Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Sci Total Environ ; 927: 172315, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38593874

RESUMO

The valorization of electroplating sludge (ES) for high added value presents greater economic and environmental benefits than conventional treatment methods such as thermal processing, solidification, and landfill. Inspired by the mechanism of chemical looping combustion (CLC), this study developed a novel cost-effective method for denitrification by preparing FeNi-OCs from ES to achieve the synergistic reduction of CO and NO emissions. The phase structure, micromorphology, and valence state changes of the FeNi-OC catalyst during the CO-catalyzed reduction of NO and the pathway for catalytic denitrification using FeNi-OCs were analyzed. Results showed that CO could reduce FeNi-OCs to FeNi, and the reduced FeNi was subsequently oxidized back to FeNi-OCs by NO, a process analogous to CLC. During experiments, the simultaneous consumption of CO and NO gases was observed at 350 °C. This phenomenon was highly pronounced at 600 °C, where the CO and NO concentrations decreased from initial values of 8550 and 470 ppm, respectively, to 6719 and 0 ppm, respectively, with conversion rates of 21.41 % and 100 %, respectively. Hence, synergistic emission reduction was achieved. Further experiments also indicated that the addition of 1.5 % ES during iron ore sintering could substantially reduce the CO and NO concentrations in the sintering flue gas from 1268.32 and 244.81 ppm, respectively, to 974.51 and 161.11 ppm, respectively.

2.
Pharmacol Res ; 159: 104987, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32512044

RESUMO

In the present study, the concentrations of lead (Pb), cadmium (Cd), arsenic (As), mercury (Hg), and copper (Cu) in 2245 batches of Chinese herbal medicines (CHMs) were measured using inductively coupled plasma-mass spectroscopy (ICP-MS). We developed a risk assessment strategy that assessed the heavy metal-associated health risk of CHMs based on our large dataset. Using a combination of the mean and 95th percentile (P95) values of the chronic daily intake (CDI), hazard quotient (HQ), hazard index (HI), and lifetime cancer risk (CR), the health risks of the average exposure population and the high exposure population were estimated, respectively. To obtain a precise and realistic risk assessment, the exposure frequency and exposure duration were determined using questionnaire data from 20,917 randomly selected volunteers. Additionally, given the specific ingestion characteristics of CHMs, the safety factor and the transfer rates of heavy metals were highlighted as well. The concentrations of Pb, Cd, As, Hg, and Cu in 2245 batches of CHMs were 1.566, 0.299, 0.391, 0.074, and 8.386 mg/kg, respectively. The mean HI values indicated that consumption of most CHMs would not pose an unacceptable health risk to the average exposure population, except for argy wormwood leaf (1.326), morinda root (2.095), plantain herb (1.540), chrysanthemum flower (1.146), and Indian madder root (2.826). In addition, CR assessment for Pb and As revealed that, for the average exposure population, the risk of developing cancers was lower than the acceptable levels (1 × 10-4) in the clinic. However, the P95 of the HI and CR values indicated that more attention should be paid to the systemic effects of CHMs in terms of both non-carcinogenic and carcinogenic health risks for the high exposure population. Furthermore, in order to serve population health better, national and international guidelines have now been established. The risk assessment strategy developed in this study is the first of its kind, and contributed to the risk assessment, guidelines, and safety standards for heavy metals in CHMs.


Assuntos
Contaminação de Medicamentos , Medicamentos de Ervas Chinesas/análise , Metais Pesados/análise , Adolescente , Adulto , Qualidade de Produtos para o Consumidor , Medicamentos de Ervas Chinesas/efeitos adversos , Feminino , Humanos , Masculino , Espectrometria de Massas , Metais Pesados/efeitos adversos , Pessoa de Meia-Idade , Segurança do Paciente , Controle de Qualidade , Medição de Risco , Fatores de Risco , Inquéritos e Questionários , Adulto Jovem
3.
Biomed Chromatogr ; 28(12): 1869-73, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24897932

RESUMO

A highly sensitive, rapid assay method has been developed and validated for the analysis of polyphyllin H in beagle dog plasma with liquid chromatography coupled to tandem mass spectrometry with electrospray ionization in the positive-ion mode. The assay procedure involves extraction of polyphyllin H and ginsenoside Re (IS) from beagle dog plasma. Chromatographic separation was carried out on an Agilent Zorbax XDB-C18 (100 × 2.1 mm, 1.8µm) column by isocratic elution with acetonitrile and water (50:50, v/v) at a flow rate of 0.25 mL/min with a total run time of 2.5 min. The MS/MS ion transitions monitored were m/z 869.60 → 869.60 for polyphyllin H and m/z 969.60 → 969.60 for IS. [corrected] Linear responses were obtained for polyphyllin H ranging from 1 to 50 ng/mL. The intra-and inter-day precisions (RSDs) <1.77 and 3.39% and the extraction recovery ranged from 91.89 to 93.33% with RSD <2.68%. Stability studies showed that polyphyllin H was stable in the preparation and analytical process. The results indicated that the validated method was successfully used to determine the concentration-time profiles of polyphyllin H.


Assuntos
Cromatografia Líquida/métodos , Cromonas/sangue , Cromonas/farmacocinética , Medicamentos de Ervas Chinesas/análise , Medicamentos de Ervas Chinesas/farmacocinética , Glicosídeos/sangue , Glicosídeos/farmacocinética , Magnoliopsida/química , Espectrometria de Massas em Tandem/métodos , Administração Oral , Animais , Cromonas/administração & dosagem , Cromonas/química , Cães , Medicamentos de Ervas Chinesas/administração & dosagem , Medicamentos de Ervas Chinesas/química , Ginsenosídeos , Glicosídeos/administração & dosagem , Glicosídeos/química , Modelos Lineares , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA