Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
JBJS Case Connect ; 13(4)2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37943967

RESUMO

CASES: Three patients presented for orthopaedic surgery on glucagon-like peptide receptor agonist (GLP-1 RA) medications with a minimum fasting time of 10 hours. Gastric ultrasound confirmed the presence of retained solids in the stomach; all 3 cases were postponed. CONCLUSION: There is growing concern for increased perioperative aspiration risk related to delayed gastric emptying associated with GLP-1 RA and a paucity of literature to guide perioperative management. This may cause case cancellation over safety concerns for elective procedures. The presented cases illustrate the association of GLP-1 RA drugs and delayed gastric emptying causing case postponement.


Assuntos
Gastroparesia , Receptor do Peptídeo Semelhante ao Glucagon 1 , Humanos , Peptídeo 1 Semelhante ao Glucagon , Jejum
2.
Clin Orthop Relat Res ; 481(8): 1553-1559, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-36853864

RESUMO

BACKGROUND: Cobalt chromium (CoCr) is the most commonly used material in TKA; however, the use of oxidized zirconium (OxZr) implants has increased. The advantages to this material demonstrated in basic science studies have not been borne out in clinical studies to date. QUESTION/PURPOSE: In the setting of the American Joint Replacement Registry (AJRR), how do revision rates differ between CoCr and OxZr after primary TKA? METHODS: The AJRR was accessed for all primary TKAs performed between 2012 and 2020 for osteoarthritis, resulting in 441,605 procedures (68,506 with OxZr and 373,099 with CoCr). The AJRR is the largest joint replacement registry worldwide and collects procedure-specific details, making it ideal for large-scale comparisons of implant materials in the United States. Competing risk survival analyses were used to evaluate the all-cause revision rates of primary TKAs, comparing CoCr and OxZr implants. Data from the Centers for Medicare and Medicaid Services claims from 2012 to 2017 were also cross-referenced to capture additional revisions from other institutions. Revision rates were tabulated and subclassified by indication. Multivariate Cox regression was used to account for confounding variables such as age, gender, region, and hospital size. RESULTS: After controlling for confounding variables, there were no differences between the OxZr and CoCr groups in terms of the rate of all-cause revision at a mean follow-up of 46 ± 23 months and 44 ± 24 months for CoCr and OxZr implants, respectively (hazard ratio 1.055 [95% confidence interval 0.979 to 1.137]; p = 0.16) The univariate analysis demonstrated increased rates of revisions for pain and instability in the OxZr group (p = 0.003 and p < 0.001, respectively). CONCLUSION: These findings suggest there is no difference in all-cause revision between OxZr and CoCr implants in the short-term to mid-term. However, further long-term in vivo studies are needed to monitor the safety and all-cause revision rate of OxZr implants compared with those of CoCr implants. OxZr implants may be favorable in patients who have sensitivity to metal. Despite similar short-term to mid-term all-cause revision rates to CoCr implants, because of the limitations of this study, definitive recommendations for or against the use of OxZr cannot be made. LEVEL OF EVIDENCE: Level III, therapeutic study.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Humanos , Idoso , Estados Unidos , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Zircônio , Cobalto , Cromo , Desenho de Prótese , Medicare , Sistema de Registros , Reoperação , Falha de Prótese
3.
J Bone Joint Surg Am ; 105(1): 83-84, 2023 01 04.
Artigo em Inglês | MEDLINE | ID: mdl-35841319
4.
J Foot Ankle Surg ; 62(2): 282-285, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36117052

RESUMO

We examined outcomes following metatarsophalangeal joint cheilectomy with decompression osteotomy to evaluate the efficacy of this technique for treatment of hallux limitus/rigidus. At a minimum follow-up of 5 years, we identified 94 patients who fit the inclusion criteria. Chart review was performed to obtain range of motion (ROM) of the first metatarsophalangeal joint (MTPJ) preoperatively and at 6 weeks, 6 months, and 5 years postoperatively. Additionally, time to traditional shoe gear return, need for revision arthrodesis, radiographic findings, and postoperative visual analog scale (VAS) pain scores were reviewed. Statistical analysis was conducted by 1-way analysis of variance with post-hoc analysis and independent sample t-test. At an average follow-up of 6.3 ± 0.9 years, 42.3% (33/78) of females and 25.0% (4/16) of males reported limited ROM of the first MTPJ with 5 patients requiring first MTPJ arthrodesis. MTPJ ROM improved on average from 11.0° to 36.3° by 5-year minimum follow-up after surgery (p < .001). Analysis of variance revealed a significant difference of the preoperative ROM when compared to all postoperative time points (F[3,368] = 69.4, p < .001). Mean postoperative VAS pain scores after decompression osteotomy of the 5 patients who required MTPJ fusion were higher when compared to the rest of the patient cohort at final follow-up (7.4 ± 0.6 vs 1.5 ± 1.3; p < .001). Cheilectomy with decompression osteotomy for treatment of hallux limitus/rigidus leads to satisfactory long-term outcomes.


Assuntos
Hallux Limitus , Hallux Rigidus , Articulação Metatarsofalângica , Masculino , Feminino , Humanos , Estudos Retrospectivos , Hallux Rigidus/cirurgia , Osteotomia/métodos , Articulação Metatarsofalângica/cirurgia , Descompressão , Dor , Seguimentos , Resultado do Tratamento
5.
Pain ; 164(5): 1138-1147, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-36448974

RESUMO

ABSTRACT: Recovery from surgery is quicker in the postpartum period, and this may reflect oxytocin action in the spinal cord. We hypothesized that intrathecal injection of oxytocin would speed recovery from pain and disability after major surgery. Ninety-eight individuals undergoing elective total hip arthroplasty were randomized to receive either intrathecal oxytocin (100 µg) or saline. Participants completed diaries assessing pain and opioid use daily and disability weekly, and they wore an accelerometer beginning 2 weeks before surgery until 8 weeks after. Groups were compared using modelled, adjusted trajectories of these measures. The study was stopped early due to the lack of funding. Ninety patients received intrathecal oxytocin (n = 44) or saline (n = 46) and were included in the analysis. There were no study drug-related adverse effects. Modelled pain trajectory, the primary analysis, did not differ between the groups, either in pain on day of hospital discharge (intercept: -0.1 [95% CI: -0.8 to 0.6], P = 0.746) or in reductions over time (slope: 0.1 pain units per log of time [95% CI: 0-0.2], P = 0.057). In planned secondary analyses, postoperative opioid use ended earlier in the oxytocin group and oxytocin-treated patients walked nearly 1000 more steps daily at 8 weeks ( P < 0.001) and exhibited a clinically meaningful reduction in disability for the first 21 postoperative days ( P = 0.007) compared with saline placebo. Intrathecal oxytocin before hip replacement surgery does not speed recovery from worst daily pain. Secondary analyses suggest that further study of intrathecal oxytocin to speed functional recovery without worsening pain after surgery is warranted.


Assuntos
Analgésicos Opioides , Artroplastia de Quadril , Feminino , Humanos , Analgésicos Opioides/uso terapêutico , Dor Pós-Operatória/tratamento farmacológico , Dor Pós-Operatória/etiologia , Ocitocina/uso terapêutico , Artroplastia de Quadril/efeitos adversos , Resultado do Tratamento , Injeções Espinhais , Método Duplo-Cego , Morfina/uso terapêutico
6.
7.
Arthroplast Today ; 15: 1-5, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35342782

RESUMO

Background: Wound closure method in total hip and knee arthroplasty is a controversial topic with no differences in clinical outcomes between surgical staples (SS) and subcutaneous sutures with Dermabond (SCD). When clinically appropriate, providers should focus more on what the patient may prefer. This study aimed to collect data on patient preference between SS and SCD and analyze differences in preference based on gender and previous surgical histories. Methods: Patients were surveyed on their wound closure preferences prior to surgery. The handout given collected preference and patient demographics. Risk ratios and risk difference with 95% confidence intervals (95% CI) were calculated along with Firth-corrected logistic regressions. Results: A total of 163 participants were analyzed (53% female) (average age = 63.8 years), in which 12 participants selected SS as their preferred method. Males demonstrated no difference in relative risk (risk ratio: 2.3 [95% CI: 0.7, 7.3], P = .150) or absolute risk (risk difference: 5.9 [-2.2, 14.1], P = .156) in choosing SS over SCD. Patients that previously sustained SS for other surgeries demonstrated no difference in adjusted odds (adjusted: 0.9 [95% CI: 0.2, 3.2], P = .839) in choosing SS over SCD. Conclusion: More patients favored SCD over SS. There was no difference in preferences based on gender or previous surgical history. Current literature shows that successful wound closure is achieved with minimized risks for infection and other complications using both methods. Providers should adopt a patient-centric approach and perform the closure method that most patients prefer when medically warranted.

8.
Urology ; 163: 81-89, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34688772

RESUMO

OBJECTIVES: To assess the utility of genomic testing in risk-stratifying Black patients with low and intermediate risk prostate cancer. METHODS: We retrospectively identified 63 Black men deemed eligible for active surveillance based on National Comprehensive Cancer Network (NCCN) guidelines, who underwent OncotypeDx Genomic Prostate Score testing between April 2016 and July 2020. Nonparametric statistical testing was used to compare relevant features between patients reclassified to a higher NCCN risk after genomic testing and those who were not reclassified. RESULTS: The median age was 66 years and median pre-biopsy PSA was 7.3. Initial risk classifications were: very low risk: 7 (11.1%), low risk: 24(38.1%), favorable intermediate risk: 31(49.2%), and unfavorable intermediate risk: 1 (1.6%). Overall, NCCN risk classifications after Genomic Prostate Score testing were significantly higher than initial classifications (P=.003, Wilcoxon signed-rank). Among patients with discordant risk designations, 28(28/40, 70%) were reclassified to a higher NCCN risk after genomic testing. A pre-biopsy prostate specific antigen of greater than 10 did not have significantly higher odds of HBR (OR:2.16 [95% CI: 0.64,7.59, P=.2). Of favorable intermediate risk patients, 20(64.5%) were reclassified to a higher NCCN risk. Ultimately, 18 patients underwent definitive treatment. CONCLUSIONS: Incorporation of genomic testing in risk stratifying Black men with low and intermediate-risk prostate cancer resulted in overall higher NCCN risk classifications. Our findings suggest a role for increased utilization of genomic testing in refining risk-stratification within this patient population. These tests may better inform treatment decisions on an individualized basis.


Assuntos
Neoplasias da Próstata , Idoso , Testes Genéticos , Humanos , Masculino , Gradação de Tumores , Antígeno Prostático Específico , Neoplasias da Próstata/genética , Neoplasias da Próstata/patologia , Estudos Retrospectivos , Medição de Risco/métodos
9.
J Surg Orthop Adv ; 30(3): 166-169, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34591006

RESUMO

The sterility of the gown-glove interface during total joint arthroplasty is a key factor in preventing contamination of the surgical field. To compare the potential of gown-glove interface contamination with a novel gloving technique versus standard gloving technique. We performed a study quantifying potential gown-glove interface contamination using two different gloving techniques. A 5 µm fluorescent powder simulated potential bacterial contamination. Each group gowned and gloved each hand using a modified technique versus traditional technique. Ultraviolet light was used to measure contamination at the gown-glove interface after performing a simulated surgery. The modified gloving technique did not statistically reduce the contamination at the gown-glove interface compared to the traditional gloving technique (p = 0.27). Despite using a gloving technique recently described as decreasing contamination, we noted contamination at the interface after performing a simulated surgery with a positive pressure exhaust suit. Further study is needed. (Journal of Surgical Orthopaedic Advances 30(3):166-169, 2021).


Assuntos
Luvas Cirúrgicas , Roupa de Proteção , Humanos
10.
Curr Rev Musculoskelet Med ; 14(5): 316-319, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34581989

RESUMO

PURPOSE OF REVIEW: The surgical community is constantly working to improve accuracy and reproducibility in patient care, with the goal to improve patient outcomes and efficiency. One area of growing interest with potential to meet these goals is in the use of augmented reality (AR) in surgery. There is still a paucity of published research on the clinical benefits of AR over traditional techniques, but this article aims to present an update on the current state of AR within orthopaedics over the past 5 years. RECENT FINDINGS: AR systems are being developed and studied for use in all areas of orthopaedics. Most recently published research has focused on the areas of fracture care, adult reconstruction, orthopaedic oncology, spine, and resident education. These studies have shown some promising results, particularly in surgical accuracy, decreased surgical time, and less radiation exposure. However, the majority of recently published research is still in the pre-clinical setting, with very few studies using living patients. AR supplementation in orthopaedic surgery has shown promising results in pre-clinical settings, with improvements in surgical accuracy and reproducibility, decreased operating times, and less radiation exposure. Most AR systems, however, are still not approved for clinical use. Further research is needed to validate the benefits of AR use in orthopaedic surgery before it is widely adopted into practice.

11.
J Urol ; 204(5): 976-981, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32459602

RESUMO

PURPOSE: Ureteral access sheaths are commonly used during ureteroscopy to facilitate stone removal, improve visibility and maintain low intrarenal pressures. However, the use of a ureteral access sheath can cause ureteral wall ischemia and ureteral tears, potentially increasing the risk of postoperative ureteral stricture and obstruction. We studied the impact of ureteral access sheath use on postoperative imaging studies. Secondary objectives included studying the impact of other intraoperative parameters on postoperative imaging studies. MATERIALS AND METHODS: A retrospective chart review was conducted of cases that underwent ureteroscopy for nephroureterolithiasis across 2 high volume institutions between January 2012 and September 2016. Patient demographics, cumulative stone size, operative time, use of ureteral access sheath, laser lithotripsy, basket extraction, preoperative ureteral stent and postoperative ureteral stent placement were extracted from the electronic medical record. Findings of followup renal ultrasound, kidney-ureter-bladder x-ray and/or computerized tomography at approximately 8 weeks after surgery were recorded. RESULTS: A total of 1,332 ureteroscopies were performed with 1,060 cases (79.6%) returning for routine upper tract imaging after ureteroscopy. Postoperative hydronephrosis was noted following 127 cases (12.0%). Factors predicting presence of hydronephrosis after ureteroscopy include lower body mass index (p=0.0016), greater cumulative stone size (p=0.0003), increased operative time (p <0.0001), preoperative ureteral stent (OR 1.49, p=0.0299) and postoperative ureteral stent placement (OR 6.43, p=0.0031). Postoperative hydronephrosis was not associated with use of ureteral access sheath, age, laser lithotripsy or basket extraction. CONCLUSIONS: Use of ureteral access sheath did not have a significant impact on development of postoperative hydronephrosis, suggesting ureteral access sheath is safe for use during ureteroscopy. Ureteral strictures remain rare following ureteroscopy, seen in only 1.0% of our cohort. With an observed prevalence of hydronephrosis of 12.0% on followup imaging at 8 weeks, routine upper tract imaging after ureteroscopy remains a valuable prognostic tool.


Assuntos
Hidronefrose/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Ureteroscópios/efeitos adversos , Ureteroscopia/efeitos adversos , Urolitíase/cirurgia , Adulto , Idoso , Índice de Massa Corporal , Feminino , Seguimentos , Humanos , Hidronefrose/diagnóstico por imagem , Hidronefrose/etiologia , Incidência , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Fatores de Risco , Stents/efeitos adversos , Tomografia Computadorizada por Raios X , Ureteroscopia/instrumentação
13.
Arthroplast Today ; 4(4): 452-453, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30569008

RESUMO

Total knee arthroplasty is a successful surgery for the majority of patients with osteoarthrosis of the knee. Approximately 5% of patients undergoing total knee arthroplasty experience loss of motion or arthrofibrosis. Manipulation under anesthesia (MUA) is generally indicated for patients who do not achieve >90° of flexion by 6-12 weeks postoperatively. Complications from MUA are rare but can be devastating. We describe a novel technique for MUA with no reported major complications in our review of 78 patients. The average flexion improved from 80.0 (±3.8) before manipulation to 115.4 (±2.1) after manipulation. There were no major complications including fracture or extensor mechanism injury.

14.
Nurs Clin North Am ; 50(2): 293-314, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25999072

RESUMO

Preventable adverse events and other medical errors occur to hundreds of thousands of Americans every year. The financial burden of these preventable events is estimated to be $29 billion. According to the World Health Organization, reducing medical errors has become an international concern. Protecting patients from harm is a primary responsibility of all nurses regardless of whether the nurse works in the intensive care unit or operating room. Adherence to policies to maintain patient safety can be discerned once the level of knowledge of these policies among nurses is determined.


Assuntos
Conhecimento , Recursos Humanos de Enfermagem Hospitalar , Transporte de Pacientes , Fidelidade a Diretrizes , Humanos , Erros Médicos/prevenção & controle , Transferência da Responsabilidade pelo Paciente , Estados Unidos
15.
Am J Orthop (Belle Mead NJ) ; 43(1): E19-24, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24490189

RESUMO

This study sought to determine whether templating for metal-on-metal hip resurfacing is more accurate with digital or acetate methodology. The medical records of 102 consecutive patients who underwent hip resurfacing at our institution were retrospectively reviewed. Records lacking preoperative radiographs that included a magnification-establishing marker were excluded, leaving 78 records for study. Two investigators independently prepared acetate and digital templates of the preoperative radiographs, which had been calibrated to 120% magnification, to predict femoral and acetabular component size. Accuracy was measured by comparing the predicted component sizes to the surgically implanted component sizes. Digital templating was more accurate than acetate templating in predicting hip resurfacing component size when measuring accuracy of templates by the absolute error of predicted component sizes (femoral, P < .001; acetabular, P = .002), and by the prediction of components to +/-1 size difference (femoral, P = .001; acetabular, P = .002). Experience of the templating surgeon did not correlate with templating accuracy for acetate or digital templating. Although acetate templating is often regarded as the "gold standard" in preoperative planning, data from the current study shows that digital technology can be used for accurate preoperative templating prior to hip resurfacing procedures.


Assuntos
Articulação do Quadril/diagnóstico por imagem , Procedimentos Ortopédicos/métodos , Osteoartrite do Quadril/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Articulação do Quadril/cirurgia , Humanos , Osteoartrite do Quadril/cirurgia , Cuidados Pré-Operatórios/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos
16.
J Urol ; 191(6): 1899-1905, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24291546

RESUMO

PURPOSE: SDF-1 is a ligand of the chemokine receptors CXCR4 and 7. The 6 known SDF-1 isoforms are generated by alternative mRNA splicing. While SDF-1 expression has been detected in various malignancies, only few groups have reported differential expression of SDF-1 isoforms and its clinical significance. We evaluated the expression of 3 SDF-1 isoforms (α, ß and γ) in bladder cancer. MATERIALS AND METHODS: Using quantitative polymerase chain reaction we measured SDF-1α, ß and γ mRNA levels in 25 normal and 44 bladder cancer tissues, and in 210 urine specimens (28 normal, 74 benign, 57 bladder cancer, 35 bladder cancer history, 8 other cancer history and 8 other cancer) from consecutive patients. Levels were correlated with clinical outcome. RESULTS: Of the SDF-1 isoforms only SDF-1ß mRNA was significantly over expressed 2.5-fold to sixfold in bladder cancer compared to normal bladder tissues. SDF-1α was expressed in bladder tissues but SDF-1γ was undetectable. On multivariate analysis SDF-1ß was an independent predictor of metastasis and disease specific mortality (p=0.017 and 0.043, respectively). In exfoliated urothelial cells only SDF-1ß mRNA levels were differentially expressed with 91.2% sensitivity and 73.8% specificity for detecting bladder cancer. In patients with a bladder cancer history increased SDF-1ß levels indicated a 4.3-fold increased risk of recurrence within 6 months (p=0.0001). CONCLUSIONS: SDF-1 isoforms are differentially expressed in bladder tissues and exfoliated urothelial cells. SDF-1ß mRNA levels in bladder cancer tissues predict a poor prognosis. Furthermore, SDF-1ß mRNA levels in exfoliated cells detect bladder cancer with high sensitivity and they are a potential predictor of future recurrence.


Assuntos
Quimiocina CXCL12/genética , Regulação Neoplásica da Expressão Gênica , RNA Neoplásico/genética , Neoplasias da Bexiga Urinária/genética , Adulto , Biomarcadores Tumorais/biossíntese , Biomarcadores Tumorais/genética , Quimiocina CXCL12/biossíntese , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isoformas de Proteínas , Reação em Cadeia da Polimerase em Tempo Real , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Neoplasias da Bexiga Urinária/metabolismo , Neoplasias da Bexiga Urinária/patologia
18.
J Pediatr Surg ; 47(8): 1566-71, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22901918

RESUMO

BACKGROUND: Segmental absence of the intestinal musculature (SAIM) is a known but clinically rare entity involving partial or complete absence of the intestinal muscularis propria. Clinical presentation is consistent with peritonitis, and treatment involves an emergent laparotomy, bowel resection, and reanastamosis or possible ostomy creation. Diagnosis results from histopathologic evaluation of the resected intestinal specimen. Most of the publications are case reports. METHODS: We retrospectively reviewed all surgical pathology files at a tertiary pediatric hospital from 2003 to 2010, identifying children who were noted to have absence of intestinal musculature on pathology. Patients meeting criteria were reviewed in detail, and data regarding clinical presentation, diagnostic testing, radiologic findings, treatment, and outcome were recorded. RESULTS: Five patients were identified between 2003 and 2010 who received the diagnosis of SAIM. Patient age ranged from 1 to 99 days of life. All children were born preterm by cesarean section, had a mean birth weight of 828 ± 338 g, and were intubated after birth. CONCLUSIONS: The 5 patients presented are reviewed and contrasted with previous cases presented in the literature. Theories of pathogenesis and classification are discussed, and the cases are labeled as primary versus secondary SAIM.


Assuntos
Doenças do Prematuro/epidemiologia , Intestinos/anormalidades , Músculo Liso/anormalidades , Abdome Agudo/etiologia , Anormalidades Múltiplas/epidemiologia , Adulto , Cesárea , Anormalidades do Sistema Digestório/diagnóstico , Anormalidades do Sistema Digestório/epidemiologia , Anormalidades do Sistema Digestório/cirurgia , Permeabilidade do Canal Arterial/tratamento farmacológico , Permeabilidade do Canal Arterial/epidemiologia , Evolução Fatal , Feminino , Humanos , Indometacina/efeitos adversos , Indometacina/uso terapêutico , Lactente , Recém-Nascido , Recém-Nascido Prematuro , Doenças do Prematuro/diagnóstico , Doenças do Prematuro/cirurgia , Perfuração Intestinal/etiologia , Masculino , Idade Materna , Pneumoperitônio/etiologia , Gravidez , Estudos Retrospectivos , Sepse/etiologia
19.
Int Urol Nephrol ; 44(2): 409-14, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21706214

RESUMO

BACKGROUND: Ureteral access sheaths (UAS) are used to facilitate ureteroscopic procedures. Difficulties in use, including sheath distortion, buckling, and difficulty in placement, have been reported. However, few clinical comparisons have been performed. We present the first large-scale comparison of the Applied ForteXE(®) and ACMI-Gyrus Uropass(®) UAS. METHODS: We retrospectively compared patients who underwent ureteroscopy for urolithiasis with one of two types of UAS: Applied Forte XE(®) or ACMI-Gyrus Uropass(®). Demographics, operative parameters, and outcomes were assessed. Statistical analysis was performed. RESULTS: In 125 (64.4%) male and 69 (35.6%) female patients, 194 UAS were used. One hundred and thirteen (58.2%) Applied Forte XE(®) and 81 (41.8%) ACMI-Gyrus Uropass(®) were utilized. Success rates for sheath deployment were as follows: overall = 186/194 (95.8%); Applied Forte XE(®) = 107/113 (94.7%); and ACMI-Gyrus Uropass(®) = 79/81 (97.5%) (P = 0.472). Of the 194 patients 131 (67.5%) had a pre-existing stent. Sheath deployment failures occurred in 7 men and 1 woman, of which 4/8 (50%) had no pre-existing stent. Limitations of deployed sheaths occurred at low frequency in both Applied Forte XE 17/107 (15.9%) and ACMI-Gyrus 6/79 (7.6%), with no significant difference observed (P = 0.120). Limitations in use was high in men (P = 0.019). At a mean follow-up of 41 months, no ureteral strictures were noted. CONCLUSIONS: No significant differences were seen in overall success rates for both sheaths. Both sheaths had high deployment success rates and a similar low frequency of sheath-related limitations. We noted increased limitations in the use of deployed sheaths in men. Successful sheath use may depend on both the sheath itself and patient/operative parameters.


Assuntos
Ureteroscópios , Ureteroscopia/métodos , Urolitíase/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Desenho de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Urolitíase/diagnóstico , Adulto Jovem
20.
Arthroscopy ; 27(7): 1005-13, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21498032

RESUMO

Femoroacetabular impingement has recently become a recognized cause of disability and hip arthritis. Hip arthroscopy and femoroacetabular reshaping have been performed to treat this condition. Quantification of the excess femoral and acetabular bone requiring resection has been challenging with the less invasive arthroscopic technique. We describe the use of intraoperative computed tomography assessing osteochondroplasty during arthroscopic surgery to treat cam- and pincer-type femoroacetabular impingement. We also describe the technical steps and present the important radiologic findings we have been able to visualize. We found intraoperative computed tomography scanning to be a reliable and reproducible method of assessing the quality of femoroacetabular impingement surgery. We believe that femoroacetabular impingement surgery can be assessed intraoperatively by use of computed tomography scanning where corrections can be made if necessary.


Assuntos
Artroscopia , Impacto Femoroacetabular/diagnóstico por imagem , Impacto Femoroacetabular/cirurgia , Cuidados Intraoperatórios , Cirurgia Assistida por Computador , Tomografia Computadorizada por Raios X , Adolescente , Feminino , Humanos , Cuidados Intraoperatórios/normas , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/normas , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA