Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Radiat Prot Dosimetry ; 175(1): 75-86, 2017 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-27664429

RESUMO

The aim of this study was the calculation of conversion coefficients for absorbed doses per fluence (DT/Φ) using the sitting and standing male hybrid phantom (UFH/NCI) exposure to monoenergetic protons with energy ranging from 2 MeV to 10 GeV. Sex-averaged effective dose per fluence (E/Φ) using the results of DT/Φ for the male and female hybrid phantom in standing and sitting postures were also calculated. Results of E/Φ of UFH/NCI standing phantom were also compared with tabulated effective dose conversion coefficients provided in ICRP publication 116. To develop an exposure scenario implementing the male UFH/NCI phantom in sitting and standing postures was used the radiation transport code MCNPX. Whole-body irradiations were performed using the recommended irradiation geometries by ICRP publication 116 antero-posterior (AP), postero-anterior (PA), right and left lateral, rotational (ROT) and isotropic (ISO). In most organs, the conversion coefficients DT/Φ were similar for both postures. However, relative differences were significant for organs located in the lower abdominal region, such as prostate, testes and urinary bladder, especially in the AP geometry. Results of effective dose conversion coefficients were 18% higher in the standing posture of the UFH/NCI phantom, especially below 100 MeV in AP and PA. In lateral geometry, the conversion coefficients values below 20 MeV were 16% higher in the sitting posture. In ROT geometry, the differences were below 10%, for almost all energies. In ISO geometry, the differences in E/Φ were negligible. The results of E/Φ of UFH/NCI phantom were in general below the results of the conversion coefficients provided in ICRP publication 116.


Assuntos
Imagens de Fantasmas , Prótons , Doses de Radiação , Irradiação Corporal Total , Feminino , Humanos , Masculino , Método de Monte Carlo , Neoplasias/radioterapia , Postura , Proteção Radiológica
2.
J Radiol Prot ; 36(4): 885-901, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27798410

RESUMO

Aircraft crew members are occupationally exposed to considerable levels of cosmic radiation at flight altitudes. Since aircrew (pilots and passengers) are in the sitting posture for most of the time during flight, and up to now there has been no data on the effective dose rate calculated for aircrew dosimetry in flight altitude using a sitting phantom, we therefore calculated the effective dose rate using a phantom in the sitting and standing postures in order to compare the influence of the posture on the radiation protection of aircrew members. We found that although the better description of the posture in which the aircrews are exposed, the results of the effective dose rate calculated with the phantom in the sitting posture were very similar to the results of the phantom in the standing posture. In fact we observed only a 1% difference. These findings indicate the adequacy of the use of dose conversion coefficients for the phantom in the standing posture in aircrew dosimetry. We also validated our results comparing the effective dose rate obtained using the standing phantom with values reported in the literature. It was observed that the results presented in this study are in good agreement with other authors (the differences are below 30%) who have measured and calculated effective dose rates using different phantoms.


Assuntos
Aeronaves , Radiação Cósmica , Exposição Ocupacional/análise , Postura , Doses de Radiação , Radiometria/métodos , Feminino , Humanos , Masculino , Neoplasias Induzidas por Radiação/prevenção & controle , Doenças Profissionais/prevenção & controle , Imagens de Fantasmas , Lesões por Radiação/prevenção & controle
4.
Phys Med Biol ; 59(24): 7957-8003, 2014 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-25427139

RESUMO

The conversion coefficients (CCs) relate protection quantities, mean absorbed dose (DT) and effective dose (E), with physical radiation field quantities, such as fluence (Φ). The calculation of CCs through Monte Carlo simulations is useful for estimating the dose in individuals exposed to radiation. The aim of this work was the calculation of conversion coefficients for absorbed and effective doses per fluence (DT/ Φ and E/Φ) using a sitting and standing female hybrid phantom (UFH/NCI) exposure to monoenergetic protons with energy ranging from 2 MeV to 10 GeV. The radiation transport code MCNPX was used to develop exposure scenarios implementing the female UFH/NCI phantom in sitting and standing postures. Whole-body irradiations were performed using the recommended irradiation geometries by ICRP publication 116 (AP, PA, RLAT, LLAT, ROT and ISO). In most organs, the conversion coefficients DT/Φ were similar for both postures. However, relative differences were significant for organs located in the abdominal region, such as ovaries, uterus and urinary bladder, especially in the AP, RLAT and LLAT geometries. Anatomical differences caused by changing the posture of the female UFH/NCI phantom led an attenuation of incident protons with energies below 150 MeV by the thigh of the phantom in the sitting posture, for the front-to-back irradiation, and by the arms and hands of the phantom in the standing posture, for the lateral irradiation.


Assuntos
Simulação por Computador , Imagens de Fantasmas , Postura , Prótons , Radiometria/instrumentação , Irradiação Corporal Total/métodos , Adulto , Biomimética , Carga Corporal (Radioterapia) , Feminino , Humanos , Método de Monte Carlo , Especificidade de Órgãos , Doses de Radiação , Radiometria/normas
5.
Braz. j. med. biol. res ; 41(3): 188-192, Mar. 2008. ilus, tab
Artigo em Inglês | LILACS | ID: lil-476571

RESUMO

Antibodies to citrullinated peptides are highly specific for rheumatoid arthritis (RA) and represent a significant risk factor for undifferentiated polyarthritis. This prognostic ability may be related to the very diagnostic performance of these autoantibodies, since RA is a more erosive disease than other forms of arthritis. The present study evaluated an association of antibodies to citrullinated peptides and the rate of joint destruction in patients with a well-established diagnosis of RA. Seventy-one patients with RA were evaluated in 1994 and again in 2002 (functional class, joint count, Health Assessment Questionnaire score, hands X-ray). Autoantibodies (rheumatoid factor (RF), anti-perinuclear factor, anti-cyclic citrullinated peptide (CCP) antibodies) and Sharp's index were analyzed blindly. Delta Sharp was calculated as the difference in Sharp's index obtained in 1994 and 2002. During the follow-up the Health Assessment Questionnaire score increased from 0.91 ± 0.74 to 1.39 ± 0.72 (P < 0.001). Similarly, the number of swollen joints increased from 4.6 ± 5.71 to 6.4 ± 4.1 (P = 0.002). The frequency of autoantibodies and anti-CCP titer remained stable; however, serum RF concentration increased from 202.8 ± 357.6 to 416.6 ± 636.5 IU/mL (P = 0.003). Sharp's index increased from 56.7 ± 62.1 to 92.4 ± 80.9 (P < 0.001). No correlation was observed between Delta Sharp and the presence of RF, anti-perinuclear factor, and anti-CCP antibodies at baseline. Antibodies to citrullinated epitopes are specific and early markers for the diagnosis of RA but do not seem to be associated with the rate of joint destruction in patients with a well-established diagnosis of RA.


Assuntos
Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Anticorpos Antinucleares/imunologia , Artrite Reumatoide/imunologia , Autoanticorpos/sangue , Peptídeos Cíclicos/imunologia , Fator Reumatoide/imunologia , Artrite Reumatoide/diagnóstico , Artrite Reumatoide/patologia , Biomarcadores/sangue , Ensaio de Imunoadsorção Enzimática , Seguimentos , Prognóstico , Índice de Gravidade de Doença
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA