Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 223
Filtrar
1.
Eur J Radiol ; 181: 111760, 2024 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-39366193

RESUMO

PURPOSE: To evaluate the clinical value of MR defecography in supporting surgical decision-making and management strategies in a consecutive series of patients. MATERIAL AND METHODS: A consecutive series of patients with clinical suspicion of pelvic disorders who underwent MR defecography at a single university hospital from January 2021 to June 2024 were included. MR defecography was performed at rest (axial/sagittal and coronal T2-weighted sequences), during squeezing, straining, and evacuation (dynamic sagittal T2-weighted sequences). An expert surgeon assessed his satisfaction about the diagnostic information given by the prospective radiological report as: 1: insufficient, 2: sufficient, 3: good, 4: excellent. For patients who underwent surgery, the same surgeon assessed the usefulness of the MR defecography, using a score from 1 to 4 (1: discordant findings, useless exam; 2: concordant findings without new information; 3: concordant findings, useful new information; 4: concordant findings, extremely useful new information). RESULTS: A total of 218 patients (age 27 - 79, mean 60 ± 11; 193 females and 25 males) entered the analysis. For 211 of them (97 %), the radiologist was able to evaluate the images and determine an MR defecography-based diagnosis; in 7 patients (3 %), a diagnosis was not provided due to exam interruption for low patient's compliance. In 195/211 patients (92 %), the radiological diagnosis matched the clinical suspect that prompted the examination. The satisfaction about the diagnostic information given by the radiological report of the 211 exams was assessed by the surgeon as follows: excellent (n = 99, 47 %), good (n = 48, 23 %), sufficient (n = 35, 16 %), and insufficient (n = 29, 14 %). Out of 211 patients, 73 (34.6 %) underwent surgery. MR defecography provided concordant findings with relevant additional information in 63 (86.3 %), concordant findings with additional information in 3 (4.1 %), concordant findings without additional information in 4 (5.5 %), and discordant findings in 3 (4.1 %). CONCLUSIONS: The diagnostic information prospectively provided by MR defecography resulted to be good or excellent in 70 % of the patients, adding clinical value in the preoperative surgical setting in 86 % of those patients who underwent surgery.

2.
Radiol Med ; 2024 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-39460891

RESUMO

A guideline panel formulated a set of recommendations for breast cancer screening and diagnosis to implement clinical activities in Italy in alignment with the European Breast Cancer Guidelines on Screening and Diagnosis (European Commission Initiative on Breast Cancer-ECIBC). The panel issued national recommendations through adopting, adapting, and/or developing recommendations from the European guidelines (ADOLOPMENT approach). This process utilizes the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) evidence to decision (EtD) framework. An additional PubMed search was conducted using search terms specific to Italy to tailor the EU guidelines to the national context. Nine articles were included as contextual evidence in the EtD. A total of 13 recommendations were finalized, either adapted or adopted to suit the national context. Organized breast cancer screening is strongly recommended for women aged 50-69 every 2 years, and it is conditionally recommended every 3 years for women aged 70-74, as well as every 1 or 2 years for women aged 45-49. Annual mammography received a strong recommendation against for women aged 50 and older. Developing shared national guidelines for the management of mammography screening will improve the standardization of processes across all settings, thereby promoting health equity.

3.
Insights Imaging ; 15(1): 240, 2024 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-39373853

RESUMO

In order to assess the perceptions and expectations of the radiology staff about artificial intelligence (AI), we conducted an online survey among ESR members (January-March 2024). It was designed considering that conducted in 2018, updated according to recent advancements and emerging topics, consisting of seven questions regarding demographics and professional background and 28 AI questions. Of 28,000 members contacted, 572 (2%) completed the survey. AI impact was predominantly expected on breast and oncologic imaging, primarily involving CT, mammography, and MRI, and in the detection of abnormalities in asymptomatic subjects. About half of responders did not foresee an impact of AI on job opportunities. For 273/572 respondents (48%), AI-only reports would not be accepted by patients; and 242/572 respondents (42%) think that the use of AI systems will not change the relationship between the radiological team and the patient. According to 255/572 respondents (45%), radiologists will take responsibility for any AI output that may influence clinical decision-making. Of 572 respondents, 274 (48%) are currently using AI, 153 (27%) are not, and 145 (25%) are planning to do so. In conclusion, ESR members declare familiarity with AI technologies, as well as recognition of their potential benefits and challenges. Compared to the 2018 survey, the perception of AI's impact on job opportunities is in general slightly less optimistic (more positive from AI users/researchers), while the radiologist's responsibility for AI outputs is confirmed. The use of large language models is declared not only limited to research, highlighting the need for education in AI and its regulations. CRITICAL RELEVANCE STATEMENT: This study critically evaluates the current impact of AI on radiology, revealing significant usage patterns and clinical implications, thereby guiding future integration strategies to enhance efficiency and patient care in clinical radiology. KEY POINTS: The survey examines ESR member's views about the impact of AI on radiology practice. AI use is relevant in CT and MRI, with varying impacts on job roles. AI tools enhance clinical efficiency but require radiologist oversight for patient acceptance.

4.
Radiol Med ; 129(10): 1522-1529, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39162940

RESUMO

PURPOSE: This study aimed to determine the accuracy of detecting ischemic core volume using computed tomography perfusion (CTP) in patients with suspected acute ischemic stroke compared to diffusion-weighted magnetic resonance imaging (DW-MRI) as the reference standard. METHODS: This retrospective monocentric study included patients who underwent CTP and DW-MRI for suspected acute ischemic stroke. The ischemic core size was measured at DW-MRI. The detectability threshold volume was defined as the lowest volume detected by each method. Clinical data on revascularization therapy, along with the clinical decision that influenced the choice, were collected. Volumes of the ischemic cores were compared using the Mann-Whitney U test. RESULTS: Of 83 patients who underwent CTP, 52 patients (median age 73 years, IQR 63-80, 36 men) also had DW-MRI and were included, with a total of 70 ischemic cores. Regarding ischemic cores, only 18/70 (26%) were detected by both CTP and DW-MRI, while 52/70 (74%) were detected only by DW-MRI. The median volume of the 52 ischemic cores undetected on CTP (0.6 mL, IQR 0.2-1.3 mL) was significantly lower (p < 0.001) than that of the 18 ischemic cores detected on CTP (14.2 mL, IQR 7.0-18.4 mL). The smallest ischemic core detected on CTP had a volume of 5.0 mL. Among the 20 patients with undetected ischemic core on CTP, only 10% (2/20) received thrombolysis treatment. CONCLUSIONS: CTP maps failed in detecting ischemic cores smaller than 5 mL. DW-MRI remains essential for suspected small ischemic brain lesions to guide a correct treatment decision-making.


Assuntos
Imagem de Difusão por Ressonância Magnética , AVC Isquêmico , Tomografia Computadorizada por Raios X , Humanos , Masculino , Idoso , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Imagem de Difusão por Ressonância Magnética/métodos , AVC Isquêmico/diagnóstico por imagem , AVC Isquêmico/tratamento farmacológico , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Isquemia Encefálica/diagnóstico por imagem
5.
Radiol Med ; 129(9): 1288-1302, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39162938

RESUMO

PURPOSE: This study quantifies the impact on budget and cost per health benefit of implementing digital breast tomosynthesis (DBT) in place of digital mammography (DM) for breast cancer screening among asymptomatic women in Italy. METHODS: A budget impact analysis and a cost consequence analysis were conducted using parameters from the MAITA project and literature. The study considered four scenarios for DBT implementation, i.e., DBT for all women, DBT for women aged 45-49 years, DBT based on breast density (BI-RADS C + D or D only), and compared these to the current DM screening. Healthcare provider's perspective was adopted, including screening, diagnosis, and cancer treatment costs. RESULTS: Introducing DBT for all women would increase overall screening costs by 20%. Targeting DBT to women aged 45-49 years or with dense breasts would result in smaller cost increases (3.2% for age-based and 1.4-10.7% for density-based scenarios). The cost per avoided interval cancer was significantly higher when DBT was applied to all women compared to targeted approaches. The cost per gained early-detected cancer slightly increases in targeted approaches, while the assumptions on the clinical significance and overdiagnosis of cancers detected by DBT and not by DM have a strong impact. CONCLUSIONS: Implementing DBT as a primary breast cancer test in screening programs in Italy would lead to a substantial increase in costs. Tailoring DBT use to women aged 45-49 or with dense breasts could enhance the feasibility and sustainability of the intervention. Further research is needed to clarify the impact of DBT on overdiagnosis and the long-term outcomes.


Assuntos
Neoplasias da Mama , Orçamentos , Análise Custo-Benefício , Detecção Precoce de Câncer , Mamografia , Humanos , Neoplasias da Mama/diagnóstico por imagem , Feminino , Itália , Mamografia/economia , Mamografia/métodos , Pessoa de Meia-Idade , Detecção Precoce de Câncer/economia , Detecção Precoce de Câncer/métodos , Idoso
6.
Radiol Med ; 129(9): 1303-1312, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39060886

RESUMO

PURPOSE: To evaluate if background parenchymal enhancement (BPE) on contrast-enhanced mammography (CEM), graded according to the 2022 CEM-dedicated Breast Imaging Reporting and Data System (BI-RADS) lexicon, is associated with breast density, menopausal status, and age. METHODS: This bicentric retrospective analysis included CEM examinations performed for the work-up of suspicious mammographic findings. Three readers independently and blindly evaluated BPE on recombined CEM images and breast density on low-energy CEM images. Inter-reader reliability was estimated using Fleiss κ. Multivariable binary logistic regression was performed, dichotomising breast density and BPE as low (a/b BI-RADS categories, minimal/mild BPE) and high (c/d BI-RADS categories, moderate/marked BPE). RESULTS: A total of 200 women (median age 56.8 years, interquartile range 50.5-65.6, 140/200 in menopause) were included. Breast density was classified as a in 27/200 patients (13.5%), as b in 110/200 (55.0%), as c in 52/200 (26.0%), and as d in 11/200 (5.5%), with moderate inter-reader reliability (κ = 0.536; 95% confidence interval [CI] 0.482-0.590). BPE was minimal in 95/200 patients (47.5%), mild in 64/200 (32.0%), moderate in 25/200 (12.5%), marked in 16/200 (8.0%), with substantial inter-reader reliability (κ = 0.634; 95% CI 0.581-0.686). At multivariable logistic regression, premenopausal status and breast density were significant positive predictors of high BPE, with adjusted odds ratios of 6.120 (95% CI 1.847-20.281, p = 0.003) and 2.416 (95% CI 1.095-5.332, p = 0.029) respectively. CONCLUSION: BPE on CEM is associated with well-established breast cancer risk factors, being higher in women with higher breast density and premenopausal status.


Assuntos
Densidade da Mama , Neoplasias da Mama , Meios de Contraste , Mamografia , Humanos , Feminino , Pessoa de Meia-Idade , Mamografia/métodos , Estudos Retrospectivos , Idoso , Neoplasias da Mama/diagnóstico por imagem , Reprodutibilidade dos Testes , Mama/diagnóstico por imagem , Menopausa , Fatores Etários , Intensificação de Imagem Radiográfica/métodos
7.
Eur Radiol Exp ; 8(1): 80, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39004645

RESUMO

INTRODUCTION: Breast arterial calcifications (BAC) are common incidental findings on routine mammograms, which have been suggested as a sex-specific biomarker of cardiovascular disease (CVD) risk. Previous work showed the efficacy of a pretrained convolutional network (CNN), VCG16, for automatic BAC detection. In this study, we further tested the method by a comparative analysis with other ten CNNs. MATERIAL AND METHODS: Four-view standard mammography exams from 1,493 women were included in this retrospective study and labeled as BAC or non-BAC by experts. The comparative study was conducted using eleven pretrained convolutional networks (CNNs) with varying depths from five architectures including Xception, VGG, ResNetV2, MobileNet, and DenseNet, fine-tuned for the binary BAC classification task. Performance evaluation involved area under the receiver operating characteristics curve (AUC-ROC) analysis, F1-score (harmonic mean of precision and recall), and generalized gradient-weighted class activation mapping (Grad-CAM++) for visual explanations. RESULTS: The dataset exhibited a BAC prevalence of 194/1,493 women (13.0%) and 581/5,972 images (9.7%). Among the retrained models, VGG, MobileNet, and DenseNet demonstrated the most promising results, achieving AUC-ROCs > 0.70 in both training and independent testing subsets. In terms of testing F1-score, VGG16 ranked first, higher than MobileNet (0.51) and VGG19 (0.46). Qualitative analysis showed that the Grad-CAM++ heatmaps generated by VGG16 consistently outperformed those produced by others, offering a finer-grained and discriminative localization of calcified regions within images. CONCLUSION: Deep transfer learning showed promise in automated BAC detection on mammograms, where relatively shallow networks demonstrated superior performances requiring shorter training times and reduced resources. RELEVANCE STATEMENT: Deep transfer learning is a promising approach to enhance reporting BAC on mammograms and facilitate developing efficient tools for cardiovascular risk stratification in women, leveraging large-scale mammographic screening programs. KEY POINTS: • We tested different pretrained convolutional networks (CNNs) for BAC detection on mammograms. • VGG and MobileNet demonstrated promising performances, outperforming their deeper, more complex counterparts. • Visual explanations using Grad-CAM++ highlighted VGG16's superior performance in localizing BAC.


Assuntos
Doenças Mamárias , Aprendizado Profundo , Mamografia , Humanos , Mamografia/métodos , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Doenças Mamárias/diagnóstico por imagem , Idoso , Adulto , Mama/diagnóstico por imagem , Calcificação Vascular/diagnóstico por imagem , Calcinose/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
8.
Radiol Med ; 129(8): 1156-1172, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39042203

RESUMO

PURPOSE: We present a comprehensive investigation into the organizational, social, and ethical impact of implementing digital breast tomosynthesis (DBT) as a primary test for breast cancer screening in Italy. The analyses aimed to assess the feasibility of DBT specifically for all women aged 45-74, women aged 45-49 only, or those with dense breasts only. METHODS: Questions were framed according to the European Network of Health Technology Assessment (EuNetHTA) Screening Core Model to produce evidence for the resources, equity, acceptability, and feasibility domains of the Grading of Recommendations Assessment, Development and Evaluation (GRADE) decision framework. The study integrated evidence from the literature, the MAITA DBT trials, and Italian pilot programs. Structured interviews, surveys, and systematic reviews were conducted to gather data on organizational impact, acceptability among women, reading and acquisition times, and the technical requirements of DBT in screening. RESULTS: Implementing DBT could significantly affect the screening program, primarily due to increased reading times and the need for additional human resources (radiologists and radiographers). Participation rates in DBT screening were similar, if not better, to those observed with standard digital mammography, indicating good acceptability among women. The study also highlighted the necessity for specific training for radiographers. The interviewed key persons unanimously considered feasible tailored screening strategies based on breast density or age, but they require effective communication with the target population. CONCLUSIONS: An increase in radiologists' and radiographers' workload limits the feasibility of DBT screening. Tailored screening strategies may maximize the benefits of DBT while mitigating potential challenges.


Assuntos
Neoplasias da Mama , Detecção Precoce de Câncer , Mamografia , Humanos , Feminino , Neoplasias da Mama/diagnóstico por imagem , Itália , Mamografia/métodos , Pessoa de Meia-Idade , Idoso , Detecção Precoce de Câncer/métodos , Estudos de Viabilidade
9.
Insights Imaging ; 15(1): 96, 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38536530

RESUMO

In the mid-1990s, the identification of BRCA1/2 genes for breast cancer susceptibility led to testing breast MRI accuracy in screening women at increased risk. From 2000 onwards, ten intraindividual comparative studies showed the marked superiority of MRI: the sensitivity ranged 25-58% for mammography, 33-52% for ultrasound, 48-67% for mammography plus ultrasound, and 71-100% for MRI; specificity 93-100%, 91-98%, 89-98%, and 81-98%, respectively. Based on the available evidence, in 2006-2007, the UK National Institute for Clinical Excellence and the American Cancer Society recommended MRI screening of high-risk women, followed by other international guidelines. Despite evidence-based medicine ideally requiring randomised controlled trials (RCTs) for policy changes regarding screening procedures, breast MRI for high-risk screening was adopted in many countries worldwide. In 2019, the results of the "DENSE" RCT were published in favour of breast MRI screening of women with extremely dense breasts compared to mammography alone, showing a reduction of more than 80% of the interval cancer rate in women who attended MRI screening. Even though international recommendations in favour of this practice were issued, substantial obstacles still prevent health systems from adopting breast MRI for screening women with extremely dense breasts. A paradox is evident: we adopted a screening procedure without evidence from RCTs, and now that we have this level-1 evidence for the same procedure, we fail to do so. This critical review tries to explain the differences between the two cases, as examples of the complex pathways of translating radiological research into everyday practice.Critical relevance statement The high-level evidence in favour of breast MRI screening of women with extremely dense breasts is failing to persuade policy makers to translate this into clinical practice.Key points• Breast MRI screening of high-risk women was adopted on basis of the evidence provided by test accuracy comparative studies showing an MRI performance greatly superior to that of mammography.• Breast MRI screening of women with extremely dense breasts has not been adopted although the evidence of a large reduction in interval cancer rate from a RCT.• We illustrate the differences between the two cases, as an example of the complex ways of translation of radiological research in clinical practice according to the EBM theory.

10.
Eur J Cancer ; 198: 113500, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38199146

RESUMO

INTRODUCTION: Quality care in breast cancer is higher if patients are treated in a Breast Center with a dedicated and specialized multidisciplinary team. Quality control is an essential activity to ensure quality care, which has to be based on the monitoring of specific quality indicators. Eusoma has proceeded with the up-dating of the 2017 Quality indicators for non-metastatic breast cancer based on the new diagnostic, locoregional and systemic treatment modalities. METHODS: To proceed with the updating, EUSOMA setup a multidisciplinary working group of BC experts and patients' representatives. It is a comprehensive set of QIs for early breast cancer care, which are classified as mandatory, recommended, or observational. For the first time patient reported outcomes (PROMs) have been included. As used in the 2017 EUSOMA QIs, evidence levels were based on the short version of the US Agency for Healthcare Research and Quality. RESULTS: This is a set of quality indicators representative for the different steps of the patient pathway in non-metastatic setting, which allow Breast Centres to monitor their performance with referring standards, i.e minimum standard and target. CONCLUSIONS: Monitoring these Quality Indicators, within the Eusoma datacentre will allow to have a state of the art picture at European Breast Centres level and the development of challenging research projects.


Assuntos
Neoplasias da Mama , Indicadores de Qualidade em Assistência à Saúde , Humanos , Feminino , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/terapia , Qualidade da Assistência à Saúde
11.
Insights Imaging ; 15(1): 13, 2024 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-38228934

RESUMO

At the European Society of Radiology (ESR), we strive to provide evidence for radiological practices that improve patient outcomes and have a societal impact. Successful translation of radiological research into clinical practice requires multiple factors including tailored methodology, a multidisciplinary approach aiming beyond technical validation, and a focus on unmet clinical needs. Low levels of evidence are a threat to radiology, resulting in low visibility and credibility. Here, we provide the background and rationale for the thematic series Translating radiological research into practice-from discovery to clinical impact, inviting authors to describe their processes of achieving clinically impactful radiological research. We describe the challenges unique to radiological research. Additionally, a survey was sent to non-radiological clinical societies. The majority of respondents (6/11) were in the field of gastrointestinal/abdominal medicine. The implementation of CT/MRI techniques for disease characterisation, detection and staging of cancer, and treatment planning and radiological interventions were mentioned as the most important radiological developments in the past years. The perception was that patients are substantially unaware of the impact of these developments. Unmet clinical needs were mostly early diagnosis and staging of cancer, microstructural/functional assessment of tissues and organs, and implant assessment. All but one respondent considered radiology important for research in their discipline, but five indicated that radiology is currently not involved in their research. Radiology research holds the potential for being transformative to medical practice. It is our responsibility to take the lead in studies including radiology and strive towards the highest levels of evidence.Critical relevance statement For radiological research to make a clinical and societal impact, radiologists should take the lead in radiological studies, go beyond the assessment of technical feasibility and diagnostic accuracy, and-in a multidisciplinary approach-address clinical unmet needs.Key points• Multiple factors are essential for radiological research to make a clinical and societal impact.• Radiological research needs to go beyond diagnostic accuracy and address unmet clinical needs.• Radiologists should take the lead in radiological studies with a multidisciplinary approach.

12.
Eur J Cancer ; 199: 113553, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38262307

RESUMO

AIM: The analyses here reported aim to compare the screening performance of digital tomosynthesis (DBT) versus mammography (DM). METHODS: MAITA is a consortium of four Italian trials, REtomo, Proteus, Impeto, and MAITA trial. The trials adopted a two-arm randomised design comparing DBT plus DM (REtomo and Proteus) or synthetic-2D (Impeto and MAITA trial) versus DM; multiple vendors were included. Women aged 45 to 69 years were individually randomised to one round of DBT or DM. FINDINGS: From March 2014 to February 2022, 50,856 and 63,295 women were randomised to the DBT and DM arm, respectively. In the DBT arm, 6656 women were screened with DBT plus synthetic-2D. Recall was higher in the DBT arm (5·84% versus 4·96%), with differences between centres. With DBT, 0·8/1000 (95% CI 0·3 to 1·3) more women received surgical treatment for a benign lesion. The detection rate was 51% higher with DBT, ie. 2·6/1000 (95% CI 1·7 to 3·6) more cancers detected, with a similar relative increase for invasive cancers and ductal carcinoma in situ. The results were similar below and over the age of 50, at first and subsequent rounds, and with DBT plus DM and DBT plus synthetic-2D. No learning curve was appreciable. Detection of cancers >= 20 mm, with 2 or more positive lymph nodes, grade III, HER2-positive, or triple-negative was similar in the two arms. INTERPRETATION: Results from MAITA confirm that DBT is superior to DM for the detection of cancers, with a possible increase in recall rate. DBT performance in screening should be assessed locally while waiting for long-term follow-up results on the impact of advanced cancer incidence.


Assuntos
Neoplasias da Mama , Carcinoma Intraductal não Infiltrante , Feminino , Humanos , Mama/diagnóstico por imagem , Mama/patologia , Neoplasias da Mama/diagnóstico , Detecção Precoce de Câncer/métodos , Incidência , Mamografia/métodos , Programas de Rastreamento/métodos , Pessoa de Meia-Idade , Idoso , Ensaios Clínicos Controlados Aleatórios como Assunto
14.
Eur Radiol ; 34(4): 2699-2710, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37823922

RESUMO

OBJECTIVES: MRI-derived extracellular volume (ECV) allows characterization of myocardial changes before the onset of overt pathology, which may be caused by cancer therapy cardiotoxicity. Our purpose was to review studies exploring the role of MRI-derived ECV as an early cardiotoxicity biomarker to guide timely intervention. MATERIALS AND METHODS: In April 2022, we performed a systematic search on EMBASE and PubMed for articles on MRI-derived ECV as a biomarker of cancer therapy cardiotoxicity. Two blinded researchers screened the retrieved articles, including those reporting ECV values at least 3 months from cardiotoxic treatment. Data extraction was performed for each article, including clinical and technical data, and ECV values. Pooled ECV was calculated using the random effects model and compared among different treatment regimens and among those who did or did not experience overt cardiac dysfunction. Meta-regression analyses were conducted to appraise which clinical or technical variables yielded a significant impact on ECV. RESULTS: Overall, 19 studies were included. Study populations ranged from 9 to 236 patients, for a total of 1123 individuals, with an average age ranging from 12.5 to 74 years. Most studies included patients with breast or esophageal cancer, treated with anthracyclines and chest radiotherapy. Pooled ECV was 28.44% (95% confidence interval, CI, 26.85-30.03%) among subjects who had undergone cardiotoxic cancer therapy, versus 25.23% (95%CI 23.31-27.14%) among those who had not (p = .003). CONCLUSION: A higher ECV in patients who underwent cardiotoxic treatment could imply subclinical changes in the myocardium, present even before overt cardiac pathology is detectable. CLINICAL RELEVANCE STATEMENT: The ability to detect subclinical changes in the myocardium displayed by ECV suggests its use as an early biomarker of cancer therapy-related cardiotoxicity. KEY POINTS: • Cardiotoxicity is a common adverse effect of cancer therapy; therefore, its prompt detection could improve patient outcomes. • Pooled MRI-derived myocardial extracellular volume was higher in patients who underwent cardiotoxic cancer therapy than in those who did not (28.44% versus 25.23%, p = .003). • MRI-derived myocardial extracellular volume represents a potential early biomarker of cancer therapy cardiotoxicity.


Assuntos
Cardiotoxicidade , Neoplasias , Humanos , Criança , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Cardiotoxicidade/diagnóstico por imagem , Cardiotoxicidade/etiologia , Cardiotoxicidade/patologia , Imageamento por Ressonância Magnética , Miocárdio/patologia , Biomarcadores , Neoplasias/diagnóstico por imagem , Neoplasias/tratamento farmacológico , Neoplasias/patologia , Imagem Cinética por Ressonância Magnética , Valor Preditivo dos Testes
15.
Eur J Surg Oncol ; 50(1): 107292, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38061151

RESUMO

INTRODUCTION: Breast lesions of uncertain malignant potential (B3) include atypical ductal and lobular hyperplasias, lobular carcinoma in situ, flat epithelial atypia, papillary lesions, radial scars and fibroepithelial lesions as well as other rare miscellaneous lesions. They are challenging to categorise histologically, requiring specialist training and multidisciplinary input. They may coexist with in situ or invasive breast cancer (BC) and increase the risk of subsequent BC development. Management should focus on adequate classification and management whilst avoiding overtreatment. The aim of these guidelines is to provide updated information regarding the diagnosis and management of B3 lesions, according to updated literature review evidence. METHODS: These guidelines provide practical recommendations which can be applied in clinical practice which include recommendation grade and level of evidence. All sections were written according to an updated literature review and discussed at a consensus meeting. Critical appraisal by the expert writing committee adhered to the 23 items in the international Appraisal of Guidelines, Research and Evaluation (AGREE) tool. RESULTS: Recommendations for further management after core-needle biopsy (CNB) or vacuum-assisted biopsy (VAB) diagnosis of a B3 lesion reported in this guideline, vary depending on the presence of atypia, size of lesion, sampling size, and patient preferences. After CNB or VAB, the option of vacuum-assisted excision or surgical excision should be evaluated by a multidisciplinary team and shared decision-making with the patient is crucial for personalizing further treatment. De-escalation of surgical intervention for B3 breast lesions is ongoing, and the inclusion of vacuum-assisted excision (VAE) will decrease the need for surgical intervention in further approaches. Communication with patients may be different according to histological diagnosis, presence or absence of atypia, or risk of upgrade due to discordant imaging. Written information resources to help patients understand these issues alongside with verbal communication is recommended. Lifestyle interventions have a significant impact on BC incidence so lifestyle interventions need to be suggested to women at increased BC risk as a result of a diagnosis of a B3 lesion. CONCLUSIONS: These guidelines provide a state-of-the-art overview of the diagnosis, management and prognosis of B3 lesions in modern multidisciplinary breast practice.


Assuntos
Neoplasias da Mama , Mama , Feminino , Humanos , Biópsia com Agulha de Grande Calibre , Mama/patologia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/terapia , Mamografia/métodos
16.
Eur J Cancer ; 196: 113438, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37995597

RESUMO

INTRODUCTION: The present study was designed to describe tumour features and treatments for patients with breast cancer. It also aimed at assessing the risk of distant metastases in relation to biological profiles, disease stages and treatment. METHODS: Data were analysed from 81,882 patients in the EUSOMA database (disease stages at diagnosis 0-IV; median age 61 years; range 20-100 years). All patients were treated between January 2016 and December 2021 in 53 Breast Centres within the EUSOMA certification process in 13 European countries. Cases were classified as HR+ /HER2-, HR+ /HER2 + , HR-/HER2 + or HR-/HER2- and data were analysed accordingly. RESULTS: Univariable and multivariable analyses for distant metastases were conducted on a subset of 38,119 cases with information on whether or not they had developed them. Potential determinants included sub-group type, Ki67 value, disease stage, adjuvant systemic therapies and post-operative radiation therapy. In multivariable analysis, the HR-/HER2 + and HR-/HER2- sub-groups were associated with a higher risk of distant metastases than HR+ /HER2-. Ki67 > 20 % and advanced stage disease also carried a high risk. Radiation therapy emerged as a protective factor against distant metastases. CONCLUSIONS: Present results show a large patient database offers an information stream that can be applied to reduce uncertainties in clinical practice. Database parameters need to be updated dynamically for outcome monitoring. Molecular prognostic factors, gene-expression signatures, tumour-infiltrating lymphocytes and circulating tumoral DNA should be added.


Assuntos
Neoplasias da Mama , Humanos , Pessoa de Meia-Idade , Feminino , Neoplasias da Mama/tratamento farmacológico , Antígeno Ki-67 , Receptor ErbB-2 , Terapia Combinada , Resultado do Tratamento , Prognóstico
17.
Eur Radiol ; 2023 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-37999727

RESUMO

OBJECTIVES: To investigate the influence of preoperative breast MRI on mastectomy and reoperation rates in patients with pure ductal carcinoma in situ (DCIS). METHODS: The MIPA observational study database (7245 patients) was searched for patients aged 18-80 years with pure unilateral DCIS diagnosed at core needle or vacuum-assisted biopsy (CNB/VAB) and planned for primary surgery. Patients who underwent preoperative MRI (MRI group) were matched (1:1) to those who did not receive MRI (noMRI group) according to 8 confounding covariates that drive referral to MRI (age; hormonal status; familial risk; posterior-to-nipple diameter; BI-RADS category; lesion diameter; lesion presentation; surgical planning at conventional imaging). Surgical outcomes were compared between the matched groups with nonparametric statistics after calculating odds ratios (ORs). RESULTS: Of 1005 women with pure unilateral DCIS at CNB/VAB (507 MRI group, 498 noMRI group), 309 remained in each group after matching. First-line mastectomy rate in the MRI group was 20.1% (62/309 patients, OR 2.03) compared to 11.0% in the noMRI group (34/309 patients, p = 0.003). The reoperation rate was 10.0% in the MRI group (31/309, OR for reoperation 0.40) and 22.0% in the noMRI group (68/309, p < 0.001), with a 2.53 OR of avoiding reoperation in the MRI group. The overall mastectomy rate was 23.3% in the MRI group (72/309, OR 1.40) and 17.8% in the noMRI group (55/309, p = 0.111). CONCLUSIONS: Compared to those going directly to surgery, patients with pure DCIS at CNB/VAB who underwent preoperative MRI had a higher OR for first-line mastectomy but a substantially lower OR for reoperation. CLINICAL RELEVANCE STATEMENT: When confounding factors behind MRI referral are accounted for in the comparison of patients with CNB/VAB-diagnosed pure unilateral DCIS, preoperative MRI yields a reduction of reoperations that is more than twice as high as the increase in overall mastectomies. KEY POINTS: • Confounding factors cause imbalance when investigating the influence of preoperative MRI on surgical outcomes of pure DCIS. • When patient matching is applied to women with pure unilateral DCIS, reoperation rates are significantly reduced in women who underwent preoperative MRI. • The reduction of reoperations brought about by preoperative MRI is more than double the increase in overall mastectomies.

18.
Insights Imaging ; 14(1): 126, 2023 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-37466753

RESUMO

Axillary lymphadenopathy is a common side effect of COVID-19 vaccination, leading to increased imaging-detected asymptomatic and symptomatic unilateral axillary lymphadenopathy. This has threatened to negatively impact the workflow of breast imaging services, leading to the release of ten recommendations by the European Society of Breast Imaging (EUSOBI) in August 2021. Considering the rapidly changing scenario and data scarcity, these initial recommendations kept a highly conservative approach. As of 2023, according to newly acquired evidence, EUSOBI proposes the following updates, in order to reduce unnecessary examinations and avoid delaying necessary examinations. First, recommendation n. 3 has been revised to state that breast examinations should not be delayed or rescheduled because of COVID-19 vaccination, as evidence from the first pandemic waves highlights how delayed or missed screening tests have a negative effect on breast cancer morbidity and mortality, and that there is a near-zero risk of subsequent malignant findings in asymptomatic patients who have unilateral lymphadenopathy and no suspicious breast findings. Second, recommendation n. 7 has been revised to simplify follow-up strategies: in patients without breast cancer history and no imaging findings suspicious for cancer, symptomatic and asymptomatic imaging-detected unilateral lymphadenopathy on the same side of recent COVID-19 vaccination (within 12 weeks) should be classified as a benign finding (BI-RADS 2) and no further work-up should be pursued. All other recommendations issued by EUSOBI in 2021 remain valid.

19.
Eur Radiol ; 33(9): 6213-6225, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37138190

RESUMO

OBJECTIVES: To report mastectomy and reoperation rates in women who had breast MRI for screening (S-MRI subgroup) or diagnostic (D-MRI subgroup) purposes, using multivariable analysis for investigating the role of MRI referral/nonreferral and other covariates in driving surgical outcomes. METHODS: The MIPA observational study enrolled women aged 18-80 years with newly diagnosed breast cancer destined to have surgery as the primary treatment, in 27 centres worldwide. Mastectomy and reoperation rates were compared using non-parametric tests and multivariable analysis. RESULTS: A total of 5828 patients entered analysis, 2763 (47.4%) did not undergo MRI (noMRI subgroup) and 3065 underwent MRI (52.6%); of the latter, 2441/3065 (79.7%) underwent MRI with preoperative intent (P-MRI subgroup), 510/3065 (16.6%) D-MRI, and 114/3065 S-MRI (3.7%). The reoperation rate was 10.5% for S-MRI, 8.2% for D-MRI, and 8.5% for P-MRI, while it was 11.7% for noMRI (p ≤ 0.023 for comparisons with D-MRI and P-MRI). The overall mastectomy rate (first-line mastectomy plus conversions from conserving surgery to mastectomy) was 39.5% for S-MRI, 36.2% for P-MRI, 24.1% for D-MRI, and 18.0% for noMRI. At multivariable analysis, using noMRI as reference, the odds ratios for overall mastectomy were 2.4 (p < 0.001) for S-MRI, 1.0 (p = 0.957) for D-MRI, and 1.9 (p < 0.001) for P-MRI. CONCLUSIONS: Patients from the D-MRI subgroup had the lowest overall mastectomy rate (24.1%) among MRI subgroups and the lowest reoperation rate (8.2%) together with P-MRI (8.5%). This analysis offers an insight into how the initial indication for MRI affects the subsequent surgical treatment of breast cancer. KEY POINTS: • Of 3065 breast MRI examinations, 79.7% were performed with preoperative intent (P-MRI), 16.6% were diagnostic (D-MRI), and 3.7% were screening (S-MRI) examinations. • The D-MRI subgroup had the lowest mastectomy rate (24.1%) among MRI subgroups and the lowest reoperation rate (8.2%) together with P-MRI (8.5%). • The S-MRI subgroup had the highest mastectomy rate (39.5%) which aligns with higher-than-average risk in this subgroup, with a reoperation rate (10.5%) not significantly different to that of all other subgroups.


Assuntos
Neoplasias da Mama , Feminino , Humanos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Mastectomia , Mastectomia Segmentar , Mama , Imageamento por Ressonância Magnética , Cuidados Pré-Operatórios
20.
Eur Radiol ; 33(10): 6746-6755, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37160426

RESUMO

OBJECTIVE: Breast arterial calcifications (BAC) are a sex-specific cardiovascular disease biomarker that might improve cardiovascular risk stratification in women. We implemented a deep convolutional neural network for automatic BAC detection and quantification. METHODS: In this retrospective study, four readers labelled four-view mammograms as BAC positive (BAC+) or BAC negative (BAC-) at image level. Starting from a pretrained VGG16 model, we trained a convolutional neural network to discriminate BAC+ and BAC- mammograms. Accuracy, F1 score, and area under the receiver operating characteristic curve (AUC-ROC) were used to assess the diagnostic performance. Predictions of calcified areas were generated using the generalized gradient-weighted class activation mapping (Grad-CAM++) method, and their correlation with manual measurement of BAC length in a subset of cases was assessed using Spearman ρ. RESULTS: A total 1493 women (198 BAC+) with a median age of 59 years (interquartile range 52-68) were included and partitioned in a training set of 410 cases (1640 views, 398 BAC+), validation set of 222 cases (888 views, 89 BAC+), and test set of 229 cases (916 views, 94 BAC+). The accuracy, F1 score, and AUC-ROC were 0.94, 0.86, and 0.98 in the training set; 0.96, 0.74, and 0.96 in the validation set; and 0.97, 0.80, and 0.95 in the test set, respectively. In 112 analyzed views, the Grad-CAM++ predictions displayed a strong correlation with BAC measured length (ρ = 0.88, p < 0.001). CONCLUSION: Our model showed promising performances in BAC detection and in quantification of BAC burden, showing a strong correlation with manual measurements. CLINICAL RELEVANCE STATEMENT: Integrating our model to clinical practice could improve BAC reporting without increasing clinical workload, facilitating large-scale studies on the impact of BAC as a biomarker of cardiovascular risk, raising awareness on women's cardiovascular health, and leveraging mammographic screening. KEY POINTS: • We implemented a deep convolutional neural network (CNN) for BAC detection and quantification. • Our CNN had an area under the receiving operator curve of 0.95 for BAC detection in the test set composed of 916 views, 94 of which were BAC+ . • Furthermore, our CNN showed a strong correlation with manual BAC measurements (ρ = 0.88) in a set of 112 views.


Assuntos
Doenças Mamárias , Doenças Cardiovasculares , Aprendizado Profundo , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Mamografia/métodos , Doenças Mamárias/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA