RESUMO
AIMS: The objective of this study was to determine the accuracy of right ventricular function (RVF) assessed by Cadmium Zinc Telluride ECG-gated SPECT equilibrium radionuclide angiocardiography (CZT-ERNA). METHODS AND RESULTS: Twenty-one consecutive patients with cardiomyopathy (aged 54 ± 19 years; 62% male) were included. RV ejection fraction (EF) and volumes were analyzed by CZT-ERNA and compared with values obtained by cardiac magnetic resonance imaging (CMR). Mean values were not different between CZT-ERNA and MRI for RVEF (48.1 ± 10.4% vs 50.8 ± 10.0%; P = .23). Significant correlations (P < .0001) were observed between CZT-ERNA and MRI for RVEF, RV end-diastolic volume, and end-systolic volume (r = 0.81, r = 0.93, and r = 0.96, respectively). Bland-Altman analysis showed a mean difference (bias) between CZT-ERNA and MRI for RVEF of -2.69% (95% CI - 5.35 to - 0.42) with good agreement between the 2 techniques (limits of agreement, -14.3 to 8.99). Intraobserver and interobserver reproducibility of RVF measured by CZT-ERNA was high. CONCLUSION: CZT-ERNA provides accurate, reproducible assessment of RVF and appears as a good alternative to cardiac magnetic resonance for the evaluation of the magnitude of RVF in patients with cardiomyopathy.
Assuntos
Cardiomiopatias , Imagem do Acúmulo Cardíaco de Comporta , Cádmio , Cardiomiopatias/diagnóstico por imagem , Eletrocardiografia , Feminino , Imagem do Acúmulo Cardíaco de Comporta/métodos , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Reprodutibilidade dos Testes , Volume Sistólico , Tomografia Computadorizada de Emissão de Fóton Único/métodos , ZincoRESUMO
BACKGROUND: Excessive ventilation (VÌE) and abnormal gas exchange during exercise are features of chronic thromboembolic pulmonary hypertension (CTEPH). In selected CTEPH patients, balloon pulmonary angioplasty (BPA) improves symptoms and exercise capacity. How BPA affects exercise hyperventilation and gas exchange is poorly understood. METHODS: In this longitudinal observational study, symptom-limited cardiopulmonary exercise tests and carbon monoxide lung diffusion (DLCO) were performed before and after BPA (interval, mean (SD): 3.1 (2.4) months) in 36 CTEPH patients without significant cardiac and/or pulmonary comorbidities. RESULTS: Peak work rate improved by 20% after BPA whilst VÌE at peak did not change despite improved ventilatory efficiency (lower VÌE with respect to CO2 output [VÌCO2]). At the highest identical work rate pre- and post-BPA (75 (30) watts), VÌE and alveolar-arterial oxygen gradient (P(Ai-a)O2) decreased by 17% and 19% after BPA, respectively. The physiological dead space fraction of tidal volume (VD/VT), calculated from measurements of arterial and mixed expired CO2, decreased by 20%. In the meantime, DLCO did not change. The best correlates of P(Ai-a)O2 measured at peak exercise were physiological VD/VT before BPA and DLCO after BPA. CONCLUSIONS: Ventilatory efficiency, physiological VD/VT, and pulmonary gas exchange improved after BPA. The fact that DLCO did not change suggests that the pulmonary capillary blood volume and probably the true alveolar dead space were unaffected by BPA. The correlation between DLCO measured before BPA and P(Ai-a)O2 measured after BPA suggests that DLCO may provide an easily accessible marker to predict the response to BPA in terms of pulmonary gas exchange.