Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Clin Med ; 13(3)2024 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-38337514

RESUMO

(1) Background: There is controversy regarding stent placement for unresectable malignant hilar biliary obstruction (UMHBO). We mainly use the partial stent-in-stent (PSIS) method with an uncovered self-expandable metallic stent (UCSEMS) based on the drainage area and patency period. In this study, we investigated the usefulness and safety of the PSIS method. (2) Methods: In total, 59 patients who underwent the PSIS method for UMHBO at our hospital were included in the study. The technical success rate, clinical success rate, time to recurrent biliary obstruction (TRBO) and overall survival (OS) from the first placement, factors affecting TRBO and OS, and early complications within 30 days after the procedure were evaluated retrospectively. (3) Results: The technical and clinical success rates were 100% and 96.6%, respectively, with a TRBO of 121 days [95% confidence interval: 82-231] and an OS of 194 days [95% confidence interval: 113-305] after the first placement. Early complications occurred in nine patients (15.3%), including five cases of cholangitis, three cases of pancreatitis, and one case of cholecystitis. (4) Conclusions: The PSIS method for UMHBO is safe and useful with high technical and clinical success rates.

2.
Diagnostics (Basel) ; 13(9)2023 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-37174928

RESUMO

Pathological examination by endoscopic ultrasound-fine needle aspiration is not possible in approximately 10% of pancreatic tumor cases. Pancreatic juice cytology (PJC) is considered an alternative diagnostic method. However, its diagnostic capability is insufficient, and PJC has been repeatedly redevised. Serial pancreatic juice aspiration cytological examination (SPACE) and secretin-loaded PJC (S-PJC) have been recently introduced as alternative diagnostic methods. This study aimed to determine the diagnostic capacity and safety of SPACE and S-PJC using a propensity score-matched analysis. The sensitivity, specificity, and accuracy were 75.0%, 100%, and 92.3% for S-PJC, respectively, and 71.4%, 100%, and 92.3% for SPACE, respectively, meaning that there was no significant difference between the groups. Four patients (15.4%) each in the S-PJC and SPACE groups experienced complications, including postendoscopic retrograde cholangiopancreatography, pancreatitis, and cholangitis. Overall, there was no difference in efficacy and safety between the SPACE and S-PJC groups.

3.
J Clin Med ; 12(6)2023 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-36983143

RESUMO

Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is an essential endoscopic tissue sampling method for diagnosing pancreatobiliary diseases; however, determining the presence of target specimens mixed in the blood by conventional observation is challenging due to the small size of the obtained sample. This study investigated the usefulness of a target sample check illuminator (TSCI) that emits a specific wavelength of light to determine the presence of target specimens. Twenty-seven patients who underwent EUS-FNA at our hospital were included. Conventional white light observation was performed for the collected samples, followed by TSCI; six people evaluated the presence of the target specimen on a 5-point scale. The target specimen discrimination score using TSCI (median: 5) was significantly higher than that using conventional white light observation (median: 1) (p < 0.001). No significant difference was observed in the discrimination score between the evaluator (novice vs. expert, p = 0.162) and puncture needle (22G vs. 25G, p = 0.196). The discriminability of TSCI in the samples obtained using EUS-FNA was significantly higher than that of conventional observation. TSCI does not depend on the evaluator or puncture needle for the identification of the target specimen; hence, it can provide a good pathological specimen and may contribute to the improvement of the diagnostic ability.

4.
Int J Cardiol Heart Vasc ; 43: 101147, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36389267

RESUMO

Background: Exercise therapy for cardiovascular disease (CVD) is mainly evaluated based on the heart rate (HR) or Borg scale. However, these indices can be unreliable depending on the patient's medication or their subjective decisions; thus, alternative methods are required for easier and safer implementation of aerobic exercise. Here, we examined whether real-time analysis of HR variability (HRV) can help maintain exercise intensity at the ventilatory threshold (VT) during exercise. Methods: Twenty-eight patients with CVD treated at Keio University Hospital between August 2018 and March 2020 were enrolled. Initially, oxygen uptake (VO2) and HR at the VT were determined using the cardiopulmonary exercise test. Patients then performed aerobic exercise on a stationary bicycle for 30 min while a parameter of HRV, the high-frequency (HF) component, was monitored in real time using an electrocardiograph. The work rate during exercise was adjusted every 2 min to maintain the HF range between 5 and 10. The VO2 and HR values, recorded every 2 min during exercise, were compared with those at VT. The Bland-Altman method was used to confirm similarity. Results: VO2 and HR during exercise were closely correlated with those at VT (e.g., 19 min after exercise initiation; VO2: r = 0.647, HR: r = 0.534). The Bland-Altman plot revealed no bias between the mean values (e.g., 19 min; VO2: -0.22 mL/kg/min; HR: -0.07/min). Conclusion: Real-time HRV analysis with electrocardiograph alone during exercise can provide continuous and non-invasive exercise intensity measurements at VT, promoting safer and effective exercise strategies.

5.
JACC Clin Electrophysiol ; 8(10): 1289-1300, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36266006

RESUMO

BACKGROUND: Adenosine-sensitive re-entrant atrial tachycardia (AT) originating from near the atrioventricular (AV) node or AV annulus resembles other supraventricular tachycardias (SVTs), and the differential diagnosis is sometimes challenging. OBJECTIVES: This study sought to develop a novel technique to distinguish adenosine-sensitive re-entrant AT from AV nodal re-entrant tachycardia (AVNRT) and orthodromic reciprocating tachycardia (ORT). METHODS: The study retrospectively studied 117 re-entrant SVTs that were successfully entrained by atrial overdrive pacing (AOP) (27 adenosine-sensitive re-entrant ATs, 63 AVNRTs, 27 ORTs). If the second atrial electrogram after AOP (A2) at the earliest atrial activation site (EAAS) accelerated to the pacing cycle length, the EAAS was considered orthodromically activated. Then, we compared the sequence of A2 and the last entrained His bundle (H∗) and QRS complex (V∗). The study hypothesized that the last entrained impulse would activate the EAAS before it enters the AV node, His bundle, and ventricle during AT (A2-H∗-V∗) but would activate the EAAS after the His bundle activation during AVNRT and ORT (H∗-V∗-A2 or H∗-A2-V∗). RESULTS: Orthodromic EAAS activation was documented during AOP in 84 SVTs (72%) when performing AOP from sites proximal to the entrance of SVTs. A2-H∗-V∗ responses were observed in 21 of 25 ATs, but were never for AVNRTs or ORTs. All ORTs and fast-slow AVNRTs had H∗-V∗-A2 responses. Eleven of 21 slow-fast AVNRTs had H∗-A2-V∗ responses. The sensitivity, specificity, and positive and negative predictive values of the A2-H∗-V∗ response for diagnosing AT were 84%, 100%, 100%, and 94%, respectively. CONCLUSIONS: The last entrainment sequence was useful for differentiating ATs with diagnostic difficulties.


Assuntos
Taquicardia Reciprocante , Taquicardia Supraventricular , Humanos , Estudos Retrospectivos , Estimulação Cardíaca Artificial/métodos , Eletrocardiografia/métodos , Adenosina
6.
Biomedicines ; 10(9)2022 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-36140322

RESUMO

An MSM/Ms strain was established using Japanese wild mice, which exhibit resistance to several phenotypes associated with aging, such as obesity, inflammation, and tumorigenesis, compared to common inbred mouse strains. MSM/Ms strain is resistant to age-related hearing loss, and their auditory abilities are sustained for long durations. The age-related hearing loss 3 (ahl3) locus contributes to age-related hearing in MSM/Ms strain. We generated ahl3 congenic strains by transferring a genomic region on chromosome 17 from MSM/Ms mice into C57BL/6J mice. Although C57BL/6J mice develop age-related hearing loss because of the ahl allele of the cadherin 23 gene, the development of middle- to high-frequency hearing loss was significantly delayed in an ahl3 congenic strain. Moreover, the novel age-related hearing loss 10 (ahl10) locus associated with age-related hearing resistance in MSM/Ms strain was mapped to chromosome 12. Although the resistance effects in ahl10 congenic strain were slightly weaker than those in ahl3 congenic strain, slow progression of age-related hearing loss was confirmed in ahl10 congenic strain despite harboring the ahl allele of cadherin 23. These results suggest that causative genes and polymorphisms of the ahl3 and ahl10 loci are important targets for the prevention and treatment of age-related hearing loss.

7.
J Med Chem ; 65(4): 2926-2939, 2022 02 24.
Artigo em Inglês | MEDLINE | ID: mdl-34313428

RESUMO

The novel coronavirus, SARS-CoV-2, has been identified as the causative agent for the current coronavirus disease (COVID-19) pandemic. 3CL protease (3CLpro) plays a pivotal role in the processing of viral polyproteins. We report peptidomimetic compounds with a unique benzothiazolyl ketone as a warhead group, which display potent activity against SARS-CoV-2 3CLpro. The most potent inhibitor YH-53 can strongly block the SARS-CoV-2 replication. X-ray structural analysis revealed that YH-53 establishes multiple hydrogen bond interactions with backbone amino acids and a covalent bond with the active site of 3CLpro. Further results from computational and experimental studies, including an in vitro absorption, distribution, metabolism, and excretion profile, in vivo pharmacokinetics, and metabolic analysis of YH-53 suggest that it has a high potential as a lead candidate to compete with COVID-19.


Assuntos
Antivirais/farmacologia , Proteases 3C de Coronavírus/antagonistas & inibidores , Inibidores de Cisteína Proteinase/farmacologia , Cetonas/farmacologia , Peptidomiméticos/farmacologia , SARS-CoV-2/efeitos dos fármacos , Animais , Antivirais/síntese química , Antivirais/química , COVID-19/metabolismo , Chlorocebus aethiops , Proteases 3C de Coronavírus/isolamento & purificação , Proteases 3C de Coronavírus/metabolismo , Inibidores de Cisteína Proteinase/síntese química , Inibidores de Cisteína Proteinase/química , Humanos , Cetonas/química , Masculino , Testes de Sensibilidade Microbiana , Microssomos Hepáticos/química , Microssomos Hepáticos/metabolismo , Modelos Moleculares , Conformação Molecular , Peptidomiméticos/síntese química , Peptidomiméticos/química , Ratos , Ratos Wistar , SARS-CoV-2/enzimologia , Células Vero , Tratamento Farmacológico da COVID-19
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA