Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
1.
Pacing Clin Electrophysiol ; 45(9): 1024-1031, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35822917

RESUMO

BACKGROUND: Perimitral flutter and atrial fibrillation may occur in patients with prior surgical mitral valve (MV) repair or replacement and can be challenging for percutaneous catheter ablation. This study sought to determine the feasibility, acute success and durability of catheter ablation of atrial fibrillation or atrial tachycardia by way of a mitral isthmus line (MIL) or an anterior line (AL). METHODS: A total of 81 patients (49 males, mean age 62±11 years) with prior MV replacement (n = 30) or reconstruction (n = 51) underwent creation of a MIL (34) and/or an AL (72). RESULTS: Acute bidirectional block of the MIL was successfully achieved in 24/34 cases and of the AL in 64/72 patients. Patients of the control group without prior MV surgery were matched 1:1 with the valve group. In the AL control subgroup, acute bidirectional block was achieved in 65/72 patients. Acute blockage in the MIL control subgroup could be achieved in 31/34 patients. The MIL valve subgroup showed the worst results in terms of durability, whereas a similar trend emerged in the control group and the AL valve subgroup (probability of failure in MIL valve subgroup 2.224 vs. MIL control subgroup 0.605 [Hazard Ratio (HR) = 0.27, 95% confidence interval (CI), 0.11-0.65), P = .004]; probability of failure in AL valve subgroup 0.844 vs. AL control subgroup 1.03 [HR = 1.22 (95% CI, 0.66-2.26), P = .523]). CONCLUSIONS: Percutaneous creation of MIL and AL is feasible and safe in patients with prior MV replacement/repair and associated with moderate acute and long-term success rates to achieve bidirectional block.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Taquicardia Supraventricular , Idoso , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Átrios do Coração , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/cirurgia , Resultado do Tratamento
2.
J Cardiovasc Electrophysiol ; 33(8): 1678-1686, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35615939

RESUMO

INTRODUCTION: Focal Impulse and Rotor Modulation (FIRM) guided catheter ablation aiming at stable rotors has been investigated as a treatment option in patients with atrial fibrillation (AF). The objective of this study was to compare the safety and efficacy of FIRM-guided ablation with second-generation cryoballoon pulmonary vein isolation (CB2-PVI) in paroxysmal AF. METHODS: Consecutive patients (n = 22, mean age 60 ± 11 years, 59.1% of males) who were treated with a stand-alone FIRM-guided ablation were included in this retrospective single-center study. Procedural data and arrhythmia-free survival at 12 months were compared with n = 86 consecutive patients (mean age 62 ± 13 years, 62.4% of males) who received de-novo CB2-PVI. RESULTS: Median procedure duration was significantly longer in the FIRM group than in the CB2-PVI group (152 [IQR 120-176] minutes vs. 122 [110-145] minutes; p = .031). One patient (1.2%) in the CB2-PVI group and five patients (22.7%) in the FIRM group had vascular access complications. Atrial tachyarrhythmias recurred in 15 patients in the FIRM group and 11 in the CB2-PVI group. Kaplan-Meier estimation of single-procedure arrhythmia-free survival at 12 months was 25% (95% confidence interval [CI] 6%-44%) in the FIRM group and 87% (95% CI 78%-96%) in the CB2-PVI group (p < .001). Repeat ablations were performed in 14/20 (70.0%) patients in the FIRM group and in 12/85 (14.1%) in the CB2-PVI group (p < .001). CONCLUSION: De novo ablation of AF using FIRM-guided AF ablation results in shorter arrhythmia-free survival after 12 months compared to CB2-PVI and a need for repeat ablation in the majority of patients to achieve stable sinus rhythm.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Criocirurgia/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Recidiva , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
3.
Cardiol J ; 29(5): 807-814, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-33140384

RESUMO

BACKGROUND: The current study sought to assess the impact of the intraprocedural heart rhythm (sinus rhythm [SR] vs. atrial fibrillation [AF]) on acute procedural characteristics, durability of pulmonary vein isolation (PVI) and long-term clinical outcomes of cryoballoon (CB) ablation. METHODS: A total of 195 patients with symptomatic paroxysmal (n = 136) or persistent AF (n = 59) underwent CB-based PVI. Ablation procedures were either performed in SR (SR group; n = 147) or during AF (AF group; n = 48). Persistent AF was more frequent in the AF group than in the SR group (62% vs. 20%). All other patient baseline characteristics did not differ between the two groups. RESULTS: The nadir temperature during the CB applications was significantly lower in the AF group than in patients in the SR group (-49 [interquartile range, -44; -54]°C vs. -47 [-42; -52]°C, p = 0.002). Median procedure and fluoroscopy times as well as the rate of real-time recordings were not different between the two groups. Repeat ablation for the treatment of atrial arrhythmia recurrence was performed in 60 patients (SR: 44 [30%] patients; AF: 16 [33%] patients), with a trend towards a lower rate of pulmonary vein reconnections in the AF group (p = 0.07). There was no difference in 3-year arrhythmia-free survival (p = 0.8). CONCLUSIONS: Cryoballoon-based PVI during AF results in lower nadir balloon temperatures and a trend towards a higher durability of PVI as compared to procedures performed in SR. The rate of real-time PVI recordings was not affected by the intraprocedural heart rhythm.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
4.
Europace ; 24(6): 921-927, 2022 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-34907431

RESUMO

AIMS: Cryoballoon (CB) based pulmonary vein isolation (PVI) is a widely used technique for treatment of atrial fibrillation (AF); however the ideal energy dosing has not yet been standardized. This was a single-centre randomized clinical trial aiming at assessing the safety, acute efficacy, and clinical outcome of an individualized vs. a fixed CB ablation protocol using the fourth-generation CB (CB4) guided by pulmonary vein (PV) potential recordings and CB temperature. METHODS AND RESULTS: Patients were randomized in a 1:1 fashion to two different dosing protocols: INDI-FREEZE group (individualized protocol): freeze-cycle duration of time to effect plus 90 s or interruption of the freeze-cycle and repositioning CB if a CB temperature of -30°C was not within 40 s. Control group (fixed protocol): freeze-cycle duration of 180 s. No-bonus freeze-cycle was applied in either patient group. The primary endpoint was freedom from atrial tachyarrhythmia at 12 months. Secondary end points included procedural parameters and complications. A total of 100 patients with paroxysmal AF were prospectively enrolled. No difference was seen in the primary endpoint [INDI-FREEZE group: 38/47 (81%) vs. control group: 40/47, (85%), P = 0.583]. The total freezing time was significantly shorter in the INDI-FREEZE group (157 ± 56 s vs. 212 ± 83 s, P < 0.001), while procedure duration (57.9 ± 17.9 min vs. 63.2 ± 20.2 min, P = 0.172) was similar. No differences were seen in the minimum CB and oesophageal temperatures as well as in periprocedural complications. CONCLUSION: Compared to the fixed protocol, the individualized approach provides a similar safety profile and clinical outcome, while reducing the total freezing time.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Congelamento , Humanos , Veias Pulmonares/cirurgia , Recidiva , Fatores de Tempo , Resultado do Tratamento
5.
Clin Res Cardiol ; 111(5): 530-540, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34318341

RESUMO

AIMS: Catheter ablation of ventricular arrhythmias (VA) has proven to be an effective therapeutic option for secondary arrhythmia prophylaxis. We sought to assess the procedural efficacy, safety and in-hospital mortality of a large patient cohort with and without structural heart disease undergoing VA ablation. METHODS: A total of 1417 patients (804 patients with structural heart disease) undergoing 1792 endo- and epicardial procedures were analyzed. Multivariable risk factor analysis for occurrence of major complications and intrahospital mortality was obtained and a score to allow preprocedural risk assessment for patients undergoing VA ablation procedures was established. RESULTS: Major complication occurred in 4.4% of all procedures and significantly more often in patients with structural heart disease than in structurally normal hearts (6.0 vs. 1.8%). The frequency of these periprocedural complications was significantly different between procedures with sole right ventricular and a combination of RV and LV access (0.5 vs. 3.1%). The most common complication was cardiac tamponade in 46 cases (3.0%). Intrahospital death was observed in 32 patients (1.8%). Logistic regression model revealed presence of ischemic heart disease, epicardial ablation, presence of oral anticoagulation or dual antiplatelet therapy as independent risk factors for the occurrence of complications or intrahospital death, while a history of previous heart surgery was an independent predictor with a decreased risk. Based on this analysis a risk score incorporating 5 standard variables was established to predict the occurrence of complications and intrahospital mortality. CONCLUSIONS: Safety of VA catheter ablation mainly relies on patient baseline characteristics and the type of access into the ventricles or epicardial space.


Assuntos
Tamponamento Cardíaco , Ablação por Cateter , Taquicardia Ventricular , Arritmias Cardíacas/etiologia , Tamponamento Cardíaco/etiologia , Ablação por Cateter/métodos , Humanos , Fatores de Risco , Resultado do Tratamento
6.
Circ J ; 85(8): 1296-1304, 2021 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-33854004

RESUMO

BACKGROUND: The arctic front cryoballoon (AF-CB) provides effective and durable pulmonary vein isolation (PVI) associated with encouraging clinical outcome. The POLARx cryoballoon incorporates unique features and design changes that may translate into improved efficacy, safety and further simplified balloon-based procedures. Efficacy and safety of the novel POLARx cryoballoon was compared to the fourth generation AF-CB (AF-CB4).Methods and Results:Twenty-five consecutive patients with paroxysmal or persistent atrial fibrillation were prospectively enrolled, underwent POLARx-based PVI (POLARx group) and were compared to 25 consecutive patients treated with the AF-CB4 (AF-CB4 group). All PVs were successfully isolated utilizing the POLARx and AF-CB4. A significant difference regarding the mean minimal cryoballoon temperatures reached using the AF-CB4 and POLARx (-50±6℃ vs. -57±7℃, P=0.004) was observed. Real-time PVI was visualized in 81% of POLARx patients and 42% of AF-CB4 patients (P<0.001). Utilizing the POLARx, a trend towards shorter median procedure time (POLARx: 45 [39, 53] min vs. AF-CB4: 55 [50, 60] min; P=0.062) was found. No differences were observed between AF-CB4 and POLARx concerning catheter maneuverability, catheter stability and periprocedural complications. CONCLUSIONS: The novel POLARx showed similar safety and efficacy compared to the AF-CB4. A higher rate of real-time PV recordings and significantly lower minimal balloon temperatures were observed using the POLARx.


Assuntos
Criocirurgia , Veias Pulmonares , Fibrilação Atrial/cirurgia , Ablação por Cateter , Humanos , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
7.
J Cardiovasc Electrophysiol ; 32(6): 1553-1560, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33760304

RESUMO

BACKGROUND: The second-generation cryoballoon (CB2) provides effective and durable pulmonary vein isolation (PVI) associated with encouraging clinical outcome. The novel fourth-generation cryoballoon (CB4) incorporates a 40% shorter distal tip. This design change may translate into an increased rate of PVI real-time signal recording, facilitating an individualized ablation strategy using the time to effect (TTE). METHODS AND RESULTS: Three hundred consecutive patients with paroxysmal or persistent atrial fibrillation were prospectively enrolled. The first 150 consecutive patients underwent CB2 based PVI (CB2 group) and the last 150 consecutive patients were treated with the CB4 (CB4 group). A total of 594/594 (100%, CB4) and 589/594 (99.2%, CB2) pulmonary veins (PVs) were successfully isolated utilizing the CB4 and CB2, respectively (p = .283). The real-time PVI visualization rate was 47% (CB4) and 39% (CB2; p = .005) and the mean freeze cycle duration 200 ± 90 s (CB4) and 228 ± 110 s (CB2; p < .001), respectively. The total procedure time did not differ between the groups (CB4: 64 ± 32 min) and (CB2: 62 ± 29 min, p = .370). No differences in periprocedural complications were detected. CONCLUSIONS: A higher rate of real-time electrical PV recordings are seen using the CB4 as compared to CB2, which may facilitate an individualized ablation strategy using the TTE.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Humanos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
8.
Biotechnol Bioeng ; 118(1): 130-141, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32886350

RESUMO

The sufficient provision of oxygen is mandatory for enzymatic oxidations in aqueous solution, however, in process optimization this still is a bottleneck that cannot be overcome with the established methods of macrobubble aeration. Providing higher mass transfer performance through microbubble aerators, inefficient aeration can be overcome or improved. Investigating the mass transport performance in a model protein solution, the microbubble aeration results in higher kL a values related to the applied airstream in comparison with macrobubble aeration. Comparing the aerators at identical kL a of 160 and 60 1/h, the microbubble aeration is resulting in 25 and 44 times enhanced gas utility compared with aeration with macrobubbles. To prove the feasibility of microbubbles in biocatalysis, the productivity of a glucose oxidase catalyzed biotransformation is compared with macrobubble aeration as well as the gas-saving potential. In contrast to the expectation that the same productivities are achieved at identically applied kL a, microbubble aeration increased the gluconic acid productivity by 32% and resulted in 41.6 times higher oxygen utilization. The observed advantages of microbubble aeration are based on the large volume-specific interfacial area combined with a prolonged residence time, which results in a high mass transfer performance, less enzyme deactivation by foam formation, and reduced gas consumption. This makes microbubble aerators favorable for application in biocatalysis.


Assuntos
Reatores Biológicos , Oxigênio/metabolismo , Eliminação de Resíduos Líquidos , Águas Residuárias , Análise da Demanda Biológica de Oxigênio , Biotransformação
9.
Mar Pollut Bull ; 163: 111920, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33340907

RESUMO

The droplet size distribution (DSD) formed by gas-saturated oil jets is one of the most important characteristics of the flow to understand and model the fate of uncontrolled deep-sea oil spills. The shape of the DSD, generally modeled as a theoretical lognormal, Rosin-Rammler or non-fundamental distribution function, defines the size and the mass volume range of the droplets. Yet, the fundamental DSD shape has received much less attention than the volume median size (d50) and range of the DSD during ten years of research following the Deepwater Horizon (DWH) blowout. To better understand the importance of the distribution function of the droplet size we compare the oil rising time, surface oil mass, and sedimented and beached masses for different DSDs derived from the DWH literature in idealized and applied conditions, while keeping d50 constant. We highlight substantial differences, showing that the probability distribution function of the DSD for far-field modeling is, regardless of the d50, consequential for oil spill response.


Assuntos
Poluição por Petróleo , Golfo do México , Probabilidade
10.
Europace ; 22(8): 1240-1251, 2020 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-32500141

RESUMO

AIMS: The aim of this study was to analyse tamponades following electrophysiological procedures regarding frequency and mortality in a high-volume centre and to identify independent predictors for severe tamponades. METHODS AND RESULTS: We performed a retrospective study on 34 982 consecutive patients undergoing diagnostic electrophysiological studies or catheter ablation of cardiac arrhythmias. The combined endpoint was defined as severe tamponade. Criteria for severe tamponade included surgical repair, repeat pericardiocentesis, cardiopulmonary resuscitation, intrahospital death or death during follow-up, and thrombo-embolic events or complications due to therapeutic management. Multivariate analysis was performed to identify independent predictors for severe tamponade. A total of 226 tamponades were identified. Overall frequency of tamponades was 0.6%. Procedures requiring epicardial approach had the highest rate of tamponades (9.4%). Twenty-nine patients with tamponade underwent surgery (12.8% of all tamponades and 21.4% of tamponades during epicardial procedures). Overall tamponade-related mortality was 0.03% (9 deaths). Fifty-six patients (24.8%) experienced severe tamponade. Independent risk factors for severe tamponades were endocardial ablation of ventricular tachycardia, epicardial approach, balloon device ablation, high aspiration volume during pericardiocentesis and structural heart disease. CONCLUSION: The frequency of tamponades is strongly dependent on the type of procedure performed. Overall tamponade-related mortality was low but significantly higher in patients undergoing epicardial procedures. Surgical backup should be considered for patients undergoing complex ventricular tachycardia ablation and left atrial ablation procedures.


Assuntos
Tamponamento Cardíaco , Ablação por Cateter , Eletrofisiologia Cardíaca , Tamponamento Cardíaco/diagnóstico , Tamponamento Cardíaco/cirurgia , Ablação por Cateter/efeitos adversos , Humanos , Pericardiocentese/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento
11.
J Cardiovasc Electrophysiol ; 31(5): 1051-1061, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32107811

RESUMO

INTRODUCTION: The aim of this study was to investigate electrophysiological findings in patients with arrhythmia recurrence undergoing a repeat ablation procedure using ultra-high-density (UHDx) mapping following an index procedure using either contact-force (CF)-guided radiofrequency current (RFC) pulmonary vein isolation (PVI) or second-generation cryoballoon (CB) PVI for treatment of atrial fibrillation (AF). METHODS AND RESULTS: Fifty consecutive patients with recurrence of AF and/or atrial tachycardia (AT) following index CF-RFC PVI (n = 21) or CB PVI (n = 29) were included. A 64-pole mini-basket mapping catheter in combination with an UHDx-mapping system-guided ablation was used. RFC was applied using a catheter tip with three incorporated mini-electrodes. PV reconnection rates were higher after CF-RFC PVI (CF-RFC: 2.5 ± 1.3 PVs vs CB: 1.4 ± 0.9 PVs; P = .0025) and left PVs were more frequently reconnected (CF-RFC: 64% PVs vs CB: 35% PVs; P = .0077). Fractionated signals along the antral index ablation line (FS) were found in 30% of CB-PVI patients (CF-RFC: 9.5% vs CB:30%; P = .098) targeted for ablation. In five cases, FS were a critical part of maintaining consecutive AT. The main AT mechanism found during reablation (n = 45 ATs) was macroreentry (80% [36/45], CF-RFC: 78.9% vs CB: 80.8%; P = 1.0) with a variety of circuits throughout both atria. CONCLUSION: UHDx mapping is sensitive in detecting conduction gaps along the index ablation line. Left PVs are more frequently reconnected after initial CF-RFC PVI. FS are a common finding after CB PVI and can maintain certain forms of ATs. ATs after index PVI are mostly macroreentries with a broad spectrum of entities.


Assuntos
Potenciais de Ação , Fibrilação Atrial/cirurgia , Ablação por Cateter , Criocirurgia , Técnicas Eletrofisiológicas Cardíacas , Frequência Cardíaca , Veias Pulmonares/cirurgia , Taquicardia Supraventricular/cirurgia , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Veias Pulmonares/fisiopatologia , Recidiva , Reoperação , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
12.
Echocardiography ; 37(3): 380-387, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32049400

RESUMO

OBJECTIVES: The aim of this study was to investigate reliability and accuracy of noninvasive measurement method by echocardiography compared to invasive measurement of systolic pulmonary artery pressure (SPAP) in a large cohort of aortic stenosis (AS) patients. BACKGROUND: Pulmonary hypertension (PH) is common in patients with cardiac disease, especially in left heart disease like severe AS. Invasive measurement by right heart catheterization (RHC) is the gold standard to assess pulmonary pressures. Nevertheless, echocardiography is widely used in everyday practice for estimation of pulmonary pressures and diagnosing PH. METHODS: A total of 1400 patients with AS and full invasive hemodynamic assessment by RHC and noninvasive measurements by Doppler echocardiography were included. RESULTS: Mean patient age was 81.5 ± 6.8 years, and 46.3% were males. SPAP was 44.7 ± 15.1 mm Hg by echocardiography and 45.3 ± 15.2 mm Hg by RHC. Pearson's correlation coefficient was r = .820 (P < .0001). Bland-Altman analysis showed a bias of -0.56 mm Hg (95% limits of agreement -18.38 to + 17.26 mm Hg) and 80.6% measurement accuracy. Pulmonary hypertension defined by RHC as a mean PAP ≥25 mm Hg was reliably diagnosed via an echocardiographically measured SPAP of >40 mm Hg (82.2% sensitivity, 80.2% specificity, 83.1% positive predictive value, 79.2% negative predictive value). CONCLUSIONS: In a large cohort of patients with severe aortic stenosis, we could demonstrate a very good correlation of SPAP between Doppler echocardiography and invasive RHC measurement. Pulmonary hypertension could be diagnosed by echocardiography with high sensitivity and specificity.


Assuntos
Estenose da Valva Aórtica , Cateterismo Cardíaco , Artéria Pulmonar , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/diagnóstico por imagem , Ecocardiografia Doppler , Feminino , Humanos , Masculino , Artéria Pulmonar/diagnóstico por imagem , Reprodutibilidade dos Testes
13.
Circ Arrhythm Electrophysiol ; 12(6): e007247, 2019 05 22.
Artigo em Inglês | MEDLINE | ID: mdl-31693319

RESUMO

Background: The FIRE AND ICE trial assessed efficacy and safety of pulmonary vein (PV) isolation using cryoballoon versus radiofrequency current (RFC) ablation in patients with drug refractory, symptomatic, paroxysmal atrial fibrillation (AF). The purpose of the current study was to assess index lesion durability as well as reablation strategy and outcomes in trial patients undergoing a reablation procedure. Methods: Patients with reablation procedures during FIRE AND ICEwere retrospectively consented and enrolled at 13 trial centers. The first reablation for each patient was included in the analysis. Documented arrhythmias before reablation, number and location of reconnected PVs, lesions created during reablations, procedural characteristics, and acute as well as long-term outcomes were assessed. Results: Eighty-nine (36 cryoballoon and 53 RFC) patients were included in this study. Paroxysmal atrial fibrillation was the predominant recurrent arrhythmia (69%) before reablation. Reablations occurred at a median of 173 and 182 days (P=0.54) in the cryoballoon and RFC cohorts, respectively. The number of reconnected PVs was significantly higher in the RFC than the cryoballoon group (2.1±1.4 versus 1.4±1.1; P=0.010), which was driven by significantly more reconnected left superior PVs and markedly more reconnected right superior PVs. The number of (predominantly RFC) lesions applied during reablation was significantly greater in patients originally treated with RFC (3.3±1.3 versus 2.5±1.5; P=0.015) with no difference in overall acute success (P=0.70). After reablation, no differences in procedure-related rehospitalization or antiarrhythmic drug utilization were observed between cohorts. Conclusions: At reablation, patients originally treated with the cryoballoon had significantly fewer reconnected PVs, which may reflect RFC catheter instability in certain left atrial regions, and thus required fewer lesions for reablation success. Repeat ablations were predominantly performed with RFC and resulted in similar acute success, duration of hospitalization, and antiarrhythmic drug prescription between the study cohorts.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Criocirurgia , Veias Pulmonares/cirurgia , Potenciais de Ação , Adolescente , Adulto , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Europa (Continente) , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/fisiopatologia , Ensaios Clínicos Controlados Aleatórios como Assunto , Recidiva , Reoperação , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
14.
Europace ; 21(10): 1494-1501, 2019 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-31327016

RESUMO

AIMS: Arrhythmia recurrence is a common clinical problem in patients with pulmonary vein stenosis (PVS) following catheter ablation of atrial fibrillation. The study sought to analyse the management of arrhythmia recurrence in patients with PVS. METHODS AND RESULTS: Retrospective analysis was performed on 29 patients with high-degree PVS. Follow-up contained clinical visits, Holter-electrocardiogram recordings and invasive pulmonary vein (PV) angiography and electrophysiological studies. Arrhythmia recurrence was observed in 18 patients (62%) after PVS formation. Fifteen of 18 patients (83.3%) with and 1 of 11 patients (9.1%) without arrhythmia recurrence had electrical PV reconnection (P = 0.0003). In 14 of 16 patients repeat pulmonary vein isolation (PVI) was conducted (radiofrequency ablation in 12 and cryoballoon ablation in 2 cases). Repeat PVI was successful in all PVs in nine patients and incomplete in five patients (failed attempt in two patients with stent implantation, no attempt in three patients with stenotic PVs). Freedom from arrhythmia recurrence was estimated at 56.3% [95% confidence interval (CI) 36.4-72.0%] after 24 months. At the end of the follow-up, complete PVI was documented in 19 of 23 patients (82.6%) with stable sinus rhythm and in 2 of 6 patients with arrhythmia recurrence (33.3%) (P = 0.0335). The Kaplan-Meier estimate of recurrence-free survival of restenosis after interventional PVS treatment was similar in patients without and with repeat ablation [75.6% (95% CI 57.0-94.3%) and 67.0% (95% CI 43.2-90.7%) after 500 days, P = 0.77]. CONCLUSIONS: Pulmonary vein reconnection is the major driver of arrhythmia recurrence in PVS patients. Repeat PVI is feasible and does not lead to progression of PVS or restenosis if the procedure is carefully performed.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Sistema de Condução Cardíaco/fisiopatologia , Complicações Pós-Operatórias , Estenose de Veia Pulmonar/etiologia , Stents , Procedimentos Cirúrgicos Vasculares/métodos , Angiografia , Fibrilação Atrial/fisiopatologia , Criocirurgia/efeitos adversos , Eletrocardiografia Ambulatorial , Feminino , Seguimentos , Sistema de Condução Cardíaco/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Estenose de Veia Pulmonar/diagnóstico , Estenose de Veia Pulmonar/cirurgia , Resultado do Tratamento
15.
J Cardiovasc Electrophysiol ; 30(9): 1436-1442, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31190440

RESUMO

AIMS: We sought to assess (1) clinical outcomes of second-generation cryoballoon (CB) ablation for persistent atrial fibrillation (AF), and (2) the association of baseline and procedural covariates with atrial arrhythmia recurrence (AAR) after ablation. METHODS: A total of 135 patients (63 ± 11 years, 96 men [71%]) with persistent AF underwent CB ablation at three experienced electrophysiology centers. Freedom from AAR was estimated with the Kaplan-Meier method. A Cox proportional-hazards model was used to estimate the effects of baseline and procedural covariates on the likelihood of AAR. RESULTS: Freedom from AAR at 6, 12, and 18 months was estimated at 91% (95% confidence interval [CI] 86%-96%), 75% (95% CI, 67%-83%), and 53% (95% CI, 43%-65%), respectively. The presence of an implantable cardiac device (Hazard ratio [HR] 3.09; 95% CI, 1.37-7.00; P = .007), a left atrial (LA) diameter > 50 mm (HR 1.69; 95% CI, 1.02-2.79; P = .043), and absence of antiarrhythmic drug (AAD) therapy before the ablation procedure (HR 3.12; 95% CI, 1.72-5.64; P < .001) were associated with AAR. A trend toward an increased risk of AAR was revealed for women (HR 1.73; 95% CI, 0.96-3.11; P = .069). CONCLUSIONS: CB ablation for persistent AF resulted in freedom from AAR about that reported for RF ablation. The presence of an implantable cardiac device, LA size, and absence of AAD therapy at baseline were associated with the risk of AAR.


Assuntos
Fibrilação Atrial/cirurgia , Criocirurgia , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Criocirurgia/efeitos adversos , Criocirurgia/instrumentação , Feminino , Alemanha , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Intervalo Livre de Progressão , Veias Pulmonares/fisiopatologia , Recidiva , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo
16.
Int J Cardiol ; 285: 21-26, 2019 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-30871803

RESUMO

BACKGROUND: Many candidates with ischaemic functional mitral regurgitation (FMR) have previously undergone coronary artery bypass grafting (CABG), in which transcatheter mitral valve repair can be reasonable for ameliorating the deteriorated hemodynamic and heart failure symptoms. We sought to elucidate the outcomes of MitraClip (MC) implantation in patients with symptomatic ischaemic FMR after CABG. METHODS: We investigated clinical characteristics, outcomes and predictive impact of previous CABG on mortality in ischaemic FMR patients who underwent MC implantation from two high-volume centres in Germany. RESULTS: We enrolled 159 patients who previously underwent CABG. Compared with a reference group that did not previously undergo CABG (n = 182), the cohort consisted of more elderly patients (75.0, standard deviation [SD] 7.7 versus 72.9, SD 9.6 years, p = 0.028), more men (84% vs. 69%, p < 0.001), and reduced tricuspid annular plane systolic excursion (14.0, SD 4.0, vs. 16.6, SD 4.6 mm, p < 0.0001). The CABG group showed similar outcomes regarding procedural success (91% vs. 94%, p = 0.24) and 30-day mortality (5.0% vs. 6.0%, p = 0.68), but worse survival after MC implantation (log-rank p = 0.019, hazard ratio 1.56 [95% confidence interval (CI) 1.08-2.26]). After propensity score matching (n = 224), the hazard ratio was 1.18 [95%CI 0.76-1.84] without statistical significance (p = 0.46). CONCLUSIONS: Transcatheter mitral valve repair using the MC is a viable treatment option for patients with symptomatic ischaemic FMR after CABG. Although the baseline characteristics seemed to point to sick patients, CABG itself had only a modest impact on survival.


Assuntos
Ponte de Artéria Coronária/métodos , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral/cirurgia , Isquemia Miocárdica/complicações , Idoso , Feminino , Seguimentos , Alemanha/epidemiologia , Humanos , Masculino , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/mortalidade , Isquemia Miocárdica/mortalidade , Isquemia Miocárdica/cirurgia , Período Pós-Operatório , Prognóstico , Desenho de Prótese , Estudos Retrospectivos , Taxa de Sobrevida/tendências
19.
Environ Sci Technol ; 52(11): 6326-6333, 2018 06 05.
Artigo em Inglês | MEDLINE | ID: mdl-29761700

RESUMO

To date, experimental investigations to determine the droplet size distribution (DSD) of subsea oil spills were mostly conducted at surface conditions, i.e. at atmospheric pressure, and with dead, i.e. purely liquid, oils. To investigate the influence of high hydrostatic pressure and of gases dissolved in the oil on the DSD, experiments with a downscaled blowout are conducted in a high-pressure autoclave at 150 bar hydrostatic pressure. Jets of "live", i.e. methane-saturated, crude oil and n-decane are compared to jets of "dead" hydrocarbon liquids in artificial seawater. Experiments show that methane dissolved in the liquid oil increases the volume median droplet diameter significantly by up to 97%. These results are not in good accordance with state-of-the-art drop formation models, which are based on oil-only experiments at atmospheric pressure, and therefore show the need for a modification of such models which incorporates effects of hydrostatic pressure and dissolved gases for the modeling of deep-sea oil spills and blowouts.


Assuntos
Poluição por Petróleo , Petróleo , Gases , Hidrocarbonetos , Água do Mar
20.
Circ Arrhythm Electrophysiol ; 11(5): e006204, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29700058

RESUMO

BACKGROUND: Data on predictors of long-term clinical outcomes after catheter ablation of atrial fibrillation (AF) are limited. We sought to assess the association of baseline covariates with clinical outcomes in the 750 patients with drug-refractory paroxysmal AF enrolled in FIRE AND ICE. METHODS: In a 2-part analysis, univariate and multivariable Cox regression models were first used to identify baseline patient characteristics predictive of catheter ablation efficacy determined by the clinical end points of (1) atrial arrhythmia recurrence (primary efficacy failure), (2) cardiovascular rehospitalization, and (3) repeat ablation. Propensity score stratification methods were then used to account for differences in baseline characteristics between sexes. RESULTS: Female sex (hazard ratio [HR], 1.37; 95% confidence interval [CI], 1.08-1.73; P=0.010) and prior direct current cardioversion (HR, 1.40; 95% CI, 1.07-1.82; P=0.013) were independently associated with atrial arrhythmia recurrence. Female sex (HR, 1.36; 95% CI, 1.02-1.80; P=0.035) and hypertension (HR, 1.48; 95% CI, 1.09-2.00; P=0.013) independently predicted cardiovascular rehospitalization. A longer history of AF (HR, 1.03; 95% CI, 1.00-1.06; P=0.039) increased the rate of repeat ablation. Women continued to have higher rates of primary efficacy failure and cardiovascular rehospitalization after propensity score adjustment, with adjusted HRs of 1.51 (95% CI, 1.16-2.18; P<0.05) and 1.40 (95% CI, 1.15-2.17; P<0.05), respectively. CONCLUSIONS: After catheter ablation of paroxysmal AF, female sex was associated with an almost 40% increase in the risks of primary efficacy failure and cardiovascular rehospitalization. Primary efficacy failure was also adversely impacted by a history of direct current cardioversion, whereas hypertension had a negative impact on cardiovascular rehospitalization. History of AF was the only predictor of repeat ablation. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT01490814.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Frequência Cardíaca , Potenciais de Ação , Idoso , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Resistência a Medicamentos , Europa (Continente) , Feminino , Disparidades nos Níveis de Saúde , Frequência Cardíaca/efeitos dos fármacos , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Reoperação , Fatores de Risco , Fatores Sexuais , Fatores de Tempo , Falha de Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA