Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Electrocardiol ; 85: 37-38, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38830293

RESUMO

We present the case of a 60-year-old male patient who was admitted to our hospital after experiencing a syncopal episode. First ECGs showed sinus rhythm with polymorphic premature ventricular complexes and later ventricular tachycardia with a left bundle branch block morphology were recorded. Imaging with TEE and MRI revealed a space-occupying lesion in the left ventricle, which was ultimately identified as a rare cardiac metastasis of renal cell carcinoma. Treatment was initiated with monoclonal antibodies resulting in lesion regression. This case highlights the importance of comprehensive diagnostic in patients with history of malignancy.


Assuntos
Carcinoma de Células Renais , Eletrocardiografia , Neoplasias Cardíacas , Ventrículos do Coração , Neoplasias Renais , Taquicardia Ventricular , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias Cardíacas/secundário , Neoplasias Cardíacas/complicações , Neoplasias Cardíacas/diagnóstico por imagem , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/diagnóstico , Neoplasias Renais/patologia , Neoplasias Renais/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Carcinoma de Células Renais/secundário , Carcinoma de Células Renais/complicações , Carcinoma de Células Renais/diagnóstico por imagem , Imageamento por Ressonância Magnética , Diagnóstico Diferencial , Ecocardiografia Transesofagiana
2.
J Cardiovasc Electrophysiol ; 35(7): 1412-1421, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38750671

RESUMO

BACKGROUND: Management of atrial fibrillation (AF) in very severe obese patients is challenging. Cryoballoon ablation (CBA) represents an effective rhythm control strategy. However, data in this patient group were limited. METHODS: Highly symptomatic AF patients with body mass index (BMI) ≥ 40 kg/m2 who had failed antiarrhythmic drug therapy and electrocardioversion and failure to achieve targeted body-weight-reduction underwent CBA. RESULTS: Data of 72 very severe obese AF patients (Group A) and 129 AF patients with normal BMI (Group B, BMI < 25 kg/m2) were consecutively collected. Group A had significantly younger age (60.6 ± 10.4 vs. 69.2 ± 11.2 years), higher BMI (44.3 ± 4.3 vs. 22.5 ± 1.6 kg/m2). Procedural pulmonary vein isolation (PVI) was successful in all patients (2 touch-up ablation in Group A). Compared to Group B, Group A had similar procedural (61.3 ± 22.6 vs. 57.5 ± 19 min), similar fluoroscopy time (10.1 ± 5.5 vs. 9.2 ± 4.8 min) but significantly higher radiation dose (2852 ± 2095 vs. 884 ± 732 µGym2). We observed similar rates of real-time-isolation (78.6% vs. 78.5%), single-shot-isolation (86.5% vs. 88.8%), but significantly longer time-to-sustained-isolation (53.5 ± 33 vs. 43.2 ± 25 s). There was significantly higher rate of puncture-site-complication (6.9% vs. 1.6%) in Group A. One-year clinical success in paroxysmal AF was (Group A: 69.4% vs. Group B: 80.2%; p < .001), in persistent AF was (Group A: 58.1% vs. Group B: 62.8%; p = .889). In Re-Do procedures Group A had a numerically lower PVI durability (75.0% vs. 83.6%, p = .089). CONCLUSION: For very severe obese AF patients, CBA appears feasible, leads to relatively good clinical outcome.


Assuntos
Fibrilação Atrial , Índice de Massa Corporal , Criocirurgia , Estudos de Viabilidade , Obesidade , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Criocirurgia/efeitos adversos , Masculino , Feminino , Resultado do Tratamento , Pessoa de Meia-Idade , Idoso , Fatores de Risco , Fatores de Tempo , Obesidade/diagnóstico , Obesidade/complicações , Obesidade/fisiopatologia , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Frequência Cardíaca , Índice de Gravidade de Doença , Potenciais de Ação , Estudos Retrospectivos , Recidiva
3.
Circ Arrhythm Electrophysiol ; 16(7): 389-398, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37254781

RESUMO

BACKGROUND: The cryoballoon (CB) represents the gold standard single-shot device for pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF). Single-shot pulsed field PVI ablation (nonthermal, cardiac tissue selective) has recently entered the arena. We sought to compare procedural data and long-term outcome of both techniques. METHODS: Consecutive AF patients who underwent pulsed field ablation (PFA) and CB-based PVI were enrolled. CB PVI was performed using the second-generation 28-mm CB; PFA was performed using a 31/35-mm pentaspline catheter. Success was defined as freedom from atrial tachyarrhythmia after a 3-month blanking period. RESULTS: Four hundred patients were included (56.5% men; 60.8% paroxysmal AF; age 70 [interquartile range, 59-77] years), 200 in each group (CB and PFA), and baseline characteristics did not differ. Acute PVI was achieved in 100% of PFA and in 98% (196/200) of CB patients (P=0.123; 4 touch-up ablations). Median procedure time was significantly shorter in PFA (34.5 [29-40] minutes) versus CB (50 [45-60] minutes; P<0.001), fluoroscopy time was similar. Overall procedural complications were 6.5% in CB and 3.0% in PFA (P=0.1), driven by a higher rate of phrenic nerve palsies using CB. The 1-year success rates in paroxysmal AF (CB, 83.1%; PFA, 80.3%; P=0.724) and persistent AF (CB, 71%; PFA, 66.8%; P=0.629) were similar for both techniques. CONCLUSIONS: PFA compared with CB PVI shows a similar procedural efficacy but is associated with shorter procedure time and no phrenic nerve palsies. Importantly, 12-month clinical success rates are favorable but not different between both groups.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Masculino , Humanos , Idoso , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Seguimentos , Resultado do Tratamento , Veias Pulmonares/cirurgia , Paralisia/cirurgia , Ablação por Cateter/métodos , Recidiva
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA