Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Arthroscopy ; 2024 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-38311265

RESUMO

PURPOSE: To investigate whether allograft substitutes may be used to restore suctional seal properties with labral augmentation, the purpose of the current study was to evaluate the biomechanical properties of the labral suction seal under several scenarios, including: (1) intact labrum, (2) rim preparation, (3) labral repair, (4) labral augmentation with iliotibial band (ITB), and (5) labral augmentation with a dermis allograft. METHODS: Eleven hemi-pelvises were dissected to the level of the labrum and placed in a material testing system for biomechanical axial distraction. Each specimen was compressed to 250 newtons (N) and distracted at 10 mm/s while load, crosshead displacement, and time were continuously recorded. For each of the 5 labral states, 3 testing repetitions were performed. Peak force (N, newtons), displacement at peak force (mm, millimeter), and work (N-mm, newton, millimeter) were calculated and normalized to the intact state of each specimen. RESULTS: Eleven specimens were tested and 8 specimens (age: 58.6 ± 5.4 years, body mass index: 28.6 ± 6.8 kg/m2; 4 female patients; 5 right hips) were included in final analyses. Expressed as a percentage relative to the intact state, the average normalized peak force, displacement at peak force, and work for each labral state were as follows: intact (100.0% ± 0% for all), rim preparation (89.0% ± 9.2%, 93.3% ± 20.6%, 85.1% ± 9.0%), repair (61.3% ± 17.9%, 88.4% ± 36.9%, 58.1% ± 16.7%), ITB allograft (62.7% ± 24.9%, 83.9% ± 21.6%, 59.4% ± 22.4%), and dermis allograft (57.8% ± 27.2%, 88.2% ± 29.5%, 50.0% ± 20.1%). Regarding peak force, intact state was significantly greater compared with the labral repair, augmentation with ITB, and augmentation with the dermis allograft states (P < .001). No significant differences were demonstrated between displacement at peak force (P = .561). Regarding work, both intact state and rim preparation states were significantly greater than the repair, ITB augmentation, and dermis allograft augmentation states (P < .001). In all outcome measures, the dermis allograft augmentation performed with no statistical difference to the ITB augmentation state. CONCLUSIONS: Labral repair and labral augmentation with either ITB allograft or the dermis allograft resulted in significantly lower peak force and work to equilibrium compared with the intact and rim prep states. There was no statistical difference between repair and augmentation states as well as no statistical difference between ITB allograft and dermal allograft at time zero. CLINICAL RELEVANCE: This study compares biomechanical properties of the suction seal of the hip comparing labral states including intact, rim preparation, repair, and augmentation, which can be used for surgical decision-making.

2.
Arthroscopy ; 39(8): 1827-1837.e2, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36813008

RESUMO

PURPOSE: To quantify the effects that posterior meniscofemoral ligament (pMFL) lesions have on lateral meniscal extrusion (ME) both with and without concomitant posterior lateral meniscal root (PLMR) tears and describe how lateral ME varied along the length of the lateral meniscus. METHODS: Ultrasonography was used to measure ME of human cadaveric knees (n = 10) under the following conditions: control, isolated pMFL sectioning, isolated PLMR sectioning, pMFL+PLMR sectioning, and PLMR repair. ME was measured anterior to the fibular collateral ligament (FCL), at the FCL, and posterior to the FCL in both unloaded and axially loaded states at 0° and 30° of flexion. RESULTS: Isolated and combined pMFL and PLMR sectioning consistently demonstrated significantly greater ME when measured posterior to the FCL compared with other image locations. Isolated pMFL tears demonstrated greater ME at 0° compared with 30° of flexion (P < .05), whereas isolated PLMR tears demonstrated greater ME at 30° compared with 0° of flexion (P < .001). All specimens with isolated PLMR deficiencies demonstrated greater than 2 mm of ME at 30° flexion, whereas only 20% of specimens did so at 0°. When the pMFL was sectioned following an isolated PLMR tear, there was a significant increase in ME at 0° (P < .001). PLMR repair after combined sectioning restored ME to levels similar to that of controls in all specimens when measured at and posterior to the FCL (P < .001). CONCLUSIONS: The pMFL protects against ME primarily in full extension, whereas the presence of ME in the setting of PLMR injuries may be better appreciated in knee flexion. With combined tears, isolated repair of the PLMR can restore near-native meniscus position. CLINICAL RELEVANCE: The stabilizing properties of intact pMFL may mask the presentation of PLMR tears and delay appropriate management. Additionally, the MFL is not routinely assessed during arthroscopy due to difficult visualization and access. Understanding the ME pattern of these pathologies in isolation and combination may improve detection rates so that the source of patients' symptoms can be addressed to satisfaction.


Assuntos
Lesões do Ligamento Cruzado Anterior , Lesões do Menisco Tibial , Humanos , Meniscos Tibiais/diagnóstico por imagem , Tíbia , Lesões do Ligamento Cruzado Anterior/complicações , Lesões do Menisco Tibial/diagnóstico por imagem , Lesões do Menisco Tibial/cirurgia , Lesões do Menisco Tibial/complicações , Fenômenos Biomecânicos , Cadáver , Articulação do Joelho/diagnóstico por imagem , Ligamentos Articulares/diagnóstico por imagem , Ultrassonografia
3.
Arthroscopy ; 39(8): 1815-1826.e1, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36813009

RESUMO

PURPOSE: To evaluate how the meniscotibial ligament (MTL) affects meniscal extrusion (ME) with or without concomitant posterior medial meniscal root (PMMR) tears and to describe how ME varied along the length of meniscus. METHODS: ME was measured using ultrasonography in 10 human cadaveric knees in conditions: (1) control, either (2a) isolated MTL sectioning, or (2b) isolated PMMR tear, (3) combined PMMR+MTL sectioning, and (4) PMMR repair. Measurements were obtained 1 cm anterior to the MCL (anterior), over the MCL (middle), and 1 cm posterior to the MCL (posterior) with or without 1,000 N axial loads in 0° and 30° flexion. RESULTS: At 0°, MTL sectioning demonstrated greater middle than anterior (P < .001) and posterior (P < .001) ME, whereas PMMR (P = .0042) and PMMR+MTL (P < .001) sectioning demonstrated greater posterior than anterior ME. At 30°, PMMR (P < .001) and PMMR+MTL (P < .001) sectioning demonstrated greater posterior than anterior ME, and PMMR (P = .0012) and PMMR+MTL (P = .0058) sectioning demonstrated greater posterior than anterior ME. PMMR+MTL sectioning demonstrated greater posterior ME at 30° compared with 0° (P = .0320). MTL sectioning always resulted in greater middle ME (P < .001), in contrast with no middle ME changes following PMMR sectioning. At 0°, PMMR sectioning resulted in greater posterior ME (P < .001), but at 30°, both PMMR and MTL sectioning resulted in greater posterior ME (P < .001). Total ME surpassed 3 mm only when both the MTL and PMMR were sectioned. CONCLUSIONS: The MTL and PMMR contribute most to ME when measured posterior to the MCL at 30° of flexion. ME greater than 3 mm is suggestive of combined PMMR + MTL lesions. CLINICAL RELEVANCE: Overlooked MTL pathology may contribute to persistent ME following PMMR repair. We found isolated MTL tears able to cause 2 to 2.99 mm of ME, but the clinical significance of these magnitudes of extrusion is unclear. The use of ME measurement guidelines with ultrasound may allow for practical MTL and PMMR pathology screening and pre-operative planning.


Assuntos
Lesões do Ligamento Cruzado Anterior , Doenças das Cartilagens , Traumatismos do Joelho , Lesões do Menisco Tibial , Humanos , Lesões do Menisco Tibial/diagnóstico por imagem , Lesões do Menisco Tibial/cirurgia , Fenômenos Biomecânicos , Cadáver , Articulação do Joelho/cirurgia , Meniscos Tibiais/diagnóstico por imagem , Meniscos Tibiais/cirurgia , Ligamento Cruzado Anterior/cirurgia , Traumatismos do Joelho/cirurgia , Ultrassonografia , Lesões do Ligamento Cruzado Anterior/cirurgia
4.
J Knee Surg ; 36(6): 622-630, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-35144302

RESUMO

The purpose of this study was to investigate whether differences exist in preventing lateral patellar translation between three distinct medial patellofemoral complex (MPFC) reconstruction procedures at varying knee flexion angles. Six cadaveric knee specimens were dissected, potted, and placed in a customized jig for testing. Lateral patellar displacement was measured at intervals between 0 and 90 degrees of knee flexion using a tensile testing machine with a 20 N lateral force applied to the patella. Each specimen was tested with the MPFC intact, sectioned, and after each of the three reconstruction techniques: MPFL, hybrid, and medial quadriceps-tendon femoral (MQTFL) reconstructions. There was significantly increased lateral patellar displacement following MPFC sectioning when compared with the intact state in early degrees of flexion (10-30 degrees) (p < 0.05). All three reconstruction groups restored patella stability and reduced lateral patellar displacement following sectioning from 0 to 30 degrees of flexion (p < 0.05). When compared with the intact group, all three reconstruction groups demonstrated reduced patella translation at full knee extension, while the MPFL and hybrid reconstruction groups additionally demonstrated significant reduction in patella translation at 10 degrees of flexion (p < 0.05). No significant differences were observed between the three reconstruction groups. This biomechanical study demonstrates the efficacy of three MPFC reconstruction techniques in patella stabilization following sectioning. Our results suggest that MPFL reconstruction may provide the most robust patella stabilization, whereas MQTFL reconstruction may be the most forgiving construct. This study suggests that MQTFL and hybrid reconstructions provide adequate resistance to lateral translation and may be used as an alternative to MPFL reconstruction.


Assuntos
Patela , Articulação Patelofemoral , Humanos , Patela/cirurgia , Articulação Patelofemoral/cirurgia , Ligamentos Articulares/cirurgia , Fenômenos Biomecânicos , Cadáver , Articulação do Joelho
5.
Arthroscopy ; 38(11): 3080-3089, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35772603

RESUMO

PURPOSE: To compare meniscal extrusion (ME) following medial meniscus allograft transplantation (MMAT) with and without meniscotibial ligament reconstruction (MTLR). METHODS: Ten cadaveric knees were size-matched with meniscus allografts. MMAT was performed via bridge-in-slot technique. Specimens were mounted in a testing system and ME was assessed via ultrasound anterior, directly over, and posterior to the medial collateral ligament at the joint line under 4 testing conditions: (1) 0° flexion and 0 newtons (N) of axial load, (2) 0° and 1,000 N, (3) 30° and 0 N, and (4) 30° and 1,000 N. For each condition, "mean total extrusion" was calculated by averaging measurements at each position. Next, MTLR was performed using 2 inside-out sutures through the remnant allograft meniscotibial ligament and secured to the tibia using anchors. The testing protocol was repeated. Differences in ME between MMAT alone versus MMAT + MTLR were examined. Within-group differences between the measurement positions, loading states, and flexion angles also were assessed. RESULTS: "Mean total extrusion" was greater following MMAT alone (2.56 ± 1.23 mm) versus MMAT + MTLR (2.14 ± 1.07 mm; P = .005) in the loaded state at 0° flexion. ME directly over the MCL was greater following MMAT alone (3.51 ± 1.00 mm) compared with MMAT + MTLR (2.93 ± 0.79 mm; P = .054). Posteriorly, in the loaded state at 0°, ME was greater following MMAT alone (2.43 ± 1.10 mm) compared with MMAT + MTLR (1.96 ± 0.99 mm; P = .010). In all conditions, ME was greater in the loaded state versus the unloaded state. CONCLUSIONS: Following MMAT, the addition of MTLR significantly reduced overall ME when compared with isolated MMAT during loading at 0° of flexion in a cadaveric model; given the small absolute values of change in extrusion, clinical significance cannot be gleaned from these findings. CLINICAL RELEVANCE: During medial meniscus allograft transplantation, augmentation with meniscotibial ligament reconstruction may limit meniscal extrusion and improve the biomechanical milieu of the knee joint following transplant.


Assuntos
Articulação do Joelho , Meniscos Tibiais , Humanos , Meniscos Tibiais/transplante , Fenômenos Biomecânicos , Cadáver , Articulação do Joelho/cirurgia , Ligamentos Articulares , Aloenxertos
6.
Arthroscopy ; 38(8): 2493-2503, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35157963

RESUMO

PURPOSE: To (1) determine the effect of severe patella alta on lateral patellar displacement after medial patellofemoral ligament (MPFL) reconstruction and medial quadriceps tendon-femoral ligament (MQTFL) reconstruction and (2) determine whether lateral displacement significantly differs between MPFL and MQTFL reconstructions in the setting of severe patella alta (Caton-Deschamps Index [CDI] of 1.6). METHODS: Eight cadaveric specimens were included. High-tensile strength suture was used to create a model of adjustable patellar height. Patellar height was set using fluoroscopy to CDI ratios of 1.0 (normal) and 1.6 (alta). Specimens underwent testing (1) with MPFL reconstruction, (2) with MQTFL reconstruction, and (3) in a medial patellofemoral complex (MPFC)-deficient control state, in randomized order, at both CDI settings: 1.0 and 1.6. Lateral patellar translation was measured at 0°, 10°, 20°, 30°, 45°, 60°, and 90° of knee flexion with 10 N of laterally directed load. RESULTS: At a CDI of 1.6, MPFL reconstruction showed significantly lower lateral displacement than MQTFL reconstruction at 0° and 20°. When compared with MPFC-deficient controls at a CDI of 1.6, MPFL reconstruction showed significantly lower displacement at 0° and 20° whereas MQTFL reconstruction was not significantly different at any degree of flexion. CONCLUSIONS: In the setting of severe patella alta (CDI of 1.6), MPFL reconstruction results in less lateral patellar displacement than MQTFL reconstruction at 0° and 20° of knee flexion. At higher flexion angles (≥30°), there is no difference between the 2 reconstruction techniques and the CDI no longer has an effect. At a CDI of 1.0, MPFL reconstruction shows lower displacement than MQTFL reconstruction in full extension only. Surgeons performing MPFC reconstruction should evaluate patients for patella alta and consider patellar height when deciding on the reconstruction technique. CLINICAL RELEVANCE: This study suggests that MQTFL reconstruction may be less stable than MPFL reconstruction in the setting of patella alta, without other known pathoanatomic factors, at early knee flexion angles. Patellar height should be considered when choosing the appropriate reconstruction technique in the absence of a distalization procedure.


Assuntos
Luxação Patelar , Articulação Patelofemoral , Humanos , Articulação do Joelho/cirurgia , Ligamentos Articulares/cirurgia , Patela/cirurgia , Luxação Patelar/cirurgia , Articulação Patelofemoral/cirurgia , Amplitude de Movimento Articular
7.
Arthroscopy ; 38(2): 365-373, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-33964388

RESUMO

PURPOSE: To evaluate the biomechanical properties of the labral suction seal in the native labrum and after rim preparation, labral augmentation, and labral reconstruction. METHODS: Eight hemi-pelvises were dissected to the level of labrum and mounted for biomechanical testing. Each specimen was tested in axial distraction starting with the native labrum and then sequentially following rim preparation from 12 to 3 o'clock, labral augmentation, and segmental labral reconstruction using the iliotibial band allograft. In each condition, the specimens were compressed to 250 N and then distracted at 10 mm/s with force and displacement continuously recorded. Each test was repeated 3 times, and the mean peak force, displacement at peak force, and work were calculated. Data were reported as a percentage of the intact values to account for sex and size differences. Statistical testing was performed via a repeated-measures analysis of variance with a post hoc Tukey analysis. RESULTS: Peak loads occurred within 2.21 to 3.11 mm of displacement. The mean peak force, displacement at peak force, and work relative to the intact condition were the following: rim preparation (91.1% ± 8.5%, 94.4% ± 14.3%, 93.4% ± 23.5%, respectively), augmentation (66.1% ± 27.6%, 78.2% ± 16.3%, 55.7% ± 30.7%, respectively), and reconstruction (55.6% ± 25.7%, 64.7% ± 31.4%, 38.7% ± 27.2%, respectively). There was no significant difference in peak force following the rim preparation (P = .807), but peak force was significantly decreased after augmentation and reconstruction (P = .010 and P < .001, respectively). There was no significant difference in displacement at peak force following rim preparation or augmentation (P = .936 and P = .125, respectively), but displacement at peak force was significantly decreased after reconstruction (P = .005). The work from the suction seal was significantly less in both augmentation and reconstruction states compared to the intact labrum (P = .004 and P < .001, respectively) and rim preparation (P = .017 and P < .001, respectively). CONCLUSIONS: The results show that the suction seal is not significantly changed following rim preparation. Relative to the rim preparation, labral augmentation may re-create the labral suction seal better than labral reconstruction. CLINICAL RELEVANCE: This study provides a biomechanical basis for surgical decision making and clinical management of patients with labral tears of the hip.


Assuntos
Acetábulo , Articulação do Quadril , Acetábulo/cirurgia , Cadáver , Fascia Lata/transplante , Articulação do Quadril/cirurgia , Humanos , Sucção
8.
Clin Biomech (Bristol, Avon) ; 90: 105486, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34560347

RESUMO

BACKGROUND: The success of surgical repairs rely on the effectiveness and integrity of the surgical knots used to secure the repair. The purpose of this study is to examine and compare the performance of the Nice knot, the modified Nice knot, and a commonly used combination of surgeons' and square knots with respect to cyclic loading and load-to-failure usiflueng a high-strength suture composed of ultra-high molecular weight polyethylene in the hands of experienced surgeons. METHODS: Two experienced surgeons threw 3 different knot types 9 times, consisting of the Nice knot, modified Nice knot, and a surgeon's knot utilizing Ultrabraid #2 sutures. Each knot was subject to cyclic loading and load to failure testing. FINDINGS: Both surgeons had similar displacement data for the surgeon's knot, while the identity of the surgeon impacted displacement for the Nice knot (p = 0.03) and the modified Nice knot (p = 0.0002). The load to failure for the modified Nice knot (p < 0.001) and the Nice knot (p = 0.001) were significantly impacted by the surgeon tying the knot, while the surgeon's knot was not. Specimens failed where the sutures passed through the loop at the "base" of the knot. INTERPRETATIONS: The strength and integrity of complex surgical knots are variable between surgeons. While the proposed Modified Nice Knot has a theoretical advantage because the half hitches reinforce the primary knot, in load to failure testing both the Modified Nice Knot and the Nice Knot failed where the suture passed through the loop in the primary knot.


Assuntos
Cirurgiões , Técnicas de Sutura , Artroscopia , Humanos , Teste de Materiais , Suturas , Resistência à Tração
9.
Arthroscopy ; 36(9): 2433-2442, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32504714

RESUMO

PURPOSE: To biomechanically compare the suction seal, contact area, contact pressures, and peak forces of the intact native labrum, torn labrum, 12- to 3-o'clock labral repair, and 270° labral reconstruction in the hip. METHODS: A cadaveric study was performed using 8 fresh-frozen hemipelvises with intact labra and without osteoarthritis. Intra-articular pressure maps were produced for each specimen using an electromechanical testing system under the following conditions: (1) intact labrum, (2) labral tear, (3) labral repair between the 12- and 3-o'clock positions, and (4) 270° labral reconstruction using iliotibial band allograft. Specimens were examined in neutral position, 20° of extension, and 60° of flexion. In each condition, contact pressure, contact area, and peak force were obtained. Repeated-measures analysis of variance was used to identify differences in biomechanical parameters among the 3 conditions. Qualitative differences in suction seal were compared between labral repair and labral reconstruction using the Fisher exact test. RESULTS: Repeated-measures analysis of variance for contact area in neutral position, extension, and flexion showed statistically significant differences between the normalized study states (P < .05). Post hoc analysis showed significantly larger contact areas measured in labral repair specimens than in labral reconstruction specimens in the extension and flexion positions. Region-of-interest analysis for the normalized contact area in the extension and flexion positions, as well as normalized contact pressures in neutral position, showed statistically significant differences between the labral states (P < .05). Finally, 8 labral repairs (100%) versus only 1 labral reconstruction (12.5%) retained the manually tested suction seal (P < .001). CONCLUSIONS: In this in vitro biomechanical model, 270° labral reconstruction resulted in decreased intra-articular contact area and loss of suction seal when compared with labral repair. Clinically, labral reconstruction may not restore the biomechanical characteristics of the native labrum as compared with labral repair. CLINICAL RELEVANCE: Labral reconstruction may result in lower intra-articular hip contact area and loss of suction seal, affecting the native biomechanical function of the acetabular labrum. Further biomechanical studies and clinical studies are necessary to determine whether there are any long-term consequences of 270° labral reconstruction.


Assuntos
Acetábulo/cirurgia , Fibrocartilagem/cirurgia , Articulação do Quadril/cirurgia , Osteoartrite/cirurgia , Amplitude de Movimento Articular , Idoso , Fenômenos Biomecânicos , Cadáver , Cartilagem Articular , Fascia Lata , Feminino , Humanos , Lacerações , Masculino , Pessoa de Meia-Idade , Pressão , Estresse Mecânico , Sucção
10.
Arthroscopy ; 36(9): 2425-2432, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32461022

RESUMO

PURPOSE: To compare the biomechanical properties of the hip joint with an intact femoral cam lesion, partial cam resection, and complete cam resection. METHODS: A cadaveric study was performed using 8 hemipelvises with cam-type morphology (alpha angle > 55°) and intact labra. Intra-articular pressure maps were produced for each specimen under the following conditions: (1) native cam morphology (intact), (2) cam morphology with incomplete resection (partial), and (3) cam morphology with complete resection (complete). By use of an open technique, resection of the superior portion of the cam morphology was performed with a 5.5-mm burr to create the partial resection, followed by the inferior portion to create the complete resection. In each condition, 3 biomechanical parameters were obtained: contact pressure, contact area, and peak force within a region of interest. Measurements were performed 3 times in each condition, and the average value was used for statistical analysis. Analysis of variance was used to compare biomechanical parameters between conditions. RESULTS: A statistically significant difference was found between the pre- and post-resection alpha angles (62.2° ± 3.9° vs 40.9° ± 1.4°, P < .001). Repeated-measures analysis of variance showed that the normalized average pressure values of hips with complete resection of cam lesions were significantly lower than those of hips with incomplete femoral cam lesions and hips with intact cam morphology (100% vs 93.6% ± 8.3% and 82.6% ± 16.2%, respectively; P < .0001). The percentage reduction of contact pressure in the complete and partial groups was 17.4% and 6.4%, respectively, compared with the intact group. Contact area and peak force showed no statistically significant differences across the 3 conditions (P > .05). CONCLUSIONS: Complete cam resection results in significantly lower intra-articular hip contact pressures than incomplete cam resection and native cam morphology in a cadaveric hip model. These observations underscore the importance of ensuring complete resection of femoral cam lesions in patients undergoing hip arthroscopy for femoroacetabular impingement syndrome. CLINICAL RELEVANCE: Previous studies have shown that the most common reason for revision hip arthroscopy in patients with femoroacetabular impingement syndrome is incomplete femoral cam resection during the index operation. This study shows biomechanical differences associated with partial cam resection compared with the complete cam resection state that may translate to persistent symptoms.


Assuntos
Artroscopia/métodos , Impacto Femoroacetabular/cirurgia , Fêmur/cirurgia , Articulação do Quadril/cirurgia , Amplitude de Movimento Articular , Adulto , Artrodese , Fenômenos Biomecânicos , Cadáver , Feminino , Impacto Femoroacetabular/fisiopatologia , Quadril/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos de Cirurgia Plástica , Adulto Jovem
11.
Arthroscopy ; 36(6): 1670-1676, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32061974

RESUMO

PURPOSE: To define the contributions of the of the medial patellofemoral ligament (MPFL) and medial quadriceps tendon femoral ligament (MQTFL) to lateral patellar translation as the knee moves through a 90° arc of motion. METHODS: Six pairs of bilateral cadaveric knee specimens (12 knees) were dissected and potted in perfect lateral position using fluoroscopy. An eye screw was placed in the midpoint on the lateral aspect of the patella. Each knee underwent testing in 4 conditions after sequential sectioning: intact, lateral retinacular release, randomized MQTFL or MPFL sectioning, and complete proximal medial patellar restraint (PMPR) sectioning. With a custom machined jig, all knees were tested at 0, 10, 20, 30, 45, 60, and 90° of flexion on an MTS machine with 20N of lateral patellar force applied and displacement recorded. RESULTS: PMPR extensor mechanism insertion on all specimens was identified 50% on the quadriceps tendon and 50% on the proximal aspect of the medial patella. Isolated MPFL sectioning resulted in significantly increased lateral displacement compared to the lateral release state at all flexion angles tested except 0°. There was significantly increased lateral patellar displacement with complete sectioning compared with isolated proximal sectioning at all degrees of knee flexion except 0°. However, complete sectioning following isolated MPFL sectioning did not demonstrate significance at any angle. CONCLUSIONS: Compared with the MQTFL, the MPFL is primarily responsible for resistance to lateral patellar translation throughout a 0° to 90° arc of motion. The MPFL provides a similar resistance to lateral patellar displacement as the fully intact PMPR; however, the MQTFL may contribute to resistance in full extension. CLINICAL SIGNIFICANCE: Proximal medial patellar restraint reconstruction techniques involving both the patellar and quadriceps insertion have been described; however, the unique contributions of the native anatomy to lateral patellar restraint have not been investigated.


Assuntos
Ligamentos Articulares/anatomia & histologia , Patela/anatomia & histologia , Articulação Patelofemoral/anatomia & histologia , Músculo Quadríceps/anatomia & histologia , Tendões/anatomia & histologia , Adulto , Fenômenos Biomecânicos , Cadáver , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Articulação Patelofemoral/fisiologia , Articulação Patelofemoral/cirurgia , Amplitude de Movimento Articular
12.
J Orthop Surg Res ; 14(1): 391, 2019 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-31779665

RESUMO

INTRODUCTION: Management of the subscapularis during shoulder arthroplasty is controversial. The purpose of this study was to compare the biomechanical performance of subscapularis peel (SP) and lesser tuberosity osteotomy (LTO) in a cadaveric model. METHODS: The subscapularis and proximal humerus were dissected from all soft tissues in 21 fresh-frozen human cadaveric shoulders and randomized to undergo SP, LTO, or standard subscapularis tenotomy (ST, control). For SP and LTO, six #5 sutures were passed through eyelets in the implant (on lateral border and through drill holes in bicipital groove [2] and under trunion [4]). Double-row repair was performed using two lateral row transosseous sutures and four medial row sutures through the tendon (SP) or osseotendinous junction (LTO). Biomechanical properties and mode of failure were tested. RESULTS: There were no significant differences in elongation amplitude, cyclic elongation, or maximum load to failure between the three groups (P > 0.05). Mean stiffness was significantly higher in LTO (P = 0.009 vs. SP and ST). In the ST group, 7/7 specimens failed at the tendon-suture interface. For SP, 4/7 failed at the tendon-suture interface, one at the suture-bone interface, one fractured around the implant stem, and one at the knots. For LTO, 3/7 failed at the tendon-suture interface, two at the suture-bone interface and two fractured around the implant stem. CONCLUSIONS: In this cadaveric model, subscapularis repair via ST, SP, and LTO techniques was biomechanically equivalent. Additional studies are needed to confirm these findings and determine the influence of biologic healing on healing rates and clinical outcomes. LEVEL OF EVIDENCE: N/a, biomechanical laboratory study.


Assuntos
Osteotomia/métodos , Manguito Rotador/cirurgia , Artroplastia/métodos , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Articulação do Ombro/cirurgia , Técnicas de Sutura , Tendões/cirurgia
13.
Arthroscopy ; 35(6): 1760-1768, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31072716

RESUMO

PURPOSE: To compare the biomechanical properties of all-suture suture anchors (ASSAs) with conventional interference screws (CISs) and conventional suture anchors (CSAs) for long head of the biceps tendon fixation during proximal biceps tenodesis (BT). METHODS: We randomized 21 fresh-frozen human cadaveric shoulders into 3 subpectoral BT treatment groups: ASSA, CSA, and CIS. Each construct was cyclically loaded from 5 to 70 N for 500 cycles (1 Hz). All specimens that survived cyclic loading were then pulled to failure (1 mm/s). Elongation, maximum load, energy, and failure mode were recorded. The humerus was stripped of tissue and then subjected to torsional displacement at a rate of 1°/s until fracture occurred. Maximum load, displacement, stiffness, and energy were recorded. RESULTS: During tendon testing, 3 specimens (43%) in the CIS group failed early during cyclic testing by the tendon tearing at the screw-tendon interface. All other specimens in the CIS group, as well as all specimens in the ASSA and CSA groups, survived cyclic testing and failed during pull-to-failure testing. Failure occurred at the tendon-anchor or -screw interface in all specimens (100%), with no anchor or screw pullout. The CIS group had significantly decreased elongation (8.9 ± 2.23 mm) at maximum load compared with the ASSA (19.2 ± 5.2 mm) and CSA (18.9 ± 2.23 mm) groups (P = .001). During torsional testing, the ASSA group was able to withstand significantly greater torsional displacement (9.22° ± 0.86°) before failure and had greater energy to failure (497.3 ± 45 Nmm-degrees) than the CIS group (6.13° ± 1.24° and 256.6 ± 70.3 Nmm-degrees, respectively; P = .005). CONCLUSIONS: This study shows that the biomechanical properties of ASSA, CSA, and CIS constructs are similar. The interference screw group had lower tendon elongation at maximum load but had several early failures compared with the suture anchor groups. The use of suture anchors results in maximum tendon and torsional bone loads similar to interference screws for the long head of the biceps tendon. Torsional testing of the CIS resulted in spiral fractures traversing the screw tunnel in 100% of the specimens, which was not found in the suture anchor groups. CLINICAL RELEVANCE: The ASSA is a viable fixation method for BT in comparison with the CSA and CIS.


Assuntos
Parafusos Ósseos , Músculo Esquelético/cirurgia , Procedimentos de Cirurgia Plástica , Âncoras de Sutura , Traumatismos dos Tendões/cirurgia , Tendões/cirurgia , Tenodese/métodos , Braço/cirurgia , Fenômenos Biomecânicos , Cadáver , Humanos , Úmero/cirurgia , Pessoa de Meia-Idade , Procedimentos Ortopédicos , Distribuição Aleatória , Ombro/cirurgia , Estresse Mecânico , Técnicas de Sutura , Suturas , Resistência à Tração
14.
J Shoulder Elbow Surg ; 28(8): 1531-1536, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30948215

RESUMO

BACKGROUND: The aim of this study was to compare the biomechanical performance of whip-stitch (WS) and simple suture techniques (SST) of the long head of the biceps tendon in suprapectoral intraosseous tenodesis with interference screw fixation. METHODS: A total of 10 paired cadavers (61.1 ± 4.6 years) were randomized to receive WS or SST biceps tenodesis beginning at the musculotendinous junction. Both groups implemented a No. 2 FiberLoop wire and underwent suprapectoral fixation with a polyetheretherketone interference screw at the bicipital grove. A Materials Testing System performed cyclic testing (500 cycles), followed by load to failure at 1 mm/s. Load, displacement, and time were recorded during cyclic and failure testing. A 2-tailed Student's t-test and χ2 analysis were performed for failure load and mode of failure, respectively. RESULTS: Two SST specimens and 1 WS specimen failed during cyclic loading via tendon rupture at the screw-tendon interface. There was no significant statistical difference in the cyclic displacement after 500 cycles between the WS (12.9 mm ± 4.4 mm) and SST groups (14.0 mm ± 3.8 mm, P = .2); cyclic strain, defined as the peak displacement at the 500th cycle divided by the initial gauge length, between the WS (0.4 ± 0.2) and SST groups (0.7 ± 0.7, P = .3); maximal load (162.7 N ± 56.8 N vs. 153.1 N ± 39.3 N, respectively, P = .6); and stiffness (50.5 N/mm ± 17.7 N/mm vs. 43.3 N/mm ± 10.9 N/mm, respectively, P = .3). All specimens ruptured at the screw-tendon interface. CONCLUSION: The WS technique can provide equivalent biomechanical performance to the SST in suprapectoral intraosseous biceps tenodesis with interference screw fixation.


Assuntos
Artroscopia/métodos , Articulação do Cotovelo/fisiopatologia , Procedimentos de Cirurgia Plástica/métodos , Técnicas de Sutura , Traumatismos dos Tendões/cirurgia , Tendões/cirurgia , Tenodese/métodos , Idoso , Fenômenos Biomecânicos , Parafusos Ósseos , Cadáver , Articulação do Cotovelo/cirurgia , Humanos , Pessoa de Meia-Idade , Músculo Esquelético/cirurgia , Ruptura , Traumatismos dos Tendões/fisiopatologia , Lesões no Cotovelo
15.
Arthroscopy ; 35(5): 1370-1376, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-31000387

RESUMO

PURPOSE: To compare the biomechanical properties of all-suture suture anchors (ASSAs) with conventional suture anchors (CSAs) for double-row rotator cuff repair (RCR). METHODS: Fourteen fresh-frozen human cadaveric shoulders were randomized into 2 RCR treatment groups: ASSA and CSA. All constructs received a double-row repair, with the lateral-row implants consisting of two 5.5-mm PEEK (polyether ether ketone) Footprint anchors. Each construct was loaded to a 10-N preload for 2 minutes, followed by cyclic loading from 10 to 160 N at a rate of 100 N/s for 100 cycles. Load-to-failure testing was performed immediately after cyclic loading testing at 1 mm/s from the zero position until failure. Cyclic creep, elongation amplitude, maximum load, stiffness, energy, and failure mode were recorded. RESULTS: No significant difference in cyclic creep (P = .117) or elongation amplitude (P = .428) was found between the ASSA and CSA groups during cyclic testing. Three specimens in each group (43% in each) failed by the suture tearing through the tendon. The remaining specimens in each group failed by the anchor pulling out of the humeral head. The mean maximum load was 617.73 ± 177.77 N and 545.13 ± 212.98 N for the ASSA and CSA groups, respectively (P = .339). Maximum elongation before failure was not different between groups (P = .122). Mean energy and stiffness were not statistically different between the ASSA and CSA groups (P = .629 and P = .973, respectively). CONCLUSIONS: In this cadaveric analysis with a simplified unidirectional experimental setup, failure mechanics and maximum load between the ASSA and CSA constructs were similar, with no difference in energy and stiffness. Although the ASSA group showed slightly larger elongation than the CSA group, these differences may not be clinically relevant. CLINICAL RELEVANCE: This study provides a biomechanical head-to-head comparison of ASSAs and CSAs, indicating that ASSAs may be clinically equivalent to CSAs for use in an RCR.


Assuntos
Artroplastia/instrumentação , Lesões do Manguito Rotador/cirurgia , Manguito Rotador/cirurgia , Âncoras de Sutura , Adulto , Idoso , Artroplastia/métodos , Fenômenos Biomecânicos , Cadáver , Humanos , Masculino , Pessoa de Meia-Idade , Distribuição Aleatória , Ombro/cirurgia , Estresse Mecânico , Técnicas de Sutura , Tendões/cirurgia
16.
Am J Sports Med ; 46(13): 3127-3133, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30307738

RESUMO

BACKGROUND: Interportal and T-capsulotomies are popular techniques for exposing femoroacetabular impingement deformities. The difference between techniques with regard to the force required to distract the hip is currently unknown. PURPOSE: To quantify how increasing interportal capsulotomy size, conversion to T-capsulotomy, and subsequent repair affect the force required to distract the hip. STUDY DESIGN: Controlled laboratory study. METHODS: Eight fresh-frozen cadaveric hip specimens were dissected and fixed in a materials testing system, such that pure axial distraction of the iliofemoral ligament could be achieved. The primary outcome measure was the load required to distract the hip to a distance of 6 mm at a rate of 0.5 mm/s. Each hip was tested in the intact state and then sequentially under varying capsulotomy conditions: 2-cm interportal, 4-cm interportal, half-T (4-cm interportal and 2-cm T-capsulotomy), and full-T (4-cm interportal and 4-cm T-capsulotomy). After serial testing, isolated T-limb repair and then subsequent complete repair were performed. Repaired specimens underwent distraction testing as previously stated to assess the ability to restore hip stability to the native profile. Distraction force as well as the relative distraction force (percentage normalized to the intact capsule) were compared between all capsulotomy and repair conditions. RESULTS: Increasing interportal capsulotomy size from 2 to 4 cm resulted in significantly less force required to distract the hip ( P < .001). The largest relative decrease in force was seen between the intact state (274.6 ± 71.2 N; 100%) and 2-cm interportal (209.7 ± 73.2 N; 76.4% ± 15.6%; P = .0008). There was no significant mean difference in distraction force when 4-cm interportal (160.4 ± 79.8 N) was converted to half-T (140.7 ± 73.5 N; P = .270) and then full-T (112.0 ± 70.2 N; P = .204). When compared with the intact state, isolated T-limb repair partially restored stability (177.3 ± 86.3 N; 63.5% ± 19.8%; P < .0001), while complete repair exceeded native values (331.7 ± 103.7 N; 122.7% ± 15.1%; P = .0008). CONCLUSION: The conversion of interportal capsulotomy to T-capsulotomy did not significantly affect the force required to distract the hip in a cadaveric model. However, larger interportal capsulotomies resulted in significant stepwise decreases in distraction force. When performing interportal or T-capsulotomy, the iliofemoral ligament strength is significantly decreased, but complete capsular repair demonstrated the ability to restore joint stability to the native, intact hip. CLINICAL RELEVANCE: Increasing interportal capsulotomy size decreases the force required to distract the hip. In an effort to maximize visualization and minimize the magnitude of iliofemoral ligament fibers cut, many surgeons have moved from extended interportal capsulotomy to T-capsulotomy. Interportal and T-capsulotomies result in equivalent hip distraction, partial capsular repair marginally improves hip stability, and only complete repair has the ability to restore the hip to its native biomechanical profile.


Assuntos
Artroscopia/métodos , Articulação do Quadril/cirurgia , Idoso , Cadáver , Impacto Femoroacetabular/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade
17.
Arthroscopy ; 34(3): 806-813, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29287950

RESUMO

PURPOSE: To quantify the torsional load to fracture for subpectoral biceps tenodesis with interference screw fixation. METHODS: We randomized 28 specimens from 14 matched-pair full-length humeri (mean age, 55.3 years) into 3 groups: (1) empty ream group (ERG), (2) screw-only group (SOG), and (3) screw-plus-biceps tendon group (SBG). In each group, 1 humerus of each matched pair was prepared according to group allocation and the contralateral humerus remained intact as a control. In the ERG, an 8-mm unicortical hole was reamed 1 cm proximal to the inferior border of the pectoralis major tendon insertion; in the SOG, the humerus was filled with an 8-mm × 12-mm PEEK (polyether ether ketone) screw; and in the SBG, the humerus was filled with a PEEK screw and the cadaveric long head of the biceps tendon. Humeri were tested under torsional displacement at a rate of 1°/s until fracture. Maximum torque, energy to maximum torque, and linear stiffness were used to assess humerus strength. RESULTS: Compared with contralateral intact specimens, the maximum torque to fracture was reduced by 28% in the ERG (P = .005), 30% in the SOG (P = .014), and 20% in the SBG (P = .046). Energy to maximum torque was similarly reduced in the ERG (P = .007), SOG (P = .023), and SBG (P = .049). Stiffness was increased by 4% in the ERG (P = .498), 9% in the SOG (P = .030), and 4% in the SBG (P = .439). CONCLUSIONS: Drilling an 8-mm unicortical hole in zone 3 of the bicipital tunnel for open subpectoral biceps tenodesis reduces the torsional load to humeral fracture up to 28% at time 0. The addition of a PEEK tenodesis screw alone reduced the maximum torque by 30%, and the addition of a screw with the long head of the biceps tendon reduced the maximum torque by 20%. The total load to fracture was reduced in all settings. Stiffness was not significantly different for the ERG and SBG, but stiffness was significantly higher for the SOG compared with the intact matched humeri at time 0. CLINICAL RELEVANCE: When performing a biceps tenodesis, humeral fracture susceptibility is increased with an applied torsional load at time 0. Thus providers must be aware of this reduced integrity when a subpectoral biceps tenodesis is used.


Assuntos
Parafusos Ósseos/efeitos adversos , Fraturas do Úmero/etiologia , Tenodese/efeitos adversos , Adulto , Idoso , Benzofenonas , Fenômenos Biomecânicos , Cadáver , Feminino , Humanos , Fraturas do Úmero/cirurgia , Úmero/cirurgia , Cetonas , Teste de Materiais/métodos , Pessoa de Meia-Idade , Músculo Esquelético/cirurgia , Polietilenoglicóis , Polímeros , Distribuição Aleatória , Medição de Risco/métodos , Articulação do Ombro/cirurgia , Tendões/cirurgia , Tenodese/instrumentação , Torque
18.
Arthroscopy ; 33(9): 1646-1653, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28688826

RESUMO

PURPOSE: To compare the initial fixation stability, failure strength, and mode of failure of 5 different screw types and fixation methods commonly used for the classic Latarjet procedure. METHODS: Thirty-five fresh-frozen cadaveric shoulder specimens were allocated into 5 groups. A 25% anteroinferior glenoid defect was created, and a classic Latarjet coracoid transfer procedure was performed. All grafts were fixed with 2 screws, differing by screw type and/or fixation method. The groups included partially threaded solid 4.0-mm cancellous screws with bicortical fixation, partially threaded solid 4.0-mm cancellous screws with unicortical fixation, fully threaded solid 3.5-mm cortical screws with bicortical fixation, partially threaded cannulated 4.0-mm cancellous screws with bicortical fixation, and partially threaded cannulated 4.0-mm captured screws with bicortical fixation. All screws were stainless steel. Outcomes included cyclic creep and secant stiffness during cyclic loading, as well as load and work to failure during the failure test. Intergroup comparisons were made by a 1-way analysis of variance. RESULTS: There were no significant differences among different screw types or fixation methods in cyclic creep or secant stiffness after cyclic loading or in load to failure or work to failure during the failure test. Post-failure radiographs showed evidence of screw bending in only 1 specimen that underwent the Latarjet procedure with partially threaded solid cancellous screws with bicortical fixation. The mode of failure for all specimens analyzed was screw cutout. CONCLUSIONS: In this biomechanical study, screw type and fixation method did not significantly influence biomechanical performance in a classic Latarjet procedure. When performing this procedure, surgeons may continue to select the screw type and method of fixation (unicortical or bicortical) based on preference; however, further studies are required to determine the optimal method of treatment. CLINICAL RELEVANCE: Surgeons may choose the screw type and fixation method based on preference when performing the Latarjet procedure.


Assuntos
Parafusos Ósseos , Instabilidade Articular/cirurgia , Articulação do Ombro/cirurgia , Adulto , Idoso , Fenômenos Biomecânicos , Cadáver , Processo Coracoide/transplante , Desenho de Equipamento , Falha de Equipamento , Feminino , Humanos , Masculino , Teste de Materiais/métodos , Pessoa de Meia-Idade , Osteotomia/métodos , Radiografia , Escápula
19.
Arthroscopy ; 33(3): 559-565, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28012635

RESUMO

PURPOSE: To quantify how increasing interportal capsulotomy size affects the force required to distract the hip and to biomechanically compare simple side-to-side suture repair to acetabular-based suture anchors as capsular repair techniques. METHODS: Twelve fresh-frozen cadaveric hip specimens were dissected to the capsuloligamentous complex of the hip joint and fixed in a material testing system, such that a pure axial distraction of the iliofemoral ligament could be achieved. After each hip in was tested an intact state, sequential distraction was tested with 2, 4, 6, and 8 cm capsulotomies. Specimens were assigned randomly to be repaired with either 4 side-to-side suture repair (n = 6) or 2 double-loaded all-suture anchors (n = 6). The distraction force as well as the relative distraction force percentage normalized to the intact capsule were compared between suture repair and suture anchor repair groups. RESULTS: Increasing the size of the capsulotomy resulted in less force required to distract the hip to 6 mm. The force decreased as the capsulotomy was extended with statistical significance in distraction force seen between the intact state and the 4 cm (P = .003), 6 cm (P < .001), and 8 cm (P ≤ .001) capsulotomy but not for the intact state compared to the 2 cm capsulotomy (P = .28). Statistical significance in relative distraction force was seen for each of the capsulotomy conditions (P < .001 for all conditions compared with the intact state). The side-to-side suture repair construct (104.3% of intact force) required greater force to distraction to 6 mm compared with the suture anchor repair (87.1% of intact force) (P = .008). CONCLUSIONS: An interportal capsulotomy significantly affected the force required to distract the hip in a cadaveric model, with the larger the size of capsulotomy resulting in less force required to distract the hip. When we performed an interportal capsulotomy, the iliofemoral ligament strength was altered significantly but capsular repair with either side-to-side sutures or suture anchor-based repair was able to restore the capsular strength to a native intact hip. We found, however, that the side-to-side suture repair was better able to restore the distraction force compared with suture anchor repair. CLINICAL RELEVANCE: Capsular management during hip arthroscopy remains a debated topic, with multiple techniques involving both capsulotomy and capsular closure published in the literature. This study provides insight into capsular stability against axial stress under capsulotomy and capsular repair conditions.


Assuntos
Articulação do Quadril/cirurgia , Cápsula Articular/cirurgia , Âncoras de Sutura , Técnicas de Sutura , Tração , Idoso , Cadáver , Humanos , Teste de Materiais , Estresse Mecânico
20.
Arthroscopy ; 33(2): 242-250, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27570170

RESUMO

PURPOSE: To compare the biomechanical performance of medial row suture placement relative to the musculotendinous junction (MTJ) in a cadaveric transosseous equivalent suture bridge (TOE-SB) double-row (DR) rotator cuff repair (RCR) model. METHODS: A TOE-SB DR technique was used to reattach experimentally created supraspinatus tendon tears in 9 pairs of human cadaveric shoulders. The medial row sutures were passed either near the MTJ (MTJ group) or 10 mm lateral to the MTJ (rotator cuff tendon [RCT] group). After the supraspinatus repair, the specimens underwent cyclic loading and load to failure tests. The localized displacement of the markers affixed to the tendon surface was measured with an optical tracking system. RESULTS: The MTJ group showed a significantly higher (P = .03) medial row failure (5/9; 3 during cyclic testing and 2 during load to failure testing) compared with the RCT group (0/9). The mean number of cycles completed during cyclic testing was lower in the MTJ group (77) compared with the RCT group (100; P = .07) because 3 specimens failed in the MTJ group during cyclic loading. There were no significant differences between the 2 study groups with respect to biomechanical properties during the load to failure testing. CONCLUSIONS: In a cadaveric TOE-SB DR RCR model, medial row sutures through the MTJ results in a significantly higher rate of medial row failure. CLINICAL RELEVANCE: In rotator cuff tears with tendon tissue loss, passage of medial row sutures through the MTJ should be avoided in a TOE-SB RCR technique because of the risk of medial row failure.


Assuntos
Lesões do Manguito Rotador/cirurgia , Técnicas de Sutura , Fenômenos Biomecânicos , Cadáver , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estresse Mecânico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA