Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Phys Med ; 114: 103136, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37769414

RESUMO

This study aimed to validate a bespoke 3D-printed phantom for use in quality assurance (QA) of a 6 degrees-of-freedom (6DoF) treatment couch. A novel phantom design comprising a main body with internal cube structures, was fabricated at five centres using Polylactic Acid (PLA) material, with an additional phantom produced incorporating a PLA-stone hybrid material. Correctional setup shifts were determined using image registration by 3D-3D matching of high HU cube structures between obtained cone-beam computer tomography (CBCT) images to reference CTs, containing cubes with fabricated rotational offsets of 3.5°, 1.5° and -2.5° in rotation, pitch, and roll, respectively. Average rotational setup shifts were obtained for each phantom. The reproducibility of 3D-printing was probed by comparing the internal cube size as well as Hounsfield Units between each of the uniquely produced phantoms. For the five PLA phantoms, the average rot, pitch and roll correctional differences from the fabricated offsets were -0.3 ± 0.2°, -0.2 ± 0.5° and 0.2 ± 0.3° respectively, and for the PLA hybrid these differences were -0.09 ± 0.14°, 0.30 ± 0.00° and 0.03 ± 0.10°. There was found to be no statistically significant difference in average cube size between the five PLA printed phantoms, with the significant difference (P < 0.05) in HU of one phantom compared to the others attributed to setup choice and material density. This work demonstrated the capability producing a novel 3D-printed 6DoF couch QA phantom design, at multiple centres, with each unique model capable of sub-degree couch correction.


Assuntos
Radiocirurgia , Radioterapia Guiada por Imagem , Reprodutibilidade dos Testes , Radiocirurgia/métodos , Imagens de Fantasmas , Impressão Tridimensional , Poliésteres
2.
Pediatr Blood Cancer ; 69(8): e29574, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35044080

RESUMO

BACKGROUND: Conservative surgery (CS) brachytherapy (BT) techniques for local therapy in bladder-prostate rhabdomyosarcoma (BP-RMS) seek to retain organ function. We report bladder function after high-dose rate (HDR) BT combined with targeted CS for any vesical component of BP-RMS. PROCEDURE: Prospective cohort of all BP-RMS patients between 2014 and 2019 receiving HDR-BT (iridium-192, 27.5 Gy in five fractions) with/without percutaneous endoscopic polypectomy (PEP) or partial cystectomy (PC). Functional assessment included frequency-volume chart, voided volumes, post-void residual, flow studies, continence status and ultrasound scanning; abnormalities triggered video urodynamics. RESULTS: Thirteen patients (10 male), aged 9 months to 4 years (median 23 months), presented with localised fusion-negative embryonal BP-RMS measuring 23-140 mm (median 43 mm) in cranio-caudal extent. After induction chemotherapy, local treatment consisted of PC+BT in three, PEP+BT in four and BT alone in six. At a median 3.5 years (range 21 months to 7 years) follow-up, all were alive without relapse. At a median age of 6 years (4-9 years), the median bladder capacity was 86% (47%-144%) of that expected for age, including 75% (74%-114%) after PC. Radiation dose to the bladder was associated with urinary urgency, but not bladder capacity or nocturnal enuresis. Complications occurred in two: one urethral stricture and one vesical decompensation in a patient with pre-existing high-grade vesico-ureteric reflux (VUR). The remaining patients were dry by day; five with anticholinergic medication for urinary urgency. Three patients are enuretic. CONCLUSIONS: Day-time dryness at a median 3.5 years after CS-HDR-BT was achieved in 92%, with 85% voiding urethrally, and 62% attaining day-and-night continence aged 4-9 years. We report reduced open surgery with minimally invasive percutaneous surgery, with HDR-BT or BT alone being suitable for many.


Assuntos
Braquiterapia , Neoplasias Pélvicas , Neoplasias da Próstata , Rabdomiossarcoma , Neoplasias da Bexiga Urinária , Braquiterapia/efeitos adversos , Braquiterapia/métodos , Criança , Humanos , Masculino , Recidiva Local de Neoplasia , Estudos Prospectivos , Próstata , Neoplasias da Próstata/tratamento farmacológico , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/cirurgia , Dosagem Radioterapêutica , Rabdomiossarcoma/radioterapia , Rabdomiossarcoma/cirurgia , Bexiga Urinária , Neoplasias da Bexiga Urinária/tratamento farmacológico , Neoplasias da Bexiga Urinária/radioterapia , Neoplasias da Bexiga Urinária/cirurgia
3.
Brachytherapy ; 20(2): 410-419, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33234407

RESUMO

PURPOSE: The purpose of this study was to compare low-dose-rate prostate brachytherapy treatment plans created using three retrospectively applied planning techniques with plans delivered to patients. METHODS AND MATERIALS: Treatment plans were created retrospectively on transrectal ultrasound (TRUS) scans for 26 patients. The technique dubbed 4D Brachytherapy was applied, using TRUS and MRI to obtain prostatic measurements required for the associated webBXT online nomogram. Using a patient's MRI scan to create a treatment plan involving loose seeds was also explored. Plans delivered to patients were made using an intraoperative loose seed TRUS-based planning technique. Prostate V100 (%), prostate V150 (%), prostate D90 (Gy), rectum D0.1cc (Gy), rectum D2cc (Gy), urethra D10 (%), urethra D30 (%), and prostate volumes were measured for each patient. Statistical analysis was used to assess and compare plans. RESULTS: Prostate volumes measured by TRUS and MRI were significantly different. Prostate volumes calculated by the webBXT online nomogram using TRUS- and MRI-based measurements were not significantly different. Compared with delivered plans, TRUS-based 4D Brachytherapy plans showed significantly lower rectum D0.1cc (Gy) values, MRI-based 4D Brachytherapy plans showed significantly higher prostate V100 (%) values and significantly lower rectum D0.1cc (Gy), urethra D10 (%), and urethra D30 (%) values, and loose seed MRI-based plans showed significantly lower prostate V100 (%), prostate D90 (Gy), rectum D0.1cc (Gy), rectum D2cc (Gy), urethra D10 (%), and urethra D30 (%) values. CONCLUSIONS: TRUS-based 4D Brachytherapy plans showed similar dosimetry to delivered plans; rectal dosimetry was superior. MRI can be integrated into the 4D Brachytherapy workflow. The webBXT online nomogram overestimates the required number of seeds.


Assuntos
Braquiterapia , Neoplasias da Próstata , Braquiterapia/métodos , Humanos , Masculino , Técnicas de Planejamento , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Reto/diagnóstico por imagem , Estudos Retrospectivos , Uretra
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA