Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Bioanalysis ; 16(4): 233-243, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38334119

RESUMO

Aims: To develop and validate a UHPLC-MS/MS method for lamotrigine (LTG) analysis in human plasma and evaluate its agreement with a homogenous enzyme immunoassay (HEIA). Materials & methods: The UHPLC-MS/MS method was developed and validated according to the USFDA/EMA guidelines. A Bland-Altman plot was used to evaluate the agreement between UHPLC-MS/MS and HEIA. Results: Samples were pretreated with one-step protein precipitation and separated in 2.6 min. The intra- and inter-day bias and imprecisions were -15.8 to 15.0% and less than 11.17%, respectively. The recovery and matrix factor were 98.30 to 111.97%. The mean overestimation of UHPLC-MS/MS compared with HEIA was 21.57%. Conclusion: A rapid, sensitive and robust UHPLC-MS/MS method for plasma LTG analysis was developed and validated and was a 21.57% overestimation compared with HEIA.


Assuntos
Anticonvulsivantes , Espectrometria de Massas em Tandem , Humanos , Lamotrigina , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida de Alta Pressão/métodos , Técnicas Imunoenzimáticas , Imunoensaio/métodos , Reprodutibilidade dos Testes
2.
J Pharm Biomed Anal ; 158: 300-306, 2018 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-29909319

RESUMO

The plasma concentrations of methotrexate (MTX) and its major metabolite 7-hydroxy methotrexate (7-OH-MTX) are highly correlated with the toxicities in patients with high-dose MTX therapy. Routine monitoring of MTX and 7-OH-MTX plasma levels is useful for dose adjustment of rescue drugs and toxicity prevention. A UHPLC-MS/MS method for simultaneous determination of plasma MTX and 7-OH-MTX was developed, validated, and applied in 181 plasma samples. The ion transition was m/z 455.2 → 308.2 for MTX and m/z 471.2 → 324.1 for 7-OH-MTX. The flow rate was 0.4 mL/min with a run time of 2.6 min. The calibration range was 0.002-2 µM for MTX, and 0.01-10 µM for 7-OH-MTX. The intra-day and inter-day inaccuracy and imprecision were -5.50% to 10.93% and less than 9.20% for both analytes. The internal standard (MTX-D3) normalized recovery and matrix factor were consistent at four quality control levels. 14 h, 38 h, and 62 h after dosing, MTX and 7-OH-MTX plasma levels were significantly higher in patients with impaired renal function compared to those with normal renal function. 7-OH-MTX plasma levels were significantly higher in patients with impaired liver function compared to those with normal liver function.


Assuntos
Neoplasias do Sistema Nervoso Central/tratamento farmacológico , Monitoramento de Medicamentos/métodos , Antagonistas do Ácido Fólico/sangue , Linfoma não Hodgkin/tratamento farmacológico , Metotrexato/análogos & derivados , Calibragem , Neoplasias do Sistema Nervoso Central/sangue , Neoplasias do Sistema Nervoso Central/fisiopatologia , Cromatografia Líquida de Alta Pressão/instrumentação , Cromatografia Líquida de Alta Pressão/métodos , Relação Dose-Resposta a Droga , Monitoramento de Medicamentos/instrumentação , Antagonistas do Ácido Fólico/metabolismo , Antagonistas do Ácido Fólico/uso terapêutico , Humanos , Rim/fisiopatologia , Fígado/fisiopatologia , Linfoma não Hodgkin/sangue , Linfoma não Hodgkin/fisiopatologia , Masculino , Metotrexato/sangue , Metotrexato/metabolismo , Metotrexato/uso terapêutico , Sensibilidade e Especificidade , Espectrometria de Massas em Tandem/instrumentação , Espectrometria de Massas em Tandem/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA