Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
World J Gastroenterol ; 30(16): 2272-2280, 2024 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-38690021

RESUMO

BACKGROUND: The magnetic compression technique has been used to establish an animal model of tracheoesophageal fistula (TEF), but the commonly shaped magnets present limitations of poor homogeneity of TEF and poor model control. We designed a T-shaped magnet system to overcome these problems and verified its effectiveness via animal experiments. AIM: To investigate the effectiveness of a T-shaped magnet system for establishing a TEF model in beagle dogs. METHODS: Twelve beagles were randomly assigned to groups in which magnets of the T-shaped scheme (study group, n = 6) or normal magnets (control group, n = 6) were implanted into the trachea and esophagus separately under gastroscopy. Operation time, operation success rate, and accidental injury were recorded. After operation, the presence and timing of cough and the time of magnet shedding were observed. Dogs in the control group were euthanized after X-ray and gastroscopy to confirm establishment of TEFs after coughing, and gross specimens of TEFs were obtained. Dogs in the study group were euthanized after X-ray and gastroscopy 2 wk after surgery, and gross specimens were obtained. Fistula size was measured in all animals, and then harvested fistula specimens were examined by hematoxylin and eosin (HE) and Masson trichrome staining. RESULTS: The operation success rate was 100% for both groups. Operation time did not differ between the study group (5.25 min ± 1.29 min) and the control group (4.75 min ± 1.70 min; P = 0.331). No bleeding, perforation, or unplanned magnet attraction occurred in any animal during the operation. In the early postoperative period, all dogs ate freely and were generally in good condition. Dogs in the control group had severe cough after drinking water at 6-9 d after surgery. X-ray indicated that the magnets had entered the stomach, and gastroscopy showed TEF formation. Gross specimens of TEFs from the control group showed the formation of fistulas with a diameter of 4.94 mm ± 1.29 mm (range, 3.52-6.56 mm). HE and Masson trichrome staining showed scar tissue formation and hierarchical structural disorder at the fistulas. Dogs in the study group did not exhibit obvious coughing after surgery. X-ray examination 2 wk after surgery indicated fixed magnet positioning, and gastroscopy showed no change in magnet positioning. The magnets were removed using a snare under endoscopy, and TEF was observed. Gross specimens showed well-formed fistulas with a diameter of 6.11 mm ± 0.16 mm (range, 5.92-6.36 mm), which exceeded that in the control group (P < 0.001). Scar formation was observed on the internal surface of fistulas by HE and Masson trichrome staining, and the structure was more regular than that in the control group. CONCLUSION: Use of the modified T-shaped magnet scheme is safe and feasible for establishing TEF and can achieve a more stable and uniform fistula size compared with ordinary magnets. Most importantly, this model offers better controllability, which improves the flexibility of follow-up studies.


Assuntos
Modelos Animais de Doenças , Imãs , Traqueia , Fístula Traqueoesofágica , Animais , Cães , Fístula Traqueoesofágica/cirurgia , Fístula Traqueoesofágica/patologia , Fístula Traqueoesofágica/etiologia , Traqueia/cirurgia , Traqueia/patologia , Esôfago/cirurgia , Esôfago/patologia , Esôfago/diagnóstico por imagem , Gastroscopia/instrumentação , Gastroscopia/métodos , Duração da Cirurgia , Masculino , Magnetismo/instrumentação , Desenho de Equipamento , Humanos
2.
Int J Surg ; 2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38814355

RESUMO

BACKGROUND: Some cases of laparoscopic-assisted liver transplantation (LA-LT) with utilization of reduced-size grafts has been reported. We here introduced successful utilization of LA-LT with whole liver grafts and magnetic portal vein anastomosis. METHODS: Eight patients with liver cirrhosis were included for LA-LT using donor organs after cardiac death. The surgical procedures included purely laparoscopic explant hepatectomy and whole-liver graft implantation via the midline incision. After explant removal, the whole-liver graft was then placed in situ, and a side-to-side cavo-caval anastomosis with 4-5 cm oval opening was performed. The magnetic rings were everted on the donor and recipient portal vein, respectively, and the instant attachment of the two magnets at the donor and recipient portal vein allowed fast blood reperfusion, followed by continuous suturing on the surface of the magnets. RESULTS: The median operation time was 495 (range 420-630). The median time of explant hepatectomy and IVC anastomosis was 239 (range 150-300) min and 14.5 (range 10-19) min, respectively. Of note, the median anhepatic time was 25 (range 20-35) min. All the patients were discharged home with no major complications after more than six months follow-up. CONCLUSION: LA-LT with full-size graft is feasible and utilization of magnetic anastomosis would further simplify the procedure.

3.
Sci Rep ; 13(1): 20143, 2023 11 17.
Artigo em Inglês | MEDLINE | ID: mdl-37978305

RESUMO

Magnetic anastomosis substantially shortens the duration of vascular anastomosis. We aimed to apply magnetic anastomosis technology (MAT) to donor liver implantations in pig orthotopic liver transplantation (OLT). Twenty healthy adult pigs were randomly divided into donors and recipients, and major vascular anastomosis was performed using MAT during OLT. Recipient liver and kidney function was measured pre-surgery and 12, 24 and 72 h post-surgery. Vascular anastomoses examinations were performed using ultrasound or angiography weekly post-surgery, and pathological examinations of vascular anastomoses were performed during autopsy after animal euthanasia. All recipients survived 24 h after surgery, which is considered as successful transplantation. Anhepatic duration was only 13 min, and no anastomotic obstruction or stenosis, magnetic displacement and anastomotic angulation, or distortion was found upon postoperative examinations of major liver vasculature. Aspartate aminotransferase, alanine aminotransferase, and total bilirubin serum levels increased considerably postoperatively. The follow-up period for this study was 1 year, and the median survival time of all recipients was 115 d (interquartile range = 11-180 d). The main causes of death were liver failure, immune rejection, infection, and arterial anastomotic bleeding. Moreover, vascular anastomoses healed well with a survival time of more than two weeks. We developed a novel magnetic device to create a fast and safe technique to perform major vascular anastomoses in pig liver transplantations. Additionally, the liver graft implantation using MAT considerably shortened the recipient warm ischemia time, which will reduce the extent of ischemia-reperfusion injury. We conclude that MAT is an effective method for donor liver fast implantation in OLT in pigs.


Assuntos
Transplante de Fígado , Animais , Anastomose Cirúrgica/métodos , Fígado/cirurgia , Transplante de Fígado/métodos , Doadores Vivos , Fenômenos Magnéticos , Suínos , Modelos Animais , Distribuição Aleatória
4.
World J Gastroenterol ; 29(33): 5005-5013, 2023 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-37731993

RESUMO

BACKGROUND: Although endoscope-assisted magnetic compression anastomosis has already been reported for colonic anastomosis, there is no report on a single-approach operation using the natural orifice. AIM: To design a deformable self-assembled magnetic anastomosis ring (DSAMAR) for colonic anastomosis for use in single-approach operation and evaluate its feasibility and safety through animal experiments. METHODS: The animal model for colonic stenosis was prepared by partial colonic ligation in eight beagles. The magnetic compression anastomosis of their colonic stricture was performed by endoscopically assisted transanal implantation of the DSAMAR. The anastomotic specimen, obtained 2 wk after the operation, was observed by both the naked eye and a light microscope. RESULTS: The DSAMAR was successfully inserted into the proximal end of colon stenosis through the anus. The DSAMAR of seven dogs was successfully transformed into rings, while that of the remaining dog was removed after the first deformation failed. The rings were successfully retransformed after optimization. All animals underwent colonic anastomosis using the DSAMAR. No device-related or procedure-related adverse events were observed. The colostomy specimens of the experimental dogs were obtained 2 wk after the operation. Both gross and histological observations showed good anastomotic healing. CONCLUSION: The DSAMAR is a safe and feasible option for the treatment of colon stenosis. Its specific deformation and self-assembly capability maximize the applicability of the minimally invasive treatment.


Assuntos
Endoscopia , Obstrução Intestinal , Animais , Cães , Constrição Patológica/cirurgia , Anastomose Cirúrgica , Fenômenos Magnéticos
5.
World J Gastrointest Surg ; 15(7): 1286-1293, 2023 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-37555113

RESUMO

BACKGROUND: Hepatic portal blood flow occlusion is a common technique for reducing hepatic hemorrhage during hepatectomy. We designed a novel Y-Z magnetic hepatic portal blocking band (Y-Z MHPBB) based on the principle of magnetic compression technique. AIM: To introduce the Y-Z MHPBB device and verify the feasibility of this device for hepatic portal blood flow occlusion in dogs. METHODS: Ten beagles were randomly divided into the experimental group and control group. The operation time, intraoperative blood loss, the number of portal blood flow occlusions, the total time spent on adjusting the blocking band, and the average time spent on adjusting the blocking band were recorded. The surgeons evaluated the feasibility and flexibility of the two portal occlusion devices. RESULTS: Laparoscopic hepatectomy was successfully performed in both the experimental group and control group. There was no statistical difference between the two groups in the operation time, intraoperative blood loss, and the number of hepatic portal blood flow occlusions. With respect to the total time spent on adjusting the blocking band and the average time spent on adjusting the blocking band, the experimental group showed significantly better outcomes than the control group, with a statistical difference (P < 0.05). The operators found that the Y-Z MHPBB was superior to the modified T-tube in terms of operational flexibility. CONCLUSION: The Y-Z MHPBB seems to be an ingenious design, accurate blood flow occlusion effect, and good flexibility; and it can be used for hepatic portal blood flow occlusion during laparoscopic hepatectomy.

6.
World J Gastrointest Surg ; 15(7): 1294-1303, 2023 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-37555127

RESUMO

BACKGROUND: Magnetic compression anastomosis (MCA) is a simple procedure contributing to a reliable anastomosis. However, digestive-tract reconstruction after total gastrectomy using MCA has not yet been reported. AIM: To investigate the feasibility of MCA for simultaneous esophagojejunostomy and jejunojejunostomy after total gastrectomy using beagle dogs. METHODS: Sixteen beagles were randomly divided into an MCA group (study group, n = 8) and a manual-suture anastomosis group (control group, n = 8). Two different magnetic anastomosis devices were used in the study group for esophagojejunal and jejunojejunal anastomoses. Both devices included a pair of circular daughter and parent magnets each. The time of esophagojejunostomy and jejunojejunostomy, postoperative complications, and survival rate of the two groups were compared. The dogs were sacrificed one month after the operation and their anastomotic specimens were obtained. Healing was observed by the naked eye and a light microscope. RESULTS: Digestive-tract reconstruction after total gastrectomy was successfully completed in both groups (survival rate = 100%). In the study group, esophagojejunal and jejunojejunal anastomoses took 6.13 ± 0.58 and 4.06 ± 0.42 min, respectively, significantly lower than those in the control group (15.63 ± 1.53 min, P < 0.001 and 10.31 ± 1.07 min, P < 0.001, respectively). Complications such as bleeding, anastomotic leakage, and anastomotic stenosis were not observed. In the study group, the magnets did not interfere with each other. Discharge time of the jejunojejunal magnetic anastomosis device was 10.75 ± 1.28 d, while that of the esophagojejunal magnetic anastomosis device was 12.25 ± 1.49 d. Residual silk was found in the control group. The study group showed a greater smoothness of the anastomosis than that of the control group. All layers of anastomosis healed well in both groups. CONCLUSION: MCA is a safe and feasible procedure for digestive-tract reconstruction after total gastrectomy in this animal model.

7.
Sci Rep ; 12(1): 9979, 2022 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-35705647

RESUMO

Many methods are used to locate preoperative small pulmonary nodules. However, deficiencies of complications and success rates exist. We introduce a novel magnetic gel for small pulmonary nodules localization in rabbit model, and furtherly evaluate its safety and feasibility. Rabbits were used as the experimental objects. A magnetic gel was used as a tracer magnet, mixed as sodium alginate-Fe3O4 magnetic fluid and calcium gluconate solution. In short-term localization, a coaxial double-cavity puncture needle was applied to inject the gel into the lung after thoracotomy, and a pursuit magnet made of Nd-Fe-B permanent magnetic materials was used to attract the gel representing location of the nodule. In long-term localization, the gel was injected under X-ray guidance. Imaging changes to the lung were observed under X-ray daily. Thoracotomy was performed to excise tissue containing the gel, and hematoxylin-eosin staining was used to observe the tissue on postoperative days 1, 3, 5, and 7. Observe tissues morphology of heart, liver, spleen, and kidney in the same way. The gel was formed after injection and drew lung tissue to form a protrusion from the lung surface under the applied magnetic field. No complication was observed. The shape and position of the gel had not changed when viewed under X-ray. Pathological analysis showed the gel had a clear boundary without diffusion of magnetic fluid. All tissues retained good histologic morphology and no magnetic fluid was observed. Our study preliminarily suggested that the technique using sodium alginate-Fe3O4 magnetic gel to locate small pulmonary nodules with guidance of X-ray, and to search for them under an applied magnetic field during the operation is safe and feasible.


Assuntos
Neoplasias Pulmonares , Nódulos Pulmonares Múltiplos , Nódulo Pulmonar Solitário , Alginatos , Animais , Neoplasias Pulmonares/patologia , Nódulos Pulmonares Múltiplos/patologia , Coelhos , Estudos Retrospectivos , Nódulo Pulmonar Solitário/patologia , Cirurgia Torácica Vídeoassistida , Tomografia Computadorizada por Raios X/métodos
8.
Hepatobiliary Pancreat Dis Int ; 21(4): 340-346, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35022144

RESUMO

BACKGROUND: Although laparoscopic technology has achieved rapid development in the surgical field, it has not been applied to liver transplantation, primarily because of difficulties associated with laparoscopic vascular anastomosis. In this study, we introduced a new magnetic-assisted vascular anastomosis technique and explored its application in laparoscopic liver transplantation in pigs. METHODS: Two sets of magnetic vascular anastomosis rings (MVARs) with different diameters were developed. One set was used for anastomosis of the suprahepatic vena cava (SHVC) and the other set was used for anastomosis of the infrahepatic vena cava (IHVC) and portal vein (PV). Six laparoscopic orthotopic liver transplantations were performed in pigs. Donor liver was obtained via open surgery. Hepatectomy was performed in the recipients through laparoscopic surgery. Anastomosis of the SHVC was performed using hand-assisted magnetic anastomosis, and the anastomosis of the IHVC and PV was performed by magnetic anastomosis with or without hand assistance. RESULTS: Liver transplants were successfully performed in five of the six cases. Postoperative ultrasonographic examination showed that the portal inflow was smooth. However, PV bending and blood flow obstruction occurred in one case because the MVARs were attached to each other. The durations of loading of MVAR in the laparoscope group and manual assistance group for IHVC and PV were 13 ± 5 vs. 5 ± 1 min (P < 0.01) and 10 ± 2 vs. 4 ± 1 min (P < 0.05), respectively. The durations of MVAR anastomosis in the laparoscope group and manual assistance group for IHVC and PV were 5 ± 1 vs. 1 ± 1 min (P < 0.01), and 5 ± 1 vs. 1 ± 1 min (P < 0.01), respectively. The anhepatic phase was 43 ± 4 min in the laparoscope group and 23 ± 2 min in the manual assistance group (P < 0.01). CONCLUSIONS: Our study showed that magnetic-assisted laparoscopic liver transplantation can be successfully carried out in pigs.


Assuntos
Laparoscopia , Transplante de Fígado , Anastomose Cirúrgica/métodos , Animais , Humanos , Transplante de Fígado/métodos , Doadores Vivos , Fenômenos Magnéticos , Veia Porta/diagnóstico por imagem , Veia Porta/cirurgia , Suínos , Veia Cava Inferior/cirurgia
9.
J Gastrointest Surg ; 25(12): 3033-3039, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34668164

RESUMO

PURPOSE: The magnetic compression technique (MCT) is a new surgical method that has been used for gastrointestinal anastomosis, choledochojejunostomy, and intestinal anastomosis, but there are no reports on its use for esophagogastric anastomosis. This study aimed to investigate the feasibility of using MCT to fashion esophagogastric anastomoses in rabbits. METHODS: Twenty rabbits were randomized into an MCT group (study group, n = 10) and a hand-sewn group (control group, n = 10). The magnetic compression anastomosis device used in this study was made of neodymium iron boron (NdFeB) and possessed parent (PMR) and daughter (DMR) magnetic rings. To fashion the anastomosis, the PMR and DMR were inserted into the lower esophagus and gastric fundus, respectively. The coupled magnets automatically compressed the sandwiched tissues and were expelled once the anastomosis was installed. The two groups were further compared in terms of the anastomosis construction time, survival rate, and postoperative complications. One month after the anastomosis was installed, the burst pressure and gross appearance of the anastomoses were evaluated. RESULTS: The anastomosis construction time in the study group was significantly shorter than that in the control group (10.50 ± 1.58 min vs. 18.60 ± 2.22 min; P < 0.05), and the magnetic rings were defecated out in 10.70 ± 3.49 days. The incidence of anastomotic blockage in both the study and control groups did not differ significantly (0%, 0/10 vs. 20%, 2/10; P > 0.05). Anastomotic leakage was not found in either of the groups, and the anastomoses burst pressures were similar in the two groups. However, the magnetically compressed anastomoses in the study group had a relatively smoother gross appearance than the hand-sewn anastomoses. CONCLUSION: The magnetic compression anastomosis device is a safe and feasible tool for fashioning esophagogastric anastomoses in this animal model.


Assuntos
Procedimentos Cirúrgicos do Sistema Digestório , Magnetismo , Animais , Coelhos , Anastomose Cirúrgica , Fenômenos Magnéticos , Imãs
11.
Sci Rep ; 10(1): 5981, 2020 04 06.
Artigo em Inglês | MEDLINE | ID: mdl-32249793

RESUMO

Magnetic compression anastomosis (MCA) has been appreciated as an innovative alternative to manual suturing in vascular reconstruction. However, magnetic devices have limitations in their applications. The present study aimed to introduce a newly developed magnetic device for end-to-end vascular anastomosis. Twenty male New Zealand rabbits were randomly assigned to receive end-to-end postcaval vein anastomosis using either a newly designed MCA device (Group MCA) or continuous-interrupted suturing (Group CIS). The anastomotic patency was evaluated by Doppler or venography immediately, 1 week, and 12 weeks after surgery. Anastomotic quality was evaluated gross and microscopic histological study 12 weeks after surgery. The procedure was successfully performed and all animals survived until sacrifice. The duration of surgery and anastomosis time in Group MCA were significantly shorter compared to Group CIS (all p < 0.001), and the incidence of anastomotic patency and postoperative morbidity were comparable between the two groups (all p > 0.05). Hematoxylin-eosin staining showed that anastomotic intima from Group MCA was much smoother with more regularly arranged endothelial cells than from compared to the Group CIS. A novel MCA device was successfully applied in rabbit vascular anastomosis. We demonstrated the reliability and effectiveness of this newly developed MCA in this study.


Assuntos
Anastomose Cirúrgica/métodos , Grau de Desobstrução Vascular/fisiologia , Veias/cirurgia , Animais , Magnetismo/métodos , Modelos Animais , Coelhos
12.
World J Surg ; 42(12): 4039-4045, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-29947988

RESUMO

BACKGROUND: Magnetic compression anastomosis (magnamosis, MCA) has been verified safe and effective by us and others in animal bilioenteric anastomosis (BEA). The objective of the present study was to introduce clinical application of magnetic compression bilioenteric anastomosis (MC-BEA) with a unique device in series of patients. METHODS: Patients with obstructive jaundice with an indication of BEA were prospectively enrolled from 2012 to 2015. After dissection of bile ducts, the mother ring and drainage tube were placed in the proximal bile duct and the purse-string suture was tightened over the drainage tube. The drainage tube was introduced into the jejunal lumen at the anastomotic site and used to guide the daughter ring to assemble with the mother ring. All the patients were routinely followed up for magnets discharge or any complications associated. RESULTS: Forty-one patients were included. Thirty-four (82.9%) patients had a malignant primary disease, while seven (17.1%) had benign disease. The median time for MC-BEA was 10.5 min (interquartile range [IQR] 8.3-13.0 min). No perioperative morbidity or mortality associated with MC-BEA was observed. The median time for a patent bilioenteric anastomosis formation was 19.0 days (IQR 14.5-23.0 days), and the magnets were discharged with a median postoperative duration of 35.0 days (IQR 28.0-43.0 days). With a median follow-up of 547.5 days (range 223-1042 days), no patients had biliary fistula, while two (4.9%) developed anastomotic stricture at 4 months and 14 months after surgery, and underwent reoperation for reconstruction of BEA. CONCLUSIONS: MCA is a safe, effective, and time-saving modality for biliojejunostomy.


Assuntos
Anastomose Cirúrgica/métodos , Ductos Biliares/cirurgia , Icterícia Obstrutiva/cirurgia , Jejunostomia/métodos , Imãs , Idoso , Anastomose Cirúrgica/efeitos adversos , Drenagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
13.
Int Urogynecol J ; 28(2): 241-247, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27530520

RESUMO

INTRODUCTION AND HYPOTHESIS: Rectovaginal fistula (RVF) is an abnormal epithelium-lined connection between the rectum and vagina. The primary effective treatment is surgical repair, but recurrence remains a challenge. Magnetic compression anastomosis (MCA), an alternative to suturing, has been developed to generate an anastomosis between various hollow viscera. We hypothesized that the MCA approach could be used to treat RVF. METHOD: We designed a novel MCA device for RVF treatment and evaluated the magnetic compression procedure in a RVF pig model in comparison with the traditional suturing procedure. Following satisfactory outcomes, we also applied the MCA procedure to a human patient with recurrent RVF. The MCA device was designed based on the anatomical characteristics of the pig vagina and previous literature. The pig RVF model were established surgically (n = 12), and compression and control groups were each treated. The data were analyzed by one-way analysis of variance. RESULTS: qqExcept in one animal in each group, the RVF site was smooth and healing was complete. Histological analysis confirmed complete healing of the RVF with high histological continuity to neighboring tissues. The compression procedure applied to our patient with RVF was successful. The patient recovered quickly without complications, and RVF did not recur during a 15-month follow-up. CONCLUSIONS: From this preliminary investigation, MCA using our novel device appears to be a safe, simple, and effective nonsurgical procedure for the treatment of RVF.


Assuntos
Imãs , Fístula Retovaginal/terapia , Procedimentos Cirúrgicos sem Sutura/instrumentação , Adulto , Canal Anal/cirurgia , Análise de Variância , Animais , Estudos de Casos e Controles , Desenho de Equipamento , Feminino , Humanos , Modelos Animais , Recidiva , Procedimentos Cirúrgicos sem Sutura/métodos , Suturas/efeitos adversos , Suínos , Resultado do Tratamento , Vagina/cirurgia , Cicatrização
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA