Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 135
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38709456

RESUMO

Intraoperative antithrombotic drug removal by haemoadsorption is a novel strategy to reduce perioperative bleeding in patients on antithrombotic drugs undergoing cardiac surgery. The international STAR registry reports real-world clinical outcomes associated with this application. All patients underwent cardiac surgery before completing the recommended washout period. The haemoadsorption device was incorporated into the cardiopulmonary bypass (CPB) circuit. Patients on P2Y12 inhibitors comprised group 1, and patients on direct-acting oral anticoagulants (DOAC) group 2. Outcome measurements included bleeding events according to standardised definitions and 24-hour chest-tube-drainage (CTD). 165 patients were included from 8 institutions in Austria, Germany, Sweden, and the UK. Group 1 included 114 patients (62.9 ± 11.6years, 81% male) operated at a mean time of 33.2 h from the last P2Y12 inhibitor dose with a mean CPB duration of 117.1 ± 62.0 min. Group 2 included 51 patients (68.4 ± 9.4years, 53% male), operated at a mean time of 44.6 h after the last DOAC dose, with a CPB duration of 128.6 ± 48.4 min. In Group 1, 15 patients experienced a BARC-4 bleeding event (13%), including 3 reoperations (2.6%). The mean 24-hour CTD was 651 ± 407mL. In Group 2, 8 patients experienced a BARC-4 bleeding event (16%) including 4 reoperations (7.8%). The mean CTD was 675 ± 363mL. This initial report of the ongoing STAR registry shows that the intraoperative use of a haemoadsorption device is simple and safe, and may potentially mitigate the expected high bleeding risk of patients on antithrombotic drugs undergoing cardiac surgery before completion of the recommended washout period.Clinical registration number: ClinicalTrials.gov identifier: NCT05077124.

2.
Front Cardiovasc Med ; 11: 1344292, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38545343

RESUMO

Intraluminal thrombus formation (ILT) is a recently discovered and highly clinically relevant complication after frozen elephant trunk implantation in cardiovascular surgery. In this phenomenon, a thrombus forms within the lumen of the stent graft component of the frozen elephant trunk prosthesis and puts the patient at risk for downstream embolization with visceral or lower limb ischemia. Incidence of ILT reported in the currently available studies ranges from 6% to 17% of patients after frozen elephant trunk implantation. Adverse thromboembolic events include acute occlusion of the celiac and superior mesenteric arteries, both renal arteries as well as acute lower limb ischemia due to iliac or femoral artery embolization that not infrequently require interventional or open embolectomy. Therefore, the presence of ILT is associated with increased short-term mortality and morbidity. Currently proposed strategies to avoid ILT formation include a more aggressive anticoagulation management, minimization of postoperative coagulation factor application, and even technical optimizations of the stent graft portion itself. If ILT is manifested, the therapeutic strategies tested to date are long-term escalation of anticoagulation and early endovascular extension of the FET stent graft with overstenting of the intraluminal thrombus. The long-term efficiency of these prophylactic and therapeutic measures has yet to be proven. Nonetheless, all surgeons performing the frozen elephant trunk procedure must be aware of the risk of ILT formation to facilitate a timely diagnosis and therapy.

3.
Eur Heart J ; 45(8): 613-625, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38036414

RESUMO

BACKGROUND AND AIMS: HeartMate 3 (HM3) is a fully magnetically levitated continuous flow left ventricular assist device, which received CE marking in 2015. The ELEVATE Registry was initiated to collect real-world outcomes in patients treated with HM3 post-CE Mark approval. METHODS: A total of 540 subjects implanted at 26 centres between March 2015 and February 2017 were included in this registry. Of these, 463 received the device as a primary implant (primary implant cohort, PIC), 19 as a pump exchange (pump exchange cohort), and in 58 patients, only anonymized survival data were collected (anonymized cohort, AC). Patients in the PIC contributed to the baseline demographics, survival, adverse events, quality of life (QoL) (EuroQoL-5 Dimensions-5 Levels visual analogue scale), and functional capacity (6 min walk distance) assessments, while patients in the AC contributed only to survival. RESULTS: Primary implant cohort patients had a mean age of 56 years and were predominantly male (89%) with 48% ischaemic aetiology. The majority of subjects was designated bridge to transplant (66%) and had INTERMACS Profiles 1-3 (70%). At baseline, the subjects had poor functional capacity (104 ± 140 m) and impaired QoL (35 ± 19 points). The overall survival rate of the PIC was 63.3% and survival free of stroke was 58.1% at 5 years. Significant improvements in functional capacity and QoL were observed and maintained for 5 years (301 ± 131 m and 64 ± 20 points, respectively). CONCLUSIONS: Real-world data from the ELEVATE registry demonstrate an overall survival rate for primary implants of 63.3%. In the PIC, reductions in adverse events for patients in the extended follow-up and improved QoL and functional capacity were observed at 5 years in this patient population with advanced heart failure.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Coração Auxiliar/efeitos adversos , Qualidade de Vida , Resultado do Tratamento , Estudos Prospectivos , Sistema de Registros
4.
Artif Organs ; 48(1): 16-27, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37822301

RESUMO

BACKGROUND: The management of concomitant valvular lesions in patients undergoing left ventricular assist device (LVAD) implantation remains a topic of debate. This systematic review and meta-analysis aimed to evaluate the existing evidence on postoperative outcomes following LVAD implantation, with and without concomitant MV surgery. METHODS: A systematic database search was conducted as per PRISMA guidelines, of original articles comparing LVAD alone to LVAD plus concomitant MV surgery up to February 2023. The primary outcomes assessed were overall mortality and early mortality, while secondary outcomes included stroke, need for right ventricular assist device (RVAD) implantation, postoperative mitral valve regurgitation, major bleeding, and renal dysfunction. RESULTS: The meta-analysis included 10 studies comprising 32 184 patients. It revealed that concomitant MV surgery during LVAD implantation did not significantly affect overall mortality (OR:0.83; 95% CI: 0.53 to 1.29; p = 0.40), early mortality (OR:1.17; 95% CI: 0.63 to 2.17; p = 0.63), stroke, need for RVAD implantation, postoperative mitral valve regurgitation, major bleeding, or renal dysfunction. These findings suggest that concomitant MV surgery appears not to confer additional benefits in terms of these clinical outcomes. CONCLUSION: Based on the available evidence, concomitant MV surgery during LVAD implantation does not appear to have a significant impact on postoperative outcomes. However, decision-making regarding MV surgery should be individualized, considering patient-specific factors and characteristics. Further research with prospective studies focusing on specific patient populations and newer LVAD devices is warranted to provide more robust evidence and guide clinical practice in the management of valvular lesions in LVAD recipients.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Nefropatias , Insuficiência da Valva Mitral , Acidente Vascular Cerebral , Humanos , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Coração Auxiliar/efeitos adversos , Estudos Prospectivos , Resultado do Tratamento , Hemorragia/complicações , Nefropatias/complicações , Estudos Retrospectivos
5.
Sci Rep ; 13(1): 18552, 2023 10 29.
Artigo em Inglês | MEDLINE | ID: mdl-37899422

RESUMO

In patients with left ventricular assist device (LVAD), infections and thrombotic events represent severe complications. We investigated device-specific local and systemic inflammation and its impact on cerebrovascular events (CVE) and mortality. In 118 LVAD patients referred for 18F-FDG-PET/CT, metabolic activity of LVAD components, thoracic aortic wall, lymphoid and hematopoietic organs, was quantified and correlated with clinical characteristics, laboratory findings, and outcome. Driveline infection was detected in 92/118 (78%) patients by 18F-FDG-PET/CT. Activity at the driveline entry site was associated with increased signals in aortic wall (r = 0.32, p < 0.001), spleen (r = 0.20, p = 0.03) and bone marrow (r = 0.20, p = 0.03), indicating systemic interactions. Multivariable analysis revealed independent associations of aortic wall activity with activity of spleen (ß = 0.43, 95% CI 0.18-0.68, p < 0.001) and driveline entry site (ß = 0.04, 95% CI 0.01-0.06, p = 0.001). Twenty-two (19%) patients suffered CVE after PET/CT. In a binary logistic regression analysis metabolic activity at the driveline entry site missed the level of significance as an influencing factor for CVE after adjusting for anticoagulation (OR = 1.16, 95% CI 1-1.33, p = 0.05). Metabolic activity of the subcutaneous driveline (OR = 1.13, 95% CI 1.02-1.24, p = 0.016) emerged as independent risk factor for mortality. Molecular imaging revealed systemic inflammatory interplay between thoracic aorta, hematopoietic organs, and infected device components in LVAD patients, the latter predicting CVE and mortality.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Infecções Relacionadas à Prótese , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Fluordesoxiglucose F18 , Coração Auxiliar/efeitos adversos , Infecções Relacionadas à Prótese/etiologia , Inflamação/etiologia , Insuficiência Cardíaca/complicações , Estudos Retrospectivos
6.
Cardiovasc Res ; 119(10): 1969-1980, 2023 08 19.
Artigo em Inglês | MEDLINE | ID: mdl-37315201

RESUMO

AIMS: Heart failure (HF) after myocardial infarction (MI) is a major cause of morbidity and mortality. We sought to investigate the functional importance of cardiac iron status after MI and the potential of pre-emptive iron supplementation in preventing cardiac iron deficiency (ID) and attenuating left ventricular (LV) remodelling. METHODS AND RESULTS: MI was induced in C57BL/6J male mice by left anterior descending coronary artery ligation. Cardiac iron status in the non-infarcted LV myocardium was dynamically regulated after MI: non-haem iron and ferritin increased at 4 weeks but decreased at 24 weeks after MI. Cardiac ID at 24 weeks was associated with reduced expression of iron-dependent electron transport chain (ETC) Complex I compared with sham-operated mice. Hepcidin expression in the non-infarcted LV myocardium was elevated at 4 weeks and suppressed at 24 weeks. Hepcidin suppression at 24 weeks was accompanied by more abundant expression of membrane-localized ferroportin, the iron exporter, in the non-infarcted LV myocardium. Notably, similarly dysregulated iron homeostasis was observed in LV myocardium from failing human hearts, which displayed lower iron content, reduced hepcidin expression, and increased membrane-bound ferroportin. Injecting ferric carboxymaltose (15 µg/g body weight) intravenously at 12, 16, and 20 weeks after MI preserved cardiac iron content and attenuated LV remodelling and dysfunction at 24 weeks compared with saline-injected mice. CONCLUSION: We demonstrate, for the first time, that dynamic changes in cardiac iron status after MI are associated with local hepcidin suppression, leading to cardiac ID long term after MI. Pre-emptive iron supplementation maintained cardiac iron content and attenuated adverse remodelling after MI. Our results identify the spontaneous development of cardiac ID as a novel disease mechanism and therapeutic target in post-infarction LV remodelling and HF.


Assuntos
Insuficiência Cardíaca , Deficiências de Ferro , Infarto do Miocárdio , Masculino , Camundongos , Humanos , Animais , Hepcidinas/metabolismo , Hepcidinas/uso terapêutico , Ferro/metabolismo , Ferro/uso terapêutico , Camundongos Endogâmicos C57BL , Miocárdio/metabolismo , Insuficiência Cardíaca/metabolismo , Suplementos Nutricionais , Remodelação Ventricular
7.
Front Cardiovasc Med ; 10: 1143886, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37187792

RESUMO

We report here the first clinical use of the left atrial appendage (LAA) for epicardial micrograft transplantation during left ventricular assist device (LVAD) implantation. Previously, a sample from the right atrial appendage (RAA) has been available for processing and administering micrograft therapy in cardiac surgery. Both LAA and RAA are rich sources of various types of myocardial cells and are capable of providing both paracrine and cellular support to the failing myocardium. The surgical approach of LAA micrografting facilitates epicardial micrograft therapy dose escalation and treatment of larger myocardial areas than done previously. Moreover, as collection of treated vs. untreated tissues from the recipient heart is possible following LVAD implantation at the time of heart transplantation, the evaluation of the therapy's mechanism of action can be further deciphered at cellular and molecular levels. This LAA modification of the epicardial micrografting technique has the overall potential to facilitate the adoption of cardiac cell therapy during heart surgery.

8.
J Cardiovasc Surg (Torino) ; 64(1): 121-129, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36763071

RESUMO

BACKGROUND: Total artificial heart (TAH) implantation is a rarely performed procedure. Contrarily, left ventricular assist device (VAD) implantation is rather common in many centers. As transplantation is quantitatively limited cardiac replacement with artificial hearts is a viable alternative in the treatment of severe biventricular heart failure. An alternative to TAH is the implantation of two VADs in a TAH configuration. We hereby present the first multi-center study on 3-months outcomes of patients treated by cardiectomy and placement of two HeartMate 3s in a TAH configuration. METHODS: We retrospectively investigated a cohort of 15 patients that underwent HM3-TAH-implantation at three international institutions. Follow-up was 3 months after implantation. Baseline, intra- and postoperative parameters as well as survival data and adverse events were collected. RESULTS: A total of 1089 days on HM3-TAH were observed. Thirty-day survival after HM3-TAH implantation was 53% (8/15) and three month survival was 40% (6/15). The longest duration on device was 274 days. Causes of death were multi-organ failure, sepsis, and neurological adverse events. No technical complications were documented. Two patients remained on the device. Four patients (26%) were successfully bridged to transplantation. CONCLUSIONS: The implantation of two HeartMate 3s in a TAH configuration is a last resort and off-label concept in cases of extreme biventricular heart failure. In a diligently selected patient cohort, HM3-TAH implantation is a feasible method to increase the chance of survival in a severely ill patient cohort and successfully bridge patients to heart transplantation that would otherwise have died.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Artificial , Coração Auxiliar , Humanos , Coração Auxiliar/efeitos adversos , Estudos Retrospectivos , Coração Artificial/efeitos adversos , Insuficiência Cardíaca/cirurgia
9.
Artigo em Inglês | MEDLINE | ID: mdl-36562497

RESUMO

BACKGROUND: The HeartMate 3 (HM 3; Abbott) left ventricular assist device (LVAD) has improved hemocompatibility-related adverse outcomes. In sporadic cases, external compression of the outflow graft causing obstruction (eOGO) can result from substance accumulation between the outflow graft and its bend relief. We sought to evaluate the prevalence, course, and clinical implications of eOGO in an international study. METHODS: A multicenter retrospective analysis of HM 3 LVADs implanted between November 2014 and April 2021 (n = 2108) was conducted across 17 cardiac centers in 8 countries. We defined eOGO as obstruction >25% in the cross-sectional area in imaging (percutaneous angiography, computed tomography, or intravascular ultrasound). The prevalence and annual incidence were calculated. Serious adverse events and outcomes (death, transplantation, or device exchange) were analyzed for eOGO cases. RESULTS: Of 2108 patients, 62 were diagnosed with eOGO at a median LVAD support duration of 953 (interquartile range, 600-1267) days. The prevalence of eOGO was 3.0% and the incidence at 1, 2, 3, 4, and 5 years of support was 0.6%, 2.8%, 4.0%, 5.2%, and 9.1%, respectively. Of 62 patients, 9 were observed, 27 underwent surgical revision, 15 underwent percutaneous stent implantation, 8 received a heart transplant, and 2 died before intervention. One patient underwent surgical revision and later stent implantation. The mortality with therapeutic intervention was 9/53 (17.0%). CONCLUSIONS: Although uncommon, HM 3 LVAD-supported patients might develop eOGO with an increasing incidence after 1 year of support. Although engineering efforts to reduce this complication are under way, clinicians must maintain a focus on early detection and remain vigilant.

11.
Thorac Cardiovasc Surg ; 70(6): 458-466, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35817063

RESUMO

OBJECTIVES: Cardiac support systems are being used increasingly more due to the growing prevalence of heart failure and cardiogenic shock. Reducing cardiac afterload, intracardiac pressure, and flow support are important factors. Extracorporeal membrane oxygenation (ECMO) and intracardiac microaxial pump systems (Impella) as non-permanent MCS (mechanical circulatory support) are being used increasingly. METHODS: We reviewed the recent literature and developed an international European registry for non-permanent MCS. RESULTS: Life-threatening conditions that are observed preoperatively often include reduced left ventricular function, systemic hypoperfusion, myocardial infarction, acute and chronic heart failure, myocarditis, and valve vitia. Postoperative complications that are commonly observed include severe systemic inflammatory response, ischemia-reperfusion injury, trauma-related disorders, which ultimately may lead to low cardiac output (CO) syndrome and organ dysfunctions, which necessitates a prolonged ICU stay. Choosing the appropriate device for support is critical. The management strategies and complications differ by system. The "heart-team" approach is inevitably needed.However despite previous efforts to elucidate these topics, it remains largely unclear which patients benefit from certain systems, when is the right time to initiate (MCS), which support system is appropriate, what is the optimal level and type of support, which therapeutic additive and supportive strategies should be considered and ultimately, what are the future prospects and therapeutic developments. CONCLUSION: The European cardiac surgical register ImCarS has been established as an IIT with the overall aim to evaluate data received from the daily clinical practice in cardiac surgery. Interested colleagues are cordially invited to join the register. CLINICAL REGISTRATION NUMBER: DRKS00024560. POSITIVE ETHICS VOTE: AZ 246/20 Faculty of Medicine, Justus-Liebig-University-Gießen.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Insuficiência Cardíaca , Coração Auxiliar , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Coração Auxiliar/efeitos adversos , Humanos , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/etiologia , Choque Cardiogênico/terapia , Resultado do Tratamento
12.
ASAIO J ; 68(12): e262-e267, 2022 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-35544446

RESUMO

Patients undergoing explantation of left ventricular assist devices (LVADs) after improvement of myocardial function remain a minority. Nevertheless, considering the growing population of LVAD patients, increasing demand for new explantation strategies is expected. Herein, we present a retrospective review of seven patients undergoing HeartMate3 explantation with the use of a custom-made apical ring plug in four medical centers. The primary outcome was status at intensive care unit discharge. Secondary outcomes included perioperative complications and transfusions. Six out of seven patients were males. The median age at explantation and time on LVAD support was 35 years (range:13-73) and 10 months (range:9-24), respectively. No technical difficulties were experienced during plug implantation via a conventional sternotomy or through a left lateral thoracotomy, either with or without cardiopulmonary bypass. Perioperative transfusions ranged from 0 to 3 units/patient. No re-operations for bleeding, hemorrhagic, embolic, or plug-related infective events were observed. Heparin was started 6 hours after surgery as a bridge to oral anticoagulation (international normalized ratio: 2-2.5). All patients were discharged alive from intensive care unit. This novel plug device for HeartMate3 explantation was successfully and safely implanted in this first patient series. Notwithstanding, its use should still be considered off-label and larger studies are required to investigate its long-term results.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Masculino , Humanos , Feminino , Coração Auxiliar/efeitos adversos , Remoção de Dispositivo , Estudos Retrospectivos , Miocárdio , Esternotomia , Insuficiência Cardíaca/cirurgia , Resultado do Tratamento
13.
J Thorac Cardiovasc Surg ; 163(6): 2120-2127.e5, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35341579

RESUMO

The HeartWare HVAD System (Medtronic) is a durable implantable left ventricular assist device that has been implanted in approximately 20,000 patients worldwide for bridge to transplant and destination therapy indications. In December 2020, Medtronic issued an Urgent Medical Device Communication informing clinicians of a critical device malfunction in which the HVAD may experience a delay or failure to restart after elective or accidental discontinuation of pump operation. Moreover, evolving retrospective comparative effectiveness studies of patients supported with the HVAD demonstrated a significantly higher risk of stroke and all-cause mortality when compared with a newer generation of a commercially available durable left ventricular assist device. Considering the totality of this new information on HVAD performance and the availability of an alternate commercially available device, Medtronic halted the sale and distribution of the HVAD System in June 2021. The decision to remove the HVAD from commercial distribution now requires the use of the HeartMate 3 left ventricular assist system (Abbott, Inc) if a patient previously implanted with an HVAD requires a pump exchange. The goal of this document is to review important differences in the design of the HVAD and HeartMate 3 that are relevant to the medical management of patients supported with these devices, and to assess the technical aspects of an HVAD-to-HeartMate 3 exchange. This document provides the best available evidence that supports best practices.


Assuntos
Coração Auxiliar , Desenho de Equipamento , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Humanos , Estudos Retrospectivos , Acidente Vascular Cerebral/epidemiologia
14.
Ann Thorac Surg ; 113(6): 1770-1777, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35341592

RESUMO

The HeartWare HVAD System (Medtronic) is a durable implantable left ventricular assist device that has been implanted in approximately 20,000 patients worldwide for bridge to transplant and destination therapy indications. In December 2020, Medtronic issued an Urgent Medical Device Communication informing clinicians of a critical device malfunction in which the HVAD may experience a delay or failure to restart after elective or accidental discontinuation of pump operation. Moreover, evolving retrospective comparative effectiveness studies of patients supported with the HVAD demonstrated a significantly higher risk of stroke and all-cause mortality when compared with a newer generation of a commercially available durable left ventricular assist device. Considering the totality of this new information on HVAD performance and the availability of an alternate commercially available device, Medtronic halted the sale and distribution of the HVAD System in June 2021. The decision to remove the HVAD from commercial distribution now requires the use of the HeartMate 3 left ventricular assist system (Abbott, Inc) if a patient previously implanted with an HVAD requires a pump exchange. The goal of this document is to review important differences in the design of the HVAD and HeartMate 3 that are relevant to the medical management of patients supported with these devices, and to assess the technical aspects of an HVAD-to-HeartMate 3 exchange. This document provides the best available evidence that supports best practices.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Acidente Vascular Cerebral , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Humanos , Estudos Retrospectivos , Acidente Vascular Cerebral/etiologia
15.
Eur J Cardiothorac Surg ; 62(1)2022 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-35325091

RESUMO

The HeartWare HVAD System (Medtronic) is a durable implantable left ventricular assist device that has been implanted in approximately 20,000 patients worldwide for bridge to transplant and destination therapy indications. In December 2020, Medtronic issued an Urgent Medical Device Communication informing clinicians of a critical device malfunction in which the HVAD may experience a delay or failure to restart after elective or accidental discontinuation of pump operation. Moreover, evolving retrospective comparative effectiveness studies of patients supported with the HVAD demonstrated a significantly higher risk of stroke and all-cause mortality when compared with a newer generation of a commercially available durable left ventricular assist device. Considering the totality of this new information on HVAD performance and the availability of an alternate commercially available device, Medtronic halted the sale and distribution of the HVAD System in June 2021. The decision to remove the HVAD from commercial distribution now requires the use of the HeartMate 3 left ventricular assist system (Abbott, Inc) if a patient previously implanted with an HVAD requires a pump exchange. The goal of this document is to review important differences in the design of the HVAD and HeartMate 3 that are relevant to the medical management of patients supported with these devices, and to assess the technical aspects of an HVAD-to-HeartMate 3 exchange. This document provides the best available evidence that supports best practices. (J Thorac Cardiovasc Surg 2022;-:1-8).


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Acidente Vascular Cerebral , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Humanos , Estudos Retrospectivos , Acidente Vascular Cerebral/etiologia
17.
Semin Thorac Cardiovasc Surg ; 34(2): 512-516, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34089830

RESUMO

The edge-to-edge mitral valve repair technique, invented by Alfieri and colleagues, introduced valve repair as a treatment option for patients with complex diseases where standard annuloplasty and related repair techniques are insufficient, due to annular calcification and patient frailty. We retrospectively evaluated the results of a transaortic edge-to-edge mitral valve repair (Alfieri stitch) in high-risk patients who were undergoing aortic valve replacement. From February, 2012 to December, 2017, 43 patients underwent transaortic edge-to-edge mitral valve repair with concomitant aortic valve replacement at a single institution. Preoperative and postoperative echocardiograms were compared. Home telephone follow up was conducted and postoperative morbidity was examined, including the need for reoperation, stroke and cardiac arrhythmia. 30-day and long-term survival rates were also determined. Mitral regurgitation (MR) was graded semi-quantitatively as 0 (trace and/or none), mild (1), moderate (2) or moderate to severe (3-4). The patients were 74 ± 7.8 years old. 65% of the patients were male. Mean cardiopulmonary bypass time was 115 ± 37 minutes and mean cross-clamp time was 71 ± 23 minutes. There was a significant improvement in preoperative vs postoperative median MR grade (2 (IQR 2-3) vs 0 (IQR 0-1); P = 0.05). Follow-up transthoracic echocardiograms in 29 patients obtained at a median of 9 months' (range 3 - 19 months') and in 16 patients at a median of 34 months' postoperatively (range 21 - 53 months') showed mild (1 (IQR 1-2)) grade of mitral regurgitation. 30-day survival was 98%. Long term survival at 12 and 24 months' were 88% and 81% respectively. Mitral valve reoperation was conducted in 1 patient (2%), who was suffering of endocarditis. Stroke occurred in 2 patients (7%). Cardiac arrhythmia was observed in 15 patients (35%). 8 patients (19%) suffered from atrial fibrillation and 7 patients (16%) displayed atrioventricular blockage. 10 patients (23%) could be treated conservatively and 5 patients (12%) needed implantation of a pacemaker. Transaortic edge-to-edge mitral valve repair can be safely performed during aortic valve replacement in high-risk patients and improves even long-term MR grade. Postoperative cardiac arrhythmia occurs frequently. 66% of them could be treated successfully by conservative procedures.


Assuntos
Implante de Prótese de Valva Cardíaca , Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral , Acidente Vascular Cerebral , Idoso , Idoso de 80 Anos ou mais , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Anuloplastia da Valva Mitral/efeitos adversos , Anuloplastia da Valva Mitral/métodos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
18.
Artif Organs ; 46(5): 827-837, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34904254

RESUMO

BACKGROUND: Patients receiving left ventricle assist devices (LVADs) as bridge to recovery remain a minority with 1%-5% of LVADs explanted after improvement of myocardial function. Nevertheless, considering the growing population of patients supported with LVADs, an increasing demand of new explantation strategies is expected in the near future. A novel plug for LVAD explantation has been developed and its biocompatibility profile needs to be proved. This study tested the biocompatibility of this novel plug in an in vivo ovine model. METHODS: Six adult Blackhead Persian female sheep received plug implantation on the cardiac apex via minimally invasive approach and were clinically observed up to 90 days. Echocardiography was performed to detect thrombus formation or further plug-related complications. After the observation period, euthanasia was performed and samples including the plug and the surrounding tissues were obtained to be analyzed with correlative light and electron microscopy. Organ necrosis, ischemia and peripheral embolism were investigated. RESULTS: Three animals survived surgery and completed the follow-up time without experiencing clinical complications. Echocardiographic controls excluded the presence of an intracavitary thrombus in the left ventricle (LV). Autopsy confirmed no signs of local infection, LV thrombus or peripheral embolism. Light and electron microscopy revealed an intact epithelium covering a layer of connective tissue on the plug surface facing the heart lumen. CONCLUSIONS: This novel apical plug for LVAD explantation allows for endothelial and connective tissue growth on its ventricular side within 90 days from surgery. Further studies are required to fully demonstrate the biocompatibility of this apical plug and investigate the optimal anticoagulation regimen to be applied after implantation.


Assuntos
Embolia , Insuficiência Cardíaca , Coração Auxiliar , Animais , Remoção de Dispositivo , Estudos de Viabilidade , Feminino , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Humanos , Ovinos
19.
Indian J Thorac Cardiovasc Surg ; 37(5): 514-520, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34511757

RESUMO

OBJECTIVE: A growing number of patients suffering from heart failure is living with a left ventricular assist device (LVAD) and is in the need for non-cardiac surgery. Vascular procedures due to ischemia, bleeding, or other device-related complications may be required and pose a challenge to the caregivers in terms of monitoring and management of these patients. Therefore, we reviewed our experience with LVAD patients undergoing vascular surgery. METHODS: From January 2010 until March 2017, a total of 54 vascular procedures were performed on 41 LVAD patients at our institution. Patient records were reviewed retrospectively in terms of incidence of LVAD-related complications, including thrombosis, stroke, bleeding, wound healing, and survival associated with vascular surgery. The type of surgery was recorded, as well as various clinical demographic variables. RESULTS: Vascular procedures were performed in 35 men (85.4%) and 6 women (14.6%) with LVADs. There were no perioperative strokes, device thromboses, or device malfunctions. Thirty-day mortality overall was 26.8% (eleven patients), with most patients dying within 30 days after LVAD implantation due to multi-organ failure. In 25 procedures (46.3%), a blood transfusion was necessary. CONCLUSION: Patients on LVAD support are a complex cohort with a high risk for perioperative complications. In a setting where device function and anticoagulation are monitored closely, vascular surgery in these patients is feasible with an acceptable perioperative risk.

20.
J Cardiovasc Surg (Torino) ; 62(6): 646-651, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34057162

RESUMO

BACKGROUND: Device exchange to a newer generation left ventricular assist device (LVAD) offers the opportunity to benefit from improved adverse events profiles. We present the three-year results of a patient cohort undergoing VAD upgrades to a new generation device focusing on outcomes and adverse events. METHODS: We present the first series of patients who underwent LVAD upgrade to HeartMate 3™ (Abbott Laboratories; Abbott Park, IL, USA). All operations were performed less invasively. Follow-up time was three years after LVAD exchange. RESULTS: Overall four HeartMate II™ (Abbott Laboratories; Abbott Park, IL, USA) and two HVAD patients underwent LVAD upgrade. In five cases severe infection of the VAD led to device exchange (83%, 5/6). Three-year survival after LVAD exchange was 100% (6/6). In the follow-up examinations one patient showed a single syncope and several low flow alarms (1/6). The remaining five patients showed no technical malfunctions of the LVAD or hemodynamic adverse events (5/6). Four out of five patients whose devices had to be changed due to an infection suffered a local re-infection (4/5), which did not require any further surgical intervention. Four patients were successfully transplanted, and two patients were still on device support at three years after LVAD exchange. CONCLUSIONS: Three-year outcomes and adverse events after LVAD exchange to HeartMate 3™ (Abbott Laboratories). show excellent results. The superior hemocompatibility in terms of pump thrombosis makes the HM3 a favored choice in case of LVAD exchange due previous pump thrombosis. However, in cases of exchange due to device infection the risk of re-infection remains high.


Assuntos
Remoção de Dispositivo , Insuficiência Cardíaca/terapia , Coração Auxiliar , Implantação de Prótese/instrumentação , Função Ventricular Esquerda , Adulto , Idoso , Remoção de Dispositivo/efeitos adversos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Implantação de Prótese/efeitos adversos , Recuperação de Função Fisiológica , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA