Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Infect Control Hosp Epidemiol ; 39(12): 1436-1441, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30345942

RESUMO

OBJECTIVE: To determine the continued need for active surveillance to prevent extended-spectrum ß-lactamase-producing Enterobacteriaceae (ESBL-E) transmission in a neonatal intensive care unit (NICU). DESIGN: This retrospective observational study included patients with ESBL-E colonization or infection identified during their NICU stay at our institution between 1999 and March 2018. Active surveillance was conducted between 1999 and March 2017 by testing rectal swab specimens collected upon admission and weekly thereafter. The overall incidence rates, of ESBL-E colonization or infection (including hospital acquired) before and after active surveillance were calculated. The cost associated with active surveillance was then estimated. RESULTS: Overall, 171 NICU patients were found to have ESBL-E colonization or infection, and 150 of those patients (87.7%) were detected by active surveillance. The overall incidence rate was 1.4 per 100 patient admissions. The hospital-acquired incidence rate was 0.41 per 1,000 patient days, and this rate had decreased since 2002, with an average of 6 cases detected annually. A significant decrease was observed in 2009 when the unit moved to a new single-bed unit featuring private rooms. Active surveillance was discontinued with no increase in the number of infections. Of the 150 ESBL-E colonized patients, 14 (9.3%) subsequently developed an infection. Active surveillance resulted in a total of 50,950 specimen collections and a cost of $127,187 for processing, an average of $848 to detect 1 ESBL-E colonized patient. CONCLUSION: ESBL-E transmission and infection in our NICU remains uncommon. Active surveillance may have contributed to the decline of ESBL-E transmission when used in conjunction with contact precautions and private rooms, but its relatively high cost could be prohibitive.


Assuntos
Enterobacteriáceas Resistentes a Carbapenêmicos/isolamento & purificação , Portador Sadio/microbiologia , Infecção Hospitalar/diagnóstico , Infecções por Enterobacteriaceae/diagnóstico , Controle de Infecções/métodos , Portador Sadio/epidemiologia , Infecção Hospitalar/epidemiologia , Infecção Hospitalar/prevenção & controle , Infecções por Enterobacteriaceae/epidemiologia , Infecções por Enterobacteriaceae/prevenção & controle , Feminino , Humanos , Recém-Nascido , Unidades de Terapia Intensiva Neonatal , Masculino , Programas de Rastreamento/estatística & dados numéricos , Estudos Retrospectivos
2.
J Pediatr Surg ; 49(8): 1202-5, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25092076

RESUMO

BACKGROUND/PURPOSE: Infants with severe chronic lung disease (sCLD) may require surgical procedures to manage their medical problems; however, the scope of these interventions is undefined. The purpose of this study was to characterize the frequency, type, and timing of operative interventions performed in hospitalized infants with sCLD. METHODS: The Children's Hospital Neonatal Database was used to identify infants with sCLD from 24 children's hospital's NICUs hospitalized over a recent 16-month period. RESULTS: 556 infants were diagnosed with sCLD; less than 3% of infants had operations prior to referral and 30% were referred for surgical evaluation. In contrast, 71% of all sCLD infants received ≥1 surgical procedure during the CHND NICU hospitalization, with a mean of 3 operations performed per infant. Gastrostomy insertion (24%), fundoplication (11%), herniorrhaphy (13%), and tracheostomy placement (12%) were the most commonly performed operations. The timing of gastrostomy (PMA 48±10 wk) and tracheostomy (PMA 47±7 wk) insertions varied, and for infants who received both devices, only 33% were inserted concurrently (13/40 infants). CONCLUSIONS: A striking majority of infants with sCLD received multiple surgical procedures during hospitalizations at participating NICUs. Further work regarding the timing, coordination, perioperative complications, and clinical outcomes for these infants is warranted.


Assuntos
Doenças do Prematuro/cirurgia , Recém-Nascido Prematuro , Unidades de Terapia Intensiva Neonatal , Pneumopatias/cirurgia , Complicações Pós-Operatórias/epidemiologia , Procedimentos Cirúrgicos Operatórios/métodos , Doença Crônica , Feminino , Humanos , Incidência , Recém-Nascido , Doenças do Prematuro/diagnóstico , Pneumopatias/diagnóstico , Masculino , Índice de Gravidade de Doença , Taxa de Sobrevida/tendências , Estados Unidos/epidemiologia
3.
Am J Perinatol ; 31(3): 223-30, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23690052

RESUMO

OBJECTIVES: To characterize postnatal growth failure (PGF), defined as weight < 10th percentile for postmenstrual age (PMA) in preterm (≤ 27 weeks' gestation) infants with severe bronchopulmonary dysplasia (sBPD) at specified time points during hospitalization, and to compare these in subgroups of infants who died/underwent tracheostomy and others. STUDY DESIGN: Retrospective review of data from the multicenter Children's Hospital Neonatal Database (CHND). RESULTS: Our cohort (n = 375) had a mean ± standard deviation gestation of 25 ± 1.2 weeks and birth weight of 744 ± 196 g. At birth, 20% of infants were small for gestational age (SGA); age at referral to the CHND neonatal intensive care unit (NICU) was 46 ± 50 days. PGF rates at admission and at 36, 40, 44, and 48 weeks' PMA were 33, 53, 67, 66, and 79% of infants, respectively. Tube feedings were administered to > 70% and parenteral nutrition to a third of infants between 36 and 44 weeks' PMA. At discharge, 34% of infants required tube feedings and 50% had PGF. A significantly greater (38 versus 17%) proportion of infants who died/underwent tracheostomy (n = 69) were SGA, compared with those who did not (n = 306; p < 0.01). CONCLUSIONS: Infants with sBPD commonly had progressive PGF during their NICU hospitalization. Fetal growth restriction may be a marker of adverse outcomes in this population.


Assuntos
Displasia Broncopulmonar/fisiopatologia , Transtornos do Crescimento/etiologia , Aumento de Peso , Displasia Broncopulmonar/complicações , Displasia Broncopulmonar/terapia , Feminino , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Masculino , Estudos Retrospectivos , Traqueostomia
4.
Environ Health Perspect ; 112(13): 1339-40, 2004 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-15345350

RESUMO

Di(2-ethylhexyl) phthalate (DEHP) is used to make polyvinyl chloride (PVC) plastic tubing soft and flexible. Animal data show that adverse effects of DEHP exposure may include reduced fertility, reduced sperm production in males, and ovarian dysfunction in females. Known treatments that involve high DEHP exposures are blood exchange transfusions, extracorporeal membrane oxygenation (ECMO), and cardiovascular surgery. Although potential exposure to DEHP in ECMO patients is significant, the exposure has not been associated with short-term toxicity. To evaluate long-term toxicity, we undertook a study of neonatal ECMO survivors to assess their onset of puberty and sexual maturity. We evaluated 13 male and 6 female subjects at 14-16 years of age who had undergone ECMO as neonates. All subjects had a complete physical examination including measurements for height, weight, head circumference, and pubertal assessment by Tanner staging. The testicular volume and the phallic length were measured in male participants. Laboratory tests included thyroid, liver, and renal function as well as measurements of luteinizing hormone, follicle-stimulating hormone, testosterone for males, and estradiol for females. Except for one patient with Marfan syndrome, the rest had normal growth percentile for age and sex. All had normal values for thyroid, liver, and renal functions. Sexual hormones were appropriate for the stage of pubertal maturity. Our results indicate that adolescents exposed to significant quantities of DEHP as neonates showed no significant adverse effects on their physical growth and pubertal maturity. Thyroid, liver, renal, and male and female gonadal functions tested were within normal range for age and sex distribution. Key Words: DEHP, ECMO, toxicity.


Assuntos
Desenvolvimento Infantil/efeitos dos fármacos , Oxigenação por Membrana Extracorpórea/efeitos adversos , Adolescente , Dietilexilftalato , Equipamentos Médicos Duráveis , Feminino , Seguimentos , Gônadas/crescimento & desenvolvimento , Humanos , Recém-Nascido , Masculino , Puberdade
5.
J Perinatol ; 22(6): 472-4, 2002 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-12168125

RESUMO

INTRODUCTION: The ability to measure postmembrane arterial blood gases is essential in the management of critically ill neonates treated with extracorporeal membrane oxygenation (ECMO). A new technology using, the Paratrend 7 system (Diametrics Medical, High Wycombe,UK) allows for continuous measurement of pH, PCO(2) and PO(2), and calculates oxygen saturation, bicarbonate, and base excess. OBJECTIVE: To evaluate and compare the results of continuous blood gas measurement using the Paratrend 7 system with a standard system of blood gas analysis in our intensive care unit. DESIGN: Prospective, controlled, interventional study. SETTING: The neonatal intensive care unit of a tertiary referral center. PATIENTS: Neonates who required extracorporeal life support and were expected to have frequent postmembrane arterial blood sampling during the testing period. RESEARCH DESIGN AND METHOD: To enable Paratrend 7 sensor access to the ECMO circuit, the postmembrane access port extension set that is routinely used for blood drawn for blood gas analysis was used. The study began with the insertion of the Paratrend 7 sensor. Subjects remained on the study until the ECMO was discontinued and/or frequent blood gases were no longer needed. The blood gas results from the Paratrend 7 system were not used in clinical management of the patient. BLOOD GAS MEASUREMENT: During the study period, with each blood sample drawn for laboratory analysis, a printout from the Paratrend 7 monitor was recorded for comparison. RESULTS: A total of 242 pairs of blood gas samples were collected from 10 neonates. The mean bias/precision for pH was -0.02/0.04; for PO(2) 68.35/93.44 mm Hg; and for PCO(2) 1.75/4.23 mm Hg. The correlation (r value) between the sensor reading and the blood gases were 0.89 for pH, 0.96 for PO(2), and 0.73 for PCO(2) (Table 1). CONCLUSION: The blood gases compared in the two methods had a strong correlation for pH, PCO(2) and PO(2). Results of this study indicate that this technology provides an accurate means of monitoring continuous blood gas parameters in neonatal ECMO patients. Use of the Paratrend 7 should allow reduced health-care provider exposure to blood and decreased patient iatrogenic blood loss.


Assuntos
Gasometria/métodos , Oxigenação por Membrana Extracorpórea/métodos , Monitorização Fisiológica/instrumentação , Oxigênio/sangue , Síndrome do Desconforto Respiratório do Recém-Nascido/sangue , Artérias , Gasometria/instrumentação , Cateteres de Demora , Cuidados Críticos/métodos , Estado Terminal , Feminino , Humanos , Recém-Nascido , Unidades de Terapia Intensiva Neonatal , Masculino , Monitorização Fisiológica/métodos , Consumo de Oxigênio/fisiologia , Estudos Prospectivos , Troca Gasosa Pulmonar , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia , Sensibilidade e Especificidade
6.
J Perinatol ; 22(5): 367-9, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12082470

RESUMO

INTRODUCTION: Arterial blood gases are essential in the management of critically ill neonates. A new technology using the Neotrend system (Diametrics Medical) allows for continuous measurement of pH, PaCO(2), and PaO(2), and calculates oxygen saturation, bicarbonate, and base excess. OBJECTIVE: To evaluate and compare the results of continuous blood gas measurement using the Neotrend system with a standard system of blood gas analysis in our intensive care unit. DESIGN: Prospective, controlled, interventional study. SETTING: The neonatal intensive care unit of a tertiary referral center. PATIENTS: Neonates with respiratory distress who required respiratory support and frequent arterial blood gas sampling and had a UAC. RESEARCH DESIGN AND METHOD: To enable Neotrend sensor access to an existing Argyle umbilical artery catheter (UAC) the catheter was cut at the 25-cm mark and connected to an 18-gauge blunt needle luer stub adaptor (Vygon 95440). The study began with the insertion of the Neotrend sensor. Subjects remained on the study until the UAC was discontinued and/or frequent blood gases were no longer needed. The blood gas results from the Neotrend system were not used in clinical management of the patient. BLOOD GAS MEASUREMENT: During the study period, with each blood sample drawn for laboratory analysis, a printout from the Neotrend monitor was recorded for comparison. RESULTS: A total of 217 pairs of blood gas samples were collected from seven neonates. The mean bias/precision for pH was 0.01/0.04; for PaO(2) 0.72/18.5 mm Hg; and for PaCO(2) 3.96/2.63 mm Hg. The correlation (r value) between the sensor reading and the blood gases were 0.85 for pH, 0.96 for PaO(2), and 0.92 for PaCO(2). CONCLUSION: The blood gases compared in the two methods had a strong correlation for pH, PaCO(2), PaO(2), and oxygen saturation. Although the bicarbonate and base excess values showed suboptimal statistical correlation, the difference was not clinically relevant. Results of this study indicate that this technology provides an accurate means of monitoring continuous blood gas parameters in neonatal patients. It also allows reduced healthcare provider exposure to blood and decreased patient iatrogenic blood loss.


Assuntos
Gasometria/métodos , Cateteres de Demora , Humanos , Recém-Nascido , Monitorização Fisiológica/métodos , Estudos Prospectivos , Artérias Umbilicais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA