RESUMO

BACKGROUND: Mitral stenosis (MS) is often concomitant with aortic stenosis (AS). However, little is known about the functional status following transcatheter aortic valve replacement (TAVR) alone in patients with severe AS and MS and the impact of TAVR for AS on MS hemodynamics. METHODS: We enrolled 11 patients (age 83.6±4.7 years, eight women) with severe AS and MS who underwent TAVR. We compared New York Heart Association (NYHA) functional class and mean transmitral pressure gradient (MPG), mitral valve area (MVA), and stroke volume (SV) measured by transthoracic Doppler echocardiography between baseline and after TAVR. We also examined the calcification of the mitral annulus and mitral leaflet opening. RESULTS: NYHA functional class improved after TAVR in all 11 patients. As SV increased after TAVR (52±12mL to 63±18mL, p=0.041), MPG decreased and MVA increased (6.9±3.8mmHg to 5.1±2.5mmHg, p=0.011 for MPG and 1.12±0.25cm2 to 1.49±0.43cm2, p=0.035 for MVA). However, MPG increased in one patient in whom calcification extended into the entire anterior mitral leaflet (AML) and AML mobility was severely reduced. CONCLUSIONS: NYHA functional class and hemodynamic status of MS improved after TAVR in patients with severe AS and MS. TAVR might provide therapeutic efficacy for selected symptomatic severe AS patients with MS.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Ecocardiografia Doppler , Hemodinâmica/fisiologia , Estenose da Valva Mitral/diagnóstico por imagem , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Calcinose/diagnóstico por imagem , Calcinose/etiologia , Feminino , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Estenose da Valva Mitral/fisiopatologia , Estenose da Valva Mitral/cirurgia , Período Pós-Operatório , Volume Sistólico , Resultado do Tratamento
2.
J Card Surg ; 33(4): 190-193, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29659089

RESUMO

A 48-year-old male developed a recurrent aortic-root pseudoaneurysm after surgical repair for acute dissection. Although the initial closure of the pseudoaneurysm was successfully managed by transcatheter endovascular occlusion and coiling utilizing a hybrid transapical and transfemoral approach, the pseudoaneurysm was recanalized after 3 months and a third-time surgical repair was required. The potential risk for recurrence of pseudoaneurysms should be considered when applying endovascular occlusion devices to treat aortic root anatomy.


Assuntos
Falso Aneurisma/cirurgia , Aorta/cirurgia , Aneurisma Aórtico/cirurgia , Doenças da Aorta/cirurgia , Dissecção Aórtica/cirurgia , Cateterismo Periférico/métodos , Embolização Terapêutica/métodos , Procedimentos Endovasculares/métodos , Doença Aguda , Aorta/anatomia & histologia , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Reoperação , Risco
3.
Ann Thorac Surg ; 103(2): e171-e173, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28109382

RESUMO

An 80-year-old man with symptomatic severe aortic stenosis underwent transcatheter aortic valve replacement. Postoperatively, the patient was hemodynamically stable without inotropic or mechanical support. Approximately 30 hours after the procedure, he developed severe abdominal pain, and a blood test result showed elevated serum lactate level. We suspected nonocclusive mesenteric ischemia and performed emergency selective angiography of the superior mesenteric artery, which showed vasospasm. We confirmed the diagnosis of nonocclusive mesenteric ischemia, and it was treated successfully with intraarterial infusion of vasodilators into the superior mesenteric artery.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Artéria Mesentérica Superior/efeitos dos fármacos , Isquemia Mesentérica/diagnóstico por imagem , Substituição da Valva Aórtica Transcateter/efeitos adversos , Vasodilatadores/uso terapêutico , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Seguimentos , Humanos , Infusões Intra-Arteriais , Masculino , Artéria Mesentérica Superior/diagnóstico por imagem , Isquemia Mesentérica/tratamento farmacológico , Isquemia Mesentérica/etiologia , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/tratamento farmacológico , Complicações Pós-Operatórias/fisiopatologia , Medição de Risco , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
4.
Gen Thorac Cardiovasc Surg ; 64(7): 365-72, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27138937

RESUMO

Recently, a development of devices for transcatheter interventions, such as transcatheter aortic valve implantation for aortic stenosis, percutaneous mitral valve repair for mitral regurgitation, and percutaneous closure of atrial septal defect, has led to a greatly expanded armamentarium of catheter-based approaches for patients with structural heart disease (SHD). Comorbidity and anatomical limitations specific to each procedure are known to influence outcomes during and after the intervention. Therefore, risk stratification of the intervention including anatomical and functional assessments is critically important. Furthermore, echocardiography reveals both physiological and anatomical abnormalities of SHD in real-time even in the operation theater. Consequently, echocardiography plays an essential role in providing not only preoperative assessment of SHD but also intra-procedural monitoring and postoperative follow-up. This document is intended as a reference for cardiac surgeons using echocardiography clinically for patients with SHD, particularly those with valvular heart disease and atrial septal defect.


Assuntos
Cardiomiopatias/diagnóstico por imagem , Ecocardiografia , Cardiopatias Congênitas/diagnóstico por imagem , Doenças das Valvas Cardíacas/diagnóstico por imagem , Assistência ao Convalescente/métodos , Cateterismo Cardíaco , Procedimentos Cirúrgicos Cardíacos/métodos , Cardiomiopatias/cirurgia , Cardiopatias Congênitas/cirurgia , Doenças das Valvas Cardíacas/cirurgia , Humanos , Monitorização Intraoperatória/métodos , Cuidados Pré-Operatórios/métodos , Ultrassonografia de Intervenção
5.
JACC Cardiovasc Imaging ; 8(9): 993-1003, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26319501

RESUMO

OBJECTIVES: The purpose of this study was to determine which echocardiographic parameters, including holodiastolic flow reversal (HDFR) in the descending aorta, were useful for grading of post-procedural aortic regurgitation (PAR) after transcatheter aortic valve replacement (TAVR) using intraprocedural transesophageal echocardiography. BACKGROUND: Reliable assessment of PAR in a catheterization laboratory is essential for an optimal outcome after TAVR; however, such an assessment has not been determined. METHODS: Three hundred eighty patients who underwent TAVR with the Edwards (Irvine, California) balloon-expandable transcatheter heart valve were retrospectively assessed by intraprocedural transesophageal echocardiography. PAR was evaluated by 2-dimensional color Doppler and pulse-wave Doppler in the descending aorta. Using 2-dimensional color Doppler, we measured the cross-sectional area of the vena contracta, the circumferential extent at the aortic annular plane, the longitudinal jet length, and the jet extent (with a mosaic pattern in the left ventricular outflow tract) compared with the location of the tip of the anterior mitral leaflet (AML). Grading of PAR was determined using the following vena contracta cutoffs: mild ≤9 mm(2); moderate 10 to 29 mm(2); and severe ≥30 mm(2). Significant PAR was defined as at least moderate grade. RESULTS: All patients with consistent HDFR had significant PAR. By multivariable analysis, consistent HDFR and the jet extent beyond the tip of AML were independent predictors of significant PAR. Consistent HDFR and jet extent beyond the tip of AML predicted significant PAR with specificities of 100% and 97%, respectively. In contrast, patients with both negative HDFR and a jet extent of less than halfway to the tip of AML had no significant PAR, with 97% specificity. CONCLUSIONS: The presence of consistent HDFR and jet extent beyond the tip of AML are indicative of significant PAR after TAVR.


Assuntos
Insuficiência da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/terapia , Valva Aórtica/diagnóstico por imagem , Cateterismo Cardíaco/efeitos adversos , Ecocardiografia Doppler em Cores , Ecocardiografia Doppler de Pulso , Ecocardiografia Transesofagiana , Implante de Prótese de Valva Cardíaca/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Distribuição de Qui-Quadrado , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Hemodinâmica , Humanos , Estimativa de Kaplan-Meier , Masculino , Análise Multivariada , Valor Preditivo dos Testes , Modelos de Riscos Proporcionais , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Resultado do Tratamento
6.
J Am Soc Echocardiogr ; 28(4): 404-14, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25560483

RESUMO

BACKGROUND: Determinants of paravalvular regurgitation after transcatheter aortic valve replacement (TAVR) remain unclear. The purpose of this study was to investigate the impact of aortic valve calcification (AVC) on paravalvular regurgitation after TAVR using real-time three-dimensional transesophageal echocardiography. METHODS: A total of 227 patients with severe aortic stenosis who underwent TAVR using the Edwards SAPIEN or SAPIEN XT valve were retrospectively analyzed. Severity of AVC was assessed on a visual scale ranging from 0 to 3 at the aortic annulus, the leaflets near the nadir, and the commissure. The shape of calcification was assessed by measuring the radial and circumferential lengths of annular calcification and by focusing on the calcification protruding into the left ventricular outflow tract from the annular level. Severity of paravalvular regurgitation was determined by the sum of the cross-sectional area of the vena contracta from two-dimensional or three-dimensional color Doppler transesophageal echocardiographic data. Significant paravalvular regurgitation was defined as at least a moderate grade. RESULTS: After excluding 25 patients with inadequate image quality of three-dimensional and color Doppler data for analysis, AVC could be evaluated in 202 patients. Significant paravalvular regurgitation was occurred in 37 patients (18%). The sum of the AVC scale at the annulus was significantly correlated with the grade of paravalvular regurgitation, while those at the leaflets near the nadir and the commissure were not. As assessed by receiver operating characteristic curve analysis, the radial and circumferential length of the annular calcification had good discriminatory ability for significant paravalvular regurgitation, with areas under the curve of 0.91 and 0.81, respectively. On multivariate analysis, annular calcification with radial length ≥ 3.0 mm, circumferential length ≥ 8.0 mm, and calcification protruding into the left ventricular outflow tract were independently associated with significant paravalvular regurgitation. CONCLUSIONS: Assessment of AVC by real-time three-dimensional transesophageal echocardiography is feasible and has good discriminatory value for paravalvular regurgitation in patients who undergo TAVR. Significant paravalvular regurgitation after TAVR is associated with the location and size of calcification at the aortic annulus and left ventricular outflow tract, not with its severity.


Assuntos
Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Calcinose/diagnóstico por imagem , Calcinose/etiologia , Ecocardiografia Tridimensional/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Sistemas Computacionais , Ecocardiografia Transesofagiana/métodos , Feminino , Humanos , Masculino , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
7.
J Cardiol Cases ; 12(1): 8-11, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30534268

RESUMO

We report a case of right ventricular (RV) diastolic dysfunction due to a large hematoma posterior to the left ventricle (LV) after cardiac surgery. An 80-year-old woman underwent cardiac surgery. After surgery, her physical findings revealed right heart failure. Localized hematoma posterior to the pericardial space and the RV compression to the sternum were shown by computed tomography. Transthoracic Doppler echocardiography demonstrated restrictive physiology of the RV although there was no evidence of constrictive pericarditis. These findings suggest that RV diastolic dysfunction could have occurred due to the hematoma posterior to the LV. Since pleural effusion had persisted despite medical therapy, the hematoma was removed surgically. Soon after surgery, dyspnea and pretibial edema were diminished; bilateral pleural effusion dramatically disappeared. RV diastolic dysfunction estimated by echocardiography was improved and RV compression disappeared. We speculate that there are two physiological mechanisms for the RV compression: (1) the localized hematoma elevated the intrapericardial pressure and (2) the hematoma shifted the entire heart to the sternum. In conclusion, this is the first case report of RV diastolic dysfunction due to large hematoma posterior to the LV. .

8.
Echocardiography ; 31(5): E142-4, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-25224213

RESUMO

Paravalvular regurgitation (PVR) after transcatheter aortic valve replacement (TAVR) is one of the major complications with negative clinical prognosis. Therefore, its prediction is important for further improvement of the outcome. We present a case with TAVR, in which we successfully evaluated aortic valve calcification protruding inward and into the left ventricular outflow tract by real time three-dimensional transesophageal echocardiography, and predicted significant PVR after the procedure. In conclusion, device landing zone calcification protruding inward is a key for the prediction of significant PVR after TAVR.


Assuntos
Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/complicações , Valva Aórtica/patologia , Calcinose/complicações , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico por imagem , Calcinose/diagnóstico por imagem , Diagnóstico Diferencial , Ecocardiografia Doppler em Cores , Feminino , Humanos , Complicações Pós-Operatórias , Desenho de Prótese , Falha de Prótese
9.
Eur Heart J Cardiovasc Imaging ; 15(12): 1324-32, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25187618

RESUMO

AIMS: We sought to optimize a method for quantification of the calcium in the aortic-valvar complex for the prediction of significant paravalvular leak (PVL) after transcatheter aortic valve implantation (TAVI). METHODS AND RESULTS: All patients had severe symptomatic aortic stenosis and were treated with balloon-expandable TAVI (Sapien/Sapien-XT, Edwards Lifesciences LLC, Irvine, CA, USA). In order to correct for precise annular sizing, only patients with available contrast computed tomography (CT) data for measurements were included (n = 198). Paravalvular leak was quantified using peri-procedural transoesophageal echocardiography by Valve Academic Research Consortium-2 (VARC-2) criteria (grade ≥ moderate was considered significant). A detailed region-of-interest methodology separated quantification of calcium in each of the aortic leaflets to that in the left ventricular outflow tract (LVOT) and was used to predict PVL in receiver operator characteristic curve analyses. For non-contrast scans, the greatest discriminatory value for PVL was seen at the 450 Hounsfield Unit (HU) threshold for detection (volume ≥626 mm(3)), whereas for contrast scans it was at 850 HU (≥235 mm(3)). Left ventricular outflow tract calcium predicted PVL but only as a binary variable with no incremental value of quantification. In a multivariable binary logistic regression model, annulus area ≥ prosthesis area (OR 3.5, 95% CI 1.5-8.2, P = 0.005), contrast leaflet calcium volume (850-HU threshold) ≥235 mm(3) (OR 2.8, 95% CI 1.2-6.7, P = 0.023), and presence of LVOT calcium (OR 2.8, 95% CI 1.2-7.0, P = 0.022) were independent predictors for PVL ≥ moderate. CONCLUSION: Both leaflet and LVOT calcium are significant predictors of PVL and exert an important synergistic influence on this complication, even in appropriately sized valves. With careful attention to thresholds for detection, clinically relevant leaflet calcium volumes can be identified with either non-contrast or contrast CT scans.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/química , Calcinose/diagnóstico , Cálcio/análise , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/patologia , Calcinose/diagnóstico por imagem , Meios de Contraste , Ecocardiografia Transesofagiana , Eletrocardiografia , Feminino , Próteses Valvulares Cardíacas/efeitos adversos , Humanos , Masculino , Valor Preditivo dos Testes , Desenho de Prótese , Falha de Prótese , Reprodutibilidade dos Testes , Fatores de Risco , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Fatores de Tempo , Tomografia Computadorizada por Raios X/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos
10.
Gen Thorac Cardiovasc Surg ; 62(4): 221-7, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24190549

RESUMO

OBJECTIVE: Chordal placement with no or minimal leaflet resection has been suggested as the preferred technique for mitral valve repair for posterior leaflet prolapse, because it creates a longer coaptation zone. However, whether or not a long coaptation zone improves the durability of mitral valve repairs remains unclear. METHODS: We reviewed 119 patients with chronic degenerative mitral regurgitation including posterior middle scallop prolapse who underwent mitral valve repair between June 2004 and July 2008. We divided them into two groups according to post-repair coaptation length ≥8 mm (group A) or <8 mm (group B). We assessed whether coaptation length is associated with recurrent mitral regurgitation at 1 year after surgery and increase in the regurgitant jet area over 1 year. RESULTS: The group A had a lower incidence of recurrent mitral regurgitation (4.7 vs 9.2%, p = 0.30), smaller increase in mitral regurgitant jet area over 1 year (0.29 vs 0.40 cm(2), p = 0.43), and higher 5-year freedom from recurrent mitral regurgitation (85.6 vs 76.1%, p = 0.76), although the differences were not statistically significant. The multivariate analysis showed that large coaptation length tends to be associated with decreased recurrent mitral regurgitation at 1 year (odds ratio 0.02, 95% confidence interval 0.00-3.67, p = 0.14). CONCLUSIONS: This study did not confirm the association between coaptation length and durability of mitral valve repair for posterior middle scallop prolapse. However, there was a trend towards decreased recurrent mitral regurgitation with larger coaptation length.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Insuficiência da Valva Mitral/cirurgia , Prolapso da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Adulto , Idoso , Ecocardiografia , Feminino , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Recidiva
11.
J Thorac Cardiovasc Surg ; 147(1): 321-5, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23228405

RESUMO

OBJECTIVE: A supra-annular aortic valve prosthesis is often used for aortic valve replacement in patients with a small aortic annulus. However, which suture technique provides the best valve performance has not been studied. We aimed to compare valve performance between 2 different suture techniques. METHODS: We reviewed 152 patients undergoing aortic valve replacement with a 19- or 21-mm Carpentier-Edwards Perimount Magna aortic bioprosthesis (Edwards Lifesciences, Irvine, Calif) between June 2008 and December 2010. Simple interrupted sutures were used in 102 patients (group A, 19-mm prosthesis in 47 patients and 21-mm prosthesis in 55 patients), and noneverting mattress sutures were used in 50 patients (group B, 19-mm prosthesis in 20 patients and 21-mm prosthesis in 30 patients). Transthoracic echocardiograms were performed at baseline and before discharge in all patients and 1 year after surgery in 141 patients. We compared the effective orifice area and incidence of prosthesis-patient mismatch (effective orifice area index <0.85 cm(2)/m(2)) between 2 groups. RESULTS: The mean postoperative effective orifice areas were 1.41 ± 0.32 cm(2)/m(2) in group A and 1.30 ± 0.28 cm(2)/m(2) in group B (P = .025). The incidence of prosthesis-patient mismatch was 29% in group A and 56% in group B (P = .002). A multivariate analysis has shown that simple interrupted suturing is a negative predictor of prosthesis-patient mismatch (odds ratio, 0.33; 95% confidence interval, 0.13-0.83; P = .018). At 1 year, the incidence of prosthesis-patient mismatch was 27% in group A and 47% in group B (P = .023). CONCLUSIONS: Simple interrupted sutures provide larger effective orifice areas and reduce the incidence of prosthesis-patient mismatch after aortic valve replacement with a small supra-annular bioprosthesis. This suture technique is preferred in those patients to maximize valve performance.


Assuntos
Valva Aórtica/cirurgia , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Técnicas de Sutura , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Ecocardiografia Doppler , Ecocardiografia Transesofagiana , Feminino , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Análise Multivariada , Razão de Chances , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
12.
J Am Soc Echocardiogr ; 26(8): 837-45, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23759167

RESUMO

BACKGROUND: Acute Stanford type A aortic dissection (AAD) with coronary involvement is associated with high mortality. However, coronary involvement is not always successfully visualized by computed tomography and two-dimensional (2D) transesophageal echocardiography (TEE). The aim of this study was to test the hypothesis that three-dimensional (3D) TEE can detect coronary involvement in patients with AAD. METHODS: Fifty-one consecutive patients with AAD who underwent intraoperative TEE using an iE33 system during emergency surgery were enrolled. Using computed tomographic images, conventional 2D transesophageal echocardiographic images, and a 3D transesophageal echocardiographic data set, the status of coronary ostia was evaluated and classified into four types-branching from true lumen, branching from false lumen, dissection, and unclear-and these results were compared with operative findings. RESULTS: In six patients, coronary involvement was diagnosed operatively by surgeons. They comprised dissection at three left coronary ostia and branching from false lumen at three right coronary ostia. All six cases were successfully detected by both 2D TEE and 3D TEE before instituting cardiopulmonary bypass. However, in 45 patients (90 ostia) confirmed operatively as having no coronary involvement, 69 ostia by computed tomography (36 in the left and 33 in the right coronary artery) and 16 ostia by 2D TEE (four in the left and 12 in the right coronary artery) were evaluated as unclear coronary involvement. On the other hand, 3D TEE clearly depicted no coronary involvement in all but one (right coronary ostium) of the unclear cases. CONCLUSIONS: Three-dimensional TEE reduced the number of cases evaluated as unclear coronary involvement by computed tomography and 2D TEE. In patients with AAD, 3D TEE allows evaluation of the status of coronary ostia in the operating room.


Assuntos
Aneurisma Aórtico/complicações , Aneurisma Aórtico/diagnóstico por imagem , Dissecção Aórtica/complicações , Dissecção Aórtica/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/etiologia , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
13.
Circ J ; 76(7): 1761-7, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22473457

RESUMO

BACKGROUND: Aortic stenosis (AS) is increasingly common in the elderly population. A recent invention of transcatheter aortic valve implantation tends to tilt the risk-benefit balance to favor earlier elective intervention for AS. Hence, decision making for elective intervention in octogenarians gradually becomes important. However, the outcome after elective aortic valve replacement (eAVR) has not been evaluated adequately. This study aimed to identify risk factors after eAVR in octogenarians and investigate their influence on long-term outcome. METHODS AND RESULTS: One hundred and thirty-seven consecutive Japanese octogenarians with AS who underwent eAVR were studied. The mean follow-up period was 35±22 (range, 0-88) months. Long-term overall survival rates after eAVR were 92.0%, 85.2% and 75.5% at 1, 3 and 5 years, respectively. Cox proportional hazards model identified age [hazard ratio (HR) 1.23; 95% confidence interval (CI) 1.07-1.43; P<0.01)] and ejection fraction (EF) <50% (HR 3.38; 95%CI 1.34-8.52; P<0.01) as the risk factors of mortality. Post-eAVR survival rates in octogenarians with an EF ≥50% and <50% were 97.3% and 70.4% at 1 year, 90.1% and 65.3% at 3 years, and 84.3% and 39.2% at 5 years, respectively (P<0.0001). CONCLUSIONS: Octogenarians with preserved LV systolic function before surgery have favorable long-term survival after eAVR. However, an EF <50% influences the mortality in octogenarian patients. Therefore, eAVR should be considered for octogenarians with AS before the progression of LV impairment.


Assuntos
Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca , Volume Sistólico , Disfunção Ventricular Esquerda/complicações , Função Ventricular Esquerda , Fatores Etários , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Progressão da Doença , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Mortalidade Hospitalar , Humanos , Japão , Estimativa de Kaplan-Meier , Masculino , Complicações Pós-Operatórias/etiologia , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Taxa de Sobrevida , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/mortalidade , Disfunção Ventricular Esquerda/fisiopatologia