Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Electrocardiol ; 50(3): 358-367, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28109525

RESUMO

BACKGROUND: Transseptal puncture for left heart interventions became a routine procedure guided by fluoroscopy and echocardiography. The use of intracardiac potentials derived from the sheath-transseptal-needle/guidewire-combination may provide helpful information to increase safety of this procedure. METHODS AND RESULTS: We recorded the intracardiac potentials from the sheath-transseptal-needle/guidewire-combination during the transseptal puncture procedure in 31 consecutive patients (mean age 67.2±8.2years; 21 in sinus rhythm, 10 in atrial fibrillation) designated for ablation of atrial fibrillation by the Cryo-balloon ® technique (Medtronic, Minnesota, USA). The EP-Navigator ® 3-D-image integration tool (Philips Healthcare, Hamburg, Germany) was used for visualization of the device position in relation to the cardiac structures. Typical and reproducible potentials could be derived in all patients for the different device localizations at transseptal puncture procedure. Especially the transition from the muscular interatrial septum into the fossa ovalis could be easily depicted by the changes of both morphology and magnitude of the atrial signal (6.1±2.3mV in sinus rhythm [SR]/3.5±0.9mV in atrial fibrillation [AF] at the muscular interatrial septum and 0.5±0.2mV in SR/0.5±0.1mV in AF in the fossa ovalis). CONCLUSIONS: The crucial steps of a transseptal procedure can be verified by typical changes (morphology and amplitude) of the intracardiac signals derived from the sheath-transseptal-needle/guidewire-combination in patients with sinus rhythm as well as in atrial fibrillation.


Assuntos
Mapeamento Potencial de Superfície Corporal/métodos , Cateterismo Cardíaco/métodos , Eletrodos , Septos Cardíacos/cirurgia , Agulhas , Punções/métodos , Cirurgia Assistida por Computador/métodos , Mapeamento Potencial de Superfície Corporal/instrumentação , Cateterismo Cardíaco/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Punções/instrumentação , Cirurgia Assistida por Computador/instrumentação
2.
Int J Cardiol ; 164(2): 170-8, 2013 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-21764470

RESUMO

BACKGROUND: Treatment of heart failure patients with aldosterone antagonists has been shown to reduce the occurrence of sudden cardiac death. Therefore we aimed at determining the consequences of chronic exposure to aldosterone and the aldosterone antagonists eplerenone and spironolactone on the electrophysiological properties of the heart in a rat model. METHODS AND RESULTS: Male Wistar rats were chronically treated (4weeks) with aldosterone (ALD) via an osmotic minipump. Spironolactone (SPI) or eplerenone (EPL) was administered with the rat chow. ALD treated animals developed left ventricular hypertrophy, prolonged QT-intervals, a higher rate of ventricular premature beats and non-sustained ventricular tachycardia despite normal blood pressure values. Spironolactone and eplerenone were both able to inhibit the alterations. Left-ventricular mRNA expressions of Kv4.2 and Kv4.3 (Ito), Kv1.5 (IKur), Kir2.1 and Kir2.3 (IK1) and of Cav1.2 (L-type Ca(2+) channel) were significantly down-regulated in ALD. Correspondingly, the protein expressions of subunits Kv1.5, Kir2.3 and Cav1.2 were significantly decreased. A diminished calcineurin activity and mRNA expression of the Aß subunit of calcineurin were found in ALD, which was insensitive to aldosterone antagonists. CONCLUSIONS: Chronic aldosterone-overload induces blood pressure independent structural and electrical remodeling of the myocardium resulting in an increased risk for malignant ventricular arrhythmias.


Assuntos
Aldosterona/toxicidade , Hipertensão/fisiopatologia , Taquicardia Ventricular/induzido quimicamente , Taquicardia Ventricular/fisiopatologia , Remodelação Ventricular/efeitos dos fármacos , Remodelação Ventricular/fisiologia , Animais , Masculino , Ratos , Ratos Wistar
3.
Europace ; 14(10): 1441-9, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22523379

RESUMO

AIMS: Catheter ablation of the pulmonary veins (PVs) is a promising therapeutic approach for symptomatic atrial fibrillation (AF). The prospective randomized single-centre study 'Mesh Ablator versus Cryoballoon Pulmonary Vein Ablation of Symptomatic Paroxysmal Atrial Fibrillation' (MACPAF; clinicaltrials.gov NCT01061931) compared the efficacy and safety of two balloon-based PV ablation systems. METHODS AND RESULTS: Thirty-two patients underwent PV ablation for symptomatic paroxysmal AF using the Arctic Front® or the HD Mesh Ablator® catheter according to study protocol. The primary endpoint was complete PV isolation (PVI) at the end of the ablation procedure, determined by exit block after achieving entrance block. Long-term follow-up data are not included in this publication. Patients' mean age was 61.7 ± 8.9 years, 43.2% were female, and median CHA2DS2-VASc score was 2.0. In the intention-to-treat analysis, the rate of the primary endpoint was 56.5% in patients randomized to the Arctic Front® and 9.5% in patients randomized to the HD Mesh Ablator® catheter (P = 0.001). In the per-protocol analysis, complete PVI was achieved in 13 (76.5%) of 17 Arctic Front® patients but in none of the 15 HD Mesh Ablator® patients (P < 0.0001). There were one major and two minor complications in each study arm but no clinically evident stroke. Post-procedural AF recurrence was detected within hospital stay in two (11.8%) Arctic Front® patients and in seven (46.7%) HD Mesh Ablator® patients (P = 0.049). CONCLUSION: The MACPAF study revealed a superiority of the Arctic Front® catheter concerning complete PVI. Owing to the insufficient efficacy of the HD Mesh Ablator® catheter, the safety board decided to stop MACPAF prematurely.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Criocirurgia/métodos , Veias Pulmonares/cirurgia , Idoso , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Recidiva , Telas Cirúrgicas , Resultado do Tratamento
4.
Europace ; 13(3): 416-20, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21075757

RESUMO

AIMS: Wound healing is a major determent in the post-surgical course of patients (pts) after pacemaker (PM) and implantable cardioverter defibrillator (ICD) implantation. Insufficient closure may lead to serious complications with pocket infections leading to the device's explantation as the worst case scenario. In addition to the different types of suture and suture clips, a novel topical skin adhesive containing 2-octyl-cyanoacrylate is commercially available. METHODS AND RESULTS: Over a period of 18 months, we prospectively assigned all cases of PM, ICD, and loop recorder implants either to skin adhesive (Group 1) or to absorbable intracutaneous polydioxanon suture (Group 2). Data were analysed with respect to operation time, wound infections, and healing disorders. One hundred and eighty-three pts were randomized into Group 1 [71 PMs, 60 ICD, 15 cardiac resynchronization therapy (CRT), 11 loop recorders, and 26 generator replacements]. One hundred and eighty-five pts were assigned to Group 2 (62 PMs, 70 ICD, 30 CRT, 7 loop recorders, and 16 generator replacements). There were no differences regarding sex, diabetes, renal insufficiency, corticosteroid therapy, oral anticoagulants, and acetylsalicylic asa/clopidogrel (P = n.s.). For the significantly higher amount of CRT devices (P < 0.05) in Group 2, the procedure times are given for surgeries except CRT. It was 49.1 ± 27.7 min for Group 1 and 53.4 ± 31.9 min for Group 2 (P = n.s.). Adverse events as insufficient closure, major and minor bleeding, pocket haematoma, erythema, incrustation, dehiscence, keloid, and explantation due to infection occurred significantly more often in the adhesive group (P = 0.02). The greatest impact on this result had early adverse events as insufficient closure, wound incrustation, and inflammation (9.3 vs. 6.0%; P = 0.02). We did not find any difference in long-term adverse events, infections in particular (2.7 vs. 1.6%; P = 0.47). CONCLUSION: This study shows no benefit using skin adhesive in comparison to absorbable intracutaneous suture regarding surgery times for the implantation of cardiac rhythm devices. The rate of early adverse events after wound closure is higher after skin adhesive but no difference in long-term adverse events occurred.


Assuntos
Arritmias Cardíacas/terapia , Cianoacrilatos/uso terapêutico , Desfibriladores Implantáveis , Marca-Passo Artificial , Polidioxanona/uso terapêutico , Suturas , Cicatrização/fisiologia , Idoso , Idoso de 80 Anos ou mais , Cianoacrilatos/farmacologia , Procedimentos Cirúrgicos Dermatológicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polidioxanona/farmacologia , Estudos Prospectivos , Fatores de Tempo , Adesivos Teciduais/farmacologia , Adesivos Teciduais/uso terapêutico , Resultado do Tratamento , Cicatrização/efeitos dos fármacos
5.
J Exp Med ; 205(10): 2369-79, 2008 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-18794341

RESUMO

The Coxsackievirus-adenovirus receptor (CAR) is known for its role in virus uptake and as a protein of the tight junction. It is predominantly expressed in the developing brain and heart and reinduced upon cardiac remodeling in heart disease. So far, the physiological functions of CAR in the adult heart are largely unknown. We have generated a heart-specific inducible CAR knockout (KO) and found impaired electrical conduction between atrium and ventricle that increased with progressive loss of CAR. The underlying mechanism relates to the cross talk of tight and gap junctions with altered expression and localization of connexins that affect communication between CAR KO cardiomyocytes. Our results indicate that CAR is not only relevant for virus uptake and cardiac remodeling but also has a previously unknown function in the propagation of excitation from the atrium to the ventricle that could explain the association of arrhythmia and Coxsackievirus infection of the heart.


Assuntos
Comunicação Celular/fisiologia , Sistema de Condução Cardíaco/fisiologia , Receptores Virais/metabolismo , Junções Íntimas/metabolismo , Animais , Nó Atrioventricular/fisiologia , Caderinas/genética , Caderinas/metabolismo , Células Cultivadas , Conexina 43/genética , Conexina 43/metabolismo , Proteína de Membrana Semelhante a Receptor de Coxsackie e Adenovirus , Infecções por Coxsackievirus/metabolismo , Infecções por Coxsackievirus/fisiopatologia , Eletrocardiografia , Eletrofisiologia , Junções Comunicantes/metabolismo , Coração/anatomia & histologia , Coração/embriologia , Coração/crescimento & desenvolvimento , Coração/fisiologia , Sistema de Condução Cardíaco/anatomia & histologia , Humanos , Camundongos , Camundongos Knockout , Miócitos Cardíacos/citologia , Miócitos Cardíacos/metabolismo , Fenótipo , Receptores Virais/genética
6.
Hypertension ; 49(3): 481-9, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17224470

RESUMO

We investigated whether or not p38 mitogen-activated protein kinase inhibition ameliorates angiotensin II-induced target organ damage. We used double transgenic rats harboring both human renin and angiotensinogen genes (dTGRs). dTGR, with or without p38 inhibitor (BIRB796; 30 mg/kg per day in the diet), and nontransgenic Sprague-Dawley rats were studied in 2 protocols. In protocol 1 (week 7), systolic blood pressure of untreated dTGRs was 204+/-4 mm Hg, but partially reduced after BIRB796 treatment (166+/-7 mm Hg), whereas Sprague-Dawley rats were normotensive. The cardiac hypertrophy index was unchanged in untreated and BIRB796-treated dTGRs. The beta-myosin heavy chain expression of BIRB796-treated hearts was significantly lower in BIRB796 compared with dTGRs, indicating a delayed switch to the fetal isoform. BIRB796 treatment significantly reduced cardiac fibrosis, connective tissue growth factor, tumor necrosis factor-alpha, interleukin-6, and macrophage infiltration. Albuminuria was not reduced in BIRB796-treated dTGRs. Tubular and glomerular damage with tumor necrosis factor-alpha expression was unaltered, although serum creatinine and cystatin C were normalized. Renal macrophage infiltration, fibrosis, and vessel damage were reduced. In protocol 2 (week 8), we focused on mortality and arrhythmogenic electrical remodeling. Mortality of untreated dTGRs was 100% but was reduced to 10% in the BIRB796 group. Cardiac magnetic field mapping showed prolongation of depolarization and repolarization in untreated dTGRs compared with Sprague-Dawley rats with a partial reduction by BIRB796. Programmed electrical stimulation elicited ventricular tachycardias in 81% of untreated dTGRs but only in 48% of BIRB796-treated dTGRs. In conclusion, BIRB796 improved survival, target organ damage, and arrhythmogenic potential in angiotensin II-induced target organ damage.


Assuntos
Doenças Cardiovasculares/prevenção & controle , Nefropatias/prevenção & controle , Naftalenos/uso terapêutico , Inibidores de Proteínas Quinases/uso terapêutico , Pirazóis/uso terapêutico , Proteínas Quinases p38 Ativadas por Mitógeno/antagonistas & inibidores , Angiotensina II/efeitos adversos , Angiotensinogênio/genética , Animais , Animais Geneticamente Modificados , Doenças Cardiovasculares/etiologia , Modelos Animais de Doenças , Nefropatias/etiologia , Masculino , Ratos , Ratos Sprague-Dawley , Renina/genética
7.
Phys Rev E Stat Nonlin Soft Matter Phys ; 73(4 Pt 1): 041907, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16711836

RESUMO

In this work, we reanalyze the heart rate variability (HRV) data from the 2002 Computers in Cardiology (CiC) Challenge using the concept of large-scale dimension densities and additionally apply this technique to data of healthy persons and of patients with cardiac diseases. The large-scale dimension density (LASDID) is estimated from the time series using a normalized Grassberger-Procaccia algorithm, which leads to a suitable correction of systematic errors produced by boundary effects in the rather large scales of a system. This way, it is possible to analyze rather short, nonstationary, and unfiltered data, such as HRV. Moreover, this method allows us to analyze short parts of the data and to look for differences between day and night. The circadian changes in the dimension density enable us to distinguish almost completely between real data and computer-generated data from the CiC 2002 challenge using only one parameter. In the second part we analyzed the data of 15 patients with atrial fibrillation (AF), 15 patients with congestive heart failure (CHF), 15 elderly healthy subjects (EH), as well as 18 young and healthy persons (YH). With our method we are able to separate completely the AF (rho (mu/ls) = 0.97 +/- 0.02) group from the others and, especially during daytime, the CHF patients show significant differences from the young and elderly healthy volunteers (CHF, 0.65 +/- 0.13; EH, 0.54 +/- 0.05; YH, 0.57 +/- 0.05; p < 0.05 for both comparisons). Moreover, for the CHF patients we find no circadian changes in rho (mu/ls) (day, 0.65 +/- 0.13; night, 0.66 +/- 0.12; n.s.) in contrast to healthy controls (day, 0.54 +/- 0.05; night, 0.61 +/- 0.05; p=0.002). Correlation analysis showed no statistical significant relation between standard HRV and circadian LASDID, demonstrating a possibly independent application of our method for clinical risk stratification.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Diagnóstico por Computador/métodos , Eletrocardiografia/métodos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Frequência Cardíaca , Simulação por Computador , Interpretação Estatística de Dados , Humanos , Modelos Cardiovasculares , Modelos Estatísticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
Phys Rev E Stat Nonlin Soft Matter Phys ; 66(2 Pt 2): 026702, 2002 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12241313

RESUMO

The knowledge of transitions between regular, laminar or chaotic behaviors is essential to understand the underlying mechanisms behind complex systems. While several linear approaches are often insufficient to describe such processes, there are several nonlinear methods that, however, require rather long time observations. To overcome these difficulties, we propose measures of complexity based on vertical structures in recurrence plots and apply them to the logistic map as well as to heart-rate-variability data. For the logistic map these measures enable us not only to detect transitions between chaotic and periodic states, but also to identify laminar states, i.e., chaos-chaos transitions. The traditional recurrence quantification analysis fails to detect the latter transitions. Applying our measures to the heart-rate-variability data, we are able to detect and quantify the laminar phases before a life-threatening cardiac arrhythmia occurs thereby facilitating a prediction of such an event. Our findings could be of importance for the therapy of malignant cardiac arrhythmias.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA