Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 93
Filtrar
1.
Ophthalmol Retina ; 2024 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-39048058

RESUMO

OBJECTIVE: To evaluate whether treatment patterns for endophthalmitis after cataract surgery in American Academy of Ophthalmology IRIS® (Intelligent Research in Sight) Registry patients are in line with evidence-based guidelines established by the 1995 Endophthalmitis Vitrectomy Study (EVS), which showed that patients who present with light perception (LP) vision have better visual outcomes with immediate vitrectomy (VIT) compared with vitreous tap with antibiotic injection (TAP). DESIGN: Retrospective cohort study. SUBJECTS: Intelligent Research in Sight Registry patients undergoing cataract surgery between 2014 and 2022 (identified by Current Procedural Terminology codes), presenting with endophthalmitis (identified by International Classification of Diseases 10 codes) within 42 days postcataract surgery, and having a record of being treated with VIT or TAP on the same or 1 day after endophthalmitis diagnosis were identified. METHODS: Potential covariates of age, sex, race, ethnicity, geographic region, insurance status, and visual acuity on the day of endophthalmitis diagnosis were evaluated using multivariable logistic regression. MAIN OUTCOME MEASURES: Treatment with VIT or TAP. RESULTS: Of the 2425 patients who met the inclusion criteria, 14% (345) underwent VIT and 86% (2080) underwent TAP. Notably, 80% of patients (1946) presented with endophthalmitis within 14 days from cataract surgery (median = 6 days). Notably, 66% (173/263) of the patients presenting with LP vision underwent TAP instead of VIT. In a multivariable logistic regression model, receiving VIT instead of TAP was positively associated with poor vision at endophthalmitis presentation (LP - odds ratio [OR] = 5.4; confidence interval [CI], 2.9-10.6; counting fingers, hand motions - OR = 1.9; CI, 1.1-3.6) versus (20/20-20/40) vision; Asian versus White race (OR = 2.6; CI, 1.3-5.2); Hispanic versus non-Hispanic ethnicity (OR = 1.9; CI, 1.1-3.2); living in the West (OR = 1.6; CI, 1.1-2.2) and Midwest (OR = 1.5; CI, 1.1-2.0) (vs. South), but not with age, sex, and insurance coverage (P > 0.05). CONCLUSIONS: In the IRIS Registry, treatment patterns for postcataract surgery endophthalmitis did not match evidence-based recommendations of the EVS, a randomized controlled clinical trial. More work is needed to evaluate whether the current treatment patterns are optimal for patients with postcataract surgery endophthalmitis. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

2.
Ophthalmol Glaucoma ; 7(2): 116-122, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37709048

RESUMO

OBJECTIVE: To examine the longitudinal postoperative outcomes of open versus closed conjunctiva implantation of the XEN45 gel stent. DESIGN: Retrospective multicenter study. SUBJECTS: One hundred ninety-three patients with glaucoma underwent XEN45 implantation via an open or closed conjunctiva approach. METHODS: Data on patient demographics; diagnoses; preoperative and postoperative clinical data; outcome measures, including intraocular pressure (IOP); use of glaucoma medications; visual acuity; and complications were collected. Statistical analyses were performed with P < 0.05 as significant. MAIN OUTCOME MEASURES: Failure was defined as < 20% reduction in IOP from the medicated baseline or a IOP of > 21 mmHg at 2 consecutive visits at postoperative month 1 and beyond, the need for subsequent operative intervention or additional glaucoma surgery, or a catastrophic event, such as loss of light perception. Eyes that had not failed by these criteria and were not on glaucoma medications were considered complete successes. Overall success was defined as those who achieved success either with or without topical medications. RESULTS: Patients were followed for an average of 17 months. Complete success was achieved in 42.5% and 24.7% of the open and closed groups, respectively (P = 0.01). Overall success was achieved in 64.2% and 37.0% of the open and closed groups, respectively (P < 0.001) at the last follow-up. Bleb needling was performed in 12.4% of eyes in the open group compared with 40% of eyes in the closed group. An IOP spike of ≥ 10 mmHg was twice as likely to occur in the closed group compared with the open group during the postoperative period (40% vs. 18%; P = 0.001). CONCLUSIONS: Implantation of XEN45 with opening of the conjunctiva resulted in a lower IOP with greater success and lower needling rate compared with those achieved with the closed conjunctiva technique. Similar rates of postoperative complications and vision loss were noted in each group. Although both procedures provide substantial IOP reduction, the open technique appears to result in higher success rates and fewer postoperative interventions. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma de Ângulo Aberto , Glaucoma , Humanos , Túnica Conjuntiva/cirurgia , Glaucoma/cirurgia , Glaucoma de Ângulo Aberto/cirurgia , Stents , Resultado do Tratamento , Estudos Retrospectivos
3.
Ophthalmology ; 130(7): 702-714, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36889466

RESUMO

TOPIC: Understanding approaches to sustainability in cataract surgery and their risks and benefits. CLINICAL RELEVANCE: In the United States, health care is responsible for approximately 8.5% of greenhouse gas (GHG), and cataract surgery is one of the most commonly performed surgical procedures. Ophthalmologists can contribute to reducing GHG emissions, which lead to a steadily increasing list of health concerns ranging from trauma to food instability. METHODS: We conducted a literature review to identify the benefits and risks of sustainability interventions. We then organized these interventions into a decision tree for use by individual surgeons. RESULTS: Identified sustainability interventions fall into the domains of advocacy and education, pharmaceuticals, process, and supplies and waste. Existing literature shows certain interventions may be safe, cost-effective, and environmentally friendly. These include dispensing medications at home to patients after surgery, multi-dosing appropriate medications, training staff to properly sort medical waste, reducing the number of supplies used during surgery, and implementing immediate sequential bilateral cataract surgery where clinically appropriate. The literature was lacking on the benefits or risks for some interventions, such as switching specific single-use supplies to reusables or implementing a hub-and-spoke-style operating room setup. Many of the advocacy and education interventions have inadequate literature specific to ophthalmology but are likely to have minimal risks. CONCLUSIONS: Ophthalmologists can engage in a variety of safe and effective approaches to reduce or eliminate dangerous GHG emissions associated with cataract surgery. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found after the references.


Assuntos
Extração de Catarata , Catarata , Cristalino , Oftalmologistas , Oftalmologia , Humanos
4.
Prog Retin Eye Res ; 90: 101063, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35398015

RESUMO

Glaucoma is the leading cause of global irreversible blindness, necessitating research for new, more efficacious treatment options than currently exist. Trabecular meshwork (TM) cells play an important role in the maintenance and function of the aqueous outflow pathway, and studies have found that there is decreased cellularity of the TM in glaucoma. Regeneration of the TM with stem cells has been proposed as a novel therapeutic option by several reports over the last few decades. Stem cells have the capacity for self-renewal and the potential to differentiate into adult functional cells. Several types of stem cells have been investigated in ocular regenerative medicine: tissue specific stem cells, embryonic stem cells, induced pluripotent stem cells, and adult mesenchymal stem cells. These cells have been used in various glaucoma animal models and ex vivo models and have shown success in IOP homeostasis and TM cellularity restoration. They have also demonstrated stability without serious side effects for a significant period of time. Based on current knowledge of TM pathology in glaucoma and existing literature regarding stem cell regeneration of this tissue, we propose a human clinical study as the next step in understanding this potentially revolutionary treatment paradigm. The ability to protect and replace TM cells in glaucomatous eyes could change the field forever.


Assuntos
Glaucoma , Células-Tronco Pluripotentes Induzidas , Células-Tronco Mesenquimais , Animais , Glaucoma/patologia , Glaucoma/cirurgia , Humanos , Pressão Intraocular , Regeneração , Malha Trabecular
5.
Asia Pac J Ophthalmol (Phila) ; 10(3): 289-298, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34383720

RESUMO

BACKGROUND: This review explores the bioethical implementation of artificial intelligence (AI) in medicine and in ophthalmology. AI, which was first introduced in the 1950s, is defined as "the machine simulation of human mental reasoning, decision making, and behavior". The increased power of computing, expansion of storage capacity, and compilation of medical big data helped the AI implementation surge in medical practice and research. Ophthalmology is a leading medical specialty in applying AI in screening, diagnosis, and treatment. The first Food and Drug Administration approved autonomous diagnostic system served to diagnose and classify diabetic retinopathy. Other ophthalmic conditions such as age-related macular degeneration, glaucoma, retinopathy of prematurity, and congenital cataract, among others, implemented AI too. PURPOSE: To review the contemporary literature of the bioethical issues of AI in medicine and ophthalmology, classify ethical issues in medical AI, and suggest possible standardizations of ethical frameworks for AI implementation. METHODS: Keywords were searched on Google Scholar and PubMed between October 2019 and April 2020. The results were reviewed, cross-referenced, and summarized. A total of 284 references including articles, books, book chapters, and regulatory reports and statements were reviewed, and those that were relevant were cited in the paper. RESULTS: Most sources that studied the use of AI in medicine explored the ethical aspects. Bioethical challenges of AI implementation in medicine were categorized into 6 main categories. These include machine training ethics, machine accuracy ethics, patient-related ethics, physician-related ethics, shared ethics, and roles of regulators. CONCLUSIONS: There are multiple stakeholders in the ethical issues surrounding AI in medicine and ophthalmology. Attention to the various aspects of ethics related to AI is important especially with the expanding use of AI. Solutions of ethical problems are envisioned to be multifactorial.


Assuntos
Inteligência Artificial , Oftalmologia , Retinopatia Diabética , Glaucoma/diagnóstico , Glaucoma/terapia , Humanos
6.
Neurology ; 97(2): 68-79, 2021 07 13.
Artigo em Inglês | MEDLINE | ID: mdl-33910937

RESUMO

OBJECTIVE: To update the consensus recommendations for reporting of quantitative optical coherence tomography (OCT) study results, thus revising the previously published Advised Protocol for OCT Study Terminology and Elements (APOSTEL) recommendations. METHODS: To identify studies reporting quantitative OCT results, we performed a PubMed search for the terms "quantitative" and "optical coherence tomography" from 2015 to 2017. Corresponding authors of the identified publications were invited to provide feedback on the initial APOSTEL recommendations via online surveys following the principle of a modified Delphi method. The results were evaluated and discussed by a panel of experts and changes to the initial recommendations were proposed. A final survey was recirculated among the corresponding authors to obtain a majority vote on the proposed changes. RESULTS: A total of 116 authors participated in the surveys, resulting in 15 suggestions, of which 12 were finally accepted and incorporated into an updated 9-point checklist. We harmonized the nomenclature of the outer retinal layers, added the exact area of measurement to the description of volume scans, and suggested reporting device-specific features. We advised to address potential bias in manual segmentation or manual correction of segmentation errors. References to specific reporting guidelines and room light conditions were removed. The participants' consensus with the recommendations increased from 80% for the previous APOSTEL version to greater than 90%. CONCLUSIONS: The modified Delphi method resulted in an expert-led guideline (evidence Class III; Grading of Recommendations, Assessment, Development and Evaluations [GRADE] criteria) concerning study protocol, acquisition device, acquisition settings, scanning protocol, funduscopic imaging, postacquisition data selection, postacquisition analysis, nomenclature and abbreviations, and statistical approach. It will be essential to update these recommendations to new research and practices regularly.


Assuntos
Projetos de Pesquisa , Doenças Retinianas/diagnóstico por imagem , Tomografia de Coerência Óptica , Consenso , Técnica Delphi , Humanos , Oftalmologia/métodos
7.
Clin Exp Ophthalmol ; 49(1): 60-69, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33426793

RESUMO

BACKGROUND: Glaucoma filtration surgery (GFS) is limited by subconjunctival, episcleral and scleral fibrosis sealing the trabeculectomy and scarring the filtering bleb. Mitomycin-C (MMC) is commonly applied intraoperatively to the subconjunctival and/or intrascleral space to reduce scarring and promotes GFS success but is associated with postoperative scleral melting and bleb leaks. IP-10 peptide (IP-10p), an ELR-negative CXC chemokine mimetic and inhibitor of fibroblast function, may be an alternative or adjunct to current postoperative GFS treatments. This study sought to determine if IP-10p produces histological changes in tissue remodelling, vascularity and fibrosis that enhance bleb survival after GFS. METHODS: Rabbits underwent tube-assisted filtration surgery on the right eye with either: (a) IP-10p injected into bleb at time of surgery and postoperative days 2, 4 and 7, (b) intraoperative MMC or (c) intraoperative MMC plus IP-10p injected into bleb at time of surgery and postoperative days 2, 4 and 7. Left contralateral eyes were treated with balanced salt solution (BSS). RESULTS: IP-10p-treated blebs demonstrated reduced collagen deposition, cellularity and overall reduction of scar formation compared to BSS-control. Bleb vascularity was reduced compared to BSS-control and MMC treatment groups. Additionally, IP-10p/MMC treated eyes demonstrated an increased number of conjunctival goblet cells in bleb histology compared to the dramatic loss seen with MMC treatment alone. CONCLUSIONS: This study demonstrates that IP-10p significantly reduces histological scarring compared to BSS or MMC alone, does not damage the conjunctiva to the extent of current standards, and may be an alternative or adjunct to MMC for those undergoing GFS.


Assuntos
Cirurgia Filtrante , Glaucoma , Trabeculectomia , Animais , Túnica Conjuntiva/patologia , Modelos Animais de Doenças , Fibrose , Glaucoma/patologia , Glaucoma/cirurgia , Pressão Intraocular , Mitomicina , Coelhos , Cicatrização
8.
Ophthalmol Glaucoma ; 4(4): 343-349, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33321200

RESUMO

PURPOSE: To describe the efficacy and safety of open versus closed conjunctival implantation of the XEN45 Gel Stent (Allergan Inc). DESIGN: Retrospective, multicenter study. PARTICIPANTS: A total of 137 patients with glaucoma who underwent XEN45 implantation via open or closed conjunctival methods. The XEN45 was implanted as a stand-alone procedure or at the time of cataract surgery by 5 surgeons. METHODS: Patient demographics, diagnoses, preoperative and postoperative clinical data, outcome measures including intraocular pressure (IOP), use of glaucoma medications, visual acuity, and complications were collected. Statistical analyses were performed with P < 0.05 as significant. MAIN OUTCOME MEASURES: Failure was defined as less than 20% reduction of IOP from medicated baseline or IOP >21 mmHg at 2 consecutive visits at postoperative month 1 and beyond, the need for subsequent operative intervention or additional glaucoma surgery, or a catastrophic event such as loss of light perception. Eyes that had not failed by these criteria and were not on glaucoma medications were considered complete successes. Eyes that had not failed but required glaucoma medications were defined as qualified successes. RESULTS: Complete success was achieved in 31% and 56% of the closed and open groups, respectively (P = 0.01). Qualified success was achieved in 53% and 71% of the closed and open groups, respectively (P = 0.06). At postoperative month 12, the open conjunctiva group was using fewer glaucoma medications than the closed group (0.9 vs. 1.8, respectively; P = 0.02). At postoperative month 12, the open group had a significantly greater percentage of IOP reduction compared with the closed group (43.1% vs. 24.8%, respectively; P = 0.02). Postoperative needling rates were higher in the closed group compared with the open group (36.1% vs. 11.8%, P = 0.001). CONCLUSIONS: Implantation of the XEN45 with opening of the conjunctiva is a safe and efficacious procedure to lower IOP with comparable success rate and lower needling rate compared with the closed conjunctiva technique. Prospective evaluation of the various methods for XEN45 implantation will allow for further comparison.


Assuntos
Extração de Catarata , Implantes para Drenagem de Glaucoma , Glaucoma de Ângulo Aberto , Túnica Conjuntiva/cirurgia , Glaucoma de Ângulo Aberto/cirurgia , Humanos , Estudos Retrospectivos , Stents/efeitos adversos , Resultado do Tratamento
9.
Retina ; 41(1): 29-36, 2021 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-32251240

RESUMO

PURPOSE: To determine which spectral domain optical coherence tomography biomarkers of idiopathic macular hole (MH) correlate with the postoperative best-corrected visual acuity (BCVA) in anatomically closed MH. METHODS: Retrospective analysis of spectral domain optical coherence tomography scans of 44 patients presenting with MH followed for a mean of 17 months. Widths of MH aperture, base, and ellipsoid zone disruption were calculated from presenting foveal spectral domain optical coherence tomography B-scans. Macular hole base area and ellipsoid zone disruption area were calculated through the custom in-house software. RESULTS: Poorer postoperative BCVA correlated with increased preoperative choroidal hypertransmission (r = 0.503, P = 0.0005), minimum diameter (r = 0.491, P = 0.0007), and base diameter (r = 0.319, P = 0.0348), but not with preoperative ellipsoid zone width (r = 0.199, P = 0.2001). Applying en-face analysis, the BCVA correlated weakly with preoperative ellipsoid zone loss area (r = 0.380, P = 0.013), but not with preoperative MH base area (r = 0.253, P = 0.1058). CONCLUSION: Increased MH minimum diameter, base diameter, base area, and choroidal hypertransmission are correlated with a poorer postoperative BCVA. Ellipsoid zone loss measurements were not consistently correlated with a BCVA. Choroidal hypertransmission width may be an easy-to-visualize predictive imaging biomarker in MH surgery.


Assuntos
Fóvea Central/patologia , Perfurações Retinianas/cirurgia , Tomografia de Coerência Óptica/métodos , Acuidade Visual , Vitrectomia/métodos , Idoso , Feminino , Humanos , Masculino , Período Pós-Operatório , Perfurações Retinianas/diagnóstico , Perfurações Retinianas/fisiopatologia , Estudos Retrospectivos
10.
Transl Vis Sci Technol ; 9(11): 23, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-33150049

RESUMO

Purpose: Mitomycin C is routinely applied during trabeculectomy surgeries to enhance bleb survival after glaucoma filtration surgery. The current approach involves placing cellulose sponges soaked in mitomycin C at a standard concentration onto bare sclera for a predetermined duration, which varies among surgeons. The purpose of this study was to compare the effects of sponge-applied versus intra-Tenon injection of mitomycin C during modified trabeculectomy. Methods: Two groups of five New Zealand White rabbits underwent glaucoma filtration surgery with either preoperative intra-Tenon injection of mitomycin C or intraoperative application of mitomycin C using a cellulose sponge. Postoperative intraocular pressure was recorded weekly, and eyes were enucleated and sent for pathological examination and histological analysis. Results: An intra-Tenon injection of mitomycin C resulted in decreased intraocular pressure measurements and bleb vascularity compared to the controls but increased levels compared to the sponge-applied group. Collagen deposition and cellularity were reduced and the goblet cell population was increased in the intra-Tenon injection group. Conclusions: This study shows that an intra-Tenon injection can be an effective method for administering mitomycin C compared to the standard-of-care approach of mitomycin C being sponge applied onto bare sclera. Mitomycin C injection led to a greater reduction in intraocular pressure and inhibition of fibroblasts. The associated goblet cell population that can lead to increased mitomycin C toxicity-related morbidity was minimized with the intra-Tenon injection compared to the sponge-applied MMC treatment. Therefore, patients with ocular surface disease may benefit from an intra-Tenon injection. Translational Relevance: This project provides a direct, qualitative assessment in an animal model of common techniques within glaucoma filtration surgery for drug delivery to improve surgical success.


Assuntos
Trabeculectomia , Animais , Humanos , Pressão Intraocular , Mitomicina , Coelhos , Esclera , Tonometria Ocular
11.
Telemed J E Health ; 26(12): 1500-1506, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32543326

RESUMO

Background: Teleophthalmology programs are expanding, but have not been adapted into many emergency departments (EDs) in the United States. Introduction: Determining the potential demand for teleophthalmology services in the United States. EDs could enable development of new strategies to improve access to eye care in resource-limited regions. Methods: Telephone surveys were administered to ED physicians and nurses in Florida. Perceptions of ophthalmologist availability, equipment availability, and perceived utility of teleophthalmology services were measured. Results: Responses were from 104 of 207 facilities (50.2%); 88/181 (48.6%) designated as nonrural hospitals (NRHs) and 16/26 (61.5%) as rural hospitals (RHs). NRHs reported a median of 1 ophthalmologist available on call compared with a median of 0 at RHs (p < 0.001). NRHs were more likely to have a slit lamp (98.9% NRH, 50.0% RH; p < 0.001) and tonometer (100% NRH, 75.0% RH; p < 0.001). On a scale from 1 (lowest) to 5, most (68/93; 73.1%) perceived the value of teleophthalmology for remote consults as a 4 or 5. The most common perceived benefit of teleophthalmology use was to provide second/expert opinion (26.5% of responses). The most commonly cited perceived disadvantage was the physical unavailability of an ophthalmologist for examination and follow-up care (35.5% of responses). Discussion: RHs have less access to ophthalmologists and ophthalmic equipment when managing eye-related complaints in the ED. At both RHs and NRHs, providers face limitations in managing eye complaints and perceived teleophthalmology as a potentially valuable tool for remote expert consultation. Conclusions: Results suggest teleophthalmology services may be used to improve access to expert ophthalmic care, particularly in rural communities.


Assuntos
Oftalmologia , Consulta Remota , Telemedicina , Serviço Hospitalar de Emergência , Florida , Humanos , Estados Unidos
12.
FASEB J ; 34(5): 7160-7177, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32259357

RESUMO

The trabecular meshwork (TM) is an ocular tissue that maintains intraocular pressure (IOP) within a physiologic range. Glaucoma patients have reduced TM cellularity and, frequently, elevated IOP. To establish a stem cell-based approach to restoring TM function and normalizing IOP, human adipose-derived stem cells (ADSCs) were induced to differentiate to TM cells in vitro. These ADSC-TM cells displayed a TM cell-like genotypic profile, became phagocytic, and responded to dexamethasone stimulation, characteristic of TM cells. After transplantation into naive mouse eyes, ADSCs and ADSC-TM cells integrated into the TM tissue, expressed TM cell markers, and maintained normal IOP, outflow facility, and extracellular matrix. Cell migration and affinity results indicated that the chemokine pair CXCR4/SDF1 may play an important role in ADSC-TM cell homing. Our study demonstrates the possibility of applying autologous or allogeneic ADSCs and ADSC-TM cells as a potential treatment to restore TM structure and function in glaucoma.


Assuntos
Células-Tronco Adultas/citologia , Células-Tronco Adultas/transplante , Glaucoma/terapia , Malha Trabecular/citologia , Tecido Adiposo/citologia , Células-Tronco Adultas/efeitos dos fármacos , Animais , Câmara Anterior/citologia , Câmara Anterior/imunologia , Apoptose , Humor Aquoso/fisiologia , Diferenciação Celular , Movimento Celular , Células Cultivadas , Quimiotaxia , Dexametasona/farmacologia , Modelos Animais de Doenças , Glaucoma/patologia , Glaucoma/fisiopatologia , Xenoenxertos , Humanos , Técnicas In Vitro , Pressão Intraocular/fisiologia , Camundongos , Fagocitose , Medicina Regenerativa , Malha Trabecular/fisiologia
13.
Sci Rep ; 9(1): 15496, 2019 10 29.
Artigo em Inglês | MEDLINE | ID: mdl-31664148

RESUMO

Observational studies in glaucoma patients can provide important evidence on treatment effects, especially for combination therapies which are often used in reality. But the success relies on the reduction of selection bias through methods such as propensity score (PS) weighting. The objective of this study was to assess the effects of five glaucoma treatments (medication, laser, non-laser surgery (NLS), laser + medication, and NLS + medication) on 1-year intraocular pressure (IOP) change. Data were collected from 90 glaucoma subjects who underwent a single laser, or NLS intervention, and/or took the same medication for at least 6 months, and had IOP measures before the treatment and 12-months after. Baseline IOP was significantly different across groups (p = 0.007) and this unbalance was successfully corrected by the PS weighting (p = 0.81). All groups showed statistically significant PS-weighted IOP reductions, with the largest reduction in NLS group (-6.78 mmHg). Baseline IOP significantly interacted with treatments (p = 0.03), and at high baseline IOP medication was less effective than other treatments. Our findings showed that the 1-year IOP reduction differed across treatment groups and was dependent on baseline IOP. The use of PS-weighted methods reduced treatment selection bias at baseline and allowed valid assessment of the treatment effect in an observational study.


Assuntos
Glaucoma/terapia , Pressão Intraocular , Pontuação de Propensão , Idoso , Terapia Combinada , Feminino , Glaucoma/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade
14.
Ophthalmology ; 126(11): 1511-1516, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31444008

RESUMO

PURPOSE: This study examined whether short-term use of topical nonsteroidal anti-inflammatory drug (NSAID) or steroid therapy affected the efficacy of selective laser trabeculoplasty (SLT). DESIGN: Double-masked, randomized, placebo-controlled, dual-center, multisurgeon trial. PARTICIPANTS: Patients older than 18 years with intraocular pressure (IOP) of more than 18 mmHg for whom the clinician decided SLT was the appropriately indicated therapy were randomized to 1 of 3 groups in a ratio of 1:1:1 as follows: ketorolac 0.5%, prednisolone 1%, or saline tears. METHODS: After SLT, patients randomized into each group were instructed to use an unmarked drop 4 times daily starting the day of SLT and continuing for 4 additional days. The Kruskal-Wallis test and Wilcoxon rank-sum test were used for continuous variables when comparing 2 or 3 treatment groups, respectively. The Fisher exact test was used for categorical variables. MAIN OUTCOME MEASURES: The primary outcome of this study was IOP at 12 weeks. Secondary outcome measures included IOP at 1 and 6 weeks, patient-reported pain, and detectable anterior chamber inflammation. RESULTS: Ninety-six eyes of 85 patients fit inclusion criteria and were enrolled between the 2 sites. The NSAID, steroid, and placebo groups were similar in baseline demographics and baseline IOP (mean, 23.3±3.9 mmHg; P = 0.57). There was no statistically significant difference in IOP decrease among groups at week 6. Both the NSAID and steroid groups showed a statistically significantly greater decrease in IOP at week 12 compared with the placebo group (mean, -6.2±3.1 mmHg, -5.2±2.7 mmHg, and -3±4.3 mmHg, respectively; P = 0.02 [analysis of variance] and P = 0.002 [t test] for NSAID vs. placebo groups; P = 0.02 for steroid vs. placebo groups). CONCLUSIONS: Significantly better IOP reduction at 12 weeks was measured in eyes treated with steroid or NSAID drops after SLT. Short-term postoperative use of NSAID or steroid drops may improve IOP reduction after SLT. Longer-term follow-up studies are indicated.


Assuntos
Anti-Inflamatórios não Esteroides/uso terapêutico , Glaucoma de Ângulo Aberto/cirurgia , Glucocorticoides/uso terapêutico , Cetorolaco/uso terapêutico , Terapia a Laser/métodos , Prednisolona/uso terapêutico , Trabeculectomia/métodos , Administração Oftálmica , Idoso , Método Duplo-Cego , Feminino , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Hipertensão Ocular/tratamento farmacológico , Hipertensão Ocular/fisiopatologia , Soluções Oftálmicas , Período Pós-Operatório , Tonometria Ocular , Malha Trabecular/cirurgia , Resultado do Tratamento
15.
Quant Imaging Med Surg ; 9(5): 769-781, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-31281773

RESUMO

BACKGROUND: The capabilities of visible-light optical coherence tomography (vis-OCT) in noninvasive anatomical and functional retinal imaging have been demonstrated by multiple groups in both rodents and healthy human subjects. Translating laboratory prototypes to an integrated clinical-environment-friendly system is required to explore the full potential of vis-OCT in disease management. METHODS: We developed and optimized a portable vis-OCT system for human retinal imaging in clinical settings. We acquired raster- and circular-scan images from both healthy and diseased human eyes. RESULTS: The new vis-OCT provided high-quality retinal images of both subjects without any known eye diseases and patients with various retinal diseases, including retinal occlusive disease and diabetic retinopathy (DR) over a broad range of ages. CONCLUSIONS: A newly designed vis-OCT system is sufficiently optimized to be suited for routine patients' examinations in clinics. Vis-OCT has the potential to add new anatomical and functional imaging capabilities to ophthalmic clinical care.

17.
Graefes Arch Clin Exp Ophthalmol ; 257(2): 357-362, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30259089

RESUMO

PURPOSE: To analyze the 5-year results of trabectome ab interno trabeculectomy of a single glaucoma center. METHOD: In this retrospective interventional single-center case series, data of 93 patients undergoing ab interno trabeculotomy between September 2010, and December 2012 were included. Kaplan-Meier analysis was performed using success criteria defined as postoperative intraocular pressure (IOP) ≤ 21 mmHg, and > 20% reduction from preoperative IOP, and no need for further glaucoma surgery. Risk factors for failure were identified using Cox proportional hazards ratio (HR). RESULTS: The retention rate for 5-year follow-up was 66%. The cumulative probability of success at 1, 2, 3, 4, and 5 years was 82.6%, 76.7%, 73.9%, 72.3%, and 67.5%. Risk factors for failure were lower baseline IOP (HR = 0.27, P = 0.001), younger age (HR = 0.25, P = 0.02), and higher central corneal thickness (HR = 0.18, P = 0.01). Exfoliative glaucoma was associated with a higher success rate (HR = 0.39, P = 0.02). IOP was decreased significantly from 20.0 ± 5.6 mmHg at baseline to 15.6 ± 4.6 mmHg at 5-year follow-up (P = 0.001). The baseline number of glaucoma medications was 1.8 ± 1.2, which decreased to 1.0 ± 1.2 medications at 5 years. CONCLUSION: Trabectome surgery was associated with a good long-term efficacy and safety profile in this single-center case series with a high retention rate.


Assuntos
Catarata/complicações , Glaucoma de Ângulo Aberto/cirurgia , Pressão Intraocular/fisiologia , Facoemulsificação/métodos , Trabeculectomia/métodos , Acuidade Visual/fisiologia , Idoso , Feminino , Seguimentos , Glaucoma de Ângulo Aberto/complicações , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Masculino , Fatores de Tempo , Resultado do Tratamento
18.
Ophthalmology ; 125(9): e61, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30143100
19.
Br J Ophthalmol ; 102(3): 358-363, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28814418

RESUMO

BACKGROUND/AIMS: The objective of this study is to evaluate the accuracy and speed of trainees and experienced glaucoma specialists using the MatchedFlicker software against the manual examination of stereoscopic disc photographs for detecting glaucomatous optic disc change. METHODS: Three experienced glaucoma specialists, two resident ophthalmologists and one glaucoma fellow from multiple institutions independently evaluated the same 140 image pairs from 100 glaucomatous/ocular hypertensive eyes using a handheld stereo viewer and the MatchedFlicker programme. Fifty had progression to glaucoma as determined by the Ocular Hypertension Treatment Study (OHTS) Optic Disc Reading Group and endpoint committee, and 50 more were negative controls for progression with photos taken a few minutes apart. Twenty photo pairs from each of the two groups were duplicated for reviewer variability analysis. The initial viewing method was randomised and then alternated for each group of 70 image pairs. Reviewer accuracy and evaluation time for each method were measured. RESULTS: Evaluators averaged 8.6 s faster per image pair (26%) with the MatchedFlicker programme than with the stereo viewer (p=0.0007). Evaluators correctly identified more image pairs when using the MatchedFlicker software over the stereo viewer (p=0.0003). There was no significant difference between the expert and trainee group in speed or overall accuracy for either method. Experts were significantly more consistent than trainees with the duplicate image pairs (p=0.029). Trainees appeared more reluctant to designate eyes as showing glaucoma progression than experts. CONCLUSIONS: Both expert glaucoma specialists and ophthalmologists in various stages of training had greater accuracy and speed with the MatchedFlicker programme than with a handheld stereoscopic viewer.


Assuntos
Diagnóstico por Computador/métodos , Glaucoma de Ângulo Aberto/diagnóstico , Internato e Residência , Oftalmologistas , Disco Óptico/patologia , Doenças do Nervo Óptico/diagnóstico , Fotografação/métodos , Progressão da Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Hipertensão Ocular/diagnóstico , Oftalmologia/educação , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Transtornos da Visão/diagnóstico , Transtornos da Visão/fisiopatologia , Campos Visuais/fisiologia
20.
J Cataract Refract Surg ; 43(11): 1391-1398, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-29223227

RESUMO

PURPOSE: To measure the waste generation and lifecycle environmental emissions from cataract surgery via phacoemulsification in a recognized resource-efficient setting. SETTING: Two tertiary care centers of the Aravind Eye Care System in southern India. DESIGN: Observational case series. METHODS: Manual waste audits, purchasing data, and interviews with Aravind staff were used in a hybrid environmental lifecycle assessment framework to quantify the environmental emissions associated with cataract surgery. Kilograms of solid waste generated and midpoint emissions in a variety of impact categories (eg, kilograms of carbon dioxide equivalents). RESULTS: Aravind generates 250 grams of waste per phacoemulsification and nearly 6 kilograms of carbon dioxide-equivalents in greenhouse gases. This is approximately 5% of the United Kingdom's phaco carbon footprint with comparable outcomes. A majority of Aravind's lifecycle environmental emissions occur in the sterilization process of reusable instruments because their surgical system uses largely reusable instruments and materials. Electricity use in the operating room and the Central Sterile Services Department (CSSD) accounts for 10% to 25% of most environmental emissions. CONCLUSIONS: Surgical systems in most developed countries and, in particular their use of materials, are unsustainable. Results show that ophthalmologists and other medical specialists can reduce material use and emissions in medical procedures using the system described here.


Assuntos
Pegada de Carbono , Extração de Catarata , Facoemulsificação , Catarata , Gases de Efeito Estufa , Humanos , Cristalino , Oftalmologia , Reino Unido
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA