Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Female Pelvic Med Reconstr Surg ; 27(1): e28-e38, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-31625957

RESUMO

OBJECTIVE: This study examined biomechanical changes in pelvic floor after urogynecological surgery. METHODS: This multisite clinical study was designed to explore changes in tissue elasticity, pelvic support, and certain functions (contractive strength, muscle relaxation speed, muscle motility) after pelvic organ prolapse (POP) surgery. A biomechanical mapping of the pelvic floor was performed before and 4 to 6 months after the surgery. The biomechanical data for 52 parameters were acquired by vaginal tactile imaging for manually applied deflection pressures to vaginal walls and pelvic muscle contractions. The two-sample t-test (P < 0.05) was used to test the null hypothesis that presurgery data in group 1 (positive parameter change after surgery) and presurgery data in group 2 (negative parameter change after surgery) belonged to the same distribution. RESULTS: A total of 78 subjects with 255 surgical procedures were analyzed across 5 participating clinical sites. All 52 t-tests for group 1 versus group 2 had P value in the range from 4.0 × 10-10 to 4.3 × 10-2 associating all of the 52 parameter changes after surgery with the presurgical conditions. The P value of before and after surgery correlation ranged from 3.7 × 10-18 to 1.6 × 10-2 for 50 of 52 tests, with Pearson correlation coefficient ranging from -0.79 to -0.27. Thus, vaginal tactile imaging parameters strongly correlated weak pelvic floor presurgery with the positive POP surgery outcome of improved biomechanical properties. CONCLUSIONS: Pelvic organ prolapse surgery, in general, improves the biomechanical conditions and integrity of the weak pelvic floor. The proposed biomechanical parameters can predict changes resulting from POP surgery.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Elasticidade , Contração Muscular , Diafragma da Pelve/diagnóstico por imagem , Fenômenos Biomecânicos , Feminino , Humanos , Diafragma da Pelve/fisiopatologia , Prolapso de Órgão Pélvico/cirurgia
2.
Sex Med ; 6(1): 39-48, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29273316

RESUMO

INTRODUCTION: Few means exist to provide quantitative and reproducible assessment of vaginal conditions from biomechanical and functional standpoints. AIM: To develop a new approach for quantitative biomechanical characterization of the vagina. METHODS: Vaginal tactile imaging (VTI) allows biomechanical assessment of soft tissue and function along the entire length of the anterior, posterior, and lateral vaginal walls. This can be done at rest, with applied vaginal deformation, and with pelvic muscle contraction. RESULTS: Data were analyzed for 42 subjects with normal pelvic floor support from an observational case-controlled clinical study. The average age was 52 years (range = 26-90 years). We introduced 8 VTI parameters to characterize vaginal conditions: (i) maximum resistance force to insertion (newtons), (ii) insertion work (millijoules), (iii) maximum stress-to-strain ratio (elasticity; kilopascals per millimeter), (iv) maximum pressure at rest (kilopascals), (v) anterior-posterior force at rest (newtons), (vi) left-right force at rest (newtons), (vii) maximum pressure at muscle contraction (kilopascals), and (viii) muscle contraction force (newtons). We observed low to moderate correlation of these parameters with subject age and no correlation with subject weight. 6 of 8 parameters demonstrated a P value less than .05 for 2 subject subsamples divided by age (≤52 vs >52 years), which means 6 VTI parameters change with age. CONCLUSIONS: VTI allows biomechanical and functional characterization of the vaginal conditions that can be used for (i) understanding "normal" vaginal conditions, (ii) quantification of the deviation from normality, (iii) personalized treatment (radiofrequency, laser, or plastic surgery), and (iv) assessment of the applied treatment outcome. Egorov V, Murphy M, Lucente V, et al. Quantitative Assessment and Interpretation of Vaginal Conditions. Sex Med 2018;6:39-48.

3.
Dig Dis Sci ; 63(1): 46-52, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29147876

RESUMO

BACKGROUND: Learning to perform colonoscopy safely and effectively is central to gastroenterology fellowship programs. The application of force to the colonoscope is an important part of colonoscopy technique. AIMS: We compared force application during colonoscopy between novice and expert endoscopists using a novel device to determine differences in colonoscopy technique. METHODS: This is an observational cohort study designed to compare force application during colonoscopy between novice and experienced trainees, made up of gastroenterology fellows from two training programs, and expert endoscopists from both academic and private practice settings. RESULTS: Force recordings were obtained for 257 colonoscopies by 37 endoscopists, 21 of whom were trainees. Experts used higher average forward forces during insertion compared to all trainees and significantly less clockwise torque compared to novice trainees. CONCLUSIONS: We present significant, objective differences in colonoscopy technique between novice trainees, experienced trainees, and expert endoscopists. These findings suggest that the colonoscopy force monitor is an objective tool for measuring proficiency in colonoscopy. Furthermore, the device may be used as a teaching tool in training and continued medical education programs.


Assuntos
Colonoscópios , Colonoscopia/métodos , Gastroenterologia/educação , Adulto , Idoso , Competência Clínica , Estudos de Coortes , Educação Médica Continuada , Educação de Pós-Graduação em Medicina , Desenho de Equipamento , Segurança de Equipamentos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica , Pressão , Estresse Mecânico
4.
Ann Biomed Eng ; 41(5): 1084-93, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23358801

RESUMO

Colonoscopy is the most sensitive and specific means for detection of colon cancers and polyps. To make colonoscopy more effective several problems must be overcome including: pain associated with the procedure, the risk of perforation, and incomplete intubation colonoscopy. Technically, these problems are the result of loop formation during colonoscopy. Although, several solutions such as modifying the stiffness of the colonoscope, using an overtube and developing image-guided instruments have been introduced to resolve the looping problem, the results of these systems are not completely satisfactory. A new paradigm to overcome loop formation is proposed that is doctor-assistive colonoscopy. In this approach, the endoscopists performance is enhanced by providing using a kinetic model that provides information such as the shape of the scope, direction of the colon and forces exerted within certain sections. It is expected that with the help of this model, the endoscopist would be able to adjust the manipulation to avoid loop formation. In the present studies, the kinetic model is developed and validated using an ex vivo colonoscopy test-bed with a comprehensive kinematic and kinetic data collection. The model utilizes an established colon model based on animal tissue with position tracking sensors, contact force sensors for the intraluminal portion of the scope and a Colonoscopy Force Monitor for the external insertion tube.


Assuntos
Colo , Colonoscópios , Colonoscopia/métodos , Modelos Biológicos , Animais , Colonoscopia/instrumentação , Humanos , Cinética , Suínos
5.
Gastrointest Endosc ; 71(2): 327-34, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19922923

RESUMO

BACKGROUND: To perform a colonoscopy, the endoscopist maneuvers the colonoscope through a series of loops by applying force to the insertion tube. Colonoscopy insertion techniques are operator dependent but have never been comprehensively quantified. OBJECTIVE: To determine whether the Colonoscopy Force Monitor (CFM), a device that continually measures force applied to the insertion tube, can identify different force application patterns among experienced endoscopists. DESIGN: Observational study of 6 experienced endoscopists performing routine diagnostic and therapeutic colonoscopy in 30 patients. SETTING: Outpatient ambulatory endoscopy center. PATIENTS: Adult male and female patients between 30 and 75 years of age undergoing routine colonoscopy. INTERVENTIONS: CFM monitoring of force applied to the colonoscope insertion tube during colonoscopy. MAIN OUTCOME MEASUREMENTS: Maximum and mean linear and torque force, time derivative of force, combined linear and torque vector force, and total manipulation time. RESULTS: The CFM demonstrates differences among endoscopists for maximum and average push/pull and mean torque forces, time derivatives of force, combined push/torque force vector, and total manipulation time. Endoscopists could be grouped by force application patterns. LIMITATIONS: Only experienced endoscopists using conscious sedation in the patients were studied. Sample size was 30 patients. CONCLUSIONS: This study demonstrates that CFM allows continuous force monitoring, characterization, and display of similarities and differences in endoscopic technique. CFM has the potential to facilitate training by enabling trainees to assess, compare, and quantify their techniques and progress.


Assuntos
Colonoscópios , Colonoscopia/métodos , Monitorização Fisiológica/instrumentação , Adulto , Idoso , Assistência Ambulatorial/métodos , Estudos de Coortes , Sedação Consciente/métodos , Desenho de Equipamento , Segurança de Equipamentos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Medição da Dor , Pressão , Probabilidade , Estresse Mecânico
6.
Breast Cancer Res Treat ; 118(1): 67-80, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19306059

RESUMO

Mechanical imaging yields tissue elasticity map and provides quantitative characterization of a detected pathology. The changes in the surface stress patterns as a function of applied load provide information about the elastic composition and geometry of the underlying tissue structures. The objective of this study is the clinical evaluation of breast mechanical imager for breast lesion characterization and differentiation between benign and malignant lesions. The breast mechanical imager includes a probe with pressure sensor array, an electronic unit providing data acquisition from the pressure sensors and communication with a touch-screen laptop computer. We have developed an examination procedure and algorithms to provide assessment of breast lesion features such as hardness related parameters, mobility, and shape. A statistical Bayesian classifier was constructed to distinguish between benign and malignant lesions by utilizing all the listed features as the input. Clinical results for 179 cases, collected at four different clinical sites, have demonstrated that the breast mechanical imager provides a reliable image formation of breast tissue abnormalities and calculation of lesion features. Malignant breast lesions (histologically confirmed) demonstrated increased hardness and strain hardening as well as decreased mobility and longer boundary length in comparison with benign lesions. Statistical analysis of differentiation capability for 147 benign and 32 malignant lesions revealed an average sensitivity of 91.4% and specificity of 86.8% with a standard deviation of +/-6.1%. The area under the receiver operating characteristic curve characterizing benign and malignant lesion discrimination is 86.1% with the confidence interval ranging from 80.3 to 90.9%, with a significance level of P = 0.0001 (area = 50%). The multisite clinical study demonstrated the capability of mechanical imaging for characterization and differentiation of benign and malignant breast lesions. We hypothesize that the breast mechanical imager has the potential to be used as a cost effective device for cancer diagnostics that could reduce the benign biopsy rate, serve as an adjunct to mammography and to be utilized as a screening device for breast cancer detection.


Assuntos
Doenças Mamárias/diagnóstico , Neoplasias da Mama/diagnóstico , Interpretação de Imagem Assistida por Computador/métodos , Exame Físico/métodos , Pressão , Estresse Mecânico , Adulto , Idoso , Algoritmos , Biópsia , Cisto Mamário/diagnóstico , Cisto Mamário/diagnóstico por imagem , Cisto Mamário/patologia , Doenças Mamárias/diagnóstico por imagem , Doenças Mamárias/patologia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Carcinoma/diagnóstico , Carcinoma/diagnóstico por imagem , Carcinoma/patologia , Diagnóstico Diferencial , Feminino , Fibroadenoma/diagnóstico , Fibroadenoma/diagnóstico por imagem , Fibroadenoma/patologia , Dureza , Humanos , Mamografia , Pessoa de Meia-Idade , Exame Físico/instrumentação , Curva ROC , Sensibilidade e Especificidade , Ultrassonografia Mamária
7.
Urology ; 71(3): 425-9, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18342178

RESUMO

OBJECTIVES: To evaluate the ability of prostate mechanical imaging (PMI) technology to provide an objective and reproducible image and to assess the prostate nodularity. METHODS: We evaluated the PMI device developed by Artann Laboratories in a pilot clinical study. For the 168 patients (ages 44 to 94) who presented to an urologist for prostate evaluation, PMI-produced images and assessment of prostate size, shape, consistency/hardness, mobility, and nodularity were compared with digital rectal examination (DRE) findings. The PMI and DRE results were further tested for correlation against a transrectal ultrasound of the prostate (TRUS) guided biopsy for a subgroup of 21 patients with an elevated prostate-specific antigen level. RESULTS: In 84% of the cases, the PMI device was able to reconstruct three-dimensional (3D) and 2D cross-sectional images of the prostate. The PMI System and DRE pretests were able to determine malignant nodules in 10 and 6 patients, respectively, of the 13 patients with biopsy-confirmed malignant inclusions. The PMI System findings were consistent with all 8 biopsy negative cases, whereas the DRE had 1 abnormal reading for this group. The correlation between PMI and DRE detection of palpable nodularity was 81%, as indicated by the area under the receiver operating characteristic curve. Estimates of the prostate size provided by PMI and DRE were statistically significantly correlated. CONCLUSIONS: The PMI has the potential to enable a physician to obtain, examine, and store a 3D image of the prostate based on mechanical and geometrical characteristics of the gland and its internal structures.


Assuntos
Próstata/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Técnicas de Diagnóstico Urológico/instrumentação , Desenho de Equipamento , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estresse Mecânico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA