Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Ann Vasc Surg ; 2024 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-39098723

RESUMO

BACKGROUND: Numerous studies have indicated that increased obesity in patients with established peripheral artery disease (PAD) is inversely associated with disease prognosis, a phenomenon coined as the "obesity paradox". A major cause of criticism in studies investigating the obesity paradox is the use of body mass index (BMI) as a surrogate marker in defining and quantifying the degree or severity of obesity. We conducted a retrospective review to verify whether the obesity paradox persists in patients with PAD when using body surface area (BSA) as an alternative anthropometric measure. METHODS: Patients undergoing surgery (open or endovascular) for PAD between January 2009 and March 2020 were identified from the Vascular Quality Initiative (VQI) national database. The association between BSA or BMI and risk of postoperative complications was evaluated using logistic regression and restricted cubic spline analysis, both of which were adjusted for demographic and comorbid risk predictors. When analyzing BSA and BMI as categorical variables, patients were grouped according to BSA quintiles and the World Health Organization (WHO) BMI categories. RESULTS: A total of 130,428 patients were included based on our eligibility criteria, of which 85,394 (65.5%) were men. Patients were typically hypertensive (87.8%), diabetic (50.4%), and overweight (63.0% over 25 kg/m2). Patients with a high BMI or BSA typically presented at a younger age and with greater preoperative administration of drugs (statin, angiotensin converting enzyme inhibitor, anticoagulant, and beta blocker). Our results indicate that BSA and BMI are inversely associated with postoperative risk of all-cause morbidity, mortality, and cardiac complications. This finding was displayed when analyzing BMI or BSA as a continuous variable or when indexing patients into BMI or BSA groups. CONCLUSIONS: Our data suggests that the obesity paradox persists in patients with PAD when using either BMI or BSA as anthropometric measures. Future studies with a prospective design and utilizing newer anthropometric indices should be conducted to fully verify the presence of this phenomenon.

2.
J Cardiothorac Vasc Anesth ; 38(7): 1460-1466, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38580474

RESUMO

OBJECTIVES: This study aimed to evaluate the accuracy of identifying the true aortic valve (AV) annulus using 2-dimensional (2D) echocardiography, with the goal of highlighting potential misidentification issues in clinical practice. DESIGN: An observational study employing 3-dimensional (3D) datasets to generate 2D images of the AV annulus for analysis. SETTING: The study was conducted in an academic medical center. PARTICIPANTS: Three-dimensional transesophageal echocardiography datasets were obtained from 11 patients with normal AV and aortic root anatomies undergoing coronary artery bypass surgery. Attending anesthesiologists certified by the National Board of Echocardiography (NBE) were approached subsequently to participate in this study. INTERVENTIONS: Two images per patient were generated from 3D datasets, reflecting the mid-esophageal long-axis view of the AV, a true AV annulus image, and an off-axis image. A survey was distributed to NBE-certified perioperative echocardiographers across 12 academic institutions to identify the true AV annulus from these images. MEASUREMENTS AND MAIN RESULTS: The survey, completed by 45 qualified respondents, revealed a significant misidentification rate of the true AV annulus, with only 36.8% of responses correctly identifying it. The rate of correct identification varied across image sets, with 44.4% of participants unable to correctly identify any true AV annulus image. CONCLUSIONS: The study highlighted the limitations of 2D echocardiography in accurately identifying the true AV annulus in complex 3D structures like the aortic root. The findings suggest a need for greater reliance on advanced imaging modalities, such as 3D echocardiography, to improve accuracy in clinical practice.


Assuntos
Valva Aórtica , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Ecocardiografia Tridimensional/métodos , Ecocardiografia Tridimensional/normas , Ecocardiografia Transesofagiana/métodos , Ecocardiografia Transesofagiana/normas , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Ecocardiografia/métodos , Ecocardiografia/normas
3.
J Cardiothorac Vasc Anesth ; 38(3): 755-770, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38220517

RESUMO

OBJECTIVES: To investigate whether implementation of a multidisciplinary protocol for ruptured abdominal aortic aneurysm (rAAA) management reduces rates of adverse complications. DESIGN: A retrospective before-after study. SETTING: A tertiary-care academic hospital. PARTICIPANTS: Adult patients who underwent open or endovascular rAAA repair; data were stratified into before-protocol implementation (group 1: 2015-2018) and after-protocol implementation (group 2: 2019-2022) groups. INTERVENTION: The protocol details the workflow for vascular surgery, anesthesia, emergency department, and operating room staff for a rAAA case; training was accomplished through yearly workshops. MEASUREMENTS AND MAIN RESULTS: The primary outcome was in-hospital mortality. Secondary outcomes included all-cause morbidity and other major complications. Differences in postoperative complication rates between groups were assessed using Pearson's χ2 test. Of the 77 patients included undergoing rAAA repair, 41 (53.2%) patients were in group 1, and 36 (46.8%) patients were in group 2. Patients in group 2 had a significantly shorter median time to incision (1.0 v 0.7 hours, p = 0.022) and total procedure time (180.0 v 160.5 minutes, p = 0.039) for both endovascular and open repair. After protocol implementation, patients undergoing endovascular repair exhibited significantly lower rates of mortality (46.2% v 20.0%, p = 0.048), all-cause morbidity (65.4% v 44.0%, p = 0.050), and renal complications (15.4% v 0.0%, p = 0.036); patients undergoing open repair for a rAAA exhibited significantly lower rates of mortality (53.3% v 27.3%, p = 0.018) and bowel ischemia (26.7% v 0.0%, p = 0.035). CONCLUSIONS: Implementation of a multidisciplinary protocol for the management of a rAAA may reduce rates of adverse complications and improve the quality of care.


Assuntos
Aneurisma da Aorta Abdominal , Ruptura Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Estudos Retrospectivos , Estudos Controlados Antes e Depois , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/métodos , Resultado do Tratamento , Ruptura Aórtica/cirurgia , Complicações Pós-Operatórias/etiologia , Fatores de Risco
4.
J Coll Physicians Surg Pak ; 29(1): 70-72, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30630574

RESUMO

Replacement of aortic valve with the pulmonary autograft is carried out through the Ross procedure due to its potential for growth, durability in pediatric population, and absence of anticoagulation. This case series reports the postoperative outcome of two technical variations of Ross procedure in eight patients who underwent surgery from January 2007 to December 2016. The dominant valvular hemodynamic indication was aortic regurgitation. The techniques employed for Ross procedure included free standing root replacement in six patients and modified root replacement with autograft stabilisation using Dacron interposition graft in two patients. Right ventricular outflow tract (RVOT) conduit reconstruction was achieved by utilisation of Contegra bio prosthesis in four patients; and use of manually constructed valved conduit comprising of PTFE (polytetrafluoroethelene) membrane and bovine pericardial tube in remaining four patients. There was no mortality and no re-intervention. The technical varieties of Ross procedure offer freedom from need of anti-coagulation, mortality, and RVOT conduit failure in younger adults.


Assuntos
Valva Aórtica/cirurgia , Bioprótese , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Artéria Pulmonar/transplante , Obstrução do Fluxo Ventricular Externo/cirurgia , Adolescente , Adulto , Implante de Prótese Vascular/efeitos adversos , Criança , Feminino , Doenças das Valvas Cardíacas/cirurgia , Humanos , Masculino , Transplante Homólogo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA