Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Vasc Surg ; 75(3): 1021-1029.e2, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34923068

RESUMO

OBJECTIVE: We evaluated whether a combination of intraoperative contrast-enhanced cone beam computed tomography (ceCBCT) and postoperative contrast-enhanced ultrasound (CEUS) after infrarenal endovascular abdominal aortic aneurysm repair (EVAR) could reduce late stent graft-related complications and, consequently, reintervention. METHODS: All consecutive patients who had received infrarenal bifurcated stent grafts in our hybrid room (IGS 730; GE Healthcare, Île-de-France, France) during two discrete periods were included in the present study. From November 2012 to September 2013, two-dimensional completion angiography was performed after each EVAR, followed by computed tomography angiography (CTA) before discharge (group 1). From October 2013 to January 2015, intraoperative ceCBCT was performed, followed by CEUS within the first postoperative days (group 2). Comparative analyses of the outcomes were performed. The primary endpoint was late stent graft-related complications, a composite factor incorporating aneurysm-related death, type I or III endoleaks, kink or occlusion of the iliac limb, and aortic sac enlargement after the first 30 postoperative days. The secondary endpoint was all stent graft-related reinterventions. All-cause and aneurysm-related deaths were also recorded. RESULTS: Overall, 100 consecutive patients (50 each in groups 1 and 2) were enrolled, with a median follow-up of 60 months (interquartile range, 41-69 months). At 60 months after the index procedure, the freedom from late stent graft-related complications in each group was 61.6% (95% confidence interval [CI], 47.0%-80.6%) for group 1 and 81.7% (95% CI, 70.1%-95.2%) for group 2 (P = .033). The use of intraoperative ceCBCT was independently associated with a reduced rate of late stent graft-related complications on multivariate analysis (hazard ratio, 0.39; 95% CI, 0.16-0.95; P = .038) but did not appear to significantly protect against stent graft-related reinterventions (hazard ratio, 0.53; 95% CI, 0.20-1.39; P = .198) or all-cause death (P = .47). CONCLUSIONS: To the best of our knowledge, the present study is the first to report the influence of routine ceCBCT on late outcomes after EVAR. The use of ceCBCT shows the potential for reducing late stent graft-related complications associated.


Assuntos
Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Aortografia , Implante de Prótese Vascular , Tomografia Computadorizada de Feixe Cônico , Procedimentos Endovasculares , Cuidados Intraoperatórios , Idoso , Idoso de 80 Anos ou mais , Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/prevenção & controle , Valor Preditivo dos Testes , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Stents , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia
2.
J Endovasc Ther ; 19(5): 648-55, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23046331

RESUMO

PURPOSE: To evaluate contrast-enhanced ultrasound (CEUS) as an effective alternative to computed tomographic angiography (CTA) during follow-up after fenestrated endovascular aneurysm repair (EVAR) of juxtarenal aortic aneurysms. METHODS: Between January 2008 and April 2011, 62 patients (all men; mean age 72 years) underwent fenestrated EVAR follow-up with both CTA and CEUS. In a retrospective analysis, the first CTA and CEUS postoperative examinations after EVAR were compared for endoleak detection, aneurysm sac diameter, and target vessel patency. The examinations were performed within 30 days of the procedure and the interval between the 2 scans was <7 days. Only fenestrated endografts with up to 3 fenestrations (with or without a scallop) were eligible so that the entire implant could be visualized with standard abdominal ultrasound. RESULTS: The mean diameters of the aneurysm sac were 56.58±8.56 mm with CEUS and 57.70±8.59 mm with CTA. The mean difference in aneurysm sac diameter was -1.13±3.19 mm (95% CI -0.34 to -1.92), with CTA measurements tending to be slightly larger. Bland-Altman plots showed good agreement between the imaging modalities with respect to aneurysm sac diameter (Spearman correlation coefficient r(s)=0.921, p<0.01). Endoleaks were detected by CTA in 7 (11.3%) of 62 patients and by CEUS in 6 (9.7%). In 59 (95.16%) cases, the tests agreed, and their equivalence was confirmed by binomial distribution testing. There was complete agreement between CEUS and CTA in the assessment of target vessels (144/146 patent target arteries; 1 had a significant stenosis and another was thrombosed). CONCLUSION: CEUS is as accurate as CTA in endoleak detection, abdominal aortic aneurysm diameter measurement, and the evaluation of target vessels during surveillance of fenestrated stent-grafts. Although it cannot yet be proposed as the only imaging modality during follow-up, CEUS could be usefully employed with the self-evident advantage of reducing lifetime exposure to ionizing radiation.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Aortografia/métodos , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Meios de Contraste , Procedimentos Endovasculares/instrumentação , Fosfolipídeos , Stents , Hexafluoreto de Enxofre , Tomografia Computadorizada por Raios X , Ultrassonografia Doppler em Cores , Idoso , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Implante de Prótese Vascular/efeitos adversos , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , França , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/etiologia , Humanos , Masculino , Valor Preditivo dos Testes , Desenho de Prótese , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA