Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 86
Filtrar
1.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38588039

RESUMO

AIMS: Phrenic nerve injury (PNI) is the most common complication during cryoballoon ablation. Currently, two cryoballoon systems are available, yet the difference is unclear. We sought to compare the acute procedural efficacy and safety of the two cryoballoons. METHODS: This prospective observational study consisted of 2,555 consecutive atrial fibrillation (AF) patients undergoing pulmonary vein isolation (PVI) using either conventional (Arctic Front Advance) (AFA-CB) or novel cryoballoons (POLARx) (POLARx-CB) at 19 centers between January 2022 and October 2023. RESULTS: Among 2,555 patients (68.8 ± 10.9 years, 1,740 men, paroxysmal AF[PAF] 1,670 patients), PVIs were performed by the AFA-CB and POLARx-CB in 1,358 and 1,197 patients, respectively. Touch-up ablation was required in 299(11.7%) patients. The touch-up rate was significantly lower for POLARx-CB than AFA-CB (9.5% vs. 13.6%, p = 0.002), especially for right inferior PVs (RIPVs). The touch-up rate was significantly lower for PAF than non-PAF (8.8% vs. 17.2%, P < 0.001) and was similar between the two cryoballoons in non-PAF patients. Right PNI occurred in 64(2.5%) patients and 22(0.9%) were symptomatic. It occurred during the right superior PV (RSPV) ablation in 39(1.5%) patients. The incidence was significantly higher for POLARx-CB than AFA-CB (3.8% vs. 1.3%, P < 0.001) as was the incidence of symptomatic PNI (1.7% vs. 0.1%, P < 0.001). The difference was significant during RSPV (2.5% vs. 0.7%, P < 0.001) but not RIPV ablation. The PNI recovered more quickly for the AFA-CB than POLARx-CB. CONCLUSIONS: Our study demonstrated a significantly higher incidence of right PNI and lower touch-up rate for the POLARx-CB than AFA-CB in the real-world clinical practice.


Assuntos
Fibrilação Atrial , Criocirurgia , Traumatismos dos Nervos Periféricos , Nervo Frênico , Veias Pulmonares , Sistema de Registros , Humanos , Nervo Frênico/lesões , Masculino , Feminino , Fibrilação Atrial/cirurgia , Fibrilação Atrial/epidemiologia , Veias Pulmonares/cirurgia , Idoso , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Estudos Prospectivos , Incidência , Traumatismos dos Nervos Periféricos/etiologia , Traumatismos dos Nervos Periféricos/epidemiologia , Traumatismos dos Nervos Periféricos/prevenção & controle , Pessoa de Meia-Idade , Resultado do Tratamento , Ablação por Cateter/efeitos adversos
2.
JSES Int ; 8(2): 349-354, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38464439

RESUMO

Background: Cardiac amyloidosis is a fatal disease of severe heart failure caused by the accumulation of amyloid in the myocardium. This disease is often advanced by the time cardiac symptoms appear; therefore, early detection and treatment are critical for a good prognosis. Recently, it has been suggested that cardiac amyloidosis is implicated in several orthopedic diseases, including carpal tunnel syndrome (CTS), which is often reported to precede cardiac dysfunction. Shoulder disease has also been suggested to be associated with cardiac amyloidosis; however, there have been no reports investigating the rate of amyloid deposition in shoulder specimens and the simultaneous prevalence of cardiac amyloidosis. Herein, we investigated the prevalence of intraoperative specimen amyloid deposition and cardiac amyloidosis in shoulder disease and CTS to determine the usefulness of shoulder specimen screening as a predictor of cardiac amyloidosis development. Methods: A total of 41 patients undergoing arthroscopic shoulder surgery and 33 patients undergoing CTS surgery were enrolled in this study. The shoulder group included rotator cuff tears, contracture of the shoulder, synovitis, and calcific tendonitis. In the shoulder group, a small sample of synovium and the long head of the biceps brachii tendon were harvested, while the transverse carpal ligament was harvested from the CTS group. The intraoperative specimens were pathologically examined for amyloid deposition, and patients with amyloid deposition were examined for the presence of cardiac amyloidosis by cardiac evaluation. Results: In the shoulder group, three cases (7.3%) of transthyretin amyloid deposition were found, all of which involved rotator cuff tears. None of these three cases with amyloid deposition were associated with cardiac amyloidosis. When examining the specimens, the amyloid deposition rate in the long head of the biceps brachii tendon was higher than that in the synovium. In the CTS group, 12 cases (36.4%) of transthyretin amyloid deposition were observed. Of these cases, seven underwent cardiac evaluation and two were identified with cardiac amyloidosis. Conclusion: While the prevalence of amyloid deposition and cardiac amyloidosis in the CTS group was consistent with previous reports, the shoulder group showed a lower deposition rate and no concomitant cardiac amyloidosis. Therefore, it remains debatable whether investigating amyloid deposition in samples obtained from shoulder surgery is beneficial for the early detection of cardiac amyloidosis.

3.
Quant Imaging Med Surg ; 14(1): 421-431, 2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-38223097

RESUMO

Background: Coronary flow reserve (CFR) provides prognostication and coronary physiological information, including epicardial coronary stenosis and microvascular function. The relationship between stress transthoracic Doppler echocardiography (TDE)-derived coronary flow velocity reserve (CFRS-TDE) and thermodilution-derived coronary flow reserve (CFRthermo) before and after elective percutaneous coronary intervention (PCI) remains unclear. Methods: This single-center prospective registry study evaluated patients who underwent fractional flow reserve (FFR)-guided elective PCI for left anterior descending artery (LAD) lesions with wire-based invasive physiological measurements and pre- and post-PCI stress TDE examinations. Results: A total of 174 LAD lesions from 174 patients were included in the final analysis. A modest correlation was detected between the pre-PCI CFRS-TDE and the pre-PCI CFRthermo (r=0.383, P<0.001). The frequently used CFRS-TDE threshold of 2.0 corresponded to a pre-PCI CFRthermo of 2.18. Pre-PCI CFRS-TDE underestimated pre-PCI CFRthermo [1.89 (1.44-2.31) vs. 2.05 (1.38-2.93), P<0.001]. Both CFRS-TDE and CFRthermo increased significantly post-PCI [pre-PCI CFRS-TDE 1.89 vs. post-PCI CFRS-TDE 2.33, P<0.001; pre-PCI CFRthermo 2.05 (1.38-2.93) vs. post-PCI CFRthermo 2.59 (1.63-3.55), P<0.001]. In contrast, there was no significant relationship between changes in CFRS-TDE and changes in CFRthermo after PCI (r=0.008, P=0.915) or between post-PCI CFRS-TDE and post-PCI CFRthermo (r=0.054, P=0.482). Conclusions: Pre-PCI CFRS-TDE and CFRthermo are modestly correlated, but post-PCI CFRS-TDE and CFRthermo have no correlation. CFRS-TDE and CFRthermo are not interchangeable, particularly post-PCI, suggesting that the two metrics represent different coronary physiologies after PCI.

4.
J Cardiovasc Electrophysiol ; 35(3): 505-510, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38178380

RESUMO

INTRODUCTION: Dual atrioventricular nodal non-reentrant tachycardia (DAVNNT) is a rare and challenging-to-diagnose arrhythmia, without previous reports associating it with a leftward inferior extension (LIE). METHODS: Diagnosis was made using adenosine triphosphate (ATP) injection during atrial pacing in a suspected DAVNNT patient. RESULTS: Ablation of the rightward inferior extension was unsuccessful in eliminating DAVNNT; however, subsequent ablation of the LIE successfully eradicated the arrhythmia. CONCLUSION: This unique case, marked by the first instance of DAVNNT caused by LIE, diagnosed through ATP injection, underscores the utility of this diagnostic approach and broadens the spectrum of our understanding and management of this condition.


Assuntos
Ablação por Cateter , Polifosfatos , Taquicardia por Reentrada no Nó Atrioventricular , Humanos , Trifosfato de Adenosina , Nó Atrioventricular , Ablação por Cateter/efeitos adversos , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Adenosina , Arritmias Cardíacas , Eletrocardiografia
5.
J Cardiovasc Electrophysiol ; 35(1): 198-205, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38037864

RESUMO

INTRODUCTION: The major limitation of the current cryoballoon (CB) system is a fixed 28 mm balloon-size. We sought to analyze real-world early experience with novel-sized adjustable CB. METHODS: This multicenter observational study included 140 consecutive atrial fibrillation patients (71 years, 94 men, 86 paroxysmal) who underwent pulmonary vein (PV) isolation using expandable diameter CB capable of ablation at 28 or 31 mm. RESULTS: Out of 544 targeted PVs, 526 (96.7%) were successfully isolated by a size-adjustable CB with a 770 [690-870] second median application dose, while the remaining 18 required touch-up ablation. Among them, 326 (62.0%) PVs were isolated by a 31 mm balloon, and the rate was significantly higher for upper than lower PVs (73.0% vs. 45.7%, p < .0001) and highest for right superior (78.5%) and lowest for right inferior (39.9%) PVs. The biophysical parameters and time to isolation were comparable between the 28 and 31 mm balloons, however, the real-time PV potential monitoring capability was significantly higher for 31 mm than 28 mm balloons for the left superior PV. The esophageal temperature reached 15°C during left inferior PV ablation significantly more often with 31 mm than 28 mm balloons (43.1% vs. 18.2%, p = .008). Right phrenic nerve injury (PNI) occurred in 9 (6.4%) patients during applications (6 right superior, 2 right inferior PVs), and most occurred with a 31 mm balloon. CONCLUSIONS: Our real-world early data demonstrated high acute efficacy and safety of the novel-sized adjustable CB. The biophysical parameters were similar between the 28 and 31 mm balloons. No marked decrease in the incidence of PNI was observed even with 31 mm balloons.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Masculino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/epidemiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Veias Pulmonares/cirurgia , Resultado do Tratamento , Feminino
6.
J Interv Card Electrophysiol ; 67(1): 5-12, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38087145

RESUMO

BACKGROUND: Single-shot pulmonary vein isolation (PVI) utilizing cryothermal energy is an effective and safe treatment for atrial fibrillation (AF) patients. A novel cryoballoon system, POLARx™, has been recently introduced. The aim of this study was to compare the efficacy, safety, and biophysical parameters of PVI between the novel cryoballoon system, POLARx™, and the standard cryoballoon system, Arctic Front Advance Pro™ (AFA-Pro), in patients with paroxysmal AF. METHODS: The CONTRAST-CRYO trial is a prospective, multicenter, open-label, randomized controlled study performed at seven large cardiac centers. This study was approved by the central ethics committee or the local ethics committee of each participating hospital and has been registered at UMIN Clinical Trials Registry (UMIN000049948). The trial will assign 200 patients with paroxysmal AF undergoing PVI to POLARx™ and AFA-Pro in a 1:1 randomization. The primary endpoint is the one-shot acute success rate of the right inferior pulmonary vein. Second endpoints include freedom from documented atrial fibrillation, atrial flutter, or atrial tachycardia without antiarrhythmic drugs at 12 months after the procedure, freedom from re-do procedures, the incidence of procedure-related adverse events, freezing duration, and the biophysical parameters during applications for each PV, total procedure and fluoroscopy time, and PVI durability during re-do procedures. CONCLUSION: The CONTRAST-CRYO trial is a prospective, multicenter, randomized study designed to elucidate the difference in the efficacy, safety, and biophysical parameters between POLARx™ and AFA-Pro in paroxysmal AF patients undergoing PVI. The findings from this trial may provide a valuable indication for selecting the optimal cryoballoon system. CLINICAL TRIAL REGISTRATION:  UMIN000049948.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Fibrilação Atrial/epidemiologia , Resultado do Tratamento , Estudos Prospectivos , Criocirurgia/métodos , Antiarrítmicos , Veias Pulmonares/cirurgia , Ablação por Cateter/métodos , Recidiva , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos Multicêntricos como Assunto
7.
J Obstet Gynaecol Res ; 50(1): 128-132, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37857437

RESUMO

Limited data have been reported on the use of proprotein convertase subtilisin/kexin type 9 (PCSK 9) inhibitors during pregnancy in women with familial hypercholesterolemia (FH). Here, we present the first case of initiating evolocumab (PCSK9 inhibitor) in a compound heterozygous FH mother. The patient was a 34-year-old primipara with severe dyslipidemia and a history of coronary artery bypass surgery. An elevated low-density lipoprotein cholesterol (LDL-C) level of 420 mg/dL was detected in the first trimester and persistently increased throughout pregnancy. Evolocumab was administered at 31 and 35 weeks of gestation, showing a positive effect on stabilizing LDL-C levels. Planned delivery with labor analgesia was performed at 38 + 4 weeks. Both the mother and infant were discharged without any notable complications. Hence, evolocumab, an IgG2 monochromatic antibody with little placental permeability, may be an alternative medication with limited influence on infants. Further studies are needed to assess the safety of evolocumab administration during pregnancy.


Assuntos
Doença da Artéria Coronariana , Hiperlipoproteinemia Tipo II , Gravidez , Feminino , Humanos , Adulto , LDL-Colesterol/uso terapêutico , Inibidores de PCSK9 , Pró-Proteína Convertase 9/uso terapêutico , Doença da Artéria Coronariana/tratamento farmacológico , Anticorpos Monoclonais/efeitos adversos , Placenta , Hiperlipoproteinemia Tipo II/complicações , Hiperlipoproteinemia Tipo II/tratamento farmacológico
8.
Pacing Clin Electrophysiol ; 47(1): 124-126, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37864811

RESUMO

Recently, a novel size-adjustable cryoballoon has been introduced in clinical practice, which can be inflated to two different diameters (28 and 31 mm). The 31 mm cryoballoon is specifically designed to achieve better contact with remodeled pulmonary veins (PVs) that have wider ostia while avoiding deep cannulation, thereby potentially reducing the risk of phrenic nerve injury (PNI) associated with deep balloon cannulation. However, we encountered two cases of PNI during cryoballoon ablation using the novel system among our initial 25 consecutive case series. Herein, we present two cases that exhibited PNI during freezing of the right superior PV with a size-adjustable balloon. While larger balloons are expected to create a larger area of isolation, the safety of this novel balloon system needs to be evaluated in a large-scale clinical study.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Traumatismos dos Nervos Periféricos , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Nervo Frênico/lesões , Traumatismos dos Nervos Periféricos/etiologia , Traumatismos dos Nervos Periféricos/prevenção & controle , Traumatismos dos Nervos Periféricos/cirurgia , Veias Pulmonares/cirurgia , Resultado do Tratamento
9.
Ann Nucl Cardiol ; 9(1): 11-18, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38058573

RESUMO

Background: Single-photon emission computed tomography (SPECT) encounters difficulties in diagnosing severe multi-vessel coronary artery disease (svMVD) because of balanced ischemia. We estimated the predictive value of electrocardiogram-gated SPECT for svMVD and improved it using machine learning (ML). Methods and results: We enrolled consecutive 335 patients (median age, 74 years; 255 men) who underwent adenosine stress-gated SPECT (99mTechnesium) and coronary angiography. svMVD was defined as three-vessel disease or left main tract stenosis. Predictive models were constructed using statistical and ML methods. Eighteen cases (5%) showed svMVD, and diabetes, summed stress score (SSS), and the max difference among segmental time of stroke volume per cardiac cycle (MDSV: a parameter of left ventricular [LV] end-systolic dyssynchrony) on adenosine stress were independent significant predictors. The area under the receiver operating characteristic curve (AUC) of SSS and MDSV on stress were 0.759 and 0.763, respectively. Conversely, the extra trees classifier and light gradient boosting machine had improved AUC values of 0.826 and 0.870, respectively, and the MDSV on stress and diabetes showed high feature values in the ML models. Conclusion: ML on SPECT helped to improve the diagnostic performance of svMVD and diabetes, and the parameters of LV dyssynchrony played essential roles in the ML predictive models.

10.
Quant Imaging Med Surg ; 13(12): 8423-8434, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38106253

RESUMO

Background: Computed tomography myocardial perfusion (CT-MP) has reported usefulness in assessing hemodynamically significant epicardial coronary artery lesions. However, the diagnostic ability of the absolute coronary flow using CT-MP to detect coronary microvascular dysfunction (CMD) remains elusive. This prospective cohort study aimed to assess the diagnostic value of CT-MP in evaluating coexisting CMD in patients with functionally significant epicardial coronary stenosis and to analyze the predictive factors of lesions with CMD. Methods: Sixty-eight patients with chronic coronary syndrome (CCS) and de novo single functionally significant stenosis [fractional flow reserve (FFR) ≤0.80] were studied. CMD was defined as an index of microcirculatory resistance ≥25. We compare clinical background and CT-MP findings between patients with and without CMD (CMD, n=29; non-CMD, n=39). CT-MP, and quantitative and qualitative plaque assessments were included in computed tomography angiography assessment. Logistic regression analysis was performed to predict CMD. Results: FFR, invasive wire-derived coronary flow reserve (CFRwire) and index of microcirculatory resistance were 0.68 [interquartile range (IQR), 0.59-0.74], 1.71 (IQR, 1.24-2.88), and 22.6 (IQR, 15.1-34.5), respectively. The rest and hyperemic-myocardial blood flow (MBF) and CT-MP-derived CFR (CFRCT-MP) were 0.83 (0.64-1.03) mL/min/g, 2.14 (1.30-2.92) mL/min/g, and 2.19 (1.44-3.37), respectively. In the territories with CMD, hyperemic-MBF was significantly lower than in those without [1.68 (IQR, 0.84-2.44) vs. 2.31 (IQR, 1.67-3.34) mL/min/g, P=0.015] and the prevalence of CFRCT-MP <2.0 was higher in the lesions with CMD than in those without (62.1% vs. 28.2%, P=0.011), while FFR values were similar. Fibrofatty and necrotic core component volume was greater in the vessels with CMD than in those without [31.8 (IQR, 19.0-48.9) vs. 25.1 (IQR, 17.2-32.1) mm3, P=0.045]. Multivariable logistic regression analysis showed that hyperemic-MBF and fibrofatty and necrotic core component volume were independent predictors of CMD territories [odds ratio (OR) =0.583; 95% confidence interval (CI): 0.355-0.958; P=0.033 and OR =1.040; 95% CI: 1.010-1.070; P=0.011]. Conclusions: Quantitative assessment of absolute coronary flow using pre-percutaneous coronary intervention (PCI) CT-MP, and comprehensive plaque analysis using computed tomography angiography may help detect coexisting subtended microvascular dysfunction in territories with functionally significant epicardial coronary lesions. Further studies are required to elucidate the clinical significance of coexisting CMD in patients with CCS undergoing PCI.

11.
Front Cardiovasc Med ; 10: 1278603, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37965084

RESUMO

Background: Symptomatic gastric hypomotility (SGH) is a rare but major complication of atrial fibrillation (AF) ablation, but data on this are scarce. Objective: We compared the clinical course of SGH occurring with different energy sources. Methods: This multicenter study retrospectively collected the characteristics and clinical outcomes of patients with SGH after AF ablation. Results: The data of 93 patients (67.0 ± 11.2 years, 68 men, 52 paroxysmal AF) with SGH after AF ablation were collected from 23 cardiovascular centers. Left atrial (LA) ablation sets included pulmonary vein isolation (PVI) alone, a PVI plus a roof-line, and an LA posterior wall isolation in 42 (45.2%), 11 (11.8%), and 40 (43.0%) patients, respectively. LA ablation was performed by radiofrequency ablation, cryoballoon ablation, or both in 38 (40.8%), 38 (40.8%), and 17 (18.3%) patients, respectively. SGH diagnoses were confirmed at 2 (1-4) days post-procedure, and 28 (30.1%) patients required re-hospitalizations. Fasting was required in 81 (92.0%) patients for 4 (2.5-5) days; the total hospitalization duration was 11 [7-19.8] days. After conservative treatment, symptoms disappeared in 22.3% of patients at 1 month, 48.9% at 2 months, 57.6% at 3 months, 84.6% at 6 months, and 89.7% at 12 months, however, one patient required surgery after radiofrequency ablation. Symptoms persisted for >1-year post-procedure in 7 patients. The outcomes were similar regardless of the energy source and LA lesion set. Conclusions: The clinical course of SGH was similar regardless of the energy source. The diagnosis was often delayed, and most recovered within 6 months, yet could persist for over 1 year in 10%.

12.
Int J Angiol ; 32(4): 288-291, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37927830

RESUMO

Vascular closing devices (VCDs) are widely used to replace manual compression at the femoral puncture site after catheter insertion. Perclose ProGlide is a suture-medicated VCD that is indicated for both arterial and venous access sites. However, there are few reports of complications related to venous use of ProGlide. Here, we describe a case of femoral vein stenosis caused by a suture-medicated VCD after an ablation procedure, which developed refractory deep vein thrombosis even after surgical vascular repair.

13.
J Cardiovasc Electrophysiol ; 34(12): 2484-2492, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37752712

RESUMO

INTRODUCTION: Cryoballoon ablation (CBA) of the left atrial (LA) roof in addition to a pulmonary vein isolation has been expected to improve the clinical outcomes post-atrial fibrillation (AF) ablation. We demonstrated the characteristics and efficacy of CBA of the LA roof through our experience with a large volume of procedures. METHODS: Among 1036 AF ablation procedures with CBA of the LA roof, 834 patients who underwent a de novo ablation were analyzed. RESULTS: Complete LA roof line conduction block was obtained in 767 patients (92.0%) solely by CBA (Group A). Compared with the other patients (Group B), the mean nadir balloon temperature during CBA of the LA roof (-44.5 ± 5.6°C for Group A vs. -40.5 ± 7.5°C for Group B, p < .01) and number of cryoballoon applications during the LA roof ablation with a circular mapping catheter located in the left superior pulmonary vein (1.3 ± 0.8 for Group A vs. 1.6 ± 1.0 for Group B, p = .02) were significantly lower in Group A. A multivariate analysis revealed that those were predictors of a complete LA roof conduction block after only CBA. The 1-year Kaplan-Meier atrial arrhythmia free rate estimates were 80.6% for Group A and 59.0% for Group B (p < .01). CONCLUSION: Complete LA roof line conduction block could be obtained with a cryoballoon without touch-up ablation in most cases. The LA roof CBA with a circular mapping catheter located in the right superior pulmonary vein was preferable to obtaining complete LA roof conduction block, which was important with regard to the clinical outcomes.


Assuntos
Fibrilação Atrial , Bloqueio Atrioventricular , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Átrios do Coração/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Recidiva
14.
Int J Oral Sci ; 15(1): 42, 2023 09 18.
Artigo em Inglês | MEDLINE | ID: mdl-37723152

RESUMO

While several previous studies have indicated the link between periodontal disease (PD) and myocardial infarction (MI), the underlying mechanisms remain unclear. Autophagy, a cellular quality control process that is activated in several diseases, including heart failure, can be suppressed by Porphyromonas gingivalis (P.g.). However, it is uncertain whether autophagy impairment by periodontal pathogens stimulates the development of cardiac dysfunction after MI. Thus, this study aimed to investigate the relationship between PD and the development of MI while focusing on the role of autophagy. Neonatal rat cardiomyocytes (NRCMs) and MI model mice were inoculated with wild-type P.g. or gingipain-deficient P.g. to assess the effect of autophagy inhibition by P.g. Wild-type P.g.-inoculated NRCMs had lower cell viability than those inoculated with gingipain-deficient P.g. This study also revealed that gingipains can cleave vesicle-associated membrane protein 8 (VAMP8), a protein involved in lysosomal sensitive factor attachment protein receptors (SNAREs), at the 47th lysine residue, thereby inhibiting autophagy. Wild-type P.g.-inoculated MI model mice were more susceptible to cardiac rupture, with lower survival rates and autophagy activity than gingipain-deficient P.g.-inoculated MI model mice. After inoculating genetically modified MI model mice (VAMP8-K47A) with wild-type P.g., they exhibited significantly increased autophagy activation compared with the MI model mice inoculated with wild-type P.g., which suppressed cardiac rupture and enhanced overall survival rates. These findings suggest that gingipains, which are virulence factors of P.g., impair the infarcted myocardium by cleaving VAMP8 and disrupting autophagy. This study confirms the strong association between PD and MI and provides new insights into the potential role of autophagy in this relationship.


Assuntos
Ruptura Cardíaca , Doenças Periodontais , Camundongos , Ratos , Animais , Porphyromonas gingivalis , Cisteína Endopeptidases Gingipaínas , Autofagossomos , Miocárdio
15.
Pacing Clin Electrophysiol ; 46(6): 475-486, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37129189

RESUMO

BACKGROUNDS: Catheter ablation for non-paroxysmal atrial fibrillation (non-PAF) remains challenging and more effective strategy has been required to reduce postoperative arrhythmia recurrences. This study aims to investigate the efficacy and safety of a novel extensive ablation strategy for non-PAF, that is based on a combination of cryoballoon (CBA), radiofrequency (RFA), and Marshall-vein ethanol ablations (EA-VOM). METHODS: The study was a single-center, retrospective observational study. We enrolled 171 consecutive patients who underwent de-novo catheter ablation for non-PAF under conscious sedation with a novel extensive ablation strategy that included CBA for pulmonary vein isolation (PVI) and left atrial roof ablation (LARA), RFA for mitral isthmus (MI) ablation, superior vena cava isolation, and other linear ablations and EA-VOM. Recurrence of atrial arrhythmias over 1 year, procedure outcomes, and procedure-related complications were investigated. RESULTS: A total of 139 (81.3%) patients remained in sinus rhythm during 1-year follow-up. Of the 139 patients, 51 patients (29.8%) received antiarrhythmic drugs. The mean procedure time was 204 ± 45 min. PVI and LARA ablation by CBA and MI block by RFA and EA-VOM were completed in 171 (100%) and 166 (97.1%) patients, respectively. No serious procedure-related complications were observed except for one case of delayed pericardial effusion. CONCLUSION: Approximately 80% of the study patients were AF-free during 1-year follow-up period after a single procedure based on the novel extensive ablation strategy combining CBA, RFA, and EA-VOM. This strategy for non-PAF may be preferred in terms of maintenance of sinus rhythm, safety even in high-risk patients, and relatively short procedure time.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Etanol , Veia Cava Superior , Átrios do Coração , Veias Pulmonares/cirurgia , Criocirurgia/métodos , Ablação por Cateter/métodos , Resultado do Tratamento , Recidiva
17.
J Cardiol ; 81(1): 111-116, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36229301

RESUMO

BACKGROUND: As cardiac implantable electronic devices, such as pacemakers, cardioverter defibrillators, and cardiac resynchronization therapies, have become more popular, device extraction has become more frequent. At our institution, individual treatment strategies are discussed at a heart team meeting. Transvenous lead extraction (TVLE) is a first-line treatment; however, surgical lead extraction (SLE) is sometimes selected as a primary choice to provide optimal treatment and maintain the medical safety policy. This study aimed to investigate the validity of this heart team decision-making. METHODS: From 2013 to 2021, 384 consecutive patients underwent lead extraction at our institution. RESULTS: SLE was proposed as the primary intervention for 21 patients who had high risk of bleeding, difficult TVLE conditions, large vegetations, and other concomitant cardiac diseases. Of the 363 TVLE patients, 10 patients required surgical intervention; 5 had TVLE difficulty followed by SLE and 5 had excessive bleeding. SLE was performed in 26 patients, 19 of whom required valve surgery, and 8 required plication of the great veins. In 4 of the 17 hybrid procedures with SLE and TVLE, excessive bleeding occurred due to laceration of the superior vena cava and innominate vein. Operative mortality was not observed in SLE patients but was observed in 1 of the 4 TVLE patients who required emergent open-chest hemostasis. CONCLUSIONS: The heart team discussion was essential to provide optimal treatment and maintain medical safety policies for each patient. SLE should be selected for patients with high risk of TVLE or other cardiac complications such as tricuspid valve incompetence.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/métodos , Eletrônica , Marca-Passo Artificial/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Veia Cava Superior
18.
J Cardiovasc Electrophysiol ; 34(2): 478-482, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36579408

RESUMO

INTRODUCTION: Persistent left superior vena cava (PLSVC) is accompanied by enlarged coronary sinus (CS) and deformation of the triangle of Koch. This makes anatomical evaluation of the atrioventricular (AV) nodal pathways difficult. METHODS: We attempted cryoablation of retrograde fast pathway located in the enlarged CS roof of PLSVC for slow-fast AV nodal reentrant tachycardia (AVNRT) induced by inadvertent antegrade fast pathway elimination during ablation of left atrial tachycardia. RESULTS: Slow-fast AVNRT was successfully eliminated without AV block progression. CONCLUSIONS: This is the first case of successful retrograde fast pathway ablation of the CS ostial roof for slow-fast AVNRT with PLSVC.


Assuntos
Ablação por Cateter , Seio Coronário , Criocirurgia , Veia Cava Superior Esquerda Persistente , Taquicardia por Reentrada no Nó Atrioventricular , Humanos , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Seio Coronário/diagnóstico por imagem , Seio Coronário/cirurgia , Veia Cava Superior/diagnóstico por imagem , Veia Cava Superior/cirurgia
19.
ESC Heart Fail ; 10(2): 1426-1430, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36401586

RESUMO

A 44-year-old woman who was quarantined for 5 days after the diagnosis of coronavirus disease of 2019 (COVID-19) was transferred to our hospital with the complaint of chest pain. The patient was unvaccinated. Electrocardiography revealed ST elevation in the lateral leads. Echocardiographic biventricular dysfunction with oedematous wall thickening was identified. Cardiac enzyme levels were elevated; however, C-reactive protein (CRP) levels, and the coronary angiogram were normal. The patient required mechanical circulatory support to stabilize haemodynamics and was treated with remdesivir, baricitinib, and intravenous methylprednisolone. She recovered after 13 days of mechanical support. Serial cardiac magnetic resonance imaging revealed acute myocardial oedema and subsequent fibrosis. An endomyocardial biopsy on admission showed mild interstitial inflammatory infiltrates with endomyocardial fibrous thickening and mild interstitial fibrosis of the myocardium. Normal CRP levels suggested minor involvement of interleukin (IL)-6, supporting the efficacy of baricitinib.


Assuntos
COVID-19 , Miocardite , Feminino , Humanos , Adulto , Miocardite/complicações , Miocardite/diagnóstico , Proteína C-Reativa , COVID-19/complicações , Seguimentos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Fibrose
20.
Am Heart J Plus ; 30: 100298, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38510923

RESUMO

Background: Periodontal disease (PD) is associated with an increased risk of cardiovascular disease (CVD). Pericardial adipose tissue (PAT) is known as a marker of progressive CVD. This study sought to assess the association between PD and PAT in patients with CVD. Methods: We retrospectively investigated 135 patients admitted for CVD who underwent computed tomography coronary angiography (CTCA) and periodontal examinations. Periodontal assessment using the community periodontal index (CPI) was based on the probing pocket depth around teeth. Patients with CPI ≥3 were categorized as having PD. PAT volume was measured with a quantitative semi-automated procedure using CTCA images. Patients were divided into tertiles according to PAT volume. Baseline characteristics and PD findings were compared among the tertiles. Results: Eighty-six patients were diagnosed with PD (63.7 %). Mean PAT volume was 181.4 ml, and patients were categorized as small-PAT (PAT <148.9 ml), intermediate-PAT (148.9 ml ≤ PAT ≤204.6 ml), and large-PAT (PAT >204.6 ml). The prevalence of PD was significantly higher in large-PAT (38/46, 82.6 %) than in small-PAT (18/45, 40.0 %) and intermediate-PAT (30/44, 68.2 %) patients. Multivariate logistic regression analysis showed that body weight, history of hypertension, and the presence of PD were independent predictors for large-PAT (odds ratio [OR]: 1.12, P < 0.001, OR: 3.97, P = 0.017, and OR: 4.18, P = 0.0078, respectively). Conclusion: The presence and severity of PD were significantly correlated with PAT volume, which has been associated with progressive CVD. Further prospective studies are warranted to assess the impact of PD on the onset and outcomes of CVD.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA