Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Pers Med ; 12(7)2022 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-35887588

RESUMO

OBJECTIVES: To evaluate short- and long-term safety and efficacy of embolization with Onyx® for recurrent pulmonary arteriovenous malformations (PAVMs) in hereditary hemorrhagic telangiectasia (HHT). METHODS: In total, 45 consecutive patients (51% women, mean (SD) age 53 (18) years) with HHT referred to a reference center for treatment of recurrent PAVM were retrospectively included from April 2014 to July 2021. Inclusion criteria included evidence of PAVM recurrence on CT or angiography, embolization using Onyx® and a minimal 1-year-follow-up CT or angiography. Success was defined based on the standard of reference criteria on unenhanced CT or pulmonary angiography if a recurrence was suspected. PAVMs were analyzed in consensus by two radiologists. The absence of safety distance, as defined by a too-short distance for coil/plug deployment, i.e., between 0.5 and 1 cm, between the proximal extremity of the primary embolic material used and a healthy upstream artery branch, was reported. RESULTS: In total, 70 PAVM were analyzed. Mean (SD) follow-up was 3 (1.3) years. Safety distance criteria were missing in 33 (47%) PAVMs. All procedures were technically successful, with a short-term occlusion rate of 100% using a mean (SD) of 0.6 (0.5) mL of Onyx®. The long-term occlusion rate was 60%. No immediate complication directly related to embolization was reported, nor was any severe long-term complication such as strokes or cerebral abscesses. CONCLUSIONS: In HHT, treatment of recurrent PAVM with Onyx® showed satisfactory safety and efficacy, with an immediate occlusion rate of 100% and a long-term rate of 60%.

2.
Eur Radiol ; 32(6): 4292-4303, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35029730

RESUMO

OBJECTIVES: To compare the lung CT volume (CTvol) and pulmonary function tests in an interstitial lung disease (ILD) population. Then to evaluate the CTvol loss between idiopathic pulmonary fibrosis (IPF) and non-IPF and explore a prognostic value of annual CTvol loss in IPF. METHODS: We conducted in an expert center a retrospective study between 2005 and 2018 on consecutive patients with ILD. CTvol was measured automatically using commercial software based on a deep learning algorithm. In the first group, Spearman correlation coefficients (r) between forced vital capacity (FVC), total lung capacity (TLC), and CTvol were calculated. In a second group, annual CTvol loss was calculated using linear regression analysis and compared with the Mann-Whitney test. In a last group of IPF patients, annual CTvol loss was calculated between baseline and 1-year CTs for investigating with the Youden index a prognostic value of major adverse event at 3 years. Univariate and log-rank tests were calculated. RESULTS: In total, 560 patients (4610 CTs) were analyzed. For 1171 CTs, CTvol was correlated with FVC (r: 0.86) and TLC (r: 0.84) (p < 0.0001). In 408 patients (3332 CT), median annual CTvol loss was 155.7 mL in IPF versus 50.7 mL in non-IPF (p < 0.0001) over 5.03 years. In 73 IPF patients, a relative annual CTvol loss of 7.9% was associated with major adverse events (log-rank, p < 0.0001) in univariate analysis (p < 0.001). CONCLUSIONS: Automated lung CT volume may be an alternative or a complementary biomarker to pulmonary function tests for the assessment of lung volume loss in ILD. KEY POINTS: • There is a good correlation between lung CT volume and forced vital capacity, as well as for with total lung capacity measurements (r of 0.86 and 0.84 respectively, p < 0.0001). • Median annual CT volume loss is significantly higher in patients with idiopathic pulmonary fibrosis than in patients with other fibrotic interstitial lung diseases (155.7 versus 50.7 mL, p < 0.0001). • In idiopathic pulmonary fibrosis, a relative annual CT volume loss higher than 9.4% is associated with a significantly reduced mean survival time at 2.0 years versus 2.8 years (log-rank, p < 0.0001).


Assuntos
Fibrose Pulmonar Idiopática , Doenças Pulmonares Intersticiais , Humanos , Fibrose Pulmonar Idiopática/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Doenças Pulmonares Intersticiais/diagnóstico por imagem , Medidas de Volume Pulmonar , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Capacidade Vital
3.
Radiology ; 300(1): 98-107, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33944628

RESUMO

Background Macrophage burden is a major factor in the risk of atherosclerotic plaque rupture, and its evaluation remains challenging with molecular noninvasive imaging approaches. Photon-counting CT (PCCT) with k-edge imaging aims to allow for the specific detection of macrophages using gold nanoparticles. Purpose To perform k-edge imaging in combination with gold nanoparticles to detect and quantify the macrophage burden within the atherosclerotic aortas of rabbits. Materials and Methods Atherosclerotic and control New Zealand white rabbits were imaged before and at several time points up to 2 days after intravenous injection of gold nanoparticles (3.5 mL/kg, 65 mg gold per milliliter). Aortic CT angiography was performed at the end of the follow-up using an intravenous injection of an iodinated contrast material. Gold k-edge and conventional CT images were reconstructed for qualitative and quantitative assessment of the macrophage burden. PCCT imaging results were compared with findings at histologic examination, quantitative histomorphometry, transmission electron microscopy, and quantitative inductively coupled plasma optical emission spectrometry. Pearson correlations between the macrophage area measured in immunostained sections and the concentration of gold and attenuation measured in the corresponding PCCT sections were calculated. Results Seven rabbits with atherosclerosis and four control rabbits without atherosclerosis were analyzed. In atherosclerotic rabbits, calcifications were observed along the aortic wall before injection. At 2 days after injection of gold nanoparticles, only gold k-edge images allowed for the distinction of plaque enhancement within calcifications and for lumen enhancement during angiography. A good correlation was observed between the gold concentration measured within the wall and the macrophage area in 35 plaques (five per rabbit) (r = 0.82; 95% CI: 0.67, 0.91; P < .001), which was higher than that observed on conventional CT images (r = 0.41; 95% CI: 0.09, 0.65; P = .01). Transmission electron microscopy and inductively coupled plasma optical emission spectrometry analyses confirmed the gold k-edge imaging findings. Conclusion Photon-counting CT with gold nanoparticles allowed for the noninvasive evaluation of both molecular and anatomic information in vivo in rabbits with atherosclerotic plaques. Published under a CC BY 4.0 license. Online supplemental material is available for this article. See also the editorial by Leiner in this issue.


Assuntos
Doenças da Aorta/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Placa Aterosclerótica/diagnóstico por imagem , Animais , Aorta/diagnóstico por imagem , Modelos Animais de Doenças , Ouro , Macrófagos , Nanopartículas Metálicas , Fótons , Coelhos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA