Université d'Ottawa) a été menée. Le DCEI des patients a été interrogé après la fin de la RT, pour en évaluer les dommages tardifs. Les données sur les caractéristiques démographiques, les dispositifs et la RT ont été comparées pour le paramètre d'évaluation principal, soit la défaillance du dispositif. RÉSULTATS: Sur les 1 041 patients avec un DCEI ayant reçu une RT, 811 patients avec des données complètes ont été inclus. Des défaillances du dispositif sont survenues chez 32 des 811 patients (4 %). Les défaillances les plus fréquentes du dispositif étaient une détection ventriculaire/atriale réduite (chez 13 des 32 patients [41 %]), une augmentation du seuil de la sonde (chez 9 des 32 patients [22 %]), un bruit provenant de la sonde (chez 5 des 32 patients [16 %]) et une réinitialisation électrique (chez 2 des 32 patients [6 %]). Une énergie de faisceau plus élevée (≥ 10 MV) était associée à une défaillance (p < 0,0001). La dose de rayonnement ne présentait pas de différence significative entre le groupe où une défaillance a été constatée et l'autre groupe (58,3 cGy vs 65 cGy, respectivement, p = 0,71). CONCLUSIONS: Bien que les défaillances du DCEI causées par la RT soient rares (survenant chez 4 % des patients avec un DCEI qui subissent une RT), une collaboration est nécessaire entre les radio-oncologues et les cliniques de dispositifs de gestion du rythme cardiaque, afin d'optimiser la surveillance du DCEI et de détecter et de gérer ces défaillances. Les défaillances sont plus fréquentes chez les patients recevant une énergie de faisceau plus élevée au moment de la RT ( ≥ 10 MV ) .

3.
Asian J Nanosci Mater ; 4(1): 53-66, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38234577

RESUMO

We present a report regarding the cytotoxic effects of iron-based magnetic nanoparticles conjugated with fluorodeoxyglucose (FDG-mNPs) on the viability of NCI-H727 and SH-SY5Y cancer cells. MTT assays were performed to determine cell viability in treated cancer cells grown under standard 2D culture conditions. FDG-mNP concentrations of 0.075 mg/mL, 0.15 mg/mL, and 0.3 mg/mL decreased mean cell viability of NCI-H727 cells to 92.5%, 82.9%, and 75% respectively. FDG-mNPs was also shown to have a detrimental effect on the viability of SY5Y cells: a decrease of 5.7%, 18.6%, and 36.4% was found for SY5Y cells treated with 0.075 mg/mL, 0.15 mg/mL, and 0.3 mg/mL concentrations of FDG-mNPs, respectively. When NCI-H727 and SH-SY5Y cancer cells were grown as 3D spheroids, morphology was visibly changed and the number of viable cells was decerased in spheroids treated with FDG-mNPs compared with untreated spheroids. The results of our study demonstrated that FDG-mNP has toxic effects on NCI-H7272 and SY5Y cancer cells, and we conclude that conjugated FDG-mNPs are promising in the development of clinical applications for the destruction of cancer cells.

4.
Asian J Nanosci Mater ; 4(3): 229-239, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38192303

RESUMO

Iron nanoparticles (MNPs) are known to induce membrane damage and apoptosis of cancer cells. In our study we determined whether FDG coupled with iron oxide magnetic nanoparticles can exert the same destructive effect on cancer cells. This research study presents data involving NIC-H727 human lung, bronchus epithelial cells exposed to conjugated fluorodeoxyglucose conjugated with iron-oxide magnetic nanoparticles and indocyanine green (ICG) dye (FDG-MNP-ICG), with and without the application of a magnetic field. Cell viability inferred from MTT assay revealed that FDG-MNPs had no significant toxicity towards noncancerous NIC-H727 human lung, bronchus epithelial cells. However, percentage cell death was much higher using a magnetic field, for the concentration of FDG-MNP-ICC used in our experiments. Magnetic field was able to destroy cells containing MNPs, while MNPs alone had significantly lower effects. Additionally, MNPs alone in these low concentrations had less adverse effects on healthy (non-target) cells.

5.
J Med Imaging Radiat Sci ; 51(3): 379-393, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32362536

RESUMO

INTRODUCTION: Breast cancer radiotherapy (RT) can increase the risk of cardiac disease with increasing dose; as such, reducing excessive dosage to the heart is a concern for clinicians. The purpose of the present study was to assess mean heart dose (MHD) in patients with breast cancer receiving RT, where it was hypothesized that MHD decreased over time. METHODS: Patients planned for adjuvant unilateral whole breast/chest wall RT from 2011 to 2018 were included for a retrospective chart-review at a single-institution, academic center. MHD (Gy) was summarized by laterality, fractionation, and heart-sparing techniques. RESULTS: A total of 4,687 patients were included. The median MHD for left-sided conventional RT (50 Gy in 25 fractions) was 2.16 Gy across all years, decreasing until 2015 and increasing after. Median MHD for left-sided hypofractionated RT (42.6 Gy in 16 fractions) was 1.47 Gy, also decreasing until 2015 and increasing after. The increase in MHD after 2015 was attributed to a significant increase in the use of wide tangents (including internal mammary chain) after 2015 (P < .0001). Several treatment factors were associated with higher MHD in both right- and left-sided cancers, including locoregional RT, high tangents, wide tangents, bolus, heart shielding, treatment to the chest wall, higher volume of tissue irradiated by tangential fields, higher baseline breast separation values, and smaller heart volume. After adjusting for laterality and fractionation in the multivariate analysis, locoregional RT, wide tangents, heart shielding, boost, treatment to the chest wall, higher volume of tissue irradiated by tangential fields, higher baseline breast separation, and lower heart volume were significantly associated with higher MHD (P < .0001). DISCUSSION/CONCLUSIONS: MHD should be considered when determining the most appropriate RT techniques for both right- and left-sided cancers as higher MHD was significantly associated with various treatment techniques and patient factors.


Assuntos
Fracionamento da Dose de Radiação , Coração/efeitos da radiação , Órgãos em Risco , Neoplasias Unilaterais da Mama/radioterapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Cardiopatias/prevenção & controle , Humanos , Pessoa de Meia-Idade , Hipofracionamento da Dose de Radiação , Lesões por Radiação/prevenção & controle , Proteção Radiológica , Radioterapia Adjuvante , Estudos Retrospectivos , Adulto Jovem
6.
Blood Cancer J ; 10(2): 20, 2020 02 25.
Artigo em Inglês | MEDLINE | ID: mdl-32098948

RESUMO

In patients with immunoglobulin light-chain (AL) amyloidosis, depth of hematologic response correlates with both organ response and overall survival. Our group has demonstrated that screening with a matrix-assisted laser desorption/ionization-time-of-flight (TOF) mass spectrometry (MS) is a quick, sensitive, and accurate means to diagnose and monitor the serum of patients with plasma cell disorders. Microflow liquid chromatography coupled with electrospray ionization and quadrupole TOF MS adds further sensitivity. We identified 33 patients with AL amyloidosis who achieved amyloid complete hematologic response, who also had negative bone marrow by six-color flow cytometry, and who had paired serum samples to test by MS. These samples were subjected to blood MS. Four patients (12%) were found to have residual disease by these techniques. The presence of residual disease by MS was associated with a poorer time to progression (at 50 months 75% versus 13%, p = 0.003). MS of the blood out-performed serum and urine immunofixation, the serum immunoglobulin free light chain, and six-color flow cytometry of the bone marrow in detecting residual disease. Additional studies that include urine MS and next-generation techniques to detect clonal plasma cells in the bone marrow will further elucidate the full potential of this technique.


Assuntos
Biomarcadores Tumorais/sangue , Cromatografia Líquida/métodos , Amiloidose de Cadeia Leve de Imunoglobulina/diagnóstico , Espectrometria de Massas/métodos , Neoplasia Residual/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Amiloidose de Cadeia Leve de Imunoglobulina/sangue , Masculino , Pessoa de Meia-Idade , Neoplasia Residual/sangue , Prognóstico , Estudos Retrospectivos , Taxa de Sobrevida
7.
J Med Imaging Radiat Sci ; 50(1): 5-11, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30777248

RESUMO

INTRODUCTION: Health care services use surveys to assess patient satisfaction and identify areas for improvement. While it is important to assess patient satisfaction to ensure their needs are met, lengthy questionnaires with closed-ended questions often focus on areas that may be considered important by institutions rather than patients. Recently, focus has shifted toward patient and caregiver experience, which institutions address via appreciative inquiry. The aim of this initiative was the development of a patient experience survey (PES) for radiation therapy patients and caregivers which would allow them to express their opinions and priorities. This patient feedback would then be addressed through quality improvement (QI) projects geared toward improving the overall patient and caregiver experience in radiation therapy. METHODS: A three-question minute survey was developed for use as a PES in the radiation therapy department of an academic oncology program located in a large metropolitan area. Feedback was obtained from patient education and person-centred care experts, as well as 10 radiation therapy patients. All feedback was incorporated to create the final PES; respondents rated their agreement on a five-point Likert scale with the statement "My overall experience in Radiation Therapy was great" and two open-ended questions allowed them to highlight departmental strengths and areas for improvement. An initial 3-month pilot was conducted where PESs were available on a self-serve basis to patients and caregivers in waiting areas and at radiation therapy treatment units. All responses were anonymous and completed surveys were returned via drop boxes. Descriptive statistics and thematic analysis were used to analyse responses. RESULTS: A total of 86 surveys were returned. Of those, 80 (93%) responded to the Likert scale question with 83% agreeing or strongly agreeing that their experience in radiation therapy was great. Several strengths were identified by respondents including teamwork, professionalism, and knowledge. Areas identified for improvement included management of appointment delays and communication of delays to patients, as well as environmental improvements. CONCLUSIONS: Although most respondents reported a favourable experience, this pilot demonstrated the minute survey can identify areas for improvement that can be addressed through QI. Including the patient perspective in QI is evidenced to enhance its outcome and aligns with institutional, provincial, and national strategic goals of improving the quality of cancer care through patient engagement.


Assuntos
Satisfação do Paciente , Melhoria de Qualidade , Radioterapia/normas , Inquéritos e Questionários , Humanos
8.
Pract Radiat Oncol ; 8(2): 116-122, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29329996

RESUMO

INTRODUCTION: Radiation therapy is a standard treatment option for prostate cancer. With growing use of escalated doses and tighter margins, procedures to limit rectal size variation are needed to reduce prostate motion, increase treatment accuracy, and minimize rectal toxicity. This prospective study was done to determine whether the introduction of an antiflatulent medication would decrease rectal distention at computed tomography (CT) simulation and throughout a course of radiation therapy. METHODS AND MATERIALS: Patients undergoing a radical course of radiation therapy to the prostate/prostate bed were eligible to participate. Participants were randomly assigned to the intervention arm (antiflatulent medication) or the control arm (no medication). For each participant, the number of CT simulation rescans was recorded. Rectal diameters were measured on CT simulation and treatment cone beam CT scans. Acute rectal toxicities were assessed at baseline and weekly using National Cancer Institute Common Terminology Criteria for Adverse Events (NCI CTCAE), version 4.0. A χ2 analysis was used to compare the number of participants requiring a rescan in each study arm. Change in rectal diameter over time was assessed using repeated measures analysis of variance. RESULTS: A total of 78 patients participated, with equal numbers assigned to each study arm. There was no significant difference between arms in the number of participants requiring a CT simulation rescan (P = .5551). There was no significant variation in rectal diameter between arms (P = .8999); however, there was a significant effect of time (P = .0017) and a significant interaction effect between study arm and time on rectal diameter (P = .0141). No acute rectal toxicities above grade 2 were reported. CONCLUSIONS: The addition of antiflatulent medication did not affect the frequency of CT simulation rescans. Both time and the interaction between study arm and time had a statistically significant effect on rectal diameter, although neither finding was clinically significant. Instead, standardized bowel preparation education developed for this study may have been sufficient to limit rectal size variation.


Assuntos
Antiespumantes/uso terapêutico , Neoplasias da Próstata/tratamento farmacológico , Neoplasias da Próstata/radioterapia , Radioterapia Guiada por Imagem/métodos , Idoso , Antiespumantes/farmacologia , Humanos , Masculino
9.
J Med Imaging Radiat Sci ; 49(2): 136-144, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32074031

RESUMO

BACKGROUND: Radiation oncology Care Plans are predefined procedures that outline a patient's radiation therapy (RT) path of care. Care Plans allow for standardization of centre-specific procedures and workflows, thereby laying the foundation for autoforwarding of RT tasks and mandatory information capture via assessment forms. However, the integration of Care Plans at a large centre with established workflows is challenging and requires a redesign of numerous processes across all disciplines and site groups in an electronic data management system. Here, we describe the development and implementation experience of IQ Script enabled MOSAIQ Care Plans at the Odette Cancer Centre between summer 2014 and summer 2016. METHODS: A core Care Plan development group was formed that included membership from key stakeholders in RT, oncology, and physics. Care Plan pre-development planning was performed in three phases that included (1) collection and organization of all site and technique-specific protocols and procedures, (2) creation of workflow process maps and intimate discussions with potential stakeholders regarding automation and information capture, and (3) integration of design concepts into the IQ Script enabled Care Plans authoring framework. Following pre-planning, IQ Script enabled Care Plans authoring was performed on a test server with standardized naming conventions and tracking sheets for all IQ scripting triggers and events. Care Plan workflows were tested, and a senior therapist transferred individual Care Plans to the production server. Care Plans were then released gradually over a 1-year period, starting with pilot sites with the highest site group member buy-in. A post-implementation survey was performed to assess end-user feedback. SUMMARY AND CONCLUSIONS: IQ Script enabled Care Plans resulted in standardization of clinical processes including patient booking, autoforwarding of RT tasks, and mandatory information capture. Survey results indicated stakeholder satisfaction with the implementation process. Comments for improving Care Plans included changes to computed tomography simulation assessment forms for more robust capture of dose prescription and fractionation. Overall, the transition to Care Plans allowed our center to enhance information documentation, streamline our RT workflow, and ultimately improve the accuracy and efficiency of patient care. For the radiation oncologist, the use of Care Plans has also eliminated the use of another software system in which to request planning.

10.
J Cancer Educ ; 33(3): 551-556, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-27526692

RESUMO

The purpose of this study is to determine the effectiveness of multimedia educational tools to improve CT planning preparation for intensity modulated radiotherapy (IMRT) for prostate cancer. Many patients are not prepared when given verbal preparation instructions to have a full bladder and empty rectum for their IMRT and require being rescanned, which results in additional costs for the patient and the hospital. A pamphlet and video outlining the proper preparation for prostate IMRT was created to decrease additional scans and the associated costs, while increasing patient satisfaction. A controlled, randomized experimental group study was conducted to examine the effectiveness of the multimedia tools (the video and the pamphlet), as compared to the pamphlet only, in preparing patients for their planning CT appointment. We found no statistical difference between the multimedia group and the pamphlet group in patients' preparedness for their appointments and the rescanning rate. However, patients in the multimedia group indicated that they felt more prepared about their treatment after watching the video and stated that they would recommend the video to other patients with prostate cancer. Furthermore, patients who had to wait longer for their planning CT appointment felt less prepared by the materials than those with a shorter wait time. We recommend reducing wait times between appointments as much as possible to increase patients' preparedness for the planning CT. We conclude that providing multimedia treatment information and minimizing wait times increases patients' feelings of preparedness leading to a more positive treatment experience and reducing costly rescans. TRIAL REGISTRATION: ClinicalTrials.gov NCT02410291.


Assuntos
Multimídia , Educação de Pacientes como Assunto/métodos , Neoplasias da Próstata/radioterapia , Radioterapia de Intensidade Modulada/métodos , Idoso , Idoso de 80 Anos ou mais , Humanos , Masculino , Pessoa de Meia-Idade , Folhetos , Satisfação do Paciente , Gravação de Videoteipe
11.
Radiother Oncol ; 108(1): 24-31, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23849174

RESUMO

BACKGROUND AND PURPOSE: We previously reported a therapeutic strategy comprising replication-defective NIS-expressing adenovirus combined with radioiodide, external beam radiotherapy (EBRT) and DNA repair inhibition. We have now evaluated NIS-expressing oncolytic measles virus (MV-NIS) combined with NIS-guided radioiodide, EBRT and specific checkpoint kinase 1 (Chk1) inhibition in head and neck and colorectal models. MATERIALS AND METHODS: Anti-proliferative/cytotoxic effects of individual agents and their combinations were measured by MTS, clonogenic and Western analysis. Viral gene expression was measured by radioisotope uptake and replication by one-step growth curves. Potential synergistic interactions were tested in vitro by Bliss independence analysis and in in vivo therapeutic studies. RESULTS: EBRT and MV-NIS were synergistic in vitro. Furthermore, EBRT increased NIS expression in infected cells. SAR-020106 was synergistic with EBRT, but also with MV-NIS in HN5 cells. MV-NIS mediated (131)I-induced cytotoxicity in HN5 and HCT116 cells and, in the latter, this was enhanced by SAR-020106. In vivo studies confirmed that MV-NIS, EBRT and Chk1 inhibition were effective in HCT116 xenografts. The quadruplet regimen of MV-NIS, virally-directed (131)I, EBRT and SAR-020106 had significant anti-tumour activity in HCT116 xenografts. CONCLUSION: This study strongly supports translational and clinical research on MV-NIS combined with radiation therapy and radiosensitising agents.


Assuntos
Neoplasias Colorretais/terapia , Neoplasias de Cabeça e Pescoço/terapia , Radioisótopos do Iodo/uso terapêutico , Isoquinolinas/uso terapêutico , Vírus do Sarampo/fisiologia , Terapia Viral Oncolítica , Inibidores de Proteínas Quinases/uso terapêutico , Proteínas Quinases/fisiologia , Pirazinas/uso terapêutico , Radiossensibilizantes/uso terapêutico , Animais , Linhagem Celular Tumoral , Quinase 1 do Ponto de Checagem , Terapia Combinada , Humanos , Camundongos , Simportadores/genética , Replicação Viral , Ensaios Antitumorais Modelo de Xenoenxerto
13.
Anal Chem ; 78(4): 1071-84, 2006 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-16478097

RESUMO

Correct identification of a peptide sequence from MS/MS data is still a challenging research problem, particularly in proteomic analyses of higher eukaryotes where protein databases are large. The scoring methods of search programs often generate cases where incorrect peptide sequences score higher than correct peptide sequences (referred to as distraction). Because smaller databases yield less distraction and better discrimination between correct and incorrect assignments, we developed a method for editing a peptide-centric database (PC-DB) to remove unlikely sequences and strategies for enabling search programs to utilize this peptide database. Rules for unlikely missed cleavage and nontryptic proteolysis products were identified by data mining 11 849 high-confidence peptide assignments. We also evaluated ion exchange chromatographic behavior as an editing criterion to generate subset databases. When used to search a well-annotated test data set of MS/MS spectra, we found no loss of critical information using PC-DBs, validating the methods for generating and searching against the databases. On the other hand, improved confidence in peptide assignments was achieved for tryptic peptides, measured by changes in DeltaCN and RSP. Decreased distraction was also achieved, consistent with the 3-9-fold decrease in database size. Data mining identified a major class of common nonspecific proteolytic products corresponding to leucine aminopeptidase (LAP) cleavages. Large improvements in identifying LAP products were achieved using the PC-DB approach when compared with conventional searches against protein databases. These results demonstrate that peptide properties can be used to reduce database size, yielding improved accuracy and information capture due to reduced distraction, but with little loss of information compared to conventional protein database searches.


Assuntos
Bases de Dados de Proteínas , Armazenamento e Recuperação da Informação , Peptídeo Hidrolases/metabolismo , Peptídeos/química , Proteômica , Sequência de Aminoácidos , Humanos , Hidrólise , Espectrometria de Massas , Dados de Sequência Molecular , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA