Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Feline Med Surg ; 26(3): 1098612X241230941, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38511293

RESUMO

OBJECTIVES: The main objective of this study was to compare the postoperative analgesic effects of grapiprant with those of robenacoxib in cats undergoing ovariohysterectomy (OVH). METHODS: In total, 37 female cats (age range 4 months-10 years, weighing ⩾2.5 kg) were enrolled in a prospective, randomized, masked, non-inferiority (NI) clinical trial. Cats received oral robenacoxib (1 mg/kg) or grapiprant (2 mg/kg) 2 h before OVH. Analgesia was assessed via the Feline Grimace Scale (FGS), the Glasgow Composite Measure Pain Scale-Feline (CMPS-F), von Frey monofilaments (vFFs) and pressure algometry (ALG) 2 h before treatment administration, at extubation, and 2, 4, 6, 8, 18 and 24 hours after extubation. Hydromorphone (<8 h postoperatively) or buprenorphine (>18 h postoperatively) were administered to cats with scores of ⩾5/20 on CMPS-F and/or ⩾4/10 on FGS. NI margins for CMPS-F and vFFs were set at 3 and -0.2, respectively. A mixed-effect ANOVA was used for FGS scores (P <0.05). Data are reported as mean ± SEM. RESULTS: The data from 33 cats were analyzed. The upper limit of the 95% confidence interval (CI) (0.35) was less than the NI margin of 3 for CMPS-F, and the lower limit of the 95% CI (0.055) was greater than the NI margin of -0.2 for vFFs, indicating NI of grapiprant. The FGS scores were greater than baseline at extubation for both treatments (1.65 ± 0.63; P = 0.001); however, there was no difference between treatments. There was no difference between treatments, nor treatment by time interaction, for vFFs (P <0.001). The CMPS-F scores for both treatments were higher at extubation but returned to baseline after 4 h (P <0.001). For ALG, there was no difference in treatment or treatment by time interaction. The robenacoxib group had lower pressure readings at extubation and 6 h compared with baseline. CONCLUSIONS AND RELEVANCE: These results indicate that grapiprant was non-inferior to robenacoxib for mitigating postsurgical pain in cats after OVH performed via ventral celiotomy. The impact of grapiprant for analgesia in OVH via the flank is unknown.


Assuntos
Analgésicos , Benzenossulfonamidas , Doenças do Gato , Difenilamina/análogos & derivados , Imidazóis , Fenilacetatos , Piridinas , Compostos de Sulfonilureia , Gatos , Animais , Feminino , Ovariectomia/veterinária , Estudos Prospectivos , Histerectomia/veterinária , Dor Pós-Operatória/tratamento farmacológico , Dor Pós-Operatória/prevenção & controle , Dor Pós-Operatória/veterinária , Doenças do Gato/tratamento farmacológico , Doenças do Gato/cirurgia
2.
J Vet Pharmacol Ther ; 46(5): 269-275, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37493273

RESUMO

Both pet and research pigs can suffer from some degree of pain from surgery, injuries, or osteoarthritis (OA). Despite this, there is a paucity of data on safe and effective analgesia agents in pigs. Grapiprant is an EP4 antagonist that blocks the action of the pro-inflammatory prostanoid, PGE2 . It has shown efficacy in attenuating pain associated with ovariohysterectomy and OA in dogs. However, there are no data regarding grapiprant in pigs. Therefore, the pharmacokinetic profile of orally administered grapiprant to juvenile pigs (Sus scrofa domestica) was evaluated in this study. Seven juvenile pigs received 12 mg/kg grapiprant orally. Blood was collected from an indwelling jugular catheter using the push-pull method at set timepoints up to 48 hours. Sample analysis was performed with high-performance liquid chromatography. Mean grapiprant plasma concentration was 164.3 ± 104.7 ng/mL which occurred at 0.8 ± 0.3 h. This study demonstrated that grapiprant concentrations consistent with analgesia in dogs were reached at this dosage in pigs. Further studies are needed to evaluate the efficacy of grapiprant in pigs.


Assuntos
Doenças do Cão , Osteoartrite , Doenças dos Suínos , Animais , Cães , Suínos , Compostos de Sulfonilureia/farmacocinética , Dor/veterinária , Manejo da Dor/veterinária , Osteoartrite/veterinária , Sus scrofa
3.
Vet Clin North Am Exot Anim Pract ; 25(1): 297-319, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34823695

RESUMO

With their increase in popularity in North America as pets, miniature companion pigs are in need of veterinary professionals familiar with sedation and anesthesia for the species. This article provides a review of the agents used for sedation, premedication, induction, and maintenance of anesthesia for miniature companion pigs. This review also covers species-specific anatomic and physiologic factors of miniature companion pigs with respect to administration of anesthetics, endotracheal intubation, anesthetic maintenance, and common complications so that the reader can make an informed anesthetic plan for the species.


Assuntos
Anestesia , Anestésicos , Anestesia/veterinária , Animais , Suínos
4.
Front Surg ; 8: 637268, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33987199

RESUMO

The objective of this study was to evaluate changes in peak reverse torque (PRT) of the locking head screws that occur over time. A locking plate construct, consisting of an 8-hole locking plate and 8 locking screws, was used to stabilize a tibia segmental bone defect in a goat model. PRT was measured after periods of 3, 6, 9, and 12 months of ambulation. PRT for each screw was determined during plate removal. Statistical analysis revealed that after 6 months of loading, locking screws placed in position no. 4 had significantly less PRT as compared with screws placed in position no. 5 (p < 0.05). There were no statistically significant differences in PRT between groups as a factor of time (p > 0.05). Intracortical fractures occurred during the placement of 151 out of 664 screws (22.7%) and were significantly more common in the screw positions closest to the osteotomy (positions 4 and 5, p < 0.05). Periosteal and endosteal bone reactions and locking screw backout occurred significantly more often in the proximal bone segments (p < 0.05). Screw backout significantly, negatively influenced the PRT of the screws placed in positions no. 3, 4, and 5 (p < 0.05). The locking plate-screw constructs provided stable fixation of 2.5-cm segmental tibia defects in a goat animal model for up to 12 months.

5.
J Zoo Wildl Med ; 43(3): 566-72, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23082520

RESUMO

Laparoscopic ovariectomy was performed in seven tigers with the use of a vessel-sealing device and a three-port technique. A comparison group of seven tigers that underwent traditional ovariohysterectomy was assembled with the use of a medical records search. Mean operative times for laparoscopic ovariectomy were compared to standard ovariohysterectomy, and mean combined laparoscopic incision length compared to standard ovariohysterectomy incision lengths. Significance was set at P < or = 0.05. Mean surgical time for laparoscopic ovariectomy (82 min, range 71-126 min) was significantly shorter than standard ovariohysterectomy surgical time (129 min, range 80-165 min, P = 0.007). Mean combined laparoscopic incision length (8.07 cm, range 3.80-9.50 cm) was significantly shorter than the mean incision length for standard ovariohysterectomy (13.57 cm, range 12.00-20.00 cm, P = 0.009). There were no clinically important complications observed in either group. Laparoscopic ovariectomy has a significantly shorter surgical time and combined incision length compared to standard ovariohysterectomy in tigers, and appears to be a safe and rapid sterilization method for tigers. Equipment cost and the necessity for advanced training may limit its use in some institutions. Further prospective evaluation is warranted to determine whether it is associated with decreased morbidity, mortality, or cost.


Assuntos
Laparoscopia/veterinária , Ovariectomia/veterinária , Tigres , Animais , Feminino , Laparoscopia/instrumentação , Laparoscopia/métodos , Ovariectomia/instrumentação , Ovariectomia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA