Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Med Eng Phys ; 118: 104023, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37536829

RESUMO

BACKGROUND: Ultrasonic neuromodulation (UNMOD) provides a non-invasive brain stimulation. However, the high-resolution region-specificity of UNMOD with a single element transducer combined with a mechanical positioning system could have limits due to the intrinsic positioning error from mechanical systems. OBJECTIVE/HYPOTHESIS: A phased array system could lead to highly selective neuromodulation with electronic control. METHODS: A specialized phased-array system with a robotic arm is implemented for a rhesus monkey model. Various primary motor cortex areas related to tail, hand, and mouth were stimulated with a 200 µm step size. The ultrasonic parameters were ISPTA of 840 mW/cm2, pulse repetition frequency of 100 Hz, and a 5% duty factor at 600 kHz. The induced movement were recorded and analyzed. RESULTS: Separate digits, mouth, and tongue motions were successfully induced by electronically controlling the focus. The identical body part movement could be induced when the focus was moved back to the identical primary motor cortex with electronic control. Accordingly, the reproducibility of UNMOD could be partially validated with rhesus monkey model. CONCLUSION: A phased-array system appears to have a potential for the non-invasive and region-selective neuromodulation method.


Assuntos
Procedimentos Cirúrgicos Robóticos , Reprodutibilidade dos Testes , Ultrassonografia , Transdutores , Neurotransmissores
2.
Skin Res Technol ; 28(2): 291-298, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35034386

RESUMO

BACKGROUND: Sonophoresis can increase the delivery efficiency of various drugs into the skin. A recent advance in sonophoresis is the use of ultrasound-responsive liquid-core nuclei (URLN) to increase the probability of cavitation. In this study, we developed a URLN and ultrasound device, and demonstrated its effectiveness through in vitro and clinical tests. MATERIALS AND METHODS: Three types of experiments were designed to evaluate the efficiency of sonophoresis with URLN. First, a Franz diffusion cell with cosmetic ingredients was used to analyze quantitatively the amount of drug delivered to the porcine skin. Second, after the application of sonophoresis with URLN, the porcine skin surface was examined using scanning electron microscopy (SEM) to see the changes in morphology. Finally, a clinical test was performed to verify the utility of sonophoresis with URLN. RESULTS: The results indicate that sonophoresis with URLN can increase the amount of compound delivered by approximately 11.9-fold over 6 h for niacinamide and by 7.33-fold over 6 h for adenosine. In addition, we observed approximately 20-30 µm sized pores on porcine skin in SEM images. In clinical testing, the application of sonophoresis with cosmetics containing URLN for 3 min improved the efficiency of transdermal drug delivery by 1.9-fold, the depth of absorption by 2.0-fold, and the speed of absorption by 2.0-fold at 30 min after application. CONCLUSION: We expect that sonophoresis with specialized URLN in transdermal drug delivery could be used widely for various skin-related applications.


Assuntos
Absorção Cutânea , Pele , Administração Cutânea , Animais , Sistemas de Liberação de Medicamentos/métodos , Humanos , Preparações Farmacêuticas/metabolismo , Pele/diagnóstico por imagem , Pele/metabolismo , Suínos , Ultrassom/métodos , Ultrassonografia
4.
Ultrasound Med Biol ; 46(10): 2775-2784, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32653208

RESUMO

The purpose of this study was to develop and preliminarily evaluate phospholipid-shelled nanodroplets (NDs) encapsulating perfluoropentane (PFP) and radioactive 64Cu as a hybrid positron emission tomography (PET)-ultrasound (US) probe. PFP NDs were fabricated by mixing liquid-phase PFP with a phospholipid solution. The 64Cu was encapsulated into the NDs in a size-controlled manner by exploiting the hydrophobicity of 64Cu-diacetyl-bis(N4-methylthiosemicarbazone) (64Cu-ATSM) using a vial mixer and an extruder. The fabricated 64Cu-loaded PFP NDs (64Cu-PFP NDs) were evaluated using in vitro/in vivo PET-computed tomography (PET-CT), US imaging and transmission electron microscopy. In the in vitro PET images, the 64Cu-PFP NDs were observed as a hot spot in the lower section of the test tube. In the acquired US images, the mean region of interest brightness values of 64Cu-PFP NDs were revealed by their strong echo image. In a tumor-bearing mouse animal model, tumor uptake of the 64Cu-PFP NDs was low, that is, approximately 65%, compared with that of only free 64Cu, as determined by PET-delayed imaging analysis. The dual-function concept of the NDs is expected to contribute to the prognosis and effectiveness of therapy by fusing the science and technology of nuclear medicine and US.


Assuntos
Radioisótopos de Cobre , Fluorocarbonos , Nanoestruturas , Neoplasias/diagnóstico por imagem , Neoplasias/terapia , Tomografia por Emissão de Pósitrons/métodos , Animais , Modelos Animais de Doenças , Feminino , Camundongos , Camundongos Endogâmicos BALB C , Ultrassonografia
5.
Eur Radiol ; 26(1): 225-34, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25991485

RESUMO

OBJECTIVES: The aim of our study was to determine the diagnostic value of a novel image analysis method called parametric response mapping (PRM) for prediction of intrahepatic recurrence of hepatocellular carcinoma (HCC) treated with conventional transcatheter arterial chemoembolization (TACE). METHODS: This retrospective study was approved by the IRB. We recruited 55 HCC patients who achieved complete remission (CR) after TACE and received longitudinal multiphasic liver computed tomography (CT). The patients fell into two groups: the recurrent tumour group (n = 29) and the non-recurrent tumour group (n = 26). We applied the PRM analysis to see if this technique could distinguish between the two groups. The results of the PRM analysis were incorporated into a prediction algorithm. We retrospectively removed data from the last time point and attempted to predict the response to therapy of the removed data. RESULTS: The PRM analysis was able to distinguish between the non-recurrent and recurrent groups successfully. The prediction algorithm detected response to therapy with an area under the curve (AUC) of 0.76, while the manual approach had AUC 0.64. CONCLUSIONS: Adopting PRM analysis can potentially distinguish between recurrent and non-recurrent HCCs and allow for prediction of response to therapy after TACE. KEY POINTS: Parametric response mapping (PRM) could help assess patients with recurrent HCCs after TACE. Parametric response mapping could direct patients to individualized therapy. Longitudinal CT images were analyzed with advanced image analysis method.


Assuntos
Antineoplásicos/administração & dosagem , Carcinoma Hepatocelular/diagnóstico por imagem , Cateterismo Periférico/métodos , Quimioembolização Terapêutica/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Recidiva Local de Neoplasia/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Carcinoma Hepatocelular/terapia , Feminino , Humanos , Injeções Intra-Arteriais , Neoplasias Hepáticas/tratamento farmacológico , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/prevenção & controle , Estudos Retrospectivos
6.
Anal Chem ; 87(12): 5914-20, 2015 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-25811309

RESUMO

Quantitative detection of the biological properties of living cells is essential for a wide range of purposes, from the understanding of cellular characteristics to the development of novel drugs in nanomedicine. Here, we demonstrate that analysis of cell biological properties within a microfluidic dielectrophoresis device enables quantitative detection of cellular biological properties and simultaneously allows large-scale measurement in a noise-robust and probeless manner. Applying this technique, the static and dynamic biological responses of live B16F10 melanoma cells to the small-molecule drugs such as N-ethylmaleimide (NEM) and [(dihydronindenyl)oxy]alkanoic acid (DIOA) were quantitatively and statistically examined by investigating changes in movement of the cells. Measurement was achieved using subtle variations in dielectrophoresis (DEP) properties of the cells, which were attributed to activation or deactivation of K(+)/Cl(-) cotransporter channels on the cell membrane by the small-molecule drugs, in a microfluidic device. On the basis of quantitative analysis data, we also provide the first report of the shift of the complex permittivity of a cell induced by the small-molecule drugs. In addition, we demonstrate interesting quantifiable parameters including the drug effectiveness coefficient, antagonistic interaction coefficient, kinetic rate, and full width at half-maximum, which corresponded to changes in biological properties of B16F10 cells over time when NEM and DIOA were introduced alone or in combination. Those demonstrated parameters represent very useful tools for evaluating the effect of small-molecule drugs on the biological properties of cells.


Assuntos
Ácidos Carboxílicos/análise , Etilmaleimida/análise , Indenos/análise , Dispositivos Lab-On-A-Chip , Técnicas Analíticas Microfluídicas/instrumentação , Animais , Ácidos Carboxílicos/farmacologia , Membrana Celular/efeitos dos fármacos , Sobrevivência Celular/efeitos dos fármacos , Relação Dose-Resposta a Droga , Eletroforese , Etilmaleimida/farmacologia , Indenos/farmacologia , Camundongos , Relação Estrutura-Atividade , Simportadores/antagonistas & inibidores , Simportadores/metabolismo , Fatores de Tempo , Células Tumorais Cultivadas , Cotransportadores de K e Cl-
7.
Abdom Imaging ; 39(3): 518-25, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24519566

RESUMO

PURPOSE: Accurate assessment of viability of hepatocellular carcinoma (HCC) after transcatheter arterial chemoembolization (TACE) is important for therapy planning. The purpose of this study is to determine the diagnostic value of a novel image analysis method called parametric response mapping (PRM) in predicting viability of tumor in HCC treated with TACE for dynamic CT images. METHODS: 35 patients who had 35 iodized-oil defect areas (IODAs) in HCCs treated with TACE were included in our study. These patients were divided into two groups, one group with viable tumors (n = 22) and the other group with non-viable tumors (n = 13) in the IODA. All patients were followed up using triple-phase dynamic CT after the treatment. We compared (a) manual analysis, (b) using PRM results, and (c) using PRM results with automatic classifier to distinguish between two tumor groups based on dynamic CT images from two longitudinal exams. Two radiologists performed the manual analysis. The PRM approach was implemented using prototype software. We adopted an off-the-shelf k nearest neighbor (kNN) classifier and leave-one-out cross-validation for the third approach. The area under the curve (AUC) values were compared for three approaches. RESULTS: Manual analysis yielded AUC of 0.74, using PRM results yielded AUC of 0.84, and using PRM results with an automatic classifier yielded AUC of 0.87. CONCLUSIONS: We improved upon the standard manual analysis approach by adopting a novel image analysis method of PRM combined with an automatic classifier.


Assuntos
Biomarcadores Tumorais , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/terapia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/terapia , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Idoso , Área Sob a Curva , Quimioembolização Terapêutica/métodos , Meios de Contraste , Feminino , Humanos , Iohexol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Curva ROC , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos
8.
Nanotechnology ; 22(22): 225303, 2011 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-21464524

RESUMO

Conducting polymers (CPs) have attracted a great deal of attention due to their unique properties; these properties are useful in implementing various functional devices, such as memory, and chemical and biological sensors. In particular, the nanopatterning of CPs is a key technology that will accelerate the adoption of CPs in fabricating nanoscaled multifunctional devices. This paper presents an innovative technique for forming polypyrrole nanowire (PPy-NW) patterns, without any additional pretreatment on the gold surface, using atomic force microscopy (AFM) and ultra-short pulse voltage. Applying the ultra-short pulse voltage to the AFM tip has the following advantage: since the electrochemical current is extremely localized around the tip, the successful formation of CP nanowires results. This is because the pulse width is much shorter than the resistor-capacitor (RC) time constant of the equivalent electrochemical circuit of our experimental set-up. This paper provides systematic results regarding the dimensional variation of the PPy-NW patterns produced by varying the electrical conditions of the ultra-short pulse, such as the pulse amplitude, width, and frequency. The results show that use of an ultra-short pulse is essential in fabricating PPy-NW patterns. Additionally, an ultra-short pulse offers excellent pattern controllability for both width (353 nm ∼ 3.37 µm) and height (2.0 ∼ 88.3 nm).


Assuntos
Técnicas Eletroquímicas/métodos , Microscopia de Força Atômica/métodos , Nanofios/química , Polímeros/química , Pirróis/química , Ouro/química , Nanofios/ultraestrutura , Polimerização
9.
Lasers Surg Med ; 42(5): 412-7, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20583247

RESUMO

BACKGROUND AND OBJECTIVES: Various physical methods, such as microneedling, laser ablation, sonophoresis, and sandpaper, have been widely studied to enhance the transdermal delivery of tissue optical clearing (TOC) agents. A previous study demonstrated that the microneedling method could effectively enhance the permeability of a TOC agent through the skin barrier. STUDY DESIGN/MATERIALS AND METHODS: In this study, we introduce a new physical combination method which utilizes both microneedling and sonophoresis to further enhance the transdermal delivery of a TOC agent, glycerol. Porcine skin samples were divided into a control group treated only with the microneedle roller and a test group treated with both the microneedle roller and sonophoresis. Glycerol was applied topically after microneedling. The optimal concentration and transdermal delivery efficacy of glycerol were quantitatively evaluated. RESULTS: A 70% glycerol solution was determined to be the optimal concentration for the combination method. The combination method resulted in approximately a 2.3-fold higher transdermal diffusion rate of glycerol when compared to the microneedling method alone. CONCLUSION: The combination method and optimal glycerol concentration effectively enhanced transdermal delivery of glycerol by accelerating the diffusion rate through the skin barrier.


Assuntos
Glicerol/administração & dosagem , Agulhas , Fonoforese , Administração Cutânea , Animais , Desenho de Equipamento , Suínos
10.
Acad Radiol ; 17(5): 614-23, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20188602

RESUMO

RATIONALE AND OBJECTIVES: Positron emission tomography (PET) is actively investigated to aid in target volume definition for radiation therapy. The objectives of this study were to apply an automatic computer algorithm to compute target volumes and to validate the algorithm using histologic data from real human prostate cancer. MATERIALS AND METHODS: Various modalities for prostate imaging were performed. In vivo imaging included T2 3-T magnetic resonance imaging and (11)C-choline PET. Ex vivo imaging included 3-T magnetic resonance imaging, histology, and block face photos of the prostate specimen. A novel registration method based on mutual information and thin-plate splines was applied to all modalities. Once PET is registered with histology, a voxel-by-voxel comparison between PET and histology is possible. A thresholding technique based on various fractions of the maximum standardized uptake value in the tumor was applied, and the respective computed threshold volume on PET was compared with histologic truth. RESULTS: Sixteen patients whose primary tumor volumes ranged from 1.2 to 12.6 cm(3) were tested. PET has low spatial resolution, so only tumors > 4 cm(3) were considered. Four cases met this criterion. A threshold value of 60% of the (11)C-choline maximum standardized uptake value resulted in the highest volume overlap between threshold volume on PET and histology. Medial axis distances between threshold volume on PET and histology showed a mean error of 7.7 +/- 5.2 mm. CONCLUSIONS: This is a proof-of-concept study demonstrating for the first time that histology-guided thresholding on PET can delineate tumor volumes in real human prostate cancer.


Assuntos
Colina , Interpretação de Imagem Assistida por Computador/métodos , Reconhecimento Automatizado de Padrão/métodos , Tomografia por Emissão de Pósitrons/métodos , Neoplasias da Próstata/diagnóstico , Técnica de Subtração , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Inteligência Artificial , Radioisótopos de Carbono , Humanos , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Masculino , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
11.
Int J Hyperthermia ; 25(7): 566-80, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19848619

RESUMO

An anti-focus is defined as the point where the pressure amplitude is zero. As an active protection means in focused ultrasound, the anti-focus was researched through simulations. A 513 element, 1 MHz, 15 cm focal depth, spherical shape transducer with a central hold was used for the simulation. An anti-focus was implemented with two different approaches and the simulation results were compared. First, the interference among foci was compared to the summation of the individual focus fields. Second, the interference among anti-foci was compared to the multiplication of the individual anti-focus fields. The minimum distance between a focus and an anti-focus was determined by the comparison between intended control values and the simulation results. The field simulation results indicate that the minimum distance to control the field is approximately 3 mm in the lateral direction and 15 mm in the axial direction. The results also demonstrate that a specific zone can be effectively protected with the addition of anti-foci and that the field can be effectively implemented by switching type amplifier systems. Results demonstrate the potential for anti-foci to significantly reduce the collateral damage in focused ultrasound through improved field control.


Assuntos
Terapia por Ultrassom/métodos , Simulação por Computador , Desenho de Equipamento , Modelos Teóricos , Transdutores , Ultrassom
12.
Ultrasonics ; 49(6-7): 565-8, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19345389

RESUMO

The optimal dosage of ultrasound contrast agent model for ultrasound surgery was explored. A specific ultrasound contrast agent Albunex was chosen for simulation. The model was developed based on a dilute bubbly liquid model proposed by Ye and Ding [Z. Ye, L. Ding, Acoustic dispersion and attenuation relations in bubbly mixture, J. Acoust. Soc. Am. 98 (3) (1995) 1629-1636]. The numerical simulation suggests that 2 MHz is more efficient than 1 MHz to thermally treat cancer in deep tissue with the optimal dosage of 3 ml. On the other hand, the simulation also suggests 3 MHz center frequency with the optimal dosage of 1.6 ml is adequate for prostate cancer treatment with transrectal equipment. The simulation is expected to valid up to 2 MPa incident pressure due to the limitation of the linearized UCA model. Even though it is developed from a single ultrasound contrast agent, this model is expected to be useful for any ultrasound contrast agent as long as the necessary parameters are provided.


Assuntos
Albuminas/administração & dosagem , Meios de Contraste/administração & dosagem , Neoplasias/terapia , Terapia por Ultrassom/métodos , Simulação por Computador , Relação Dose-Resposta a Droga , Temperatura Alta , Humanos , Dinâmica não Linear , Pressão , Terapia por Ultrassom/instrumentação
13.
Artigo em Inglês | MEDLINE | ID: mdl-16212250

RESUMO

Sufficiently high intensity ultrasound can create hyperechoic regions in an ultrasound image due to local bubble generation. We explore the link between the temporal extent of these hyperechoic regions and tissue damage caused by ultrasound therapy. The decay rate of increased echogenicity from the focal zone in insonated live exteriorized canine kidney was quantified and correlated to the spatial extent of tissue damage. The decay half-time, t(half), defined as the time for echogenicity enhancement to decay by a factor of 2, was observed in all cases to be greater than 41 s in spatial zones in which extensive histological damage was observed. In cases in which the measured thalf was less than 11 s, the damage was limited to minor hemorrhage, or it was not detected. These t(half) discrimination boundaries of 41 and 11 s were not statistically different for cases in which contrast agent was used to enhance therapeutic efficiency. This was true even though contrast agent infusion significantly reduced the therapy pulse duration threshold for damage production.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Rim/diagnóstico por imagem , Rim/efeitos da radiação , Lesões por Radiação/diagnóstico por imagem , Lesões por Radiação/prevenção & controle , Medição de Risco/métodos , Terapia por Ultrassom/efeitos adversos , Animais , Cães , Rim/lesões , Lesões por Radiação/etiologia , Fatores de Risco , Índice de Gravidade de Doença , Ultrassonografia
14.
Artigo em Inglês | MEDLINE | ID: mdl-16212251

RESUMO

Stabilized microbubble ultrasound contrast agents (UCA) have potential to aid tissue ablation during ultrasound surgery by enhancing both cavitational and thermal damage mechanisms. Previously, we showed UCA infused at a rate of 1 microL/kg/min prior to ultrasound exposure could reduce the total energy required to produce tissue damage by up to two orders of magnitude. In this paper, we evaluate thresholds for macroscopic tissue damage with UCA infusion rates (IR) of 0.1, 0.3, 1, 3, and 10 microL/kg/min to determine IR potentially effective for ultrasound therapy. Canine kidneys were surgically externalized and insonified with single exposures of focused ultrasound. Incident exposures were 1.44 MHz tone bursts, either 250 ms in duration with intensity between 500 W/cm2 and 3200 W/cm2, or 100 micros to 1 s in duration with intensity equal to 3200 W/cm2. Probabilities of tissue damage occurrence were determined for each set of exposure conditions (intensity, duration, and IR). A threshold intensity and threshold duration, defined as the quantities for which tissue damage occurred with probability equal to 0.5, were estimated for each IR. Results show that, as IR increased from 0.1 to 10 microL/kg/min, the threshold intensity decreased by up to a factor of 3, and threshold duration decreased by up to a factor of 200. Microbubble introduction at IR up to 10 microL/kg/min thus may be effective in aiding ultrasound therapy.


Assuntos
Albuminas/uso terapêutico , Fluorocarbonos/uso terapêutico , Rim/efeitos da radiação , Terapia por Ultrassom/métodos , Animais , Meios de Contraste/uso terapêutico , Cães , Relação Dose-Resposta à Radiação , Feminino , Infusões Intra-Arteriais , Rim/diagnóstico por imagem , Doses de Radiação , Ultrassonografia
15.
Artigo em Inglês | MEDLINE | ID: mdl-16422409

RESUMO

Nonlinear beam mixing with microbubbles was explored to create a pseudo point source for aberration correction of therapeutic ultrasound. A damping coefficient for a bubble driven by a dual frequency sound field was derived by revisiting Prosperetti's linearized damping model. As a result, the overall damping term for dual frequency was obtained by linear summation of two damping terms for each frequency. The numerical simulation based on the bubble model suggests that the most efficient size range to generate a 1 MHz frequency from 4 MHz and 5 MHz sound sources is 2.6 to 3.0 microm. Furthermore, this size range constitutes the primary distribution of a specific ultrasound contrast agent. When a chamber of 0.1% of the diluted agent is sonified by 4 MHz and 5 MHz sound beams with 80 degrees incident angle between them, an approximately 100 Pa, 1 MHz difference frequency signal can be measured approximately 10 cm away. In addition, the received 1 MHz difference frequency signal shows omni-directional characteristics, even though the overlap zone of the two sound beams is on the order of the difference frequency wavelength. Therefore, the induced sound source can be considered as a pseudo point source and is expected to be useful for aberration correction for therapeutic ultrasound.


Assuntos
Artefatos , Tecido Conjuntivo/fisiologia , Tecido Conjuntivo/efeitos da radiação , Modelos Biológicos , Radiometria/métodos , Terapia por Ultrassom/métodos , Animais , Simulação por Computador , Humanos , Dinâmica não Linear , Doses de Radiação , Espalhamento de Radiação , Ultrassom
16.
Artigo em Inglês | MEDLINE | ID: mdl-14609069

RESUMO

Experiments were conducted to explore the potential of stabilized microbubbles for aiding tissue ablation during ultrasound therapy. Surgically exteriorized canine kidneys were irradiated in situ using single exposures of focused ultrasound. In each experiment, up to eight separate exposures were placed in the left kidney. The right kidney was then similarly exposed, but while an ultrasound contrast agent was continually infused. Kidneys were sectioned and examined for gross observable tissue damage. Tissue damage was produced more frequently, by lower intensity and shorter duration exposures, in kidneys irradiated with the contrast agent present. Using 250-ms exposures, the minimum intensity that produced damage was lower in kidneys with microbubbles than those without (controls) in 10 of 11 (91%) animals. In a separate study using approximately 3200 W/cm2 exposures, the minimum duration that produced damage was shorter after microbubbles were introduced in 11 of 12 (92%) animals. With microbubbles, gross observable tissue damage was produced with exposure intensity > or = approximately 800 W/cm2 and exposure duration > or = 10 micros. The overall intensity and duration tissue damage thresholds were reduced by approximately 2x and approximately 100x, respectively. Results indicate that acoustic cavitation is a primary damage mechanism. Lowering in vivo tissue damage thresholds with stabilized microbubbles acting as cavitation nuclei may make acoustic cavitation a more predictable, and thus practical, mechanism for noninvasive ultrasound surgery.


Assuntos
Albuminas , Fluorocarbonos , Rim/patologia , Rim/efeitos da radiação , Microbolhas , Lesões por Radiação/prevenção & controle , Terapia por Ultrassom/métodos , Animais , Meios de Contraste , Dissecação/métodos , Cães , Relação Dose-Resposta à Radiação , Rim/diagnóstico por imagem , Rim/cirurgia , Necrose , Terapia por Ultrassom/instrumentação , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA