Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Adv Sci (Weinh) ; : e2400673, 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38775058

RESUMO

Anastomotic leakage (AL) is the leaking of non-sterile gastrointestinal contents into a patient's abdominal cavity. AL is one of the most dreaded complications following gastrointestinal surgery, with mortality rates reaching up to 27%. The current diagnostic methods for anastomotic leaks are limited in sensitivity and specificity. Since the timing of detection directly impacts patient outcomes, developing new, fast, and simple methods for early leak detection is crucial. Here, a naked eye-readable, electronic-free macromolecular network drain fluid sensor is introduced for continuous monitoring and early detection of AL at the patient's bedside. The sensor array comprises three different macromolecular network sensing elements, each tailored for selectivity toward the three major digestive enzymes found in the drainage fluid during a developing AL. Upon digestion of the macromolecular network structure by the respective digestive enzymes, the sensor produces an optical shift discernible to the naked eye. The diagnostic efficacy and clinical applicability of these sensors are demonstrated using clinical samples from 32 patients, yielding a Receiver Operating Characteristic Area Under the Curve (ROC AUC) of 1.0. This work has the potential to significantly contribute to improved patient outcomes through continuous monitoring and early, low-cost, and reliable AL detection.

2.
Small Methods ; 7(11): e2300693, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37592160

RESUMO

While often life-saving, surgical resectioning of diseased tissues puts patients at risk for post-operative complications. Sutures and staples are well-accepted and routinely used to reconnect tissues, however, their mechanical mismatch with biological soft tissue and invasiveness contribute to wound healing complications, infections, and post-operative fluid leakage. In principle, laser tissue soldering offers an attractive, minimally-invasive alternative for seamless soft tissue fusion. However, despite encouraging experimental observations, including accelerated healing and lowered infection risk, critical issues related to temperature monitoring and control during soldering and associated complications have prevented their clinical exploitation to date. Here, intelligent laser tissue soldering (iSoldering) with integrated nanothermometry is introduced as a promising yet unexplored approach to overcome the critical shortcomings of laser tissue soldering. It demonstrates that adding thermoplasmonic and nanothermometry nanoparticles to proteinaceous solders enables heat confinement and non-invasive temperature monitoring and control, offering a route to high-performance, leak-tight tissue sealing even at deep tissue sites. The resulting tissue seals exhibit excellent mechanical properties and resistance to chemically-aggressive digestive fluids, including gastrointestinal juice. The iSolder can be readily cut and shaped by surgeons to optimally fit the tissue defect and can even be applied using infrared light from a medically approved light source, hence fulfilling key prerequisites for application in the operating theatre. Overall, iSoldering enables reproducible and well-controlled high-performance tissue sealing, offering new prospects for its clinical exploitation in diverse fields ranging from cardiovascular to visceral and plastic surgery.


Assuntos
Terapia a Laser , Procedimentos de Cirurgia Plástica , Humanos , Terapia a Laser/métodos , Cicatrização , Lasers , Temperatura Alta
3.
Adv Sci (Weinh) ; 10(23): e2301207, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37276437

RESUMO

Postoperative anastomotic leaks are the most feared complications after gastric surgery. For diagnostics clinicians mostly rely on clinical symptoms such as fever and tachycardia, often developing as a result of an already fully developed, i.e., symptomatic, surgical leak. A gastric fluid responsive, dual modality, electronic-free, leak sensor system integrable into surgical adhesive suture support materials is introduced. Leak sensors contain high atomic number carbonates embedded in a polyacrylamide matrix, that upon exposure to gastric fluid convert into gaseous carbon dioxide (CO2 ). CO2 bubbles remain entrapped in the hydrogel matrix, leading to a distinctly increased echogenic contrast detectable by a low-cost and portable ultrasound transducer, while the dissolution of the carbonate species and the resulting diffusion of the cation produces a markedly reduced contrast in computed tomography imaging. The sensing elements can be patterned into a variety of characteristic shapes and can be combined with nonreactive tantalum oxide reference elements, allowing the design of shape-morphing sensing elements visible to the naked eye as well as artificial intelligence-assisted automated detection. In summary, shape-morphing dual modality sensors for the early and robust detection of postoperative complications at deep tissue sites, opening new routes for postoperative patient surveillance using existing hospital infrastructure is reported.


Assuntos
Inteligência Artificial , Dióxido de Carbono , Humanos , Complicações Pós-Operatórias , Fístula Anastomótica/diagnóstico , Tomografia Computadorizada por Raios X
4.
Nat Commun ; 13(1): 7311, 2022 11 27.
Artigo em Inglês | MEDLINE | ID: mdl-36437258

RESUMO

Millions of patients every year undergo gastrointestinal surgery. While often lifesaving, sutured and stapled reconnections leak in around 10% of cases. Currently, surgeons rely on the monitoring of surrogate markers and clinical symptoms, which often lack sensitivity and specificity, hence only offering late-stage detection of fully developed leaks. Here, we present a holistic solution in the form of a modular, intelligent suture support sealant patch capable of containing and detecting leaks early. The pH and/or enzyme-responsive triggerable sensing elements can be read out by point-of-need ultrasound imaging. We demonstrate reliable detection of the breaching of sutures, in as little as 3 hours in intestinal leak scenarios and 15 minutes in gastric leak conditions. This technology paves the way for next-generation suture support materials that seal and offer disambiguation in cases of anastomotic leaks based on point-of-need monitoring, without reliance on complex electronics or bulky (bio)electronic implantables.


Assuntos
Fístula Anastomótica , Hidrogéis , Humanos , Fístula Anastomótica/diagnóstico por imagem , Diagnóstico Precoce , Sensibilidade e Especificidade
5.
Nanomedicine (Lond) ; 11(7): 783-96, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26979124

RESUMO

BACKGROUND: While carbon-encapsulated iron carbide nanoparticles exhibit strong magnetic properties appealing for biomedical applications, potential side effects of such materials remain comparatively poorly understood. Here, we assess the effects of iron-based nanoparticles in an in vivo long-term study in mice with observation windows between 1 week and 1 year. MATERIALS & METHODS: Functionalized (PEG or IgG) carbon-encapsulated platinum-spiked iron carbide nanoparticles were injected intravenously in mice (single or repeated dose administration). RESULTS: One week after administration, magnetic nanoparticles were predominantly localized in organs of the reticuloendothelial system, particularly the lung and liver. After 1 year, particles were still present in these organs, however, without any evident tissue alterations, such as inflammation, fibrosis, necrosis or carcinogenesis. Importantly, reticuloendothelial system organs presented with normal function. CONCLUSION: This long-term exposure study shows high in vivo compatibility of intravenously applied carbon-encapsulated iron nanoparticles suggesting continuing investigations on such materials for biomedical applications.


Assuntos
Compostos Inorgânicos de Carbono/efeitos adversos , Carbono/efeitos adversos , Materiais Revestidos Biocompatíveis/efeitos adversos , Portadores de Fármacos/efeitos adversos , Compostos de Ferro/efeitos adversos , Nanopartículas/efeitos adversos , Animais , Carbono/administração & dosagem , Carbono/química , Carbono/farmacocinética , Compostos Inorgânicos de Carbono/administração & dosagem , Compostos Inorgânicos de Carbono/química , Compostos Inorgânicos de Carbono/farmacocinética , Materiais Revestidos Biocompatíveis/administração & dosagem , Materiais Revestidos Biocompatíveis/química , Portadores de Fármacos/administração & dosagem , Portadores de Fármacos/química , Portadores de Fármacos/farmacocinética , Feminino , Compostos de Ferro/administração & dosagem , Compostos de Ferro/química , Compostos de Ferro/farmacocinética , Fígado/efeitos dos fármacos , Fígado/metabolismo , Fígado/ultraestrutura , Pulmão/efeitos dos fármacos , Pulmão/metabolismo , Pulmão/ultraestrutura , Imãs/efeitos adversos , Imãs/química , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Nanopartículas/administração & dosagem , Nanopartículas/análise , Nanopartículas/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA