Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Diagnostics (Basel) ; 11(6)2021 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-34073460

RESUMO

Right ventricular (RV) systolic function represents an important independent predictor of adverse outcomes in many cardiovascular (CV) diseases. However, conventional parameters of RV systolic function (tricuspid annular plane excursion (TAPSE), RV myocardial performance index (MPI), and fractional area change (FAC)) are not always able to detect subtle changes in RV function. New evidence indicates a significantly higher predictive value of RV longitudinal strain (LS) over conventional parameters. RVLS showed higher sensitivity and specificity in the detection of RV dysfunction in the absence of RV dilatation, apparent wall motion abnormalities, and reduced global RV systolic function. Additionally, RVLS represents a significant and independent predictor of adverse outcomes in patients with dilated cardiomyopathy (CMP), hypertrophic CMP, arrhythmogenic RV CMP, and amyloidosis, but also in patients with connective tissue diseases and patients with coronary artery disease. Due to its availability, echocardiography remains the main imaging tool for RVLS assessment, but cardiac magnetic resonance (CMR) also represents an important additional imaging tool in RVLG assessment. The findings from the large studies support the routine evaluation of RVLS in the majority of CV patients, but this has still not been adopted in daily clinical practice. This clinical review aims to summarize the significance and predictive value of RVLS in patients with different types of cardiomyopathies, tissue connective diseases, and coronary artery disease.

2.
ESC Heart Fail ; 7(5): 2258-2267, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32578969

RESUMO

AIMS: Atrial fibrillation (AF) and heart failure (HF) are the most common cardiac diseases and often coexist leading to increased mortality and morbidity compared with AF patients without HF. As shown previously, AF ablation using radio frequency (RF) in HF patients leads to a reduction of AF burden, an increase of left ventricular ejection fraction (LVEF) and consequently to reduced hospitalization and mortality. Previous AF ablation studies on HF patients have been liberal about additional targets beyond pulmonary vein isolation (PVI). Thus, the aim of this study was to assess systematically the impact of a straightforward PVI-only strategy on LVEF, NYHA functional class, and cardiovascular hospitalization rate in HF patients. METHODS AND RESULTS: Out of 414 consecutive patients undergoing PVI, only with the cryoballoon 113 patients with reduced LVEF [mean: 38.4 ± 10.8%, reduced ejection fraction (rEF) group] and 301 patients with normal LVEF (>55%) at baseline were identified [normal ejection fraction (nEF) group]. Remarkably, even though freedom from arrhythmia recurrence after 1 year was significantly lower in the rEF group (64.9%) compared with the nEF group (71.2%, P = 0.036), mean LVEF improved from 38.4 ± 10.8% to 52.5 ± 17.2% (P < 0.001) after cryoballoon ablation in the rEF group. Accordingly, HF-related symptoms as well as hospitalization rate declined significantly in the rEF group during follow-up compared with baseline. CONCLUSIONS: The results of the present study suggest that catheter ablation restricted to a straightforward PVI-only strategy using the cryoballoon leads to improved left ventricular ejection fraction as well as improvement of NYHA functional class and increased freedom from cardiovascular rehospitalization.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Insuficiência Cardíaca , Veias Pulmonares , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/cirurgia , Humanos , Veias Pulmonares/cirurgia , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
3.
Catheter Cardiovasc Interv ; 96(3): 687-697, 2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-32104977

RESUMO

OBJECTIVES: To investigate the predictors and clinical impact of left ventricular reverse remodeling (LVRR) after MitraClip (MC) therapy for degenerative (DMR) and functional mitral regurgitation (FMR). BACKGROUND: MC therapy induces LVRR in patients with mitral regurgitation (MR) at high-risk for surgery. However, specific data on predictors of LVRR therapy are limited. METHODS: This study included 164 patients treated by MC implantation with complete clinical and echocardiographic evaluation at baseline, 6 months, and 12 months. LVRR was defined as a decrease of ≥10% of the left ventricular end-diastolic diameter after 12 months and was found in 49% of the patients. RESULTS: LVRR was associated with significantly reduced event rate 2 years after MC procedure. In the total cohort, multivariate regression analysis determined severe recurrent/residual MR after 12 months (p = .010, odds ratio [OR] = 0.26), male gender (p = .050, OR = 0.49) and left ventricular ejection fraction (LVEF) <20% (p = .046, OR = 0.24) as predictors of absence of LVRR. In the subgroup analysis according to etiology of MR, multivariate regression analysis revealed severe recurrent/residual MR after 12 months (p = .04, OR = 0.184) to inversely predict LVRR only in the DMR subgroup. In FMR, residual severe tricuspid regurgitation (TR) inversely predicts LVRR (p = .032, OR = 0.361). CONCLUSIONS: LVRR occurs in half of the patients after MC and is associated with reduced MACCE rates at follow-up. Combined information on residual/recurrent MR, baseline LVEF and gender predict LVRR after MC procedure. While residual/recurrent MR is the independent predictor for the absence of LVRR in DMR, in FMR only severe residual TR independently predict LVRR.


Assuntos
Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Função Ventricular Esquerda , Remodelação Ventricular , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/efeitos adversos , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Recuperação de Função Fisiológica , Recidiva , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
4.
EuroIntervention ; 12(6): 760-7, 2016 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-27542789

RESUMO

AIMS: The aim of the study was to evaluate the procedural and 30-day results for the repositionable Lotus valve in patients undergoing transfemoral aortic valve implantation in a single-centre experience. METHODS AND RESULTS: We prospectively enrolled 110 patients with severe symptomatic aortic stenosis (NCT02162069). All procedures were performed without general anaesthesia by the transfemoral approach. Patients were followed for 30 days. Patients received the 23 mm (n=20), 25 mm (n=43) or 27 mm (n=47) Lotus device. Mean oversizing in relation to annulus or left ventricular outflow tract (LVOT) did not differ among groups. There was no residual moderate or severe aortic regurgitation. The rate of mild aortic regurgitation was low at 9.1%. There was no valve embolisation, no need for a second valve and no conversion to surgery. The need for a new pacemaker implantation due to complete (third degree) or type II (Mobitz) second degree atrioventricular block was 24.1%, excluding patients with previously implanted devices. Within 30 days the rates of all-cause mortality and stroke were low. CONCLUSIONS: In patients with severe aortic stenosis, transfemoral TAVI with the repositionable Lotus valve was associated with a high rate of device success, no moderate or severe residual aortic regurgitation, low rates of major vascular complications and mortality within 30 days.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Estudos Prospectivos , Resultado do Tratamento
5.
PLoS One ; 11(3): e0151247, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27003573

RESUMO

AIMS: The third generation Edwards Sapien 3 (Edwards Lifesciences Inc., Irvine, California) system was optimized to reduce residual aortic regurgitation and vascular complications. METHODS AND RESULTS: 235 patients with severe symptomatic aortic stenosis were prospectively enrolled. Transcatheter aortic valve implantations (TAVI) were performed without general anesthesia by transfemoral approach. Patients were followed for 30 days. Patients received 23mm (N = 77), 26mm (N = 91) or 29mm (N = 67) valve based on pre-procedural 256 multislice computer tomography. Mean oversizing did not differ between the 3 valves. There was no residual moderate or severe aortic regurgitation. Rate of mild aortic regurgitation and regurgitation index did not differ between groups. There was no switch to general anesthesia or conversion to surgery. Rate of major vascular complication was 3.0% with no difference between valve and delivery sheath sizes. Within 30 days rates of all cause mortality (2.6%) and stroke (2.1%) were low. CONCLUSIONS: In patients with severe aortic stenosis transfemoral TAVI with the Edwards Sapien 3 valve without general anesthesia was associated with a high rate of device success, no moderate or severe residual aortic regurgitation, low rates of major vascular complication, mortality and stroke within 30 days with no difference between the 3 valve sizes. TRIAL REGISTRATION: ClinicalTrials.gov NCT02162069.


Assuntos
Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/terapia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/terapia , California , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores/métodos , Estudos Prospectivos , Desenho de Prótese/instrumentação , Desenho de Prótese/métodos , Fatores de Risco , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
6.
PLoS One ; 6(8): e23816, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21886825

RESUMO

BACKGROUND: Ventilation using low tidal volumes with permission of hypercapnia is recommended to protect the lung in acute respiratory distress syndrome. However, the most lung protective tidal volume in association with hypercapnia is unknown. The aim of this study was to assess the effects of different tidal volumes with associated hypercapnia on lung injury and gas exchange in a model for acute respiratory distress syndrome. METHODOLOGY/PRINCIPAL FINDINGS: In this randomized controlled experiment sixty-four surfactant-depleted rabbits were exposed to 6 hours of mechanical ventilation with the following targets: Group 1: tidal volume = 8-10 ml/kg/PaCO(2) = 40 mm Hg; Group 2: tidal volume = 4-5 ml/kg/PaCO(2) = 80 mm Hg; Group 3: tidal volume = 3-4 ml/kg/PaCO(2) = 120 mm Hg; Group 4: tidal volume = 2-3 ml/kg/PaCO(2) = 160 mm Hg. Decreased wet-dry weight ratios of the lungs, lower histological lung injury scores and higher PaO(2) were found in all low tidal volume/hypercapnia groups (group 2, 3, 4) as compared to the group with conventional tidal volume/normocapnia (group 1). The reduction of the tidal volume below 4-5 ml/kg did not enhance lung protection. However, oxygenation and lung protection were maintained at extremely low tidal volumes in association with very severe hypercapnia and no adverse hemodynamic effects were observed with this strategy. CONCLUSION: Ventilation with low tidal volumes and associated hypercapnia was lung protective. A tidal volume below 4-5 ml/kg/PaCO(2) 80 mm Hg with concomitant more severe hypercapnic acidosis did not increase lung protection in this surfactant deficiency model. However, even at extremely low tidal volumes in association with severe hypercapnia lung protection and oxygenation were maintained.


Assuntos
Hipercapnia/complicações , Lesão Pulmonar/etiologia , Respiração Artificial/efeitos adversos , Síndrome do Desconforto Respiratório/etiologia , Volume de Ventilação Pulmonar , Animais , Dióxido de Carbono/sangue , Hemodinâmica , Oxigênio , Coelhos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA