Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Angew Chem Int Ed Engl ; 63(19): e202400122, 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38494445

RESUMO

Electrochemical acetylene reduction (EAR) employing Cu catalysts represents an environmentally friendly and cost-effective method for ethylene production and purification. However, Cu-based catalysts encounter product selectivity issues stemming from carbon-carbon coupling and other side reactions. We explored the use of secondary metals to modify Cu-based catalysts and identified Cd decoration as particular effective. Cd decoration demonstrated a high ethylene Faradaic efficiency (FE) of 98.38 % with well-inhibited carbon-carbon coupling reactions (0.06 % for butadiene FE at -0.5 V versus reversible hydrogen electrode) in a 5 vol % acetylene gas feed. Notably, ethylene selectivity of 99.99 % was achieved in the crude ethylene feed during prolonged stability tests. Theoretical calculations revealed that Cd metal accelerates the water dissociation on neighboring Cu surfaces allowing more H* to participate in the acetylene semi-hydrogenation, while increasing the energy barrier for carbon-carbon coupling, thereby contributing to a high ethylene semi-hydrogenation efficiency and significant inhibition of carbon-carbon coupling. This study provides a paradigm for a deeper understanding of secondary metals in regulating the product selectivity of EAR electrocatalysts.

2.
Front Pharmacol ; 15: 1337150, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38523645

RESUMO

Pain is a clinical condition that is currently of great concern and is often caused by tissue or nerve damage or occurs as a concomitant symptom of a variety of diseases such as cancer. Severe pain seriously affects the functional status of the body. However, existing pain management programs are not fully satisfactory. Therefore, there is a need to delve deeper into the pathological mechanisms underlying pain generation and to find new targets for drug therapy. Sphingolipids (SLs), as a major component of the bilayer structure of eukaryotic cell membranes, also have powerful signal transduction functions. Sphingolipids are abundant, and their intracellular metabolism constitutes a huge network. Sphingolipids and their various metabolites play significant roles in cell proliferation, differentiation, apoptosis, etc., and have powerful biological activities. The molecules related to sphingolipid metabolism, mainly the core molecule ceramide and the downstream metabolism molecule sphingosine-1-phosphate (S1P), are involved in the specific mechanisms of neurological disorders as well as the onset and progression of various types of pain, and are closely related to a variety of pain-related diseases. Therefore, sphingolipid metabolism can be the focus of research on pain regulation and provide new drug targets and ideas for pain.

3.
FASEB J ; 38(6): e23573, 2024 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-38526846

RESUMO

Familial hypercholesterolemia (FH) is one of the most prevalent monogenetic disorders leading to cardiovascular disease (CVD) worldwide. Mutations in Ldlr, encoding a membrane-spanning protein, account for the majority of FH cases. No effective and safe clinical treatments are available for FH. Adenine base editor (ABE)-mediated molecular therapy is a promising therapeutic strategy to treat genetic diseases caused by point mutations, with evidence of successful treatment in mouse disease models. However, due to the differences in the genomes between mice and humans, ABE with specific sgRNA, a key gene correction component, cannot be directly used to treat FH patients. Thus, we generated a knock-in mouse model harboring the partial patient-specific fragment and including the Ldlr W490X mutation. LdlrW490X/W490X mice recapitulated cholesterol metabolic disorder and clinical manifestations of atherosclerosis associated with FH patients, including high plasma low-density lipoprotein cholesterol levels and lipid deposition in aortic vessels. Additionally, we showed that the mutant Ldlr gene could be repaired using ABE with the cellular model. Taken together, these results pave the way for ABE-mediated molecular therapy for FH.


Assuntos
Hipercolesterolemia , Hiperlipoproteinemia Tipo II , Humanos , Camundongos , Animais , RNA Guia de Sistemas CRISPR-Cas , Hiperlipoproteinemia Tipo II/genética , Hiperlipoproteinemia Tipo II/terapia , Mutação , Hipercolesterolemia/genética , Colesterol , Receptores de LDL/genética , Receptores de LDL/metabolismo
4.
Eur J Pharmacol ; 955: 175859, 2023 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-37429517

RESUMO

Pain is a ubiquitous and highly concerned clinical symptom, usually caused by peripheral or central nervous injury, tissue damage, or other diseases. The long-term existence of pain can seriously affect daily physical function and quality of life and produce great torture on the physiological and psychological levels. However, the complex pathogenesis of pain involving molecular mechanisms and signaling pathways has not been fully elucidated, and managing pain remains highly challenging. As a result, finding new targets to pursue effective and long-term pain treatment strategies is required and urgent. Autophagy is an intracellular degradation and recycling process that maintains tissue homeostasis and energy supply, which can be cytoprotective and is vital in maintaining neural plasticity and proper nervous system function. Much evidence has shown that autophagy dysregulation is linked to the emergence of neuropathic pain, such as postherpetic neuralgia and cancer-related pain. Autophagy has also been connected to pain caused by osteoarthritis and lumbar disc degeneration. It is worth noting that in recent years, studies on traditional Chinese medicine have also proved that several traditional Chinese medicine monomers involve autophagy in the mechanism of pain relief. Therefore, autophagy can serve as a potential regulatory target to provide new ideas and inspiration for pain management.


Assuntos
Dor do Câncer , Neuralgia Pós-Herpética , Neuralgia , Humanos , Qualidade de Vida , Neuralgia/tratamento farmacológico , Neuralgia Pós-Herpética/tratamento farmacológico , Autofagia
5.
Adv Mater ; 35(42): e2303818, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37433306

RESUMO

Electrochemical acetylene reduction (EAR) is a promising strategy for removing acetylene from ethylene-rich gas streams. However, suppressing the undesirable hydrogen evolution is vital for practical applications in acetylene-insufficient conditions. Herein, Cu single atoms are immobilized on anatase TiO2 nanoplates (Cu-SA/TiO2 ) for electrochemical acetylene reduction, achieving an ethylene selectivity of ≈97% with a 5 vol% acetylene gas feed (Ar balance). At the optimal Cu-single-atom loading, Cu-SA/TiO2 is able to effectively suppress HER and ethylene over-hydrogenation even when using dilute acetylene (0.5 vol%) or ethylene-rich gas feeds, delivering a 99.8% acetylene conversion, providing a turnover frequency of 8.9 × 10-2  s-1 , which is superior to other EAR catalysts reported to date. Theoretical calculations show that the Cu single atoms and the TiO2 support acted cooperatively to promote charge transfer to adsorbed acetylene molecules, whilst also inhibiting hydrogen generation in alkali environments, thus allowing selective ethylene production with negligible hydrogen evolution at low acetylene concentrations.

6.
ACS Appl Mater Interfaces ; 15(22): 26273-26284, 2023 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-37230936

RESUMO

Chronic wound infection caused by multidrug-resistant bacteria is a major threat globally, leading to high mortality rates and a considerable economic burden. To address it, an innovative supramolecular nanofiber hydrogel (Hydrogel-RL) harboring antimicrobial peptides was developed based on the novel arginine end-tagging peptide (Pep 6) from our recent study, triggering cross-linking. In vitro results demonstrated that Hydrogel-RL can sustain the release of Pep 6 up to 120 h profiles, which is biocompatible and exhibits superior activity for methicillin-resistant Staphylococcus aureus (MRSA) biofilm inhibition and elimination. A single treatment of supramolecular Hydrogel-RL on an MRSA skin infection model revealed formidable antimicrobial activity and therapeutic effects in vivo. In the chronic wound infection model, Hydrogel-RL promoted mouse skin cell proliferation, reduced inflammation, accelerated re-epithelialization, and regulated muscle and collagen fiber formation, rapidly healing full-thickness skin wounds. To show its vehicle property for wound infection combined therapy, etamsylate, an antihemorrhagic drug, was loaded into the porous network of Hydrogel-RL, which demonstrated improved hemostatic activity. Collectively, Hydrogel-RL is a promising clinical candidate agent for functional supramolecular biomaterials designed for combating multidrug-resistant bacteria and rescuing stalled healing in chronic wound infections.


Assuntos
Staphylococcus aureus Resistente à Meticilina , Infecção dos Ferimentos , Animais , Camundongos , Preparações de Ação Retardada/farmacologia , Hidrogéis/química , Peptídeos/farmacologia , Peptídeos/uso terapêutico , Infecção dos Ferimentos/tratamento farmacológico , Antibacterianos/química
7.
Neurochem Res ; 48(6): 1611-1630, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36738366

RESUMO

Pain, as one of the most prevalent clinical symptoms, is a complex physiological and psychological activity. Long-term severe pain can become unbearable to the body. However, existing treatments do not provide satisfactory results. Therefore, new mechanisms and therapeutic targets need to be urgently explored for pain management. The Sonic hedgehog (Shh) signaling pathway is crucial in embryonic development, cell differentiation and proliferation, and nervous system regulation. Here, we review the recent studies on the Shh signaling pathway and its action in multiple pain-related diseases. The Shh signaling pathway is dysregulated under various pain conditions, such as pancreatic cancer pain, bone cancer pain, chronic post-thoracotomy pain, pain caused by degenerative lumbar disc disease, and toothache. Further studies on the Shh signaling pathway may provide new therapeutic options for pain patients.


Assuntos
Dor do Câncer , Neoplasias Pancreáticas , Humanos , Proteínas Hedgehog/metabolismo , Transdução de Sinais/fisiologia , Neoplasias Pancreáticas/metabolismo , Diferenciação Celular
8.
Technol Cancer Res Treat ; 21: 15330338221105724, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35790457

RESUMO

Purpose: To evaluate the accuracy of deep-learning-based auto-segmentation of the superior constrictor, middle constrictor, inferior constrictor, and larynx in comparison with a traditional multi-atlas-based method. Methods and Materials: One hundred and five computed tomography image datasets from 83 head and neck cancer patients were retrospectively collected and the superior constrictor, middle constrictor, inferior constrictor, and larynx were analyzed for deep-learning versus multi-atlas-based segmentation. Eighty-three computed tomography images (40 diagnostic computed tomography and 43 planning computed tomography) were used for training the convolutional neural network, and for atlas-based model training. The remaining 22 computed tomography datasets were used for validation of the atlas-based auto-segmentation versus deep-learning-based auto-segmentation contours, both of which were compared with the corresponding manual contours. Quantitative measures included Dice similarity coefficient, recall, precision, Hausdorff distance, 95th percentile of Hausdorff distance, and mean surface distance. Dosimetric differences between the auto-generated contours and manual contours were evaluated. Subjective evaluation was obtained from 3 clinical observers to blindly score the autosegmented structures based on the percentage of slices that require manual modification. Results: The deep-learning-based auto-segmentation versus atlas-based auto-segmentation results were compared for the superior constrictor, middle constrictor, inferior constrictor, and larynx. The mean Dice similarity coefficient values for the 4 structures were 0.67, 0.60, 0.65, and 0.84 for deep-learning-based auto-segmentation, whereas atlas-based auto-segmentation has Dice similarity coefficient results at 0.45, 0.36, 0.50, and 0.70, respectively. The mean 95th percentile of Hausdorff distance (cm) for the 4 structures were 0.41, 0.57, 0.59, and 0.54 for deep-learning-based auto-segmentation, but 0.78, 0.95, 0.96, and 1.23 for atlas-based auto-segmentation results, respectively. Similar mean dose differences were obtained from the 2 sets of autosegmented contours compared to manual contours. The dose-volume discrepancies and the average modification rates were higher with the atlas-based auto-segmentation contours. Conclusion: Swallowing-related structures are more accurately generated with DL-based versus atlas-based segmentation when compared with manual contours.


Assuntos
Neoplasias de Cabeça e Pescoço , Órgãos em Risco , Deglutição , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Estudos Retrospectivos
9.
Exploration (Beijing) ; 2(3): 20210046, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37323701

RESUMO

Heterogeneous catalysis is inseparable from interfacial mass transfer and chemical reaction processes determined by the structure and microenvironment. Different from high-temperature thermochemical processes, photo- and electrocatalysis operated at mild conditions often involve both gas and liquid phases, making it important but challenging to characterize the reaction process typically occurring at the gas-liquid-solid interface. Herein, we review the scope, feasibility, and limitation of ten types of currently available technologies used to characterize interfacial wettability and mass transfer properties of various triple-phase catalytic reactions. The review summarizes techniques from macroscopic contact angle measurement to microscopic environment electron microscopy for investigating the wettability-controlled structure of triple-phase interfaces. Experimental and computational methods in revealing the interfacial mass transfer process have also been systematically discussed, followed by a perspective on the opportunities and challenges of advanced characterization methods to help understand the fundamental reaction mechanism of triple-phase catalysis.

10.
Pract Radiat Oncol ; 11(5): 404-414, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33722783

RESUMO

PURPOSE: This study aimed to evaluate the accuracy of deformable image registration (DIR) algorithms using data sets with different levels of ground-truth deformation vector fields (DVFs) and to investigate the correlation between DVF errors and contour-based metrics. METHODS AND MATERIALS: Nine pairs of digital data sets were generated through contour-controlled deformations based on 3 anonymized patients' CTs (head and neck, thorax/abdomen, and pelvis) with low, medium, and high deformation intensity for each site using the ImSimQA software. Image pairs and their associated contours were imported to MIM-Maestro, Raystation, and Velocity systems, followed by DIR and contour propagation. The system-generated DVF and propagated contours were compared with the ground-truth data. The correlation between DVF errors and contour-based metrics was evaluated using the Pearson correlation coefficient (r), while their correlation with volumes were calculated using Spearman correlation coefficient (rho). RESULTS: The DVF errors increased with increasing deformation intensity. All DIR algorithms performed well for esophagus, trachea, left femoral, right femoral, and urethral (mean and maximum DVF errors <2.50 mm and <4.27 mm, respectively; Dice similarity coefficient: 0.93-0.99). Brain, liver, left lung, and bladder showed large DVF errors for all 3 systems (dmax: 2.8-91.90 mm). The minimum and maximum DVF errors, conformity index, and Dice similarity coefficient were correlated with volumes (|rho|: 0.41-0.64), especially for very large or small structures (|rho|: 0.64-0.80). Only mean distance to agreement of Raystation and Velocity correlated with some indices of DVF errors (r: 0.70-0.78). CONCLUSIONS: Most contour-based metrics had no correlation with DVF errors. For adaptive radiation therapy, well-performed contour propagation does not directly indicate accurate dose deformation and summation/accumulation within each contour (determined by DVF accuracy). Tolerance values for DVF errors should vary as the acceptable accuracy for overall adaptive radiation therapy depends on anatomic site, deformation intensity, organ size, and so forth. This study provides benchmark tables for evaluating DIR accuracy in various clinical scenarios.


Assuntos
Benchmarking , Processamento de Imagem Assistida por Computador , Algoritmos , Cabeça , Humanos , Masculino , Software
11.
Lipids Health Dis ; 19(1): 217, 2020 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-33028331

RESUMO

BACKGROUND: This study explored the relationships between the low-/high-density lipoprotein cholesterol ratio (LDL-C/HDL-C) and other clinical indicators and ischaemic stroke (IS) in patients with non-valvular atrial fibrillation (NVAF) in Xinjiang. The findings could provide a theoretical and therapeutic basis for NVAF patients. METHODS: NVAF patients who were admitted to 10 medical centres across Xinjiang were divided into stroke (798 patients) and control (2671 patients) groups according to the occurrence of first acute IS. Univariate and multivariate logistic regression analysis were used to examine the independent risk factors for IS in NVAF patients. Factor analysis and principal component regression analysis were used to analyse the main factors influencing IS. Receiver operating characteristic (ROC) curve analysis was used to evaluate the discriminatory ability of LDL-C/HDL-C for predicting the occurrence of IS. RESULTS: The stroke group had an average age of 71.64 ± 9.96 years and included 305 females (38.22%). The control group had a mean age of 67.30 ± 12.01 years and included 825 females (30.89%). Multivariate logistic regression showed that the risk of IS in the highest LDL-C/HDL-C quartile (≥2.73) was 16.23-fold that of the lowest quartile (< 1.22); IS risk was 2.27-fold higher in obese patients than in normal-weight subjects; IS risk was 3.15-fold higher in smoking patients than in non-smoking patients. The area under the ROC curve of LDL-C/HDL-C was 0.76, the optimal critical value was 2.33, the sensitivity was 63.53%, and the specificity was 76.34%. Principal component regression analysis showed that LDL-C/HDL-C, age, smoking, drinking, LDL-C and hypertension were risk factors for IS in NVAF patients. CONCLUSIONS: LDL-C/HDL-C > 1.22, smoking, BMI ≥24 kg/m2 and CHA2DS2-VASc score were independent risk factors for IS in NVAF patients; LDL-C/HDL-C was the main risk factor.


Assuntos
Fibrilação Atrial/epidemiologia , AVC Isquêmico/epidemiologia , Obesidade/epidemiologia , Idoso , Fibrilação Atrial/sangue , Fibrilação Atrial/complicações , Fibrilação Atrial/patologia , Estudos de Casos e Controles , HDL-Colesterol/sangue , LDL-Colesterol/sangue , Feminino , Humanos , AVC Isquêmico/sangue , AVC Isquêmico/complicações , AVC Isquêmico/patologia , Masculino , Obesidade/sangue , Obesidade/complicações , Obesidade/patologia , Fatores de Risco
12.
Angew Chem Int Ed Engl ; 59(31): 13057-13062, 2020 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-32342611

RESUMO

Carbon-supported NiII single-atom catalysts with a tetradentate Ni-N2 O2 coordination formed by a Schiff base ligand-mediated pyrolysis strategy are presented. A NiII complex of the Schiff base ligand (R,R)-(-)-N,N'-bis(3,5-di-tert-butylsalicylidene)-1,2-cyclohexanediamine was adsorbed onto a carbon black support, followed by pyrolysis of the modified carbon material at 300 °C in Ar. The Ni-N2 O2 /C catalyst showed excellent performance for the electrocatalytic reduction of O2 to H2 O2 through a two-electron transfer process in alkaline conditions, with a H2 O2 selectivity of 96 %. At a current density of 70 mA cm-2 , a H2 O2 production rate of 5.9 mol gcat. -1 h-1 was achieved using a three-phase flow cell, with good catalyst stability maintained over 8 h of testing. The Ni-N2 O2 /C catalyst could electrocatalytically reduce O2 in air to H2 O2 at a high current density, still affording a high H2 O2 selectivity (>90 %). A precise Ni-N2 O2 coordination was key to the performance.

13.
Front Artif Intell ; 3: 614384, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33733226

RESUMO

Purpose: To assess image quality and uncertainty in organ-at-risk segmentation on cone beam computed tomography (CBCT) enhanced by deep-learning convolutional neural network (DCNN) for head and neck cancer. Methods: An in-house DCNN was trained using forty post-operative head and neck cancer patients with their planning CT and first-fraction CBCT images. Additional fifteen patients with repeat simulation CT (rCT) and CBCT scan taken on the same day (oCBCT) were used for validation and clinical utility assessment. Enhanced CBCT (eCBCT) images were generated from the oCBCT using the in-house DCNN. Quantitative imaging quality improvement was evaluated using HU accuracy, signal-to-noise-ratio (SNR), and structural similarity index measure (SSIM). Organs-at-risk (OARs) were delineated on o/eCBCT and compared with manual structures on the same day rCT. Contour accuracy was assessed using dice similarity coefficient (DSC), Hausdorff distance (HD), and center of mass (COM) displacement. Qualitative assessment of users' confidence in manual segmenting OARs was performed on both eCBCT and oCBCT by visual scoring. Results: eCBCT organs-at-risk had significant improvement on mean pixel values, SNR (p < 0.05), and SSIM (p < 0.05) compared to oCBCT images. Mean DSC of eCBCT-to-rCT (0.83 ± 0.06) was higher than oCBCT-to-rCT (0.70 ± 0.13). Improvement was observed for mean HD of eCBCT-to-rCT (0.42 ± 0.13 cm) vs. oCBCT-to-rCT (0.72 ± 0.25 cm). Mean COM was less for eCBCT-to-rCT (0.28 ± 0.19 cm) comparing to oCBCT-to-rCT (0.44 ± 0.22 cm). Visual scores showed OAR segmentation was more accessible on eCBCT than oCBCT images. Conclusion: DCNN improved fast-scan low-dose CBCT in terms of the HU accuracy, image contrast, and OAR delineation accuracy, presenting potential of eCBCT for adaptive radiotherapy.

14.
Phys Med Biol ; 65(3): 035003, 2020 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-31842014

RESUMO

To improve image quality and CT number accuracy of fast-scan low-dose cone-beam computed tomography (CBCT) through a deep-learning convolutional neural network (CNN) methodology for head-and-neck (HN) radiotherapy. Fifty-five paired CBCT and CT images from HN patients were retrospectively analysed. Among them, 15 patients underwent adaptive replanning during treatment, thus had same-day CT/CBCT pairs. The remaining 40 patients (post-operative) had paired planning CT and 1st fraction CBCT images with minimal anatomic changes. A 2D U-Net architecture with 27-layers in 5 depths was built for the CNN. CNN training was performed using data from 40 post-operative HN patients with 2080 paired CT/CBCT slices. Validation and test datasets include 5 same-day datasets with 260 slice pairs and 10 same-day datasets with 520 slice pairs, respectively. To examine the impact of differences in training dataset selection and network performance as a function of training data size, additional networks were trained using 30, 40 and 50 datasets. Image quality of enhanced CBCT images were quantitatively compared against the CT image using mean absolute error (MAE) of Hounsfield units (HU), signal-to-noise ratio (SNR) and structural similarity (SSIM). Enhanced CBCT images reduced artifact distortion and improved soft tissue contrast. Networks trained with 40 datasets had imaging performance comparable to those trained with 50 datasets and outperformed those trained with 30 datasets. Comparison of CBCT and enhanced CBCT images demonstrated improvement in average MAE from 172.73 to 49.28 HU, SNR from 8.27 to 14.25 dB, and SSIM from 0.42 to 0.85. The image processing time is 2 s per patient using a NVIDIA GeForce GTX 1080 Ti GPU. The proposed deep-leaning methodology was fast and effective for image quality enhancement of fast-scan low-dose CBCT. This method has potential to support fast online-adaptive re-planning for HN cancer patients.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/radioterapia , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Redes Neurais de Computação , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Estudos Retrospectivos , Razão Sinal-Ruído
15.
Angew Chem Int Ed Engl ; 58(36): 12624-12631, 2019 09 02.
Artigo em Inglês | MEDLINE | ID: mdl-31237404

RESUMO

Nanozymes have attracted extensive interest owing to their high stability, low cost and easy preparation, especially in the field of cancer therapy. However, the relatively low catalytic activity of nanozymes in the tumor microenvironment (TME) has limited their applications. Herein, we report a novel nanozyme (PtFe@Fe3 O4 ) with dual enzyme-like activities for highly efficient tumor catalytic therapy. PtFe@Fe3 O4 shows the intrinsic photothermal effect as well as photo-enhanced peroxidase-like and catalase-like activities in the acidic TME, thereby effectively killing tumor cells and overcoming the tumor hypoxia. Importantly, a possible photo-enhanced synergistic catalytic mechanism of PtFe@Fe3 O4 was first disclosed. We believe that this work will advance the development of nanozymes in tumor catalytic therapy.


Assuntos
Catalase/metabolismo , Nanopartículas Metálicas/uso terapêutico , Neoplasias Pancreáticas/terapia , Peroxidase/metabolismo , Animais , Apoptose , Catálise , Proliferação de Células , Humanos , Masculino , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Nus , Neoplasias Pancreáticas/enzimologia , Neoplasias Pancreáticas/patologia , Células Tumorais Cultivadas , Hipóxia Tumoral , Microambiente Tumoral , Ensaios Antitumorais Modelo de Xenoenxerto
16.
Adv Mater ; 31(18): e1900509, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30873691

RESUMO

The selective hydrogenation of acetylene to ethylene in an ethylene-rich gas stream is an important process in the chemical industry. Pd-based catalysts are widely used in this reaction due to their excellent hydrogenation activity, though their selectivity for acetylene hydrogenation and durability need improvement. Herein, the successful synthesis of atomically dispersed Pd single-atom catalysts on nitrogen-doped graphene (Pd1 /N-graphene) by a freeze-drying-assisted method is reported. The Pd1 /N-graphene catalyst exhibits outstanding activity and selectivity for the hydrogenation of C2 H2 with H2 in the presence of excess C2 H4 under photothermal heating (UV and visible-light irradiation from a Xe lamp), achieving 99% conversion of acetylene and 93.5% selectivity to ethylene at 125 °C. This remarkable catalytic performance is attributed to the high concentration of Pd active sites on the catalyst surface and the weak adsorption energy of ethylene on isolated Pd atoms, which prevents C2 H4 hydrogenation. Importantly, the Pd1 /N-graphene catalyst exhibits excellent durability at the optimal reaction temperature of 125 °C, which is explained by the strong local coordination of Pd atoms by nitrogen atoms, which suppresses the Pd aggregation. The results presented here encourage the wider pursuit of solar-driven photothermal catalyst systems based on single-atom active sites for selective hydrogenation reactions.

17.
Front Biosci (Landmark Ed) ; 22(4): 570-579, 2017 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-27814633

RESUMO

Contemporary radiotherapy (RT) planning utilizes both a computed tomography (CT) scan either in prone or supine position with no breast compression or magnetic resonance imaging (MRI). The application of MRI is limited by image distortion and a lack of electron density information. The standard supine position not only exposes the tumor to RT non-homogenously, it can cause damage to the neighboring benign tissues. Here, we compare the effectiveness of both the prone and supine positions in breast cancer RT and various aspects of breast cancer treatment planning using MRI and CT.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/radioterapia , Imageamento por Ressonância Magnética/métodos , Feminino , Humanos , Decúbito Ventral , Planejamento da Radioterapia Assistida por Computador , Decúbito Dorsal , Tomografia Computadorizada por Raios X
18.
Chem Commun (Camb) ; 51(63): 12556-9, 2015 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-26152850

RESUMO

A copper(i) cysteine complex generated by mixing Cu(ii) ions with cysteine in aqueous solution greatly enhanced the activity of CdSe photocatalysts for H2 production in aqueous solution under visible light excitation. The complex can enhance the H2 evolution rate by as much as 150 times, by acting as an oxidation co-catalyst and increasing charge carrier lifetimes. The copper(i) cysteine complex can also be applied to enhance the H2 production performance of other semiconductor photocatalyst systems, thereby affording a new research direction in the development of co-catalysts for solar hydrogen production.


Assuntos
Complexos de Coordenação/química , Cobre/química , Cisteína/química , Hidrogênio/química , Luz , Compostos de Cádmio/química , Catálise , Hidrogênio/metabolismo , Oxirredução , Compostos de Selênio/química , Semicondutores , Energia Solar , Água/química
19.
Expert Rev Anticancer Ther ; 15(7): 765-76, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25955383

RESUMO

Non-melanoma skin cancer is the most common malignancy in the USA, with an estimated 3.5 million cases per year. Treatment options include surgical excision, radiation therapy (RT), photodynamic therapy and topical agents. Although surgical excision remains the mainstay of therapy, RT offers an effective alternative. RT can be used as an adjunct to surgery in high-risk situations, or in cases where surgical excision would lead to impaired cosmesis and/or functional outcomes. Radiation treatment modalities for non-melanoma skin cancers are diverse. Studies in the literature have examined the clinical effects of a wide variety of modalities, areas of the body and dosages. The most common modalities include superficial or orthovoltage RT, electron beam therapy and high dose-rate brachytherapy. This article aims to review the diverse radiotherapy treatment modalities for non-melanoma skin cancers, focusing on tumor control and toxicity.


Assuntos
Radioterapia/métodos , Neoplasias Cutâneas/radioterapia , Braquiterapia/métodos , Humanos , Melanoma , Radioterapia/efeitos adversos
20.
Med Phys ; 41(5): 051709, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24784375

RESUMO

PURPOSE: Despite superior target dose uniformity, helical tomotherapy(®) (HT) may involve a trade-off between longitudinal dose conformity and beam-on time (BOT), due to the limitation of only three available jaw sizes with the conventional HT (1.0, 2.5, and 5.0 cm). The recently introduced dynamic running-start-stop (RSS) delivery allows smaller jaw opening at the superior and inferior ends of the target when a sharp penumbra is needed. This study compared the dosimetric performance of RSS delivery with the fixed jaw HT delivery. METHODS: Twenty patient cases were selected and deidentified prior to treatment planning, including 16 common clinical cases (brain, head and neck (HN), lung, and prostate) and four special cases of whole brain with hippocampus avoidance (WBHA) that require a high degree of dose modulation. HT plans were generated for common clinical cases using the fixed 2.5 cm jaw width (HT2.5) and WBHA cases using 1.0 cm (HT1.0). The jaw widths for RSS were preset with a larger size (RSS5.0 vs HT2.5 and RSS2.5 vs HT1.0). Both delivery techniques were planned based on identical contours, prescriptions, and planning objectives. Dose indices for targets and critical organs were compared using dose-volume histograms, BOT, and monitor units. RESULTS: The average BOT was reduced from 4.8 min with HT2.5 to 2.5 min with RSS5.0. Target dose homogeneity with RSS5.0 was shown comparable to HT2.5 for common clinical sites. Superior normal tissue sparing was observed in RSS5.0 for optic nerves and optic chiasm in brain and HN cases. RSS5.0 demonstrated improved dose sparing for cord and esophagus in lung cases, as well as penile bulb in prostate cases. The mean body dose was comparable for both techniques. For the WBHA cases, the target homogeneity was significantly degraded in RSS2.5 without distinct dose sparing for hippocampus, compared to HT1.0. CONCLUSIONS: Compared to the fixed jaw HT delivery, RSS combined with a larger jaw width provides faster treatment delivery and improved cranial-caudal target dose conformity. The target coverage achieved by RSS with a large jaw width is comparable to the fixed jaw HT delivery for common cancer sites, but may deteriorate for cases where complex geometry is present in the middle part of the target.


Assuntos
Radioterapia de Intensidade Modulada/instrumentação , Radioterapia de Intensidade Modulada/métodos , Neoplasias Encefálicas/radioterapia , Neoplasias de Cabeça e Pescoço/radioterapia , Humanos , Neoplasias Pulmonares/radioterapia , Masculino , Neoplasias da Próstata/radioterapia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA