Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 14(1): 9529, 2024 04 25.
Artigo em Inglês | MEDLINE | ID: mdl-38664433

RESUMO

The aim of this study was to develop a dynamic nomogram combining clinical and imaging data to predict malignant brain edema (MBE) after endovascular thrombectomy (EVT) in patients with large vessel occlusion stroke (LVOS). We analyzed the data of LVOS patients receiving EVT at our center from October 2018 to February 2023, and divided a 7:3 ratio into the training cohort and internal validation cohort, and we also prospectively collected patients from another stroke center for external validation. MBE was defined as a midline shift or pineal gland shift > 5 mm, as determined by computed tomography (CT) scans obtained within 7 days after EVT. A nomogram was constructed using logistic regression analysis, and its receiver operating characteristic curve (ROC) and calibration were assessed in three cohorts. A total of 432 patients were enrolled in this study, with 247 in the training cohort, 100 in the internal validation cohort, and 85 in the external validation cohort. MBE occurred in 24% (59) in the training cohort, 16% (16) in the internal validation cohort and 14% (12) in the external validation cohort. After adjusting for various confounding factors, we constructed a nomogram including the clot burden score (CBS), baseline neutrophil count, core infarct volume on CTP before EVT, collateral index, and the number of retrieval attempts. The AUCs of the training cohorts were 0.891 (95% CI 0.840-0.942), the Hosmer-Lemeshow test showed good calibration of the nomogram (P = 0.879). And our nomogram performed well in both internal and external validation data. Our nomogram demonstrates promising potential in identifying patients at elevated risk of MBE following EVT for LVOS.


Assuntos
Edema Encefálico , Procedimentos Endovasculares , AVC Isquêmico , Nomogramas , Trombectomia , Humanos , Masculino , Feminino , Trombectomia/efeitos adversos , Trombectomia/métodos , Idoso , Edema Encefálico/etiologia , Edema Encefálico/diagnóstico por imagem , AVC Isquêmico/cirurgia , AVC Isquêmico/etiologia , AVC Isquêmico/diagnóstico por imagem , Pessoa de Meia-Idade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Fatores de Risco , Curva ROC , Idoso de 80 Anos ou mais , Tomografia Computadorizada por Raios X
2.
J Neuroimaging ; 34(2): 241-248, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38018876

RESUMO

BACKGROUND AND PURPOSE: Parenchymal hematoma is a dreaded complication of mechanical thrombectomy after acute ischemic stroke. This study evaluated whether blood-brain barrier permeability measurements based on CT perfusion could be used as predictors of parenchymal hematoma after successful recanalization and compared the predictive value of various permeability parameters in patients with acute ischemic stroke. METHODS: We enrolled 53 patients with acute ischemic stroke who underwent mechanical thrombectomy and achieved successful recanalization. Each patient underwent CT, CT angiography, and CT perfusion imaging before treatment. We used relative volume transfer constant (rKtrans ) values, relative permeability-surface area product (rP·S), and relative extraction fraction (rE) to evaluate preoperative blood-brain barrier permeability in the delayed perfusion area. RESULTS: Overall, 22 patients (37.7%) developed hemorrhagic transformation after surgery, including 10 patients (16.9%) with hemorrhagic infarction and 11 patients (20.8%) with parenchymal hematoma. The rP·S, rKtrans , and rE of the hypoperfusion area in the parenchymal hematoma group were significantly higher than those in the hemorrhagic infarction and no-hemorrhage transformation groups (p < .01). We found that rE and rP·S were superior to rKtrans in predicting parenchymal hematoma transformation after thrombectomy (P·S area under the curve [AUC] .844 vs. rKtrans AUC .753, z = 2.064, p = .039; rE AUC .907 vs. rKtrans AUC .753, z = 2.399, p = .017). CONCLUSIONS: Patients with parenchymal hematoma after mechanical thrombectomy had higher blood-brain barrier permeability in hypoperfusion areas. Among blood-brain barrier permeability measurement parameters, rP·S and rE showed better accuracy for parenchymal hematoma prediction.


Assuntos
Isquemia Encefálica , AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Barreira Hematoencefálica/diagnóstico por imagem , Acidente Vascular Cerebral/cirurgia , AVC Isquêmico/complicações , Trombectomia/efeitos adversos , Tomografia Computadorizada por Raios X/métodos , Hematoma/diagnóstico por imagem , Hematoma/cirurgia , Infarto/complicações , Permeabilidade , Isquemia Encefálica/cirurgia , Hemorragia Cerebral/diagnóstico por imagem , Hemorragia Cerebral/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
3.
CNS Neurosci Ther ; 30(4): e14513, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-37953498

RESUMO

OBJECTIVE: To explore the relationship between asymmetric deep cerebral venous (ADCV) filling and poor outcomes after endovascular treatment (EVT) in patients with acute basilar artery occlusion (ABAO). METHODS: ABAO patients were selected from a prospectively collected data at our center. The DCV filling was evaluated using computed tomography perfusion (CTP)-derived reconstructed 4D-DSA or mean venous map. ADCV filling was defined as the internal cerebral vein (ICV), thalamostriate vein (TSV), or basal vein of Rosenthal (BVR) presence of ipsilateral filling defects or delayed opacification compared to the contralateral side. Poor prognosis was defined as a modified Rankin scale score >3 at the 90-day follow-up. RESULTS: A total of 90 patients were enrolled in the study, with a median Glasgow Coma Scale of 6, 46 (51.1%) showed ADCV filling, 59 (65.6%) had a poor prognosis, and 27 (30.7%) had malignant cerebellar edema (MCE). Multivariate adjusted analysis revealed significant associations between asymmetric TSV and poor prognosis (odds ratio, 9.091, p = 0.006); asymmetric BVR (OR, 9.232, p = 0.001) and asymmetric ICV (OR, 4.028, p = 0.041) were significantly associated with MCE. CONCLUSION: Preoperative ADCV filling is an independent influencing factor for the poor outcome after EVT in ABAO patients.


Assuntos
Arteriopatias Oclusivas , Edema Encefálico , Veias Cerebrais , Procedimentos Endovasculares , Acidente Vascular Cerebral , Humanos , Artéria Basilar/cirurgia , Arteriopatias Oclusivas/patologia , Arteriopatias Oclusivas/cirurgia , Terapia Trombolítica/métodos , Trombectomia/métodos , Veias Cerebrais/diagnóstico por imagem , Veias Cerebrais/patologia , Edema Encefálico/patologia , Procedimentos Endovasculares/métodos , Resultado do Tratamento , Acidente Vascular Cerebral/patologia , Estudos Retrospectivos
4.
BMC Med Inform Decis Mak ; 22(1): 319, 2022 12 07.
Artigo em Inglês | MEDLINE | ID: mdl-36476365

RESUMO

PURPOSE: Diagnostic statements for pituitary adenomas (PAs) are complex and unstandardized. We aimed to determine the most commonly used elements contained in the statements and their combination patterns and variations in real-world clinical practice, with the ultimate goal of promoting standardized diagnostic recording and establishing an efficient element extraction process. METHODS: Patient medical records from 2012 to 2020 that included PA among the first three diagnoses were included. After manually labeling the elements in the diagnostic texts, we obtained element types and training sets, according to which an information extraction model was constructed based on the word segmentation model "Jieba" to extract information contained in the remaining diagnostic texts. RESULTS: A total of 576 different diagnostic statements from 4010 texts of 3770 medical records were enrolled in the analysis. The first ten diagnostic elements related to PA were histopathology, tumor location, endocrine status, tumor size, invasiveness, recurrence, diagnostic confirmation, Knosp grade, residual tumor, and refractoriness. The automated extraction model achieved F1-scores that reached 100% for all ten elements in the second round and 97.3-100.0% in the test set consisting of an additional 532 diagnostic texts. Tumor location, endocrine status, histopathology, and tumor size were the most commonly used elements, and diagnoses composed of the above elements were the most frequent. Endocrine status had the greatest expression variability, followed by Knosp grade. Among all the terms, the percentage of loss of tumor size was among the highest (21%). Among statements where the principal diagnoses were PAs, 18.6% did not have information on tumor size, while for those with other diagnoses, this percentage rose to 48% (P < 0.001). CONCLUSION: Standardization of the diagnostic statement for PAs is unsatisfactory in real-world clinical practice. This study could help standardize a structured pattern for PA diagnosis and establish a foundation for research-friendly, high-quality clinical information extraction.


Assuntos
Neoplasias Hipofisárias , Humanos , Neoplasias Hipofisárias/diagnóstico , Registros Eletrônicos de Saúde , Armazenamento e Recuperação da Informação
5.
Innov Clin Neurosci ; 18(7-9): 47-49, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34980994

RESUMO

The pathogenesis of schizophrenia is rarely attributed to dysfunction of the cerebellum. However, coordination of mental processes might involve the cerebellum and a cortico-cerebellar-thalamic-cortical circuit (CCTCC) that can mediate that process has been proposed. We present the case of a 31-year-old male patient with a family history of psychosis who developed schizophrenia in association with a slow-growing glioblastoma at the left posterior cerebellar pontine angle. Of interest is that his psychosis became refractory after surgical removal of the tumor that had no motor deficit consequences, suggesting that the greater disruption of the CCTCC due to surgical excision might be related to the worsening psychosis. The case supports the hypothesis of cognitive dysmetria and psychosis.

6.
J Surg Res ; 239: 166-172, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30836298

RESUMO

BACKGROUND: To study the feasibility of laparo-endoscopic single-site (LESS) cholecystectomy through a 10-mm incision using a miniature magnetically anchored and controlled laparoscopy system and a grasper system. METHODS: The miniature magnetically anchored and controlled laparoscopy system consisted of a miniature magnetically anchored camera (MMAC), an external magnetic anchoring unit, and a vision output device. The camera weighed 9.8 g and measured Φ10 mm × 50 mm. The magnetically anchored and controlled grasper system consisted of a magnetically anchored grasper (MAG), an external magnetic anchoring unit, and a push-pull device. The MAG had a titanium alloy clip head and a magnetic tail. The laparoscopy system and grasper system were used simultaneously to perform LESS cholecystectomy through a single 10-mm incision in model canines. RESULTS: LESS cholecystectomy through a 10-mm incision using the MMAC and MAG was attempted in six dogs. The mean operative time was 85.75 ± 7.14 min. The operation was completed successfully in four cases, with failure occurring in one case due to gallbladder rupture and in another due to bile duct injury. The MMAC provided clear imaging, and the MAG provided sufficient exposure to perform the cholecystectomy. The use of multiple magnetically anchored and controlled instruments did not result in notable collisions. CONCLUSIONS: The designed MMAC and MAG system could be easily maneuvered. LESS cholecystectomy may be feasible through a single 10-mm incision with the simultaneous use of multiple magnetically anchored and controlled instruments.


Assuntos
Colecistectomia Laparoscópica/instrumentação , Doenças da Vesícula Biliar/cirurgia , Imãs , Cirurgia Vídeoassistida/instrumentação , Animais , Ductos Biliares/lesões , Colecistectomia Laparoscópica/efeitos adversos , Colecistectomia Laparoscópica/métodos , Cães , Desenho de Equipamento , Estudos de Viabilidade , Vesícula Biliar/lesões , Vesícula Biliar/cirurgia , Humanos , Modelos Animais , Duração da Cirurgia , Complicações Pós-Operatórias/etiologia , Ruptura/etiologia , Cirurgia Vídeoassistida/efeitos adversos , Cirurgia Vídeoassistida/métodos
7.
Surg Endosc ; 31(1): 274-280, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27177955

RESUMO

BACKGROUND: Laparoendoscopic single-site surgery and natural orifice transluminal endoscopic surgery attempt to reduce transabdominal port sites. These require all instruments to pass through a single access point, leading to instruments collide or work at unfamiliar angles. Thus, we designed an internal grasper under magnetic anchoring guide system (MAGS) platform and investigated its utility and operability. METHODS: We measured the configuration for magnetic force decay over distance using a standardized, ex vivo laboratory testing apparatus. An electronic balance was used to measure the force of the gallbladder pull in ten patients with gallbladder stones. One pig (11 mm abdominal wall thickness) underwent a compressed trial of MAGS platform. The device was left in place for 20 min before tissue sections were harvested, and histologic assessment was performed. The utility and operability were investigated in four pigs (38-280 kg weight). RESULTS: The magnetic attraction force decayed exponentially over distance; the force of pulling gallbladder was 7.46 ± 0.54 N. This pairing of components allowed for coupling to a theoretical distance of 10 mm. No gross tissue damage was observed. H-E stain showed no necrosis in all specimens. One failed due to wall thickness of 45 mm. Others showed the critical view, triangulation of instruments was obtained, and instrument collision or "sword fighting" was reduced. CONCLUSIONS: The MAGS platform overcomes limitations such as collisions and lack of triangulation, reduces transabdominal port sites, and is easy to operate. However, our internal grasper requires the abdominal wall thickness below 10 mm.


Assuntos
Laparoscopia , Magnetismo/instrumentação , Animais , Desenho de Equipamento , Modelos Animais , Instrumentos Cirúrgicos , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA