Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
PLoS Negl Trop Dis ; 17(7): e0011465, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37410782

RESUMO

BACKGROUND: Female Genital Schistosomiasis (FGS) is a neglected disease of the genital tract due to the inflammatory response to the presence of Schistosoma haematobium eggs in the genital tract. The WHO has prioritized the improvement of diagnostics for FGS and previous studies have explored the PCR-based detection of Schistosoma DNA on genital specimens, with encouraging results. This study aimed to determine the prevalence of FGS among women living in an endemic district in North-western Tanzania, using PCR on samples collected though cervical-vaginal swabs, and to compare the performance of self-collected and healthcare worker-collected (operator-collected) samples, and the acceptability of the different sampling methods. METHODS/PRINCIPAL FINDINGS: A cross-sectional study was conducted involving 211 women living in 2 villages in the Maswa district of North-western Tanzania. Urine, self-collected and operator-collected cervical-vaginal swabs were obtained from participants. A questionnaire was administered, focusing on the comfortability in undergoing different diagnostic procedures. Prevalence of urinary schistosomiasis, as assessed by eggs in urine, was 8.5% (95%CI 5.1-13.1). DNA was pre-isolated from genital swabs and transported at room temperature to Italy for molecular analysis. Prevalence of active schistosomiasis, urinary schistosomiasis, and FGS were 10.0% (95% CI 6.3-14.8), 8.5% (95%CI 5.1-13.1), and 4.7% (95%CI 2.3-8.5), respectively. When real-time PCR was performed after a pre-amplification step, the prevalence of active schistosomiasis increased to 10.4% (95%CI 6.7-15.4), and FGS to 5.2% (95%CI 2.6-9.1). Of note, more cases were detected by self-collected than operator-collected swabs. The vast majority of participants (95.3%) declared that they were comfortable/very comfortable about genital self-sampling, which was indicated as the preferred sampling method by 40.3% of participants. CONCLUSIONS/SIGNIFICANCE: The results of this study show that genital self-sampling followed by pre-amplified PCR on room temperature-stored DNA is a useful method from both technical and acceptability point of views. This encourages further studies to optimize samples processing, and identify the best operational flow to allow integration of FGS screening into women health programmes, such as HPV screening.


Assuntos
Genitália Feminina , Esquistossomose Urinária , Animais , Feminino , Humanos , Masculino , Prevalência , Tanzânia/epidemiologia , Estudos Transversais , Esquistossomose Urinária/diagnóstico , Esquistossomose Urinária/epidemiologia , Esquistossomose Urinária/urina , Schistosoma haematobium/genética , Reação em Cadeia da Polimerase em Tempo Real
2.
Infection ; 51(5): 1249-1271, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37420083
3.
J Clin Med ; 12(2)2023 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-36675507

RESUMO

Ruxolitinib is a JAK1/2 inhibitor that has revolutionized the approach to myelofibrosis. On the one side, this drug can rapidly improve the symptoms related to the hematological disease; on the other side, the inhibition of JAK1/2 can lead to immunosuppression which may increase the risk of infections, due to a change in the cytokine balance in favor of anti-inflammatory cytokines, to direct inhibition of immune cells, and to the suppression in the production of specific antibodies. In this patient setting, much is known about possible viral and bacterial infections, while little is reported in the literature concerning parasitic infections, specifically leishmaniasis. Leishmania is a parasitic infection that can cause serious problems in immunosuppressed patients. The parasite can invade the bloodstream and cause a wide range of symptoms, including fever, weight loss, and anemia. In severe cases, it can lead to multi-organ failure and, rapidly, death. Early diagnosis and prompt treatment are essential especially for these patients, unable to respond adequately. In this case and the following review of the existing literature, the cytokine kinetics and the production of specific anti-Leishmania antibodies represent characteristic aspects capable of providing a more in-depth understanding of the mechanisms underlying these complex clinical cases in an immunocompromised patient.

4.
Diagnostics (Basel) ; 11(2)2021 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-33503986

RESUMO

The differential diagnosis of hepatic cystic echinococcosis (CE) may be challenging. When imaging is insufficient, serology can be applied, but no consensus diagnostic algorithm exists. We evaluated the performances of nine serological tests commercialized in Europe for the diagnosis of "echinococcosis". We performed a diagnostic accuracy study using a panel of sera from patients with hepatic CE (n = 45 "liquid" content stages, n = 25 "solid" content stages) and non-CE focal liver lesions (n = 54 with "liquid" content, n = 11 with "solid" content). The diagnosis and staging of CE were based on ultrasound (gold standard). Nine commercial seroassays (5 ELISA, 2 WB, 1 Chemiluminescence Immunoassay [CLIA] and 1 Immunochromatographic test [ICT]) were the index tests. Sensitivity (Se) ranged from 43 to 94% and from 31 to 87%, and specificity (Sp) from 68 to 100% and from 94 to 100%, when borderline results were considered positive or negative, respectively. Three seroassays (2 ELISA, 1 WB) were excluded from further analyses due to poor performances. When tests were combined, Sp was 98-100%. The best results were obtained using the WB-LDBIO alone (Se 83%) or as a third test after two non-WB tests (Se 67-86%). A validated WB or two non-WB tests, read with stringent criteria (borderline = negative and considered positive only if concordant positive), possibly confirmed by the WB, appear sensible approaches.

5.
Sci Rep ; 10(1): 18764, 2020 10 30.
Artigo em Inglês | MEDLINE | ID: mdl-33127953

RESUMO

Droplet digital PCR (ddPCR) is a sensitive and reproducible technology widely used for quantitation of several viruses. The aim of this study was to evaluate the 2019-nCoV CDC ddPCR Triplex Probe Assay (BioRad) performance, comparing the direct quantitation of SARS-CoV-2 on nasopharyngeal swab with the procedure applied to the extracted RNA. Moreover, two widely used swab types were compared (UTM 3 mL and ESwab 1 mL, COPAN). A total of 50 nasopharyngeal swabs (n = 25 UTM 3 mL and n = 25 ESwab 1 mL) from SARS-CoV-2 patients, collected during the pandemic at IRCCS Sacro Cuore Don Calabria Hospital (Veneto Region, North-East Italy), were used for our purpose. After heat inactivation, an aliquot of swab medium was used for the direct quantitation. Then, we compared the direct method with the quantitation performed on the RNA purified from nasopharyngeal swab by automated extraction. We observed that the direct approach achieved generally equal RNA copies compared to the extracted RNA. The results with the direct quantitation were more accurate on ESwab with a sensitivity of 93.33% [95% CI, 68.05 to 99.83] and specificity of 100.00% for both N1 and N2. On the other hand, on UTM we observed a higher rate of discordant results for N1 and N2. The human internal amplification control (RPP30) showed 100% of both sensitivity and specificity independent of swabs and approaches. In conclusion, we described a direct quantitation of SARS-CoV-2 in nasopharyngeal swab. Our approach resulted in an efficient quantitation, without automated RNA extraction and purification. However, special care needs to be taken on the potential bias due to the conservation of samples and to the heating treatment, as we used thawed and heat inactivated material. Further studies on a larger cohort of samples are warranted to evaluate the clinical value of this direct approach.


Assuntos
Técnicas de Laboratório Clínico/métodos , Reação em Cadeia da Polimerase Multiplex/métodos , Betacoronavirus/genética , Betacoronavirus/patogenicidade , Teste para COVID-19 , Técnicas de Laboratório Clínico/normas , Infecções por Coronavirus/diagnóstico , Humanos , Limite de Detecção , Reação em Cadeia da Polimerase Multiplex/normas , Reprodutibilidade dos Testes , Mucosa Respiratória/virologia , SARS-CoV-2
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA