Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Ir Vet J ; 74(1): 16, 2021 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-34134768

RESUMO

BACKGROUND: As part of clinical wound assessment in bovine surgery, discrepancies in skin temperature are evaluated by placing the back of the hand on the area to be examined. Generally, an increased skin temperature at the wound site for a prolonged period is considered as an indicator of impaired wound healing. The aim of this study was to verify the reliability of palpation under bovine practice conditions using laparotomy as an example. Fourteen cows (German Holstein) with a left displacement of the abomasum (LDA) without other severe concurrent diseases were examined preoperatively and once daily for ten days after surgery. The skin temperature of the wound site in the right flank was assessed by palpation, followed by thermographic evaluation using an infrared camera after a 45-min acclimatisation period, under standardised conditions in a closed examination room daily for 10 days. RESULTS: All the incisions healed without clinical detectable perturbances. The ambient temperature range during the study period was 7.8 - 24.1 °C. Two groups were retrospectively defined according to the ambient temperature: high ambient temperature (HT group; median: 20.2 °C 25/75 quartile: 18.5 °C / 21.7 °C; n = 6) and low ambient temperature (LT group; 10.8 °C; 9.4 °C / 12.8 °C; n = 8). The temperature differences (Δϑ) between the mean skin temperature of the wound site and a defined reference area cranial to the wound were assessed. A significant negative correlation was found between the ambient temperature (ϑAmb) and Δϑ (r=-0.51; P < 0.001). The Δϑ was postoperatively higher in the cows in the LT group (median of the individual animals 0.8-2.5 °C) than in the HT group (0.1-0.5 °C; P < 0.05). In contrast to the thermographic findings, manual palpation rarely detected local hyperthermia (> 1 °C) at the wound site (sensitivity 0.20; specificity 0.96). CONCLUSIONS: The infrared thermography provides a more reliable assessment of temperature changes at the wound site in comparison to manual palpation. The ambient temperature markedly affects the extent of local hyperthermia at the wound site.

2.
Res Vet Sci ; 136: 430-443, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33812286

RESUMO

Gait analysis as subjective visual assessment forms the foundation of the veterinarian's lameness examination. Pelvic limb lameness is frequently seen in dogs and the stifle joint with its cruciate ligaments, is a main cause of lameness due to cruciate ligament deficiency. In this study, we developed an open-source three-dimensional musculoskeletal pelvic limb model of a 30 kg Labrador Retriever including cruciate ligaments, simulating the gait cycle of the walking movement with the open-source programs NMSBuilder (Institutio Ortopedico Rizzoli, Bologna, Italy) and OpenSim (National Center for Simulation in Rehabilitation Research (NCSRR), Stanford, CA, USA). The computer model generated muscle activations based on motion data. The computed activations were similar to experimental electromyogram data. Highest joint torque was in extension/flexion in the stifle joint at 54 Nm at 14% of the gait cycle with cruciate ligaments. Highest stifle joint reaction force was 408 N at 16% of the gait cycle and was reduced after adding cruciate ligaments. Especially the cranial cruciate ligament loads up to 102 N (34% body weight). Cranial cruciate ligament forces increase with stifle extension and decrease with stifle flexion. On the contrary, the caudal cruciate ligament loads up to 27 N (9% body weight) during the swing phase with a flexed stifle joint. The model was validated with electromyogram data. The model's predictions are plausible because joint torques and forces match the applied ground reaction forces in curve progression and in timing. This model forms a basis for further investigations into stifle surgery after cruciate ligament deficiency.


Assuntos
Ligamento Cruzado Anterior/anatomia & histologia , Simulação por Computador , Cães/anatomia & histologia , Modelos Anatômicos , Ossos Pélvicos/anatomia & histologia , Joelho de Quadrúpedes/anatomia & histologia , Animais , Fenômenos Biomecânicos , Marcha , Membro Posterior/anatomia & histologia , Itália , Masculino , Rotação
3.
Acta Vet Scand ; 60(1): 72, 2018 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-30400988

RESUMO

BACKGROUND: Nephropathies are among the most common diseases in dogs. Regular examination of the kidney function plays an important role for an adequate treatment scheme. The determination of the glomerular filtration rate (GFR) is seen as the gold standard in assessing the kidney status. Most of the tests have the disadvantage that only the complete glomerular filtration rate of both kidneys can be assessed and not the single kidney glomerular filtration rate. Imaging examination techniques like dynamic contrast-enhanced magnetic resonance imaging have the potential to evaluate the single kidney GFR. There are studies in human medicine describing the determination of the single kidney GFR using this technique. To our knowledge there are no such studies for dogs. RESULTS: An exponential fit was found to describe the functional interrelation between signal intensity and contrast medium concentrations. The changes of contrast medium concentrations during the contrast medium bolus propagation were calculated. The extreme values of contrast medium concentrations in the kidneys were reached at nearly the same time in every individual dog (1st maximum aorta 8.5 s, 1st maximum in both kidneys after about 14.5 s; maximum concentration values varied between 17 and 125 µmol/mL in the aorta and between 4 and 15 µmol/mL in the kidneys). The glomerular filtration rate was calculated from the concentration changes of the contrast medium using a modified Rutland-Patlak plot technique. The GFR was 12.7 ± 2.9 mL/min m2 BS for the left kidney and 12.0 ± 2.2 mL/min/m2 BS for the right kidney. The mean values of the coefficient of determination of the regression lines were averagely 0.91 ± 0.08. CONCLUSIONS: The propagation of contrast medium bolus could be depicted well. The contrast medium proceeded in a similar manner for every individual dog. Additionally, the evaluation of the single kidney function of the individual dogs is possible with this method. A standardized examination procedure would be recommended in order to minimize influencing parameters.


Assuntos
Taxa de Filtração Glomerular/veterinária , Nefropatias/veterinária , Rim/diagnóstico por imagem , Imageamento por Ressonância Magnética , Animais , Meios de Contraste , Cães , Nefropatias/diagnóstico por imagem , Análise de Regressão
4.
Materials (Basel) ; 11(1)2017 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-29267239

RESUMO

Metallic biomaterials are widely used in maxillofacial surgery. While titanium is presumed to be the gold standard, magnesium-based implants are a current topic of interest and investigation due to their biocompatible, osteoconductive and degradable properties. This study investigates the effects of poly-ε-caprolactone-coated and previtalised magnesium implants on osteointegration within murine calvarial bone defects: After setting a 3 mm × 3 mm defect into the calvaria of 40 BALB/c mice the animals were treated with poly-ε-caprolactone-coated porous magnesium implants (without previtalisation or previtalised with either osteoblasts or adipose derived mesenchymal stem cells), porous Ti6Al4V implants or without any implant. To evaluate bone formation and implant degradation, micro-computertomographic scans were performed at day 0, 28, 56 and 84 after surgery. Additionally, histological thin sections were prepared and evaluated histomorphometrically. The outcomes revealed no significant differences within the differently treated groups regarding bone formation and the amount of osteoid. While the implant degradation resulted in implant shifting, both implant geometry and previtalisation appeared to have positive effects on vascularisation. Although adjustments in degradation behaviour and implant fixation are indicated, this study still considers magnesium as a promising alternative to titanium-based implants in maxillofacial surgery in future.

5.
BMC Vet Res ; 10: 199, 2014 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-25260642

RESUMO

BACKGROUND: Actinobacillus pleuropneumoniae (A.pp.) is the causative agent of porcine pleuropneumonia leading to high economic losses in the pig industry. Infrared thermography (IRT) of the thorax might offer a new method to select swine with lung alterations for further diagnostics. In this study 50 german landrace pigs were infected with A.pp. in an established model for respiratory tract disease, while 10 healthy pigs served as control animals. To avoid drift errors during IR measurements absolute skin temperatures and temperature differences between a thoracal and an abdominal region were assessed for its diagnostic validity. RESULTS: IRT findings during the course of experimental A.pp.-infection were verified by computed tomography (CT) before and on days 4 and 21 after infection. Significant correlations were found between clinical scores, CT score and lung lesion score. Ambient temperature, body temperature and abdominal surface temperature were factors influencing the skin surface temperature of the thorax. On day 4 but not on day 21 after infection the right thoracal temperature was significantly higher and the difference between a thoracal region in the height of the left 10th vertebra and an abdominal region was significantly lower in infected pigs than in control pigs. At a cut off of 28°C of right thoracal temperature the specificity of the method was 100% (CI 95%: 69-100%) and the sensitivity 66% (CI 95%: 51-79%). At a cut off of 2°C temperature difference between thoracal and abdominal region on the left body site the specificity of the method was 100% (CI 95%: 69-100%) and the sensitivity 32% (CI 95%: 19-47%) with all control pigs detected negative. Orientation for lung biopsy by IRT resulted in 100% specificity and sensitivity (CI 95%: 69-100%) of bacteriological examination of tissue samples during the acute stage of infection. CONCLUSION: IRT might be a valuable tool for the detection of inflammatory lung alterations in pigs, especially during the acute stage of infection and if ambient temperatures are constant during individual measurements. External and internal factors interfere with this method, so that its application in the field might be restricted to a selection of pigs for further diagnostic with adequate specificity.


Assuntos
Infecções por Actinobacillus/veterinária , Actinobacillus pleuropneumoniae , Pulmão/patologia , Doenças dos Suínos/patologia , Termografia/veterinária , Infecções por Actinobacillus/microbiologia , Infecções por Actinobacillus/patologia , Animais , Biópsia , Temperatura Corporal/fisiologia , Estudos de Casos e Controles , Suínos , Doenças dos Suínos/microbiologia , Termografia/métodos
6.
Berl Munch Tierarztl Wochenschr ; 121(5-6): 228-38, 2008.
Artigo em Alemão | MEDLINE | ID: mdl-18557527

RESUMO

The knowledge of the radiation exposure of the staff involved in X-ray examinations is one precondition for an optimisation of radiation protection. Hence the radiation exposure of the staff during X-ray examinations of dogs and cats was investigated in the Clinic for Small Animals. The study includes at least ten measurements for each of thirteen X-ray examinations of a dog and four of a cat. The equivalent doses of eye lens, thyroid, chest, hands, gonads, and lower leg were measured using TLD (LiF:Mg,Cu,P). The maximum values of 44.3 and 48.3 microSv were measured on the eye lens and the thyroid, respectively. The median and mean values of the equivalent doses on the seven measuring positions with the exception of eye lens (6.0 microSv) are lower than 5 microSv per radiograph. More than 95% of the equivalent doses on chest, hands, gonads, and lower leg are smaller than 2 microSv. Particularly eye lenses and thyroid are exposed to measurable doses. Altogether the radiation exposure of the staff is relatively low. Hence a manual fixation of animals is justifiable if the fundamental rules of radiation protection are observed.


Assuntos
Doenças do Gato/diagnóstico por imagem , Doenças do Cão/diagnóstico por imagem , Exposição Ocupacional , Radiografia/veterinária , Animais , Gatos , Cães , Relação Dose-Resposta à Radiação , Humanos , Proteção Radiológica , Radiografia/efeitos adversos , Radiografia/normas , Dosimetria Termoluminescente
7.
Berl Munch Tierarztl Wochenschr ; 120(5-6): 251-9, 2007.
Artigo em Alemão | MEDLINE | ID: mdl-17555048

RESUMO

In Germany pet owners are present during X-ray examinations of dogs and cats. Due to a change in the German X-ray Ordinance and the directive "Radiation Protection in Veterinary Medicine" it is necessary to determine the body dose of the pet owners. This study in the Clinic for Small Animals includes at least ten measurements for each of thirteen X-ray examinations of a dog and four of a cat. The equivalent doses of eye lens, thyroid, chest, hands, gonads, and lower leg were measured using TLD (LiF:Mg,Cu,P). The maximum value of 52 microSv was measured on the right hand. The 99 % -quantiles amount to 13 microSv for eye lens, 9 microSv for thyroid, 2.3 microSv for chest (under lead apron), 14 microSv for both hands, 2.1 microSv for gonads (under lead apron), and 2.0 microSv for lower leg. In every case the median and mean values at the seven measuring positions are lower than 2.5 microSv per radiograph. In view of the constant measured equivalent doses under the lead apron of less than 5 microSv for the trunk and gonads per X-ray examination the measurement of the personal dose of the pet owner during every X-ray examination of small animals is not justified. Alternatively, with reference to up-to-date measurements and the presented paper a certificate of exemption from the dose determination for pet owners could be applied for from the local authority.


Assuntos
Doenças do Gato/diagnóstico por imagem , Doenças do Cão/diagnóstico por imagem , Radiografia/veterinária , Dosimetria Termoluminescente , Animais , Gatos , Cães , Humanos , Proteção Radiológica , Radiografia/normas , Dosimetria Termoluminescente/estatística & dados numéricos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA