Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Cochrane Database Syst Rev ; 5: CD010333, 2024 05 30.
Artigo em Inglês | MEDLINE | ID: mdl-38813836

RESUMO

BACKGROUND: Infants in the neonatal intensive care unit (NICU) are subjected to different types of stress, including sounds of high intensity. The sound levels in NICUs often exceed the maximum acceptable level recommended by the American Academy of Pediatrics, which is 45 decibels (dB). Hearing impairment is diagnosed in 2% to 10% of preterm infants compared to only 0.1% of the general paediatric population. Bringing sound levels under 45 dB can be achieved by lowering the sound levels in an entire unit; by treating the infant in a section of a NICU, in a 'private' room, or in incubators in which the sound levels are controlled; or by reducing sound levels at the individual level using earmuffs or earplugs. By lowering sound levels, the resulting stress can be diminished, thereby promoting growth and reducing adverse neonatal outcomes. This review is an update of one originally published in 2015 and first updated in 2020. OBJECTIVES: To determine the benefits and harms of sound reduction on the growth and long-term neurodevelopmental outcomes of neonates. SEARCH METHODS: We used standard, extensive Cochrane search methods. On 21 and 22 August 2023, a Cochrane Information Specialist searched CENTRAL, PubMed, Embase, two other databases, two trials registers, and grey literature via Google Scholar and conference abstracts from Pediatric Academic Societies. SELECTION CRITERIA: We included randomised controlled trials (RCTs) or quasi-RCTs in preterm infants (less than 32 weeks' postmenstrual age (PMA) or less than 1500 g birth weight) cared for in the resuscitation area, during transport, or once admitted to a NICU or stepdown unit. We specified three types of intervention: 1) intervention at the unit level (i.e. the entire neonatal department), 2) at the section or room level, or 3) at the individual level (e.g. hearing protection). DATA COLLECTION AND ANALYSIS: We used the standardised review methods of Cochrane Neonatal to assess the risk of bias in the studies. We used the risk ratio (RR) and risk difference (RD), with their 95% confidence intervals (CIs), for dichotomous data. We used the mean difference (MD) for continuous data. Our primary outcome was major neurodevelopmental disability. We used GRADE to assess the certainty of the evidence. MAIN RESULTS: We included one RCT, which enroled 34 newborn infants randomised to the use of silicone earplugs versus no earplugs for hearing protection. It was a single-centre study conducted at the University of Texas Medical School in Houston, Texas, USA. Earplugs were positioned at the time of randomisation and worn continuously until the infants were 35 weeks' postmenstrual age (PMA) or discharged (whichever came first). Newborns in the control group received standard care. The evidence is very uncertain about the effects of silicone earplugs on the following outcomes. • Cerebral palsy (RR 3.00, 95% CI 0.15 to 61.74)and Mental Developmental Index (MDI) (Bayley II) at 18 to 22 months' corrected age (MD 14.00, 95% CI 3.13 to 24.87); no other indicators of major neurodevelopmental disability were reported. • Normal auditory functioning at discharge (RR 1.65, 95% CI 0.93 to 2.94) • All-cause mortality during hospital stay (RR 2.07, 95% CI 0.64 to 6.70; RD 0.20, 95% CI -0.09 to 0.50) • Weight (kg) at 18 to 22 months' corrected age (MD 0.31, 95% CI -1.53 to 2.16) • Height (cm) at 18 to 22 months' corrected age (MD 2.70, 95% CI -3.13 to 8.53) • Days of assisted ventilation (MD -1.44, 95% CI -23.29 to 20.41) • Days of initial hospitalisation (MD 1.36, 95% CI -31.03 to 33.75) For all outcomes, we judged the certainty of evidence as very low. We identified one ongoing RCT that will compare the effects of reduced noise levels and cycled light on visual and neural development in preterm infants. AUTHORS' CONCLUSIONS: No studies evaluated interventions to reduce sound levels below 45 dB across the whole neonatal unit or in a room within it. We found only one study that evaluated the benefits of sound reduction in the neonatal intensive care unit for hearing protection in preterm infants. The study compared the use of silicone earplugs versus no earplugs in newborns of very low birth weight (less than 1500 g). Considering the very small sample size, imprecise results, and high risk of attrition bias, the evidence based on this research is very uncertain and no conclusions can be drawn. As there is a lack of evidence to inform healthcare or policy decisions, large, well designed, well conducted, and fully reported RCTs that analyse different aspects of noise reduction in NICUs are needed. They should report both short- and long-term outcomes.


Assuntos
Recém-Nascido Prematuro , Recém-Nascido de muito Baixo Peso , Unidades de Terapia Intensiva Neonatal , Ruído , Ensaios Clínicos Controlados Aleatórios como Assunto , Humanos , Recém-Nascido , Recém-Nascido Prematuro/crescimento & desenvolvimento , Ruído/efeitos adversos , Recém-Nascido de muito Baixo Peso/crescimento & desenvolvimento , Som , Dispositivos de Proteção das Orelhas , Viés , Perda Auditiva Provocada por Ruído/prevenção & controle
2.
Cochrane Database Syst Rev ; 10: CD013158, 2023 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-37882216

RESUMO

BACKGROUND: Administration of various exogenous surfactant preparations has been shown to decrease lung injury and pneumothorax and improve survival in very preterm infants with respiratory distress syndrome (RDS). There is no consensus on the threshold for surfactant administration, to allow timely intervention and avoid over-treatment, also considering the invasiveness of the procedure and its cost. Rapid tests for lung maturity, which include the click test, lamellar body counts and stable microbubble test, might guide the identification of those infants needing surfactant administration. OBJECTIVES: To assess the effects of surfactant treatment guided by rapid tests for surfactant deficiency in preterm infants at risk for or having RDS. Comparison 1: In preterm infants at risk for RDS, does surfactant treatment guided by rapid tests for surfactant deficiency compared to prophylactic surfactant administration to all high-risk infants minimize the need for surfactant treatment and prevent bronchopulmonary dysplasia and mortality? Comparison 2: In preterm infants who require early respiratory support, does surfactant treatment guided by rapid tests for surfactant deficiency compared to surfactant therapy provided to infants with RDS diagnosed on clinical and radiologic criteria minimize the need for surfactant treatment and prevent bronchopulmonary dysplasia and mortality? SEARCH METHODS: We searched in October 2022 CENTRAL, PubMed, Embase and three additional trial registries. We also screened the reference lists of included studies and related systematic reviews for studies not identified by the database searches. SELECTION CRITERIA: We included randomized controlled trials (RCTs) and quasi-RCTs evaluating rapid tests after birth for surfactant deficiency in infants at high risk of RDS or requiring respiratory support. We specified two comparisons: 1)surfactant treatment guided by rapid tests for surfactant deficiency versus prophylactic surfactant administration to all high-risk infants in extremely preterm (less than 28 weeks' gestation) and very preterm (28 to 32 weeks' gestation); 2)surfactant treatment guided by rapid tests for surfactant deficiency versus surfactant therapy provided to preterm infants (less than 37 weeks' gestation) with RDS diagnosed on clinical and radiologic criteria. DATA COLLECTION AND ANALYSIS: We used standard Cochrane methods. We used the fixed-effect model with risk ratio (RR) and risk difference (RD), with their 95% confidence intervals (CIs) for dichotomous data. Our primary outcomes were: neonatal mortality, mortality prior to hospital discharge, bronchopulmonary dysplasia and the composite outcome bronchopulmonary dysplasia or mortality. We used GRADE to assess the certainty of evidence. MAIN RESULTS: We included three RCTs enrolling 562 newborn infants in this review. No studies compared surfactant treatment guided by rapid tests for surfactant deficiency versus prophylactic surfactant administration to all high-risk infants. Comparing surfactant therapy guided by rapid tests for surfactant deficiency versus surfactant therapy provided to infants with RDS diagnosed on clinical and radiologic criteria. No studies reported neonatal mortality. Compared with surfactant therapy provided to infants with RDS diagnosed on clinical and radiologic criteria, the evidence is very uncertain about the effect of surfactant treatment guided by rapid tests for surfactant deficiency on mortality prior to hospital discharge: RR 1.25, 95% CI 0.65 to 2.41, RD 0.01, 95% CI -0.03 to 0.05, 562 participants, 3 studies; I² for RR and RD = 75% and 43%, respectively; very low-certainty evidence. Surfactant treatment guided by rapid tests for surfactant deficiency may result in little to no difference in bronchopulmonary dysplasia: RR 0.90, 95% CI 0.61 to 1.32, RD -0.02, 95% CI -0.08 to 0.04, 562 participants, 3 studies; I² for RR and RD = 0%; low-certainty evidence. No studies reported the composite outcome bronchopulmonary dysplasia or mortality. Surfactant treatment guided by rapid tests for surfactant deficiency may result in little to no difference in surfactant utilization (RR 0.97, 95% CI 0.85 to 1.11, RD -0.02, 95% CI -0.10 to 0.06, 562 participants, 3 studies, I² for RR and RD = 63% and 65%, respectively, low-certainty evidence), and any pneumothorax (RR 0.53, 95% CI 0.15 to 1.92, RD -0.01, 95% CI -0.04 to 0.01, 506 participants, 2 studies, I² for RR and RD = 0%, low-certainty evidence) compared with surfactant therapy provided to infants with RDS diagnosed on clinical and radiologic criteria. No studies reported moderate to severe neurodevelopmental impairment. We identified two large ongoing RCTs. AUTHORS' CONCLUSIONS: No studies compared surfactant treatment guided by rapid tests for surfactant deficiency to prophylactic surfactant administration to all high-risk infants. Low to very low-certainty evidence from three studies is available on surfactant therapy guided by rapid tests for surfactant deficiency versus surfactant therapy provided to infants with RDS diagnosed on clinical and radiologic criteria. No studies reported neonatal mortality, the composite outcome 'bronchopulmonary dysplasia or mortality', or neurodevelopmental outcomes. Compared with surfactant therapy provided to infants with RDS diagnosed on clinical and radiologic criteria, the evidence is very uncertain about the effect of surfactant treatment guided by rapid tests for surfactant deficiency on mortality prior to hospital discharge. Surfactant treatment guided by rapid tests for surfactant deficiency may result in little to no difference in bronchopulmonary dysplasia, surfactant utilization and any pneumothorax. The findings of the two large ongoing trials identified in this review are likely to have an important impact on establishing the effects of surfactant treatment guided by rapid tests for surfactant deficiency in preterm infants.


Assuntos
Displasia Broncopulmonar , Pneumotórax , Surfactantes Pulmonares , Síndrome do Desconforto Respiratório do Recém-Nascido , Recém-Nascido , Lactente , Humanos , Tensoativos/uso terapêutico , Displasia Broncopulmonar/prevenção & controle , Pneumotórax/prevenção & controle , Recém-Nascido Prematuro , Síndrome do Desconforto Respiratório do Recém-Nascido/tratamento farmacológico , Síndrome do Desconforto Respiratório do Recém-Nascido/prevenção & controle , Surfactantes Pulmonares/uso terapêutico , Pulmão
3.
Biomedicines ; 10(10)2022 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-36289684

RESUMO

Masses of the head and neck are often diagnosed prenatally and require special care due to the risk of airway obstruction. The EXIT procedure is a preferable mode of delivery. A congenital cystic lymphatic malformation is one of the most common lesions of the cervical region described in neonates. The treatment consists of different strategies and involves the cooperation of multiple specialists. Up to now, no guidelines or protocols are available. We report a case of a congenital cystic lymphatic malformation of the head and neck delivered during the EXIT procedure by a mother who was SARS-CoV-2 positive. We analyzed clinical characteristics, radiologic features, and treatment with injections of sclerotic agents and orally administrated sirolimus. Sirolimus seems a valuable and safe therapeutic option for treating lymphatic malformations, especially with adjunct therapies.

4.
J Electrocardiol ; 55: 87-90, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31152996

RESUMO

INTRODUCTION: HIV patients are at higher risk for cardiovascular disease and cardiac arrhythmias which can be recorded by a handheld single­lead ECG device. Quality of ECG depends on the skin condition, which worsens with the progression of HIV infection. OBJECTIVE: To study the quality of the ECG signal acquired by a mobile ECG device in patients with different clinical stages of human immunodeficiency virus (HIV) infection. PATIENTS AND METHODS: We studied the quality of 30-second single lead ECGs obtained by a handheld ECG device (Kardia; AliveCor Inc., San Francisco, USA) in 263 Kenyan adults (203 women) in various stages of HIV. The recordings were made during routine check-ups at the outpatient clinics. ECG quality was categorized as readable (not interfering with clinical interpretation) or unreadable (impossible clinical interpretation). The progression of the HIV infection was estimated using the World Health Organization AIDS Clinical Staging (WACS) scale, ranging from stage 1 (asymptomatic generalized lymphadenopathy) to stage 4 (wasting syndrome and Kaposi sarcoma). RESULTS: The median age of patients was 46 (39-53) years. ECG was readable in 201 patients (76.4%) and unreadable in 62 (23.6%). The WACS score > 1 was associated with 3.95 odds ratio (95% confidence interval 2.14-7.29; p < 0.0001) for the acquiring an unreadable ECG (univariate logistic regression adjusted to age, sex, body mass index and time since HIV). CONCLUSIONS: ECG quality recorded by a touch ECG device worsens with advancing HIV infection. For this reason, the accuracy of arrhythmia diagnosis by mobile ECG appears to be limited in HIV patients.


Assuntos
Síndrome da Imunodeficiência Adquirida , Infecções por HIV , Síndrome da Imunodeficiência Adquirida/complicações , Adulto , Eletrocardiografia , Feminino , Infecções por HIV/complicações , Humanos , Quênia , Pessoa de Meia-Idade , Tato
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA