Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Cureus ; 13(8): e16873, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34513448

RESUMO

A 63-year-old male presented with a prolonged history of bilateral ear discharge, otalgia, and hearing loss. The patient required a significant number of investigations prior to obtaining a diagnosis. Subsequent investigations identified keratoacanthoma affecting the external ear canal (EAC). There has been no case report of keratoacanthoma within the EAC till now. The only risk factor identified for the development of keratoacanthoma, in this case, was the frequent use of earbuds and subsequent long-term trauma associated with a retained bud. The histology of keratoacanthoma is difficult to differentiate from that of squamous cell carcinoma but this is essential for the ear, nose, throat (ENT) multi-disciplinary team.

2.
Laryngoscope ; 130(5): 1282-1286, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31566754

RESUMO

OBJECTIVE: This study evaluates the current evidence base for total endoscopic stapes surgery, specifically to establish current efficacy and safety of the technique within clinical practice. DATA SOURCES: A systematic review of the literature on endoscopic stapes surgery was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis checklist. A comprehensive search of PubMed, Embase, and the Cochrane Central Register of Controlled Trials database for relevant publications for all available dates with appropriate Medical Subject Headings search criteria in January 2018. STUDY SELECTION: Out of the 160 articles identified in the search, 14 met the inclusion criteria for further analysis. Four of these were level III and 10 level IV evidence. DATA EXTRACTION: A pooled patient population of 314 individuals was analyzed. DATA SYNTHESIS: Documented postoperative air bone gap closure to within 20 dB was found in 95.3% of individuals (285 patients). Facial nerve palsy (temporary) occurred in three patients (0.6%), with all recovering. No total sensorineural hearing losses were recorded, but two moderate sensorineural hearing losses occurred (0.6%). Perilymph fistula was noted on four occasions (1.3%). Chorda tympani trauma was documented in 3.5% of cases, with taste disturbance documented in 13 patients (5%). CONCLUSIONS: Our pooled analysis uses the current published evidence to establish the complication rate and audiological outcome for the endoscopic approach to stapes surgery. These outcomes are comparable to those documented in traditional use of the microscope for stapedectomy. Laryngoscope, 130:1282-1286, 2020.


Assuntos
Endoscopia , Cirurgia do Estribo/métodos , Testes Auditivos , Humanos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Cirurgia do Estribo/efeitos adversos , Resultado do Tratamento
3.
Otol Neurotol ; 35(8): 1338-44, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24809280

RESUMO

OBJECTIVE: To assess the utility of cone-beam computed tomography (CBCT) imaging in the estimation of cochlear implant (CI) electrode position in implanted temporal bones. STUDY DESIGN: Eight fresh frozen temporal bones were mounted and oriented as for standard surgery and were implanted with Cochlear Slim-Straight (SS) or Contour Advance electrode arrays by 2 CI surgeons. The bones were then imaged using an Accuitomo F170 CBCT scanner (isometric 250 µm voxel size) and were then processed for histologic sectioning (500 µm sections). MAIN OUTCOME MEASURES: The CBCT images and the histologic micrographs (providing the "gold standard") were examined independently by several observers who assessed the scalar position (tympani or vestibuli) of each electrode in each temporal bone specimen. RESULTS: Examination of the histologic micrographs confirmed that all electrodes were positioned within the scala tympani in all 8 bones. Similar judgments were made by the observers rating the CBCT images, except that one of the 2 observers estimated some of the apical electrodes to be located in the scala vestibuli in two of the bones implanted with the SS electrode. CONCLUSION: Cone-beam CT imaging is able to provide a good indication of the scalar position of implanted electrodes, although estimation may be slightly less reliable for apical electrodes and for straight electrode designs. Additional advantages of using CBCT for this purpose are shorter acquisition time and reduction of radiation dose as compared with conventional CT.


Assuntos
Implante Coclear/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Osso Temporal/diagnóstico por imagem , Osso Temporal/cirurgia , Cadáver , Cóclea/cirurgia , Implantes Cocleares , Humanos
4.
Cochlear Implants Int ; 15(6): 333-6, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24840806

RESUMO

OBJECTIVE AND IMPORTANCE: Patients who have undergone solid organ transplantation and continuing immunosuppressant medication are at a higher risk of wound problems and infections following cochlear implantation. This risk is theoretically even further increased in multi-organ transplant recipients due to the increased doses of immunosuppressive medications that these patients are administered. CLINICAL PRESENTATION AND INTERVENTION: Here, we present the first reported case of successful cochlear implantation in a patient who had previously undergone successful combined liver and kidney transplant. She had no significant complications from the surgery and had good audiological outcomes 3 months post-operatively. CONCLUSION: As we continue our advances in the use of cochlear implant technology, our report adds to the growing evidence of its benefits in transplant recipients. However, there are important pre- and peri-operative considerations in this group of patients which can improve safety and outcome.


Assuntos
Implante Coclear , Transplante de Rim , Transplante de Fígado , Idoso , Terapia Combinada , Feminino , Perda Auditiva/complicações , Perda Auditiva/terapia , Humanos , Imunossupressores/uso terapêutico , Doenças Renais Policísticas/complicações , Doenças Renais Policísticas/terapia , Percepção da Fala , População Branca
5.
Cochlear Implants Int ; 13(4): 193-6, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22449409

RESUMO

INTRODUCTION: Cochlear implant recipients are known to be at an increased risk of meningitis. It is routine practice to check that pneumococcal vaccinations have been received prior to surgery. Recent changes in United Kingdom national guidelines mean that children who were previously thought to be fully immunized may in fact not be optimally protected. We present a simple, robust audit tool that can be used in both primary care and tertiary centres to identify those children at risk. METHODS: The pneumococcal immunization status of 63 paediatric cochlear implant recipients was assessed using a unique and comprehensive flowchart-style audit tool. The data collected included age at implantation, details of previous immunizations, and whether or not further vaccinations were required. RESULTS: Fifty-four per cent of children were not optimally immunized prior to implantation. Seventy per cent of children required further vaccinations following surgery. The commonest reason for an incomplete immunization history was failure to administer the 23-valent vaccine after the second birthday. CONCLUSION: The pneumococcal immunization schedule for high-risk children is complicated and nationally available guidance can be difficult to interpret. There are multiple types of vaccines and their use is not standardized across the UK. Cochlear implant programmes may find that a large proportion of their patients are in fact not optimally vaccinated, particularly in light of recent changes in the national guidelines. Our audit tool allows health professionals, in both primary care and implant centres, to accurately assess the status and immunization requirements for both new and old patients.


Assuntos
Implante Coclear/normas , Meningite Pneumocócica/prevenção & controle , Vacinas Pneumocócicas/normas , Infecções Relacionadas à Prótese/prevenção & controle , Pré-Escolar , Implante Coclear/efeitos adversos , Feminino , Humanos , Lactente , Masculino , Auditoria Médica , Meningite Pneumocócica/epidemiologia , Morbidade , Vacinas Pneumocócicas/administração & dosagem , Guias de Prática Clínica como Assunto , Infecções Relacionadas à Prótese/epidemiologia , Fatores de Risco , Design de Software , Reino Unido/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA