Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Retina ; 37(6): 1140-1151, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28538613

RESUMO

PURPOSE: To describe a series of retinal acute toxicity cases with severe visual loss after intraocular use of a toxic perfluoro-octane (PFO). The clinical presentation is described, and the likely causes are analyzed. New biological methods for testing safety of intraocular medical devices are proposed. METHODS: Information regarding a series of eyes suffering acute severe events after intraocular use of a toxic PFO was analyzed. Four types of spectroscopy, nuclear magnetic resonance, and chromatography were used to identify the potential PFO contaminants. Cultures of human retinal pigment epithelial cells (ARPE-19) and porcine neuroretina were used to quantify the toxicity of the suspect PFO lots. RESULTS: Of 117 cases of intraocular toxicity, 96 were considered clearly related to the use of PFO. Fifty-three cases had no light perception, and 97 had no measurable visual acuity. Retinal necrosis (n = 38) and vascular occlusion (n = 33) were the most characteristic findings. Two hydroxyl compounds, perfluorooctanoic acid and dodecafluoro-1-heptanol, and benzene derivatives were identified as the suspected toxic agents. While existing toxicity testing failed, we proposed new tests that demonstrated clear toxicity. CONCLUSION: Protocols to determine cytotoxicity of intraocular medical devices should be revised to assure safety. Acute toxic events should be reported to health authorities and scientific media.


Assuntos
Tamponamento Interno/efeitos adversos , Fluorocarbonos/toxicidade , Descolamento Retiniano/cirurgia , Epitélio Pigmentado da Retina/efeitos dos fármacos , Cirurgia Vitreorretiniana/efeitos adversos , Doença Aguda , Animais , Células Cultivadas , Modelos Animais de Doenças , Fluorocarbonos/química , Cromatografia Gasosa-Espectrometria de Massas/métodos , Humanos , Espectroscopia de Ressonância Magnética/métodos , Espectrometria de Massas/métodos , Descolamento Retiniano/metabolismo , Descolamento Retiniano/patologia , Epitélio Pigmentado da Retina/metabolismo , Epitélio Pigmentado da Retina/patologia , Estudos Retrospectivos , Espectroscopia de Infravermelho com Transformada de Fourier/métodos , Suínos , Testes de Toxicidade Aguda/métodos , Acuidade Visual , Cirurgia Vitreorretiniana/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA