Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 68
Filtrar
1.
J Neurol ; 271(2): 995-1003, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37907727

RESUMO

OBJECTIVE: The absence of MRI-lesion reduces considerably the probability of having an excellent outcome (International League Against Epilepsies [ILAE] class I-II) after epilepsy surgery. Surgical success in magnetic-resonance imaging (MRI)-negative cases relies therefore mainly on non-invasive techniques such as positron-emission tomography (PET), subtraction ictal/inter-ictal single-photon-emission-computed-tomography co-registered to MRI (SISCOM), electric source imaging (ESI) and morphometric MRI analysis (MAP). We were interested in identifying the optimal imaging technique or combination to achieve post-operative class I-II in patients with MRI-negative focal epilepsy. METHODS: We identified 168 epileptic patients without MRI lesion. Thirty-three (19.6%) were diagnosed with unifocal epilepsy, underwent surgical resection and follow-up ⩾ 2 years. Sensitivity, specificity, predictive values, and diagnostic odds ratio (OR) were calculated for each technique individually and in combination (after co-registration). RESULTS: 23/33 (70%) were free of disabling seizures (75.0% with temporal and 61.5% extratemporal lobe epilepsy). None of the individual modalities presented an OR > 1.5, except ESI if only patients with interictal epileptiform discharges (IEDs) were considered (OR 3.2). On a dual combination, SISCOM with ESI presented the highest outcome (OR = 6). MAP contributed to detecting indistinguishable focal cortical dysplasia in particular in extratemporal epilepsies with a sensitivity of 75%. Concordance of PET, ESI on interictal epileptic discharges, and SISCOM was associated with the highest chance for post-operative seizure control (OR = 11). CONCLUSION: If MRI is negative, the chances to benefit from epilepsy surgery are almost as high as in lesional epilepsy, provided that multiple established non-invasive imaging tools are rigorously applied and co-registered together.


Assuntos
Epilepsias Parciais , Epilepsia , Humanos , Eletroencefalografia/métodos , Epilepsias Parciais/diagnóstico por imagem , Epilepsias Parciais/cirurgia , Epilepsia/cirurgia , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Convulsões
2.
Epilepsia Open ; 8(4): 1622-1627, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37873557

RESUMO

In patients with drug-resistant epilepsy who are considering surgery, intracranial EEG (iEEG) helps delineate the putative epileptogenic zone. In a minority of patients, iEEG fails to identify seizure onsets. In such cases, it might be worthwhile to reimplant more iEEG electrodes. The consequences of such a strategy for the patient are unknown. We matched 12 patients in whom the initially implanted iEEG electrodes did not delineate the seizure onset zone precisely enough to offer resective surgery, and in whom additional iEEG electrodes were implanted during the same inpatient stay, to controls who did not undergo reimplantation. Seven cases and eight controls proceeded to resective surgery. No intracranial infection occurred. One control suffered an intracranial hemorrhage. Three cases and two controls suffered from a post-operative neurological or neuropsychological deficit. We found no difference in post-operative seizure control between cases and controls. Compared to an ILAE score of 5 (ie, stable seizure frequency in the absence of resective surgery), cases showed significant improvement. Reimplantation of iEEG electrodes can offer the possibility of resective epilepsy surgery to patients in whom the initial iEEG investigation was inconclusive, without compromising on the risk of complications or seizure control.


Assuntos
Eletrocorticografia , Epilepsia , Humanos , Epilepsia/cirurgia , Eletrodos , Reimplante , Convulsões
3.
Brain Commun ; 5(3): fcad124, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37151228

RESUMO

Objectively estimating disease severity and treatment success is a main problem in outpatient managing of epilepsy. Self-reported seizures diaries are well-known to underestimate the actual seizure count, and repeated EEGs might not show interictal epileptiform discharges (IEDs), although patients suffer from seizures. In this prospective study, we investigate the potential of microstate analysis to monitor epilepsy patients independently of their IED count. From our databank of candidates for epilepsy surgery, we included 18 patients who underwent controlled resting EEG sessions (with eyes closed, 30 min), at around the same time of the day, during at least four days (range: 4-8 days; mean: 5). Nine patients with temporal foci, six with extratemporal foci, and three with generalized epilepsy were included. Each patient's IEDs were marked and the topographic voltage maps of the IED peaks were averaged, and an individual average spike topography (AST) was created. The AST was then backfitted to each timepoint of the whole EEG resulting in the Spike-Microstate (SMS). The presence of the SMS in the residual EEG outside of the short IEDs epochs was determined for each recording session in each patient and correlated with the occurrence of the IEDs across all recording session, as well as with the drug charge of each day. Overall, SMS was much more represented in the routine EEG than the IEDs: they were identified 262 times more often than IEDs. The SMS time coverage correlated significantly with the IED occurrence rate (rho = 0.56; P < 0.001). If only patients with focal epilepsy were considered, this correlation was even higher rho = 0.69 (P < 0.001). Drug charge per day did not correlate with SMS. In this proof-of-concept study, the time coverage of SMS correlated strongly with the occurrence rate of the IEDs, they can be retrieved in the scalp EEG at a much higher occurrence rate. We conclude that SMS, once obtained for a given patient, are a more abundant marker of hidden epileptic activity than IEDs, in particular in focal epilepsy, and can be used also in absence of IEDs. Future larger studies are needed to verify its potential as monitoring tool and to determine cut-off values when drug protection becomes imperfect.

4.
Epilepsia ; 64(4): 951-961, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36346269

RESUMO

OBJECTIVE: Electric source imaging (ESI) of interictal epileptiform discharges (IEDs) has shown significant yield in numerous studies; however, its implementation at most centers is labor- and cost-intensive. Semiautomatic ESI analysis (SAEA) has been proposed as an alternative and has previously shown benefit. Computer-assisted automatic spike cluster retrieval, averaging, and source localization are carried out for each cluster and are then reviewed by an expert neurophysiologist, to determine their relevance for the individual case. Here, we examine its yield in a prospective single center study. METHOD: Between 2017 and 2022, 122 patients underwent SAEA. Inclusion criteria for the current study were unifocal epilepsy disorder, epilepsy surgery with curative purpose, and postoperative follow-up of 2 years or more. All patients (N=40) had continuous video-electroencephalographic (EEG) monitoring with 37 scalp electrodes, which underwent SAEA. Forty patients matched our inclusion criteria. RESULTS: Twenty patients required intracranial monitoring; 13 were magnetic resonance imaging (MRI)-negative. Mean duration of analyzed EEG was 4.3 days (±3.1 days), containing a mean of 12 749 detected IEDs (±22 324). The sensitivity, specificity, and accuracy of SAEA for localizing the epileptogenic focus of the entire group were 74.3%, 80%, and 75%, respectively, leading to an odds ratio (OR) of 11.5 to become seizure-free if the source was included in the resection volume (p < .05). In patients with extratemporal lobe epilepsy, our results indicated an accuracy of 68% (OR=11.7). For MRI-negative patients (n = 13) and patients requiring intracranial EEG (n = 20), we found a similarly high accuracy of 84.6% (OR=19) and 75% (OR = 15.9), respectively. SIGNIFICANCE: In this prospective study of SAEA of long-term video-EEG, spanning several days, we found excellent localizing information and a high yield, even in difficult patient groups. This compares favorably to high-density ESI, most likely due to marked improved signal-to-noise ratio of the averaged IEDs. We propose including ESI, or SAEA, in the workup of all patients who are referred for epilepsy surgery.


Assuntos
Epilepsias Parciais , Epilepsia , Humanos , Estudos Prospectivos , Eletroencefalografia/métodos , Epilepsia/diagnóstico por imagem , Epilepsia/cirurgia , Epilepsias Parciais/cirurgia , Convulsões/diagnóstico por imagem , Convulsões/cirurgia , Imageamento por Ressonância Magnética/métodos
5.
Clin Neurophysiol Pract ; 7: 245-251, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36062078

RESUMO

Objective: The goal of this study was to investigate the diagnostic utility of electric source imaging (ESI) in the presurgical evaluation of children with focal cortical dysplasia (FCD) and to compare it with other imaging techniques. Methods: Twenty patients with epilepsy onset before 18 years, surgically treated focal epilepsy with a minimal follow-up of 2 years, and histologically proven FCD were retrospectively selected. All patients underwent MRI, positron emission tomography (PET), and 16 patients also had ictal single-photon emission computed tomography (iSPECT). ESI, using EEG with 64 electrodes or more (HD-ESI), was performed in all 20 patients. We determined sensitivity, specificity and accuracy of ESI, and compared its yield to that of other imaging techniques. Results: Twelve patients were seizure-free post-operatively (60%). Among all patients, highest localization accuracy (80%) was obtained with ESI, followed by PET and iSPECT (75%). When results from ESI and SPECT were concordant 100% of patients achieved Engel I outcome. If ESI and PET showed concordant localization, 90% of patients achieved postoperative seizure freedom. Conclusions: Our findings demonstrate that HD-ESI allows accurate localization of the epileptogenic zone in patients with FCD. Significance: In combination with other imaging modalities, ESI helps with planning a more accurate surgery and therefore, the chances of postoperative seizure control are higher. Since it is based on EEG recordings, it does not require sedation, which is particularly interesting in pediatric patients. ESI represents an important imaging tool in focal epilepsies due to cortical dysplasia, which might be difficult to detect on standard imaging.

6.
Brain Struct Funct ; 227(3): 901-911, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34817680

RESUMO

Temporal lobe epilepsy (TLE) is associated with brain pathology extending beyond temporal lobe structures. We sought to look for informative patterns of brain tissue properties in TLE that go beyond the established morphometry differences. We hypothesised that volume differences, particularly in hippocampus, will be paralleled by changes in brain microstructure. The cross-sectional study included TLE patients (n = 25) from a primary care center and sex-/age-matched healthy controls (n = 55). We acquired quantitative relaxometry-based magnetic resonance imaging (MRI) data yielding whole-brain maps of grey matter volume, magnetization transfer (MT) saturation, and effective transverse relaxation rate R2* indicative for brain tissue myelin and iron content. For statistical analysis, we used the computational anatomy framework of voxel-based morphometry and voxel-based quantification. There was a positive correlation between seizure activity and MT saturation measures in the ipsilateral hippocampus, paralleled by volume differences bilaterally. Disease duration correlated positively with iron content in the mesial temporal lobe, while seizure freedom was associated with a decrease of iron in the very same region. Our findings demonstrate the link between TLE clinical phenotype and brain anatomy beyond morphometry differences to show the impact of disease burden on specific tissue properties. We provide direct evidence for the differential effect of clinical phenotype characteristics on processes involving tissue myelin and iron in mesial temporal lobe structures. This study offers a proof-of-concept for the investigation of novel imaging biomarkers in focal epilepsy.


Assuntos
Epilepsia do Lobo Temporal , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Estudos Transversais , Epilepsia do Lobo Temporal/diagnóstico por imagem , Epilepsia do Lobo Temporal/patologia , Hipocampo/diagnóstico por imagem , Hipocampo/patologia , Humanos , Ferro , Imageamento por Ressonância Magnética/métodos , Bainha de Mielina , Fenótipo
7.
Seizure ; 92: 244-251, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34626920

RESUMO

PURPOSE: To study the accuracy of automated interictal EEG source localisation based on high-density EEG, and to compare it to low-density EEG. METHODS: Thirty patients operated for pharmacoresistant focal epilepsy were retrospectively examined. Twelve months after resective brain surgery, 18 were seizure-free or had 'auras' only, while 12 had persistence of disabling seizures. Presurgical 257-channel EEG lasting 3-20 h was down-sampled to 25, 40, and 204 channels for separate analyses. For each electrode setup, interictal spikes were detected, clustered, and averaged automatically before validation by an expert reviewer. An individual 6-layer finite difference head model and the standardised low-resolution electromagnetic tomography were used to localise the maximum source activity of the most prevalent spike. Sublobar concordance with the resected brain area was visually assessed and related to favourable vs. unfavourable postsurgical outcome. RESULTS: Depending on the EEG setup, epileptic spikes were detected in 21-24 patients (70-80%). The median number of single spikes per average was 470 (range 17-15,066). Diagnostic sensitivity of EEG source localisation was 58-75%, specificity was 50-67%, and overall accuracy was 55-71%. There were no significant differences between low- and high-density EEG setups with 25 to 257 electrodes. CONCLUSION: Automated high-density EEG source localisation provides meaningful information in the majority of cases. With hundreds of single spikes averaged, diagnostic accuracy is similar in high- and low-density EEG. Therefore, low-density EEG may be sufficient for interictal EEG source localisation if high numbers of spikes are available.


Assuntos
Eletroencefalografia , Epilepsias Parciais , Mapeamento Encefálico , Epilepsias Parciais/diagnóstico , Epilepsias Parciais/cirurgia , Humanos , Imageamento por Ressonância Magnética , Estudos Retrospectivos , Convulsões/diagnóstico
8.
Brain Commun ; 3(3): fcab209, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34541534

RESUMO

Interictal high-frequency oscillations are discussed as biomarkers for epileptogenic brain tissue that should be resected in epilepsy surgery to achieve seizure freedom. The prospective classification of tissue sampled by individual electrode contacts remains a challenge. We have developed an automated, prospective definition of clinically relevant high-frequency oscillations in intracranial EEG from Montreal and tested it in recordings from Zurich. We here validated the algorithm on intracranial EEG that was recorded in an independent epilepsy centre so that the analysis was blinded to seizure outcome. We selected consecutive patients who underwent resective epilepsy surgery in Geneva with post-surgical follow-up > 12 months. We analysed long-term recordings during sleep that we segmented into intervals of 5 min. High-frequency oscillations were defined in the ripple (80-250 Hz) and the fast ripple (250-500 Hz) frequency bands. Contacts with the highest rate of ripples co-occurring with fast ripples designated the relevant area. As a validity criterion, we calculated the test-retest reliability of the high-frequency oscillations area between the 5 min intervals (dwell time ≥50%). If the area was not fully resected and the patient suffered from recurrent seizures, this was classified as a true positive prediction. We included recordings from 16 patients (median age 32 years, range 18-53 years) with stereotactic depth electrodes and/or with subdural electrode grids (median follow-up 27 months, range 12-55 months). For each patient, we included several 5 min intervals (median 17 intervals). The relevant area had high test-retest reliability across intervals (median dwell time 95%). In two patients, the test-retest reliability was too low (dwell time < 50%) so that outcome prediction was not possible. The area was fully included in the resected volume in 2/4 patients who achieved post-operative seizure freedom (specificity 50%) and was not fully included in 9/10 patients with recurrent seizures (sensitivity 90%), leading to an accuracy of 79%. An additional exploratory analysis suggested that high-frequency oscillations were associated with interictal epileptic discharges only in channels within the relevant area and not associated in channels outside the area. We thereby validated the automated procedure to delineate the clinically relevant area in each individual patient of an independently recorded dataset and achieved the same good accuracy as in our previous studies. The reproducibility of our results across datasets is promising for a multicentre study to test the clinical application of high-frequency oscillations to guide epilepsy surgery.

9.
Sci Rep ; 11(1): 426, 2021 01 11.
Artigo em Inglês | MEDLINE | ID: mdl-33432073

RESUMO

Facial expressions of emotions have been shown to modulate early ERP components, in particular the N170. The underlying anatomical structure producing these early effects are unclear. In this study, we examined the N170 enhancement for fearful expressions in healthy controls as well as epileptic patients after unilateral left or right amygdala resection. We observed a greater N170 for fearful faces in healthy participants as well as in individuals with left amygdala resections. By contrast, the effect was not observed in patients who had undergone surgery in which the right amygdala had been removed. This result demonstrates that the amygdala produces an early brain response to fearful faces. This early response relies specifically on the right amygdala and occurs at around 170 ms. It is likely that such increases are due to a heightened response of the extrastriate cortex that occurs through rapid amygdalofugal projections to the visual areas.


Assuntos
Tonsila do Cerebelo/fisiologia , Reconhecimento Facial/fisiologia , Medo/psicologia , Adolescente , Adulto , Tonsila do Cerebelo/cirurgia , Lobectomia Temporal Anterior/efeitos adversos , Lobectomia Temporal Anterior/psicologia , Estudos de Casos e Controles , Emoções , Epilepsia do Lobo Temporal/fisiopatologia , Epilepsia do Lobo Temporal/psicologia , Epilepsia do Lobo Temporal/cirurgia , Expressão Facial , Feminino , Lateralidade Funcional/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Neurocirúrgicos/efeitos adversos , Lobo Temporal/patologia , Lobo Temporal/cirurgia , Córtex Visual/fisiologia , Percepção Visual/fisiologia , Adulto Jovem
10.
Clin Neurophysiol ; 131(12): 2795-2803, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33137569

RESUMO

OBJECTIVE: To assess the value of caudal EEG electrodes over cheeks and neck for high-density electric source imaging (ESI) in presurgical epilepsy evaluation, and to identify the best time point during averaged interictal epileptic discharges (IEDs) for optimal ESI accuracy. METHODS: We retrospectively examined presurgical 257-channel EEG recordings of 45 patients with pharmacoresistant focal epilepsy. By stepwise removal of cheek and neck electrodes, averaged IEDs were downsampled to 219, 204, and 156 EEG channels. Additionally, ESI at the IED's half-rise was compared to other time points. The respective sources of maximum activity were compared to the resected brain area and postsurgical outcome. RESULTS: Caudal channels had disproportionately more artefacts. In 30 patients with favourable outcome, the 204-channel array yielded the most accurate results with ESI maxima < 10 mm from the resection in 67% and inside affected sublobes in 83%. Neither in temporal nor in extratemporal cases did the full 257-channel setup improve ESI accuracy. ESI was most accurate at 50% of the IED's rising phase. CONCLUSION: Information from cheeks and neck electrodes did not improve high-density ESI accuracy, probably due to higher artefact load and suboptimal biophysical modelling. SIGNIFICANCE: Very caudal EEG electrodes should be used for ESI with caution.


Assuntos
Epilepsia Resistente a Medicamentos/fisiopatologia , Eletroencefalografia/métodos , Epilepsias Parciais/fisiopatologia , Cuidados Pré-Operatórios/métodos , Adolescente , Adulto , Criança , Epilepsia Resistente a Medicamentos/diagnóstico por imagem , Epilepsia Resistente a Medicamentos/cirurgia , Eletrodos , Eletroencefalografia/instrumentação , Epilepsias Parciais/diagnóstico por imagem , Epilepsias Parciais/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cuidados Pré-Operatórios/instrumentação , Estudos Retrospectivos , Fatores de Tempo , Adulto Jovem
11.
Sci Rep ; 10(1): 11138, 2020 07 07.
Artigo em Inglês | MEDLINE | ID: mdl-32636485

RESUMO

It has been proposed that the human amygdala may not only encode the emotional value of sensory events, but more generally mediate the appraisal of their relevance for the individual's goals, including relevance for action or task-based needs. However, emotional and non-emotional/action-relevance might drive amygdala activity through distinct neural signals, and the relative timing of both kinds of responses remains undetermined. Here, we recorded intracranial event-related potentials from nine amygdalae of patients undergoing epilepsy surgery, while they performed variants of a Go/NoGo task with faces and abstract shapes, where emotion- and action-relevance were orthogonally manipulated. Our results revealed early amygdala responses to emotion facial expressions starting ~ 130 ms after stimulus-onset. Importantly, the amygdala responded to action-relevance not only with face stimuli but also with abstract shapes (squares), and these relevance effects consistently occurred in later time-windows (starting ~ 220 ms) for both faces and squares. A similar dissociation was observed in gamma activity. Furthermore, whereas emotional responses habituated over time, the action-relevance effect increased during the course of the experiment, suggesting progressive learning based on the task needs. Our results support the hypothesis that the human amygdala mediates a broader relevance appraisal function, with the processing of emotion-relevance preceding temporally that of action-relevance.


Assuntos
Tonsila do Cerebelo/fisiologia , Emoções/fisiologia , Adulto , Tonsila do Cerebelo/diagnóstico por imagem , Eletroencefalografia , Potenciais Evocados/fisiologia , Expressão Facial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neuroimagem , Estimulação Luminosa , Análise e Desempenho de Tarefas , Fatores de Tempo , Tomografia Computadorizada por Raios X , Adulto Jovem
12.
Expert Rev Med Devices ; 17(5): 405-412, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32223351

RESUMO

Introduction: Electric source imaging (ESI) refers to the estimation of the cerebral sources of electric signals recorded at the head surface using electroencephalography (EEG). Thanks to the availability of EEG systems with high numbers of electrodes and to progress in software to analyze the signals they collect, ESI can be applied to epilepsy-related pathological EEG signals like interictal spikes and seizures.Areas covered: In this narrative review, we discuss selected original research articles on the use of ESI in epilepsy patients considered for surgery. Epilepsy-related activity can be localized accurately using ESI, as established by comparison to the gold standards of intracranial EEG and seizure control following epilepsy surgery. The information brought by ESI complements successfully that of other techniques like magnetic resonance imaging and positron-emission tomography, and is clinically relevant to patient management.Expert opinion: EEG is a readily available technique to measure brain activity in real time. Given its accuracy and usefulness, ESI should become part of the routine practice of clinical neurophysiology laboratories and epilepsy centers in the presurgical management of epilepsy patients.


Assuntos
Fontes de Energia Elétrica , Epilepsia/cirurgia , Eletrodos , Eletroencefalografia , Epilepsia/diagnóstico por imagem , Humanos , Software , Resultado do Tratamento
13.
Clin Neurophysiol Pract ; 5: 16-22, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31909306

RESUMO

OBJECTIVE: In this study, we sought to determine whether visual analysis of high density EEG (HD-EEG) would provide similar localizing information comparable to electrical source imaging (ESI). METHODS: HD-EEG (256 electrodes) recordings from 20 patients suffering from unifocal, drug-resistant epilepsy (13 women, mean age 29.1 ±â€¯2.62 years, 11 with temporal lobe epilepsy) were examined. In the visual analysis condition, we identified the 5 contacts with maximal spike amplitude and determined their localization with respect to the underlying cortex. ESI was computed using the LAURA algorithm of the averaged spikes in the patient's individual MRI. We considered the localization "correct" if all 5 contacts were concordant with the resection volume underneath or if ESI was located within the resection as determined by the postoperative MRI. RESULTS: Twelve patients were postoperatively seizure-free (Engel Class IA), while the remaining eight were in class IB to IV. Visual analysis and ESI showed sensitivity of 58% and 75%, specificity of 75% and 87%, and accuracy of 65% and 80%, respectively. In 70% of cases, visual analysis and ESI provided concordant results. CONCLUSIONS: Localization of the electrodes with maximal spike amplitude provides very good estimation of the localization of the underlying source. However, ESI has a higher accuracy and adds 3D information; therefore, it should remain the tool of choice for presurgical evaluation. SIGNIFICANCE: The present study proposes the possibility to analyze HD-EEG visually, in tandem with ESI or alone, if ESI is not accessible.

14.
Front Neurol ; 10: 1250, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31849817

RESUMO

Background: Electric and magnetic source imaging methods (ESI, MSI) estimate the location in the brain of the sources generating the interictal epileptiform discharges (II-ESI, II-MSI) and the ictal activity (IC-ESI, IC-MSI). These methods provide potentially valuable clinical information in the presurgical evaluation of patients with drug-resistant focal epilepsy, evaluated for surgical therapy. In spite of the significant technical advances in this field, and the numerous papers published on clinical validation of these methods, ESI and MSI are still underutilized in most epilepsy centers performing a presurgical evaluation. Our goal was to review and summarize the published evidence on the diagnostic accuracy of interictal and ictal ESI and MSI in epilepsy surgery. Methods: We searched the literature for papers on ESI and MSI that specified the diagnostic reference standard as the site of resection and the postoperative outcome (seizure-freedom). We extracted data from the selected studies, to calculate the diagnostic accuracy measures. Results: Our search resulted in 797 studies; 48 studies fulfilled the selection criteria (25 ESI and 23 MSI studies), providing data from 1,152 operated patients (515 for II-ESI, 440 for II-MSI, 159 for IC-ESI, and 38 for IC-MSI). The sensitivity of source imaging methods was between 74 and 90% (highest for IC-ESI). The specificity of the source imaging methods was between 20 and 54% (highest for II-MSI). The overall accuracy was between 50 and 75% (highest for IC-ESI). Diagnostic Odds Ratio was between 0.8 (IC-MSI) and 4.02-7.9 (II-ESI < II-MSI < IC-ESI). Conclusions: Our systematic review and meta-analysis provides evidence for the accuracy of source imaging in presurgical evaluation of patients with drug-resistant focal epilepsy. These methods have high sensitivity (up to 90%) and diagnostic odds ratio (up to 7.9), but the specificity is lower (up to 54%). ESI and MSI should be included in the multimodal presurgical evaluation.

15.
Epilepsia ; 60(8): 1639-1649, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31329286

RESUMO

OBJECTIVE: The prediction of verbal memory decline after temporal lobe epilepsy (TLE) surgery remains difficult at an individual level. We evaluated the prognostic value of postictal memory testing in predicting the postoperative verbal memory function. METHODS: Sixty-three consecutive patients were included in the analysis who underwent TLE surgery at our center with preoperative interictal/postictal and postoperative memory testing. Verbal memory was evaluated using the Rey Auditory Verbal Learning Test (RAVLT). We used reliable change indices with 90% confidence interval (90% RCIs) to evaluate a significant postoperative memory decline. The sensitivity (Sn), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV), area under the curve (AUC), and accuracy (ACC) were calculated. The analysis was performed for all TLE patients and for the subgroup with hippocampal sclerosis (HS). RESULTS: Left-TLE patients (n = 31) had lower verbal memory scores on RAVLT than right-TLE at 3 months (57% vs 78%) and 12 months (53% vs 78%) after surgery. The 90% RCI was estimated to be a loss of 4 out of 15 items. The predictive value was Sn = 42%, Sp = 84%, PPV = 39%, NPV = 86%, AUC = 0.630, and ACC = 76% to predict a verbal memory decline in the whole group (n = 63). In HS patients (n = 41), the postictal verbal memory test had Sn = 50%, Sp = 88%, PPV = 50%, NPV = 88%, AUC = 0.689, and ACC = 81% to predict a significant postoperative decline. SIGNIFICANCE: Postictal memory is a noninvasive bedside memory test that can help predict the postoperative verbal memory decline in patients with HS with an overall accuracy of 81%.


Assuntos
Epilepsia do Lobo Temporal/cirurgia , Transtornos da Memória/etiologia , Complicações Pós-Operatórias/diagnóstico , Adulto , Epilepsia do Lobo Temporal/complicações , Feminino , Humanos , Masculino , Transtornos da Memória/diagnóstico , Prognóstico , Aprendizagem Verbal
16.
Neuropsychologia ; 131: 9-24, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31158367

RESUMO

The amygdala is crucially implicated in processing emotional information from various sensory modalities. However, there is dearth of knowledge concerning the integration and relative time-course of its responses across different channels, i.e., for auditory, visual, and audiovisual input. Functional neuroimaging data in humans point to a possible role of this region in the multimodal integration of emotional signals, but direct evidence for anatomical and temporal overlap of unisensory and multisensory-evoked responses in amygdala is still lacking. We recorded event-related potentials (ERPs) and oscillatory activity from 9 amygdalae using intracranial electroencephalography (iEEG) in patients prior to epilepsy surgery, and compared electrophysiological responses to fearful, happy, or neutral stimuli presented either in voices alone, faces alone, or voices and faces simultaneously delivered. Results showed differential amygdala responses to fearful stimuli, in comparison to neutral, reaching significance 100-200 ms post-onset for auditory, visual and audiovisual stimuli. At later latencies, ∼400 ms post-onset, amygdala response to audiovisual information was also amplified in comparison to auditory or visual stimuli alone. Importantly, however, we found no evidence for either super- or subadditivity effects in any of the bimodal responses. These results suggest, first, that emotion processing in amygdala occurs at globally similar early stages of perceptual processing for auditory, visual, and audiovisual inputs; second, that overall larger responses to multisensory information occur at later stages only; and third, that the underlying mechanisms of this multisensory gain may reflect a purely additive response to concomitant visual and auditory inputs. Our findings provide novel insights on emotion processing across the sensory pathways, and their convergence within the limbic system.


Assuntos
Tonsila do Cerebelo/fisiologia , Emoções/fisiologia , Potenciais Evocados/fisiologia , Estimulação Acústica , Adolescente , Adulto , Percepção Auditiva/fisiologia , Eletrocorticografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estimulação Luminosa , Tempo de Reação/fisiologia , Percepção Visual/fisiologia , Adulto Jovem
17.
Biol Psychol ; 145: 211-223, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31129312

RESUMO

How emotions unfold through time in the brain, and how fast they can be regulated by voluntary control, remain unresolved. Psychological accounts of emotion regulation posit cognitive reappraisal mechanisms may alter early emotion generative processes directly, whereas suppression impacts only later processing stages, after emotion has arisen. However, to date, there is no neurophysiological data concerning the precise latency of emotion regulation effects on the amygdala, a major emotion processing relay in the brain. Here we record amygdala activity from six patients undergoing surgery for pharmaco-resistant epilepsy during both reappraisal and suppression. We find that emotion reappraisal strategy, but not suppression, modulates early neural responses to emotional scenes during an extended period of time, starting 130 ms post-stimulus onset. Further, reappraisal produced earlier impact on amygdala responses to positive compared to negative scenes. Our results provide the first neurophysiological support for theoretical accounts of emotion regulation that postulate an early modulation of emotion generative processes by reappraisal.


Assuntos
Tonsila do Cerebelo/fisiologia , Emoções/fisiologia , Adulto , Tonsila do Cerebelo/diagnóstico por imagem , Encéfalo/diagnóstico por imagem , Encéfalo/fisiologia , Mapeamento Encefálico , Epilepsia/diagnóstico por imagem , Epilepsia/fisiopatologia , Epilepsia/psicologia , Feminino , Humanos , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade
18.
Clin Neurophysiol ; 130(5): 845-855, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30824202

RESUMO

OBJECTIVE: Interictal high resolution (HR-) electric source imaging (ESI) and magnetic source imaging (MSI) are non-invasive tools to aid epileptogenic zone localization in epilepsy surgery candidates. We carried out a systematic review on the diagnostic accuracy and quality of evidence of these modalities. METHODS: Embase, Pubmed and the Cochrane database were searched on 13 February 2017. Diagnostic accuracy studies taking post-surgical seizure outcome as reference standard were selected. Quality appraisal was based on the QUADAS-2 framework. RESULTS: Eleven studies were included: eight MSI (n = 267), three HR-ESI (n = 127) studies. None was free from bias. This mostly involved: selection of operated patients only, interference of source imaging with surgical decision, and exclusion of indeterminate results. Summary sensitivity and specificity estimates were 82% (95% CI: 75-88%) and 53% (95% CI: 37-68%) for overall source imaging, with no statistical difference between MSI and HR-ESI. Specificity is higher when partially concordant results were included as non-concordant (p < 0.05). Inclusion of indeterminate test results as non-concordant lowered sensitivity (p < 0.05). CONCLUSIONS: Source imaging has a relatively high sensitivity but low specificity for identification of the epileptogenic zone. SIGNIFICANCE: We need higher quality studies allowing unbiased test evaluation to determine the added value and diagnostic accuracy of source imaging in the presurgical workup of refractory focal epilepsy.


Assuntos
Mapeamento Encefálico/métodos , Eletroencefalografia , Epilepsia/cirurgia , Imageamento por Ressonância Magnética , Magnetoencefalografia , Epilepsia/diagnóstico por imagem , Epilepsia/fisiopatologia , Humanos , Sensibilidade e Especificidade
19.
J Neurosurg Sci ; 63(1): 19-29, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27175620

RESUMO

BACKGROUND: The traditional approach to patients suffering from cervical spondylotic myelopathy (CSM) consists of mere assessment of radiological standard magnetic resonance (MR) images and evaluation of surgical indication, depending on clinical symptoms and degree of radiological stenosis. Identification of prognostic factors for surgery remains difficult. Surgery is thought to be able to stop the disease progression, while significant improvements of neurological symptoms are not predictable. METHODS: Authors present a modern approach to patients with CSM, that is comprehensive of clinical, electrophysiological and radiological findings, and that has been developed by a multidisciplinary team of experts (neurosurgeons, neurologists, neuroradiologists). Authors tried to identify the good responders to surgery, as those who really improved symptoms, by performing an integration of these data. This approach has been used in 11 consecutive patients suffering from and operated for CSM at our Institution. The multidisciplinary protocol included the complementary use of electrophysiological (motor and somatosensory evoked potentials), radiological (magnetic resonance, cervical plain and dynamic x-rays), and clinical (modified Japanese Orthopedic Association [mJOA] and Neck Disability Index [NDI] scores, Hirabayashi Recovery Ratio) values. These data were obtained at the preoperative period, and at 3 and 12 months follow-up. We defined as "good responders" those patients having had an improvement of the Hirabayashi Recovery Ratio of 50% and of the NDI of 30%. RESULTS: The mean preoperative mJOA was 12.79 (range 3-17), while the mean mJOA at 3 and 12 months was, respectively, 14.71 and 13.43. However, only the improvement at 3 months was statistically significant, while improvements from the preoperative assessment to 12 months and from 3 to 12 months were not significant. The mean preoperative NDI was 33.57%, while it was 32.43% and 24.36% at 3 and 12 months, respectively. None of these improvements was significant. Concerning response to surgery, we observed 7/11 (63.3%) good responders according to the Hirabayashi Recovery Ratio, and 6/11 (54.5%) good responders according to NDI results. CONCLUSIONS: A modern multidisciplinary approach to patients with CSM is mandatory to investigate the different aspects of the disease. Decompressive surgery was able, in our series, to improve or stabilize clinical symptoms. Further studies are necessary to allow for a proper selection of patients by cumulative analysis of multidisciplinary findings.


Assuntos
Descompressão Cirúrgica/métodos , Procedimentos Neurocirúrgicos/métodos , Procedimentos Ortopédicos/métodos , Avaliação de Processos e Resultados em Cuidados de Saúde , Doenças da Medula Espinal/diagnóstico , Doenças da Medula Espinal/cirurgia , Espondilose/diagnóstico , Espondilose/cirurgia , Adulto , Idoso , Vértebras Cervicais , Imagem de Tensor de Difusão , Potenciais Somatossensoriais Evocados/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
20.
Neurology ; 91(2): e96-e106, 2018 07 10.
Artigo em Inglês | MEDLINE | ID: mdl-29898967

RESUMO

OBJECTIVE: Resective surgery is effective in treating drug-resistant focal epilepsy, but it remains unclear whether improved diagnostics influence postsurgical outcomes. Here, we compared practice and outcomes over 2 periods 15 years apart. METHODS: Sixteen European centers retrospectively identified 2 cohorts of children and adults who underwent epilepsy surgery in the period of 1997 to 1998 (n = 562) or 2012 to 2013 (n = 736). Data collected included patient (sex, age) and disease (duration, localization and diagnosis) characteristics, type of surgery, histopathology, Engel postsurgical outcome, and complications, as well as imaging and electrophysiologic tests performed for each case. Postsurgical outcome predictors were included in a multivariate logistic regression to assess the strength of date of surgery as an independent predictor. RESULTS: Over time, the number of operated cases per center increased from a median of 31 to 50 per 2-year period (p = 0.02). Mean disease duration at surgery decreased by 5.2 years (p < 0.001). Overall seizure freedom (Engel class 1) increased from 66.7% to 70.9% (adjusted p = 0.04), despite an increase in complex surgeries (extratemporal and/or MRI negative). Surgeries performed during the later period were 1.34 times (adjusted odds ratio; 95% confidence interval 1.02-1.77) more likely to yield a favorable outcome (Engel class I) than earlier surgeries, and improvement was more marked in extratemporal and MRI-negative temporal epilepsy. The rate of persistent neurologic complications remained stable (4.6%-5.3%, p = 0.7). CONCLUSION: Improvements in European epilepsy surgery over time are modest but significant, including higher surgical volume, shorter disease duration, and improved postsurgical seizure outcomes. Early referral for evaluation is required to continue on this encouraging trend.


Assuntos
Epilepsia Resistente a Medicamentos/epidemiologia , Procedimentos Neurocirúrgicos/estatística & dados numéricos , Complicações Pós-Operatórias/epidemiologia , Resultado do Tratamento , Adolescente , Adulto , Criança , Pré-Escolar , Epilepsia Resistente a Medicamentos/cirurgia , Fenômenos Eletrofisiológicos , Europa (Continente)/epidemiologia , Feminino , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Neuroimagem , Estudos Retrospectivos , Fatores de Tempo , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA