Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Molecules ; 28(9)2023 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-37175205

RESUMO

Glioblastoma (GBM) is the most aggressive brain tumor, with high mortality. Timosaponin AIII (TIA), a steroidal saponin isolated from the medicinal plant Anemarrhena asphodeloides Bge., has been shown to possess anticancer properties in various cancer types. However, the effect of TIA on GBM is unknown. In this study, we reveal that TIA not only inhibited U87MG in vitro cell growth but also in vivo tumor development. Moreover, we found that the cause of TIA-induced cell growth suppression was apoptosis. When seeking to uncover antitumor mechanisms of TIA, we found that TIA diminished the expression of cGMP-specific phosphodiesterase 5(PDE5) while elevating the levels of guanylate cyclases (sGCß), cellular cGMP, and phosphorylation of VASPser239. Following the knockdown of PDE5, PDE5 inhibitor tadalafil and cGMP analog 8-Bro-cGMP both inhibited cell growth and inactivated ß-catenin; we reason that TIA elicited an antitumor effect by suppressing PDE5, leading to the activation of the cGMP signaling pathway, which, in turn, impeded ß-catenin expression. As ß-catenin is key for cell growth and survival in GBM, this study suggests that TIA elicits its anti-tumorigenic effect by interfering with ß-catenin function through the activation of a PDE5/cGMP functional axis.


Assuntos
Glioblastoma , beta Catenina , Humanos , beta Catenina/metabolismo , Glioblastoma/tratamento farmacológico , Esteroides/farmacologia , Apoptose , Transdução de Sinais , GMP Cíclico/metabolismo
2.
Materials (Basel) ; 14(4)2021 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-33557236

RESUMO

The hot deformation behaviors of the SJTU-1 alloy, the high-throughput scanned casting Nickel-based superalloy, was investigated by compression test in the temperature range of 900 to 1200 °C and strain rate range of 0.1-0.001 s-1. The hot processing map has been constructed with the instability zone. At the beginning of hot deformation, the flow stress moves rapidly to the peak value with the increased strain rates. Meanwhile, the peak stress is decreased with the increased temperature at the same strain rates. However, the peak stress shows the same tendency with the strain rates at the same temperature. The optimum hot deformation condition was determined in the temperature range of 1000-1075 °C, and the strain rate range of 0.005-0.1 s-1. The microstructure investigation indicates the strain rate significantly affects the characteristics of the microstructure. The deformation constitutive equation has also been discussed as well.

3.
Turk Neurosurg ; 24(4): 598-601, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25050690

RESUMO

Although intracranial multiple aneurysms are not uncommon, multiple mirror aneurysms are relatively rare. A few isolated cases have been described. However, to the best of our knowledge, 3 pairs of pure symmetrical mirror aneurysms in one patient have not been reported yet. We present a case of multiple mirror aneurysms involving the bilateral middle cerebral artery (MCA) bifurcations and posterior communicating arteries (P-com A) confirmation by one-stage operation. The possibility of one-stage treatment must be considered before surgery. Missed diagnosis and misdiagnosis must be avoided before one-stage operation for multiple mirror aneurysms.


Assuntos
Aneurisma Intracraniano/cirurgia , Procedimentos Neurocirúrgicos/métodos , Idoso , Craniotomia , Imagem de Difusão por Ressonância Magnética , Feminino , Humanos , Aneurisma Intracraniano/complicações , Aneurisma Intracraniano/patologia , Artéria Cerebral Média/patologia , Artéria Cerebral Média/cirurgia , Hemorragia Subaracnóidea/cirurgia , Tomografia Computadorizada por Raios X
4.
World J Surg Oncol ; 12: 190, 2014 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-24957053

RESUMO

BACKGROUND: This study aimed to evaluate the accuracy of surgical outcomes in free iliac crest mandibular reconstructions that were carried out with virtual surgical plans and rapid prototyping templates. METHODS: This study evaluated eight patients who underwent mandibular osteotomy and reconstruction with free iliac crest grafts using virtual surgical planning and designed guiding templates. Operations were performed using the prefabricated guiding templates. Postoperative three-dimensional computer models were overlaid and compared with the preoperatively designed models in the same coordinate system. RESULTS: Compared to the virtual osteotomy, the mean error of distance of the actual mandibular osteotomy was 2.06 ± 0.86 mm. When compared to the virtual harvested grafts, the mean error volume of the actual harvested grafts was 1412.22 ± 439.24 mm3 (9.12% ± 2.84%). The mean error between the volume of the actual harvested grafts and the shaped grafts was 2094.35 ± 929.12 mm3 (12.40% ± 5.50%). CONCLUSIONS: The use of computer-aided rapid prototyping templates for virtual surgical planning appears to positively influence the accuracy of mandibular reconstruction.


Assuntos
Ameloblastoma/cirurgia , Transplante Ósseo , Desenho Assistido por Computador , Ílio/transplante , Neoplasias Mandibulares/cirurgia , Osteotomia , Procedimentos de Cirurgia Plástica , Adulto , Ameloblastoma/patologia , Feminino , Seguimentos , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Neoplasias Mandibulares/patologia , Pessoa de Meia-Idade , Prognóstico , Tomografia Computadorizada por Raios X , Adulto Jovem
5.
Ultrason Sonochem ; 21(4): 1275-8, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24433976

RESUMO

Cavitation bubbles in Al-10 wt.%Cu melt has been investigated by adopting synchrotron radiation X-ray imaging technology. In-situ observation reveals that most of bubbles concentrate within an intense cavitation zone nearby the radiation face. The measured near-maximum bubble radii obey a similar truncated Gaussian distribution as in water but increase by nearly the magnitude of one order due to higher ultrasonic intensity applied in aluminum melt.

6.
J Oral Maxillofac Surg ; 71(10): 1712-23, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23911146

RESUMO

PURPOSE: This study sought to introduce 3-dimensional (3D) virtual surgical planning and digital rapid-prototyping templates for zygomaticomaxillary complex (ZMC) injuries associated with orbital volume change and to evaluate the surgical outcomes quantitatively. PATIENTS AND METHODS: Eight patients who underwent open reduction and fixation for a ZMC injury with orbital volume change were studied. Computed tomographic (CT) scan of the zygomaticomaxillary area was performed before the operation in each case. Scanned data were converted into 3D models using Mimics software (Materialise, Brussels, Belgium) for surgical designs. Virtual surgical reductions and correlated guiding templates were designed using Mimics and Magics software (Materialise). The operations were performed with the help of prefabricated templates to reduce the fractures. A postoperative CT scan of each patient was obtained within 2 weeks after surgery, and quantitative measurements were made to assess the surgical outcomes. Preoperative volumes of the bilateral orbits were compared, and concordance with postoperative volumes of the bilateral orbits was assessed. Twenty-one pairs of distances from 7 marker points to 3 reference planes were measured to assess postoperative facial symmetry. RESULTS: Volumes of the injured orbits were significantly different from volumes of the uninjured orbits preoperatively (P < .05), whereas bilateral orbital volumes showed no statistically significant difference postoperatively (P > .05). In addition, 19 of the 21 pairs of bilateral distances showed no significant difference postoperatively (P > .05). CONCLUSIONS: Quantitative assessment showed that digitally designed, rapid-prototyping templates for ZMC fractures have a positive impact on restoring facial symmetry and concordance of bilateral orbital volumes.


Assuntos
Desenho Assistido por Computador , Fraturas Maxilares/cirurgia , Fraturas Orbitárias/cirurgia , Planejamento de Assistência ao Paciente , Interface Usuário-Computador , Fraturas Zigomáticas/cirurgia , Adulto , Pontos de Referência Anatômicos/diagnóstico por imagem , Cefalometria/métodos , Feminino , Seguimentos , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Fraturas Cominutivas/diagnóstico por imagem , Fraturas Cominutivas/cirurgia , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Luxações Articulares/diagnóstico por imagem , Luxações Articulares/cirurgia , Masculino , Fraturas Maxilares/diagnóstico por imagem , Pessoa de Meia-Idade , Modelos Anatômicos , Órbita/diagnóstico por imagem , Fraturas Orbitárias/diagnóstico por imagem , Tamanho do Órgão , Cirurgia Assistida por Computador , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento , Adulto Jovem , Fraturas Zigomáticas/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA