Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Retin Cases Brief Rep ; 17(2): 89-92, 2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33939398

RESUMO

PURPOSE: To report the structural and functional outcomes of autologous neurosensory retinal transplantation for closure of refractory double full-thickness macular hole in a patient diagnosed with Alport syndrome. METHODS: Patient with previous pars plana vitrectomy and a failed macular hole surgery (internal limiting membrane removal) underwent pars plana vitrectomy and autologous neurosensory retinal flap transplantation with silicone oil tamponade. Follow-up was performed after one year. The anatomic outcomes were evaluated mainly by fundus examination, optical coherence tomography (OCT), and microperimetry (MAIA). The functional changes were evaluated comparing best-corrected visual acuities preoperative and 1 year after surgery. RESULTS: A 35-year-old man with progressive visual loss of two years of evolution presented a double full-thickness macular hole in the left eye. After retinal flap transplantation, the macular hole appeared successfully closed during the entire follow-up. Integration of both retinal flaps into the surrounding retina and regeneration of the external retinal layers were observed in optical coherence tomography. Best-corrected visual acuities improved from 20/200 preoperatively to 20/80 one-year postoperatively. CONCLUSION: Pars plana vitrectomy combined with autologous neurosensory retinal flap transplantation is an effective option to achieve the anatomic closure of recurrent double full-thickness macular hole and significant visual recovery in Alport syndrome.


Assuntos
Nefrite Hereditária , Perfurações Retinianas , Masculino , Humanos , Adulto , Perfurações Retinianas/cirurgia , Nefrite Hereditária/cirurgia , Tamponamento Interno/métodos , Acuidade Visual , Retina , Vitrectomia/métodos , Transplante Autólogo , Tomografia de Coerência Óptica/métodos , Estudos Retrospectivos
2.
Eur J Ophthalmol ; 31(2): NP136-NP140, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31530022

RESUMO

PURPOSE: To report a case of a unilateral spontaneous filtering bleb dissecting into the cornea in a patient with high myopia. CLINICAL CASE: A 33-year-old woman with high myopia (-18 D) presented with discomfort in the left eye. Ocular history included pars plana vitrectomy and cataract extraction and posterior chamber intraocular lens implantation in the left eye. Best-corrected visual acuity was 0.65 and intraocular pressure was 20 mmHg. Slit-lamp examination showed a filtering bleb in the upper-temporal quadrant, which extended and dissected the proximal cornea without affecting the visual axis. The morphology and content of the bleb was studied with anterior segment optical coherence tomography, which ruled out a corneal-scleral fistulization into the subconjunctival space. The spontaneous filtering bleb was resected surgically. Due to her high myopia, two strips of fascia lata were used to strengthen the area. In the postoperative period, a complete resection of the bleb was confirmed, without apparent leaking points and with a well-vascularized conjunctiva. No complications were noted. The patient maintained the same best-corrected visual acuity and intraocular pressure than before surgery. CONCLUSION: The formation of a spontaneous filtering bleb is a rare entity in patients with high myopia, whose risk increases due to their thinned sclerae. The risk is even greater if they have undergone ocular surgeries. Resection of the filtering bleb in our case halted the progression of the corneal dissection, therefore respecting the transparency of the visual axis and preserving visual acuity.


Assuntos
Doenças da Córnea , Oftalmopatias , Miopia Degenerativa , Malha Trabecular , Adulto , Feminino , Humanos , Extração de Catarata , Doenças da Córnea/etiologia , Oftalmopatias/diagnóstico por imagem , Oftalmopatias/etiologia , Oftalmopatias/cirurgia , Pressão Intraocular/fisiologia , Implante de Lente Intraocular , Miopia Degenerativa/complicações , Microscopia com Lâmpada de Fenda , Tomografia de Coerência Óptica/métodos , Malha Trabecular/diagnóstico por imagem , Malha Trabecular/patologia , Malha Trabecular/cirurgia , Acuidade Visual/fisiologia , Vitrectomia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA