Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
JACC Cardiovasc Interv ; 10(4): 391-399, 2017 02 27.
Artigo em Inglês | MEDLINE | ID: mdl-28231907

RESUMO

OBJECTIVES: Routine device surveillance after successful left atrial appendage closure is recommended to evaluate for intermediate to late complications. The aim of this study was to assess the incidence and clinical impact of these complications on cardiovascular events. METHODS: Centers participating in the Amplatzer Cardiac Plug multicenter study were requested to submit their post-procedural transesophageal echocardiograms for independent adjudication. Thirteen of 22 centers contributed all their post-procedural echocardiograms, which included 344 from 605 consecutive patients. These images were submitted to a core laboratory and reviewed by 2 independent experts for peri-device leak, device-associated thrombus, device embolization, device migration, left atrial appendage thrombus, and left atrial thrombus. Clinical events were prospectively collected by each center. RESULTS: Of the 344 transesophageal echocardiograms, 339 were deemed analyzable. Patients' mean age was 74.4 ± 7.5 years, and 67.3% were men. The mean CHADS2 score was 2.7 ± 1.3, the mean CHA2DS2-VASc score was 4.3 ± 1.5, and the mean HAS-BLED score was 3.0 ± 1.2. Amplatzer Cardiac Plug implantation was successful in all patients. Periprocedural major adverse events occurred in 2.4%. Median clinical follow-up duration was 355 days (range 179 to 622 days). Follow-up transesophageal echocardiography was performed after a median of 134 days (range 88 to 227 days). Device-associated thrombus was observed in 3.2% and peri-device leak in 12.5% (5.5% minimal, 5.8% mild, 0.6% moderate, 0.6% severe). Neither device-associated thrombus nor peri-device leak was associated with an increased risk for cardiovascular events. Independent predictors of device-associated thrombus were smoking (odds ratio: 5.79; p = 0.017) and female sex (odds ratio: 4.22; p = 0.027). CONCLUSIONS: Following successful left atrial appendage closure with the Amplatzer Cardiac Plug, the presence of peri-device leak was relatively low, and device-associated thrombus was infrequent. Neither was associated with increased risk for thromboembolism.


Assuntos
Apêndice Atrial , Fibrilação Atrial/terapia , Cateterismo Cardíaco/instrumentação , Falha de Equipamento , Trombose/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Canadá , Cateterismo Cardíaco/efeitos adversos , Distribuição de Qui-Quadrado , Bases de Dados Factuais , Ecocardiografia Doppler em Cores , Ecocardiografia Transesofagiana , Europa (Continente) , Feminino , Humanos , Incidência , Modelos Logísticos , Masculino , Análise Multivariada , Razão de Chances , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Trombose/diagnóstico por imagem , Fatores de Tempo , Resultado do Tratamento
2.
JACC Cardiovasc Interv ; 9(13): 1374-83, 2016 07 11.
Artigo em Inglês | MEDLINE | ID: mdl-27388826

RESUMO

OBJECTIVES: The aim of this study was to assess predictors of adverse 1-week outcomes and determine the effect of left atrial appendage (LAA) morphology following LAA closure (LAAC) with Amplatzer devices. BACKGROUND: Percutaneous LAAC is a valuable treatment option for stroke prevention in patients with atrial fibrillation. Determinants of procedural safety events with Amplatzer occluders are not well established, and the possibly interrelating effect of LAA anatomy is unknown. METHODS: Between 2009 and 2014, 500 consecutive patients with atrial fibrillation ineligible or at high risk for oral anticoagulation underwent LAAC using Amplatzer devices. Procedure- and device-related major adverse events (MAEs) were defined as the composite of death, stroke, major or life-threatening bleeding, serious pericardial effusion, device embolization, major access-site vascular complication, or need for cardiovascular surgery within 7 days following the intervention. RESULTS: Patients (mean age 73.9 ± 10.1 years) were treated with Amplatzer Cardiac Plug (n = 408 [82%]) or Amulet (n = 92 [18%]) devices. Early procedural success was 97.8%, and MAEs occurred in 29 patients (5.8%). Independent predictors of MAEs included device repositioning (odds ratio: 9.13; 95% confidence interval: 2.85 to 33.54; p < 0.001) and left ventricular ejection fraction <30% (odds ratio: 4.08; 95% confidence interval: 1.49 to 11.20; p = 0.006), with no effect of device type or size. Angiographic LAA morphology, characterized as cauliflower (33%), cactus (32%), windsock (20%), or chicken wing (15%), was not associated with procedural success (p = 0.51) or the occurrence of MAEs (p = 0.78). CONCLUSIONS: In this nonrandomized study, procedural success of LAAC using Amplatzer devices was high. MAEs within 7 days were predicted by patient- and procedure-related factors. Although LAA morphology displayed substantial heterogeneity, outcomes were comparable across the spectrum of LAA anatomies.


Assuntos
Apêndice Atrial , Fibrilação Atrial/terapia , Cateterismo Cardíaco/instrumentação , Dispositivo para Oclusão Septal , Idoso , Idoso de 80 Anos ou mais , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Função do Átrio Esquerdo , Cateterismo Cardíaco/efeitos adversos , Distribuição de Qui-Quadrado , Angiografia Coronária , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Volume Sistólico , Suíça , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda
3.
Clin Res Cardiol ; 104(8): 656-65, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25736061

RESUMO

BACKGROUND: Transcatheter left atrial appendage (LAA) occlusion has been proven to be an effective treatment for stroke prophylaxis in patients with atrial fibrillation. For this purpose, the Amplatzer cardiac plug (ACP) was introduced. Its second generation, the Amulet, was developed for easier delivery, better coverage, and reduction of complications. AIM: To investigate the safety and efficacy of first generation versus second generation Amplatzer occluders for LAA occlusion. METHODS: Retrospective analysis of prospectively collected data from the LAA occlusion registries of the Bern and Zurich university hospitals. Comparison of the last consecutive 50 ACP cases versus the first consecutive 50 Amulet cases in patients with non-valvular atrial fibrillation. For safety, a periprocedural combined endpoint, which is composed of death, stroke, cardiac tamponade, and bailout by surgery was predefined. For efficacy, the endpoint was procedural success. RESULTS: There were no differences between the two groups in baseline characteristics. The percentage of associated interventions during LAA occlusion was high in (78% with ACP vs. 70% with Amulet p = ns). Procedural success was similar in both groups (98 vs. 94%, p = 0.61). The combined safety endpoint for severe adverse events was reached by a similar rate of patients in both groups (6 vs. 8%, p = 0.7). Overall complication rate was insignificantly higher in the ACP group, which was mainly driven by clinically irrelevant pericardial effusions (24 vs. 14%, p = 0.31). Death, stroke, or tamponade were similar between the groups (0 vs. 2%, 0 vs. 0%, or 6 vs. 6%, p = ns). CONCLUSION: Transcatheter LAA occlusion for stroke prophylaxis in patients with atrial fibrillation can be performed with similarly high success rates with first and second generations of Amplatzer occluders. According to this early experience, the Amulet has failed to improve results of LAA occlusion. The risk for major procedural adverse events is acceptable but has to be taken into account when selecting patients for LAA occlusion, a preventive procedure.


Assuntos
Apêndice Atrial/fisiopatologia , Fibrilação Atrial/terapia , Cateterismo Cardíaco/instrumentação , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/mortalidade , Fibrilação Atrial/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Acidente Vascular Cerebral/mortalidade , Acidente Vascular Cerebral/fisiopatologia , Suíça , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA