Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 93
Filtrar
1.
Transl Med UniSa ; 21: 7-9, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32123673

RESUMO

Foot ulcers associated with Diabetes mellitus require immediate attention due to risk of amputation if left untreated. Herein we focus on the mitigating risk factors and physiopathology of the diabetic foot, recounting our own surgical approach and revascularization procedures.

2.
Eur J Vasc Endovasc Surg ; 53(4): 511-519, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-28274551

RESUMO

OBJECTIVES: The aim was to determine current practice for the treatment of carotid stenosis among 12 countries participating in the International Consortium of Vascular Registries (ICVR). METHODS: Data from the United States Vascular Quality Initiative (VQI) and the Vascunet registry collaboration (including 10 registries in Europe and Australasia) were used. Variation in treatment modality of asymptomatic versus symptomatic patients was analysed between countries and among centres within each country. RESULTS: Among 58,607 procedures, octogenarians represented 18% of all patients, ranging from 8% (Hungary) to 22% (New Zealand and Australia). Women represented 36%, ranging from 29% (Switzerland) to 40% (USA). The proportion of carotid artery stenting (CAS) among asymptomatic patients ranged from 0% (Finland) to 26% (Sweden) and among symptomatic patients from 0% (Denmark) to 19% (USA). Variation among centres within countries for CAS was highest in the United States and Australia (from 0% to 80%). The overall proportion of asymptomatic patients was 48%, but varied from 0% (Denmark) to 73% (Italy). There was also substantial centre level variation within each country in the proportion of asymptomatic patients, most pronounced in Australia (0-72%), Hungary (5-55%), and the United States (0-100%). Countries with fee for service reimbursement had higher rates of treatment in asymptomatic patients than countries with population based reimbursement (OR 5.8, 95% CI 4.4-7.7). CONCLUSIONS: Despite evidence about treatment options for carotid artery disease, the proportion of asymptomatic patients, treatment modality, and the proportion of women and octogenarians vary considerably among and within countries. There was a significant association of treating more asymptomatic patients in countries with fee for service reimbursement. The findings reflect the inconsistency of the existing guidelines and a need for cooperation among guideline committees all over the world.


Assuntos
Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/terapia , Endarterectomia das Carótidas/tendências , Procedimentos Endovasculares/tendências , Disparidades em Assistência à Saúde/tendências , Padrões de Prática Médica/tendências , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Doenças Assintomáticas , Austrália , Estenose das Carótidas/economia , Estenose das Carótidas/cirurgia , Distribuição de Qui-Quadrado , Endarterectomia das Carótidas/efeitos adversos , Endarterectomia das Carótidas/economia , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/economia , Procedimentos Endovasculares/instrumentação , Europa (Continente) , Planos de Pagamento por Serviço Prestado/tendências , Feminino , Fidelidade a Diretrizes/tendências , Disparidades em Assistência à Saúde/economia , Humanos , Seguro Saúde/tendências , Modelos Lineares , Masculino , Nova Zelândia , Razão de Chances , Guias de Prática Clínica como Assunto , Padrões de Prática Médica/economia , Sistema de Registros , Fatores de Risco , Fatores Sexuais , Stents/tendências , Resultado do Tratamento , Estados Unidos
5.
Artigo em Inglês | MEDLINE | ID: mdl-26417937

RESUMO

Endovascular repair of abdominal aortic aneurysm has become a milestone in the treatment of patients with abdominal aortic aneurysm.Technological improvement allows treatment in more and more complex cases. This review summarizes all grafts available in the market. At the best of our knowledge a complete review of most important trial on this topic are provided and at least technical tips and tricks for standard cases are recapitulated.

7.
J Cardiovasc Surg (Torino) ; 56(5): 787-91, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25996843

RESUMO

According to the World Health Organization, every year, 5 million peoples die for stroke and another 5 million are permanently disabled. Although there are many causes of acute stroke, a common treatable cause of acute stroke is atheromatous narrowing at the carotid bifurcation. Carotid endarterectomy is still the standard of car, even if carotid artery stenting (CAS) has become an effective, less invasive alterantive. Unfortunately, CAS procedure is not yet perfect; regardless the use of an embolic protection device (EPD), percutaneous treatment has been correlated with a risk of cerebral ischemic events related to distal embolization. The objective of the IRON-Guard Registry is to evaluate the clinical outcome of treatment by means of stenting with the C-Guard (InspireMD, Boston, MA, USA) in subjects requiring CAS due to significant extracranial carotid artery stenosis with a physician-initiated, Italian, prospective, multicenter, single-arm study. A total of 200 enrolled subjects divided over different centers are planned to be enrolled. CAS will performed by implanting of C-Guard stent. Procedure will be performed according to the physician's standard of care. Standard procedures will be followed based on the Instructions for Use, for the C-Guard device of Inspire. The primary endpoint of this study is the 30-day rate of major adverse events (MAE), defined as the cumulative incidence of any periprocedural (≤30 days postprocedure) death, stroke or myocardial infarction. Secondary endpoints are rate of late ipsilateral stroke (31 through 365 days), system technical success, device malfunctions, major adverse events (MAEs), serious device-related and procedure-related adverse events, target lesion revascularization, and in-stent restenosis rates.


Assuntos
Angioplastia/instrumentação , Estenose das Carótidas/terapia , Sistema de Registros , Projetos de Pesquisa , Stents , Angioplastia/efeitos adversos , Angioplastia/mortalidade , Estenose das Carótidas/complicações , Estenose das Carótidas/diagnóstico , Estenose das Carótidas/mortalidade , Humanos , Itália , Estudos Prospectivos , Desenho de Prótese , Falha de Prótese , Recidiva , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Fatores de Tempo , Tomografia de Coerência Óptica , Resultado do Tratamento
8.
J Cardiovasc Surg (Torino) ; 56(4): 587-97, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25742934

RESUMO

Although traditional surgical repair by aneurysm exclusion and bypass is still considered the gold standard in the treatment of popliteal artery aneurysms (PAAs), the endovascular repair (ER) has been gaining great interest in the last decades. ER offers several advantages over open bypass, including lower morbidity and mortality, and faster functional recovery, but some concerns about migration, occlusion, or fracture remain when a stent graft is deployed across a joint that undergo constant flexion. This review summarizes the current evidence on ER for PAAs. Level I evidence is still very limited, while the majority of published data come from retrospective studies. Moreover the heterogeneity of PAA morphology seems to play a major role in the outcomes after popliteal endografts placement, so that many anatomical criteria should be taken into account to determine which patient is best treated endovascularly. In conclusion, while it is unlike that endovascular treatment may displace open surgical bypass in the near future, it indeed does provide a feasible option for selected patients with high surgical risk and good anatomical features.


Assuntos
Aneurisma/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Artéria Poplítea/cirurgia , Aneurisma/diagnóstico , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Humanos , Seleção de Pacientes , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Medição de Risco , Fatores de Risco , Stents , Resultado do Tratamento
9.
J Cardiovasc Surg (Torino) ; 56(5): 763-7, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25604322

RESUMO

AIM: A new stent was designed, conceived for being placed externally around blood vessels to perform vessel banding in a much simple and fast way. In fact it requires the dissection of a single segment of the aortic wall, as its mechanical features allow it to slide on the tunica adventitia. After previous tests (ex vivo and in vivo test), the new stent has been evaluated in vivo long-term study. METHODS: In female pig of average weight of 60 kg, after placement of endoprosthesis in infrarenal abdominal aorta, immediately below renal arteries, aortic banding was performed with new stent at the level of each end of endoprosthesis, identified under fluoroscopic guidance. Pigs were followed up for six months, and acetylsalicylic acid was administrated: 100 mg once a day. After six months, histological evaluation of explanted abdominal aorta was performed. RESULTS: New stent made the aortic banding simple and fast. Postoperative course was uneventful. Histological results were similar to previous 10-week survival tests and not damages of aortic wall were observed. CONCLUSION: Positive outcome of three last long-term survival tests, as of all those ex vitro and in vivo tests previously performed, makes conceivable further scientific investigation and trials.


Assuntos
Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Animais , Aorta Abdominal/patologia , Aspirina/administração & dosagem , Esquema de Medicação , Feminino , Teste de Materiais , Modelos Animais , Inibidores da Agregação Plaquetária/administração & dosagem , Desenho de Prótese , Suínos , Fatores de Tempo
10.
J Cardiovasc Surg (Torino) ; 56(4): 607-15, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25216219

RESUMO

Patients undergoing major surgery are at risk for postoperative cognitive dysfunction (POCD). The consciousness of the POCD arises new ethical and medico-legal issues that should be identified, managed and, if possible, prevented. Elderly patients still represent a real challenge for physicians and medical science. This challenge can be surmounted not only through technical progress but also by safeguarding the correct ethical behavior at the base of each relationship between a patient and his physician. Effective communication with the elderly patient is a prerequisite for clear and complete information, involving family members and caregivers when necessary. In every case, the identification of patients with pre-existing risk factors of POCD, shortening the period of time preceding the surgery and a proper technique of the procedure as well as physical and intellectual exercises, nutrition and medication play an important role in decreasing the incidence of neurocognitive deficits in the elderly.


Assuntos
Atitude do Pessoal de Saúde , Transtornos Cognitivos/etiologia , Cognição , Consentimento Livre e Esclarecido/ética , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Procedimentos Cirúrgicos Vasculares/ética , Fatores Etários , Idoso , Transtornos Cognitivos/diagnóstico , Transtornos Cognitivos/prevenção & controle , Transtornos Cognitivos/psicologia , Comunicação , Técnicas de Apoio para a Decisão , Avaliação Geriátrica , Humanos , Consentimento Livre e Esclarecido/legislação & jurisprudência , Testes Neuropsicológicos , Relações Médico-Paciente , Valor Preditivo dos Testes , Relações Profissional-Família , Medição de Risco , Fatores de Risco , Revelação da Verdade , Procedimentos Cirúrgicos Vasculares/legislação & jurisprudência
14.
J Cardiovasc Surg (Torino) ; 55(6): 721-30, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25069448

RESUMO

In recent years the number of carotid revascularization has increased steadily. This increased has inevitably resulted in an increase (relative) in complications, both after carotid endarterectomy (CEA) and carotid stenting (CAS), despite the technical evolutions of new available materials and the expertise of the operators. So, complications which may potentially require operative intervention, although not very frequent, are possible. However, after diagnosis, immediate management should be undertaken in order to avoid sequelae which are often irreversible and potentially fatal. To minimize this risk, it's important that these procedures are performed by skilled operators in high-volume Centers of activity. The aim of this review is to assess local complications which can lead to re-interventions after CEA and CAS.


Assuntos
Angioplastia com Balão/efeitos adversos , Doenças das Artérias Carótidas/terapia , Endarterectomia das Carótidas/efeitos adversos , Complicações Pós-Operatórias/terapia , Angioplastia com Balão/instrumentação , Doenças das Artérias Carótidas/diagnóstico , Doenças das Artérias Carótidas/cirurgia , Humanos , Complicações Pós-Operatórias/diagnóstico , Retratamento , Fatores de Risco , Stents , Resultado do Tratamento
15.
J Cardiovasc Surg (Torino) ; 55(6): 779-92, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25017788

RESUMO

Implantation of a vascular prosthesis increases surgical site infection risk by producing a microenvironment conducive to bacterial attachment and biofilm formation, which sustains bacterial colonization and protects encased organisms from host defenses and antimicrobial therapy. Many maneuvers are used in an attempt to reduce infection in arterial reconstructions, but there are no clear guidelines on the most appropriate or effective. As well, there is no good evidence to guide management. A general principle is that indication for removal of the entire infected graft is mandatory when a suture line is involved in the infectious process, an infected anastomotic aneurism and a suture-line hemorrhage is evident, or when a graft-enteric fistula is diagnosed. Conservative, non-resectional management of graft infection is still a respectable solution for selected patients, as those with significant comorbidities, or those where the implanted aortic graft is in a location that precludes excision without causing a high likelihood of morbidity and/or mortality. Anyway, definitive management depends on the patient's condition and a tailored approach should be always offered. Surgical techniques favor in terms of mortality, patency and reinfection rate the in situ reconstruction. Currently, the choice of the technique used relies on center and operator's experience. This article summarizes the incidence of graft infection, analyze the predisponding factors to graft infection, and review current strategies for prevention and treatment of prosthesis and endograft infection.


Assuntos
Antibacterianos/uso terapêutico , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Prótese Vascular/efeitos adversos , Remoção de Dispositivo , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Infecções Relacionadas à Prótese/prevenção & controle , Infecções Relacionadas à Prótese/terapia , Stents/efeitos adversos , Humanos , Seleção de Pacientes , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/microbiologia , Reoperação , Medição de Risco , Fatores de Risco , Resultado do Tratamento
16.
Nutr Metab Cardiovasc Dis ; 24(4): 355-69, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24486336

RESUMO

Diabetic foot (DF) is a chronic and highly disabling complication of diabetes. The prevalence of peripheral arterial disease (PAD) is high in diabetic patients and, associated or not with peripheral neuropathy (PN), can be found in 50% of cases of DF. It is worth pointing out that the number of major amputations in diabetic patients is still very high. Many PAD diabetic patients are not revascularised due to lack of technical expertise or, even worse, negative beliefs because of poor experience. This despite the progress obtained in the techniques of distal revascularisation that nowadays allow to reopen distal arteries of the leg and foot. Italy has one of the lowest prevalence rates of major amputations in Europe, and has a long tradition in the field of limb salvage by means of an aggressive approach in debridement, antibiotic therapy and distal revascularisation. Therefore, we believe it is appropriate to produce a consensus document concerning the treatment of PAD and limb salvage in diabetic patients, based on the Italian experience in this field, to share with the scientific community.


Assuntos
Pé Diabético/terapia , Procedimentos Endovasculares/normas , Salvamento de Membro/normas , Doença Arterial Periférica/terapia , Procedimentos Cirúrgicos Vasculares/normas , Amputação Cirúrgica/normas , Angioplastia com Balão/normas , Fármacos Cardiovasculares/uso terapêutico , Consenso , Pé Diabético/diagnóstico , Pé Diabético/epidemiologia , Humanos , Doença Arterial Periférica/diagnóstico , Doença Arterial Periférica/epidemiologia , Valor Preditivo dos Testes , Prevalência , Fatores de Risco , Resultado do Tratamento
17.
Q J Nucl Med Mol Imaging ; 58(1): 46-54, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24231796

RESUMO

Vascular and endovascular procedures are typically very "clean" procedures, with a very low infection rate. However, these complications, although rare, are unfortunately associated with a high rate of morbidity and mortality. The first rule to effectively treat the infection is always prevention, but when the infection has been established the only solution is given by an early diagnosis and proper medical care and often surgical treatment. The hardest thing is to obtain is an early and correct diagnosis, especially for low-grade infections. The purpose of our work was to strengthen the conviction that only an integrated work as a team will enable effective and quick management of this serious complication.


Assuntos
Prótese Vascular/efeitos adversos , Sistemas de Apoio a Decisões Clínicas , Procedimentos Endovasculares/normas , Infecções/diagnóstico por imagem , Infecções/diagnóstico , Procedimentos Cirúrgicos Vasculares/normas , Procedimentos Endovasculares/métodos , Fluordesoxiglucose F18 , Humanos , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos , Fatores de Risco , Tomografia Computadorizada por Raios X/métodos , Ultrassonografia/métodos , Procedimentos Cirúrgicos Vasculares/métodos
18.
J Cardiovasc Surg (Torino) ; 55(1): 33-40, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24356044

RESUMO

When Juan Parodi implanted an endograft in a human body for the first time on September 7, 1990 in Buenos Aires, Argentina, the delivery system of the handmade device was primitive, extremely rigid, and had a bulky profile of 27 French (F). Since then, stent-graft technology has evolved rapidly, limitations of earlier-generation devices have been overtaken, and endovascular aneurysm repair (EVAR) eligibility has increased enormously. Nevertheless (still) challenging aortoiliac anatomy such as short and complex proximal aortic neck seal zones and narrow access vessels are responsible for EVAR ineligibility in up to 50% of cases. The Ovation Prime abdominal stent-graft system (TriVascular, Inc., Santa Rosa, CA, USA) is a trimodular device designed with the aortic body delivered via a flexible, hydrophilic-coated, ultra-low profile catheter (14-F outer diameter - OD). The aortic body is provided with a suprarenal nitinol stent with anchors that provide active fixation, while a network of rings and channels that are inflated with a low-viscosity radiopaque polymer during stent-graft deployment, provides effective sealing. The previous EVAR technology aimed to both anchor and seal using stents combined with fabric, with neither optimized for their roles and each forced to compete for the same space within their delivery catheters, which inevitably led to larger profile of the delivery system. The technical revolution of the Ovation endograft includes the idea to truly uncouple the stages of stent-graft fixation and seal during the procedure. In the Ovation endograft platform, stent and fabric are not competing the same space within the delivery system and an ultra-low profile delivery can be achieved without compromise. With such a low-profile delivery catheter, approximately 90% of men and 70% of women with abdominal aortic aneurysm have access vessel diameters considered fit for endovascular repair. The aim of this review paper was to analyze the main properties of Ovation endograft, to emphasize the advantage of the ultra-low profile device, and to sum up current literature.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Dispositivos de Acesso Vascular , Aneurisma da Aorta Abdominal/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Desenho de Equipamento , Humanos , Desenho de Prótese , Resultado do Tratamento
19.
J Cardiovasc Surg (Torino) ; 55(1): 85-92, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24356050

RESUMO

AIM: The aim of this paper was to evaluate the influence of a challenging neck on mid-term results using the Endurant I stent-graft system in high risk patients. METHODS: A retrospective study was conducted on a prospectively compiled database of 72 elective patients with challenging neck treated with the Endurant I system (Endurant Stent Graft, Medtronic AVE, Santa Rosa, CA, USA). These patients were compared to a control group (65 patients) without significant neck problems. The endpoints were mid-term 2-years technical, clinical success and the event free survival of all treated patients. RESULTS: Mean age was 76.12 years; 76.6% of patients were males. Risk factors and preoperative variables did not differ significantly between the two groups. Only 4 (5.5%) patients of the study group vs. 2 (3.1%) in the control group developed type I endoleak during the follow-up. Three (4.1%) study group patients developed type III endoleak vs. 2 (3.1%) in the control group. All these patients required an adjunct procedure of relining with a new endograft. No type II endoleaks requiring adjunctive endovascular procedures were detected in our series. The 2-year event free survival rate did not differ statistically between the two groups (P=0.425). CONCLUSION: Treatment with the Endurant stent-graft is technically feasible and safe, yielding satisfactory results even in challenging anatomies. Mid-term results are promising and challenge current opinion concerning the negative influence of challenging neck anatomy on EVAR especially after a longer follow-up.


Assuntos
Aneurisma Aórtico/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Idoso de 80 Anos ou mais , Aneurisma Aórtico/diagnóstico , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Intervalo Livre de Doença , Endoleak/etiologia , Endoleak/cirurgia , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Desenho de Prótese , Reoperação , Estudos Retrospectivos , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Ultrassonografia Doppler em Cores
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA