Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Appl Radiat Isot ; 206: 111220, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38301319

RESUMO

44Sc is a ß+-emitter which has been extensively studied for nuclear medicine applications. Its promising decay characteristics [t1/2 = 3.97 h, E [Formula: see text] = 632 keV (94.3%), Eγ = 1157 keV (99.9%); 1499 keV (0.91%)] make it highly attractive for clinical PET imaging, offering an alternative to the widely used 68Ga [t1/2 = 67.7 min, E [Formula: see text] = 836 keV (87.7%)]. Notably, its nearly fourfold longer half-life opens avenues for applications with biomolecules having extended biological half-lives and enables the centralized distribution of 44Sc radiopharmaceuticals. An additional advantage of employing 44Sc as a diagnostic radioisotope lies in its counterpart, the ß--emitter 47Sc, which is currently under investigation for targeted radiotherapy. Together, they form an ideal theranostic pair, providing a comprehensive solution for both diagnostic imaging and therapeutic applications in nuclear medicine. At the Bern medical cyclotron, a study to optimize the production of scandium radioisotopes is currently ongoing. In this context, proton irradiation of titanium targets has been investigated, exploiting the reactions 47Ti(p,α)44Sc and 50Ti(p,α)47Sc. This approach enables the production of Sc radioisotopes within a single PET medical cyclotron facility, employing identical chemical procedures for target preparation and post-irradiation processing. In this paper, we report on cross-section measurements of the 47Ti(p,α)44Sc nuclear reaction using 95.7% enriched 47TiO2 targets. On the basis of the obtained results, the production yield and purity were calculated to assess the optimal irradiation conditions. Production tests were performed to confirm these findings.


Assuntos
Ciclotrons , Radioisótopos , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos , Escândio/química
2.
Appl Radiat Isot ; 200: 110954, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37527621

RESUMO

165Er is a pure Auger-electron emitter with promising characteristics for therapeutic applications in nuclear medicine. The short penetration path and high Linear Energy Transfer (LET) of the emitted Auger electrons make 165Er particularly suitable for treating small tumor metastases. Several production methods based on the irradiation with charged particles of Er and Ho targets can be found in the literature. In this paper, we report on the study of 165Er indirect production performed via the 166Er(p,2n)165Tm →165Er reaction at the 18 MeV Bern medical cyclotron. Despite the use of highly enriched 166Er2O3 targets, several Tm radioisotopes are produced during the irradiation, making the knowledge of the cross sections involved crucial. For this reason, a precise investigation of the cross sections of the relevant nuclear reactions in the energy range of interest was performed by irradiating Er2O3 targets with different isotopic enrichment levels and using a method based on the inversion of a linear system of equations. For the reactions 164Er(p, γ)165Tm, 166Er(p,n)166Tm, 166Er(p, γ)167Tm, 167Er(p,3n)165Tm, 167Er(p, γ)168Tm, 168Er(p,2n)167Tm and 170Er(p,3n)168Tm, the nuclear cross section was measured for the first time. From the results obtained, the production yield and purity of the parent radioisotope 165Tm were calculated to assess the optimal irradiation conditions. Several production tests with solid targets were performed to confirm these findings.

3.
Appl Radiat Isot ; 195: 110737, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36863264

RESUMO

RadioNuclide Therapy (RNT) in nuclear medicine is a cancer treatment based on the administration of radioactive substances that specifically target cancer cells in the patient. These radiopharmaceuticals consist of tumor-targeting vectors labeled with ß-, α, or Auger electron-emitting radionuclides. In this framework, 67Cu is receiving increasing interest as it provides ß--particles accompanied by low-energy γ radiation. The latter allows to perform Single Photon Emission Tomography (SPECT) imaging for detecting the radiotracer distribution for an optimized treatment plan and follow-up. Furthermore, 67Cu could be used as therapeutic partner of the ß+-emitters 61Cu and 64Cu, both currently under study for Positron Emission Tomography (PET) imaging, paving the way to the concept of theranostics. The major barrier to a wider use of 67Cu-based radiopharmaceutical is its lack of availability in quantities and qualities suitable for clinical applications. A possible but challenging solution is the proton irradiation of enriched 70Zn targets, using medical cyclotrons equipped with a solid target station. This route was investigated at the Bern medical cyclotron, where an 18 MeV cyclotron is in operation together with a solid target station and a 6-m-long beam transfer line. The cross section of the involved nuclear reactions were accurately measured to optimize the production yield and the radionuclidic purity. Several production tests were performed to confirm the obtained results.


Assuntos
Ciclotrons , Radioisótopos , Humanos , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos/uso terapêutico , Tomografia Computadorizada de Emissão de Fóton Único
4.
Appl Radiat Isot ; 191: 110518, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36327610

RESUMO

Radiometals play a fundamental role in the development of personalized nuclear medicine. In particular, copper radioisotopes are attracting increasing interest since they offer a varying range of decay modes and half-lives and can be used for imaging (60Cu, 61Cu, 62Cu and 64Cu) and targeted radionuclide therapy (64Cu and 67Cu), providing two of the most promising true theranostic pairs, namely 61Cu/67Cu and 64Cu/67Cu. Currently, the most widely used in clinical applications is 64Cu, which has a unique decay scheme featuring ß+-, ß--decay and electron capture. These characteristics allow its exploitation in both diagnostic and therapeutic fields. However, although 64Cu has extensively been investigated in academic research and preclinical settings, it is still scarcely used in routine clinical practice due to its insufficient availability at an affordable price. In fact, the most commonly used production method involves proton irradiation of enriched 64Ni, which has a very low isotopic abundance and is therefore extremely expensive. In this paper, we report on the study of two alternative production routes, namely the 65Cu(p,pn)64Cu and 67Zn(p, α)64Cu reactions, which enable low and high 64Cu specific activities, respectively. To optimize the 64Cu production, while minimizing the mass of copper used as a target in the first case, or the co-production of other copper radioisotopes in the second case, an accurate knowledge of the production cross sections is of paramount importance. For this reason, the involved nuclear reaction cross sections were measured at the Bern medical cyclotron laboratory by irradiating enriched 65CuO and enriched 67ZnO targets. On the basis of the obtained results, the production yield and purity were calculated to assess the optimal irradiation conditions. Several production tests were performed to confirm these findings.


Assuntos
Radioisótopos de Cobre , Ciclotrons , Medicina de Precisão , Cobre , Diagnóstico por Imagem/métodos , Compostos Radiofarmacêuticos/uso terapêutico
5.
Appl Radiat Isot ; 189: 110428, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36049443

RESUMO

The availability of novel radionuclides plays a fundamental role in the development of personalized nuclear medicine. In particular, there is growing interest in pairs formed by two radioisotopes of the same element, the so-called true theranostic pairs, such as 61,64Cu/67Cu, 43,44Sc/47Sc and 155Tb/149,161Tb. In this case, the two radionuclides have identical kinetics and chemical reactivity, allowing to predict whether the patient will benefit from a therapeutic treatment on the basis of nuclear imaging data. 47Sc [t1/2 = 3.349 d, E [Formula: see text] = 440.9 keV (68.4%); 600.3 keV (31.6%), Eγ = 159.4 keV (68.3%)] is a promising radionuclide for theranostic applications in nuclear medicine. Its physical characteristics make it suitable for radionuclide therapy and allow SPECT imaging during treatment. Moreover, 47Sc is foreseen as the therapeutic partner of the ß+-emitters 43Sc and 44Sc, both under study for PET imaging, opening new avenues towards the true theranostics concept. 47Sc can be produced by proton irradiation of an enriched 50Ti oxide target with a medical cyclotron equipped with a solid target station. To optimize the production yield and the radionuclidic purity, an accurate knowledge of the production cross sections is necessary. In this paper, we report on measurements of the production cross section of 47Sc and 46Sc using enriched 50Ti titanium oxide targets, performed at the Bern University Hospital cyclotron laboratory. On the basis of the obtained results, a study of the production yield and purity was performed to assess the optimal irradiation conditions. A production test was also carried out to confirm these findings.


Assuntos
Ciclotrons , Escândio , Humanos , Óxidos , Tomografia por Emissão de Pósitrons/métodos , Prótons , Radioisótopos
6.
J Radiat Res ; 49(6): 597-607, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18987438

RESUMO

This work aimed at measuring cell-killing effectiveness of monoenergetic and Spread-Out Bragg Peak (SOBP) carbon-ion beams in normal and tumour cells with different radiation sensitivity. Clonogenic survival was assayed in normal and tumour human cell lines exhibiting different radiosensitivity to X- or gamma-rays following exposure to monoenergetic carbon-ion beams (incident LET 13-303 keV/microm) and at various positions along the ionization curve of a therapeutic carbon-ion beam, corresponding to three dose-averaged LET (LET(d)) values (40, 50 and 75 keV/microm). Chinese hamster V79 cells were also used. Carbon-ion effectiveness for cell inactivation generally increased with LET for monoenergetic beams, with the largest gain in cell-killing obtained in the cells most radioresistant to X- or gamma-rays. Such an increased effectiveness in cells less responsive to low LET radiation was found also for SOBP irradiation, but the latter was less effective compared with monoenergetic ion beams of the same LET. Our data show the superior effectiveness for cell-killing exhibited by carbon-ion beams compared to lower LET radiation, particularly in tumour cells radioresistant to X- or gamma-rays, hence the advantage of using such beams in radiotherapy. The observed lower effectiveness of SOBP irradiation compared to monoenergetic carbon beam irradiation argues against the radiobiological equivalence between dose-averaged LET in a point in the SOBP and the corresponding monoenergetic beams.


Assuntos
Apoptose/efeitos da radiação , Isótopos de Carbono , Sobrevivência Celular/efeitos da radiação , Íons Pesados , Neoplasias/patologia , Neoplasias/fisiopatologia , Relação Dose-Resposta à Radiação , Humanos , Doses de Radiação , Espalhamento de Radiação
7.
Mutat Res ; 596(1-2): 151-65, 2006 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-16460768

RESUMO

Inheritable chromosome aberrations (CA) are of concern because cytogenetic damage may trigger the carcinogenic process. Moreover, stability of radiation-induced CA is a prerequisite for meaningful biological dosimetry. CA inheritability arguably depends on the aberration structure, with symmetrical exchanges being favoured over asymmetrical rearrangements, but it is also affected by radiation quality. CA induced by low-LET protons and high-LET 12C ions in G0 peripheral blood lymphocytes were measured in first- , second- and third-generation by combined FISH/harlequin staining of metaphase as well as prematurely condensed interphase chromosomes 1 and 2. As expected, the frequency of non-transmissible (NT) aberrations declined through replication rounds. A radiation-induced arrest occurred prior to first post-irradiation mitosis that prevalently affected aberrant cells. Aberrant cells incurred cycle delays also at subsequent cycles following proton-irradiation but not 12C ion-irradiation. As expected, the frequency of reciprocal translocations remained fairly stable while that of dicentrics was halved at each mitotic round. A significant fraction of complex-type exchanges was found in third-generation cells following both irradiations and appeared to be transmitted relatively more efficiently after protons than 12C ions. A low but stably transmitted frequency of transmissible (T)-type insertions were detected after 12C ions but not after low LET-irradiation. Our data support a differential ability by aberrant cells to progress through post-irradiation mitoses that is influenced by the aberration burden and radiation quality.


Assuntos
Aberrações Cromossômicas , Interfase/genética , Transferência Linear de Energia , Linfócitos/citologia , Linfócitos/efeitos da radiação , Metáfase/genética , Carbono , Divisão Celular , Humanos , Hibridização in Situ Fluorescente , Técnicas In Vitro , Mutação
8.
Radiother Oncol ; 73 Suppl 2: S130-3, 2004 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-15971328

RESUMO

Radiobiological studies with proton beams started in the first half of the last century, when the scientific community could profit of the Lawrence idea to accelerate protons. It became soon clear that such a radiation could be favourably used in clinical applications. Since then, the biological effects of protons have been deeply investigated, in a wide energy range and several biological end-points have been studied. Nowadays a partially overlapping research field is expanding aiming at radioprotection of astronauts, a major concern because long-term manned space missions are foreseen.


Assuntos
Prótons , Animais , Sobrevivência Celular/efeitos da radiação , Humanos , Transferência Linear de Energia , Aceleradores de Partículas , Tolerância a Radiação , Eficiência Biológica Relativa
9.
Int J Radiat Oncol Biol Phys ; 57(3): 732-8, 2003 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-14529778

RESUMO

PURPOSE: To measure chromosomal aberrations in blood lymphocytes from breast cancer patients treated with radiotherapy after quadrantectomy or tumorectomy. METHODS AND MATERIALS: Twenty-two breast cancer patients treated with breast-conserving surgery and radiation were evaluated. Adjuvant chemotherapy was also given to 9 patients. Blood samples were obtained before radiotherapy, after about one-half of the fractions, and at the end of the treatment of the whole breast (50 Gy). Chromosome aberrations in peripheral blood lymphocytes were measured using chemical-induced premature chromosome condensation combined with fluorescence in situ hybridization. RESULTS: Radiation treatment produced a significant increase in the yield of chromosomal aberrations. A large interindividual variability was observed. The variability was not related to field size, previous chemotherapy, or treatment morbidity. Chromosome aberrations in lymphocytes at the end of the treatment were significantly higher in the group of patients with no lymph nodes surgically removed before the treatment than in the group of patients with more than 10 lymph nodes removed. CONCLUSION: The number of lymph nodes within the radiation field is an important factor affecting the yield of radiation-induced chromosomal aberrations in breast cancer patients.


Assuntos
Neoplasias da Mama/radioterapia , Aberrações Cromossômicas , Linfonodos/efeitos da radiação , Linfócitos/efeitos da radiação , Protocolos de Quimioterapia Combinada Antineoplásica/administração & dosagem , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/genética , Neoplasias da Mama/cirurgia , Quimioterapia Adjuvante , Cisplatino/administração & dosagem , Feminino , Fluoruracila/administração & dosagem , Humanos , Excisão de Linfonodo , Mastectomia Segmentar , Metotrexato/administração & dosagem
10.
J Radiat Res ; 43 Suppl: S107-11, 2002 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-12793741

RESUMO

Computer code calculations based on biophysical models are commonly used to evaluate the effectiveness of shielding in reducing the biological damage caused by cosmic radiation in space flights. Biological measurements are urgently needed to benchmark the codes. We have measured the induction of chromosomal aberrations in human peripheral blood lymphocytes exposed in vitro to 56Fe-ion beams accelerated at the HIMAC synchrotron in Chiba. Isolated lymphocytes were exposed to the 500 MeV/n iron beam (dose range 0.1-1 Gy) after traversal of 0 to 8 g/cm2 of either PMMA (lucite, a common plastic material) or aluminum. Three PMMA shield thickness and one Al shield thickness were used. For comparison, cells were exposed to 200 MeV/n iron ions and to X-rays. Chromosomes were prematurely condensed by a phosphatase inhibitor (calyculin A) to avoid cell-cycle selection produced by the exposure to high-LET heavy ion beams. Aberrations were scored in chromosomes 1, 2, and 4 following fluorescence in situ hybridization. The yield of chromosomal aberrations per unit dose at the sample position was poorly dependent on the shield thickness and material. However, the yield of aberrations per unit ion incident on the shield was increased by the shielding. This increase is associated to the increased dose-rate measured behind the shield as compared to the direct beam. These preliminary results prove that shielding can increase the effectiveness of heavy ions, and the damage is dependent upon shield thickness and material.


Assuntos
Aberrações Cromossômicas , Íons Pesados , Ferro , Linfócitos/efeitos da radiação , Proteção Radiológica , Adulto , Alumínio , Células Sanguíneas/efeitos da radiação , Cromossomos/efeitos da radiação , Desenho de Equipamento , Humanos , Masculino , Aceleradores de Partículas , Polimetil Metacrilato , Proteção Radiológica/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA