Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Int J Cardiovasc Imaging ; 40(2): 213-224, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37891450

RESUMO

PURPOSE: Mitral valve prolapse (MVP) is associated with left ventricle (LV) fibrosis, including the papillary muscles (PM), which is in turn linked to malignant arrhythmias. This study aims to evaluate comprehensive tissue characterization of the PM by cardiovascular magnetic resonance (CMR) imaging and its association with LV fibrosis observed by intraoperative biopsies. METHODS: MVP patients with indication for surgery due to severe mitral regurgitation (n = 19) underwent a preoperative CMR with characterization of the PM: dark-appearance on cine, T1 mapping, conventional bright blood (BB) and dark blood (DB) late gadolinium enhancement (LGE). CMR T1 mapping was performed on 21 healthy volunteers as controls. LV inferobasal myocardial biopsies were obtained in MVP patients and compared to CMR findings. RESULTS: MVP patients (54 ± 10 years old, 14 male) had a dark-appearance of the PM with higher native T1 and extracellular volume (ECV) values compared with healthy volunteers (1096 ± 78ms vs. 994 ± 54ms and 33.9 ± 5.6% vs. 25.9 ± 3.1%, respectively, p < 0.001). Seventeen MVP patients (89.5%) had fibrosis by biopsy. BB-LGE + in LV and PM was identified in 5 (26.3%) patients, while DB-LGE + was observed in LV in 9 (47.4%) and in PM in 15 (78.9%) patients. DB-LGE + in PM was the only technique that showed no difference with detection of LV fibrosis by biopsy. Posteromedial PM was more frequently affected than the anterolateral (73.7% vs. 36.8%, p = 0.039) and correlated with biopsy-proven LV fibrosis (Rho 0.529, p = 0.029). CONCLUSIONS: CMR imaging in MVP patients referred for surgery shows a dark-appearance of the PM with higher T1 and ECV values compared with healthy volunteers. The presence of a positive DB-LGE at the posteromedial PM by CMR may serve as a better predictor of biopsy-proven LV inferobasal fibrosis than conventional CMR techniques.


Assuntos
Prolapso da Valva Mitral , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Prolapso da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/cirurgia , Músculos Papilares/patologia , Ventrículos do Coração , Meios de Contraste , Valor Preditivo dos Testes , Gadolínio , Fibrose , Imagem Cinética por Ressonância Magnética
2.
Res Sq ; 2023 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-37292932

RESUMO

Purpose: Mitral valve prolapse (MVP) is associated with left ventricle (LV) fibrosis, including the papillary muscles (PM), which is in turn linked to malignant arrhythmias. This study aims to evaluate comprehensive tissue characterization of the PM by cardiovascular magnetic resonance (CMR) imaging and its association with LV fibrosis observed by intraoperative biopsies. Methods: MVP patients with indication for surgery due to severe mitral regurgitation (n=19) underwent a preoperative CMR with characterization of the PM: dark-appearance on cine, T1 mapping, conventional bright blood (BB) and dark blood (DB) late gadolinium enhancement (LGE). CMR T1 mapping was performed on 21 healthy volunteers as controls. LV inferobasal myocardial biopsies were obtained in MVP patients and compared to CMR findings. Results: MVP patients (54±10 years old, 14 male) had a dark-appearance of the PM with higher native T1 and extracellular volume (ECV) values compared with healthy volunteers (1096±78ms vs 994±54ms and 33.9±5.6% vs 25.9±3.1%, respectively, p<0.001). Seventeen MVP patients (89.5%) had fibrosis by biopsy. BB-LGE+ in LV and PM was identified in 5 (26.3%) patients, while DB-LGE+ was observed in LV in 9 (47.4%) and in PM in 15 (78.9%) patients. DB-LGE+ in PM was the only technique that showed no difference with detection of LV fibrosis by biopsy. Posteromedial PM was more frequently affected than the anterolateral (73.7% vs 36.8%, p=0.039) and correlated with biopsy-proven LV fibrosis (Rho 0.529, p=0.029). Conclusions: CMR imaging in MVP patients referred for surgery shows a dark-appearance of the PM with higher T1 and ECV values compared with healthy volunteers. The presence of a positive DB-LGE at the posteromedial PM by CMR may serve as a better predictor of biopsy-proven LV inferobasal fibrosis than conventional CMR techniques.

3.
Artif Organs ; 46(1): 106-116, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34398476

RESUMO

The resolution of functional mitral valve regurgitation (MR) in patients awaiting left ventricular assist device (LVAD) implantation is discussed controversially. The present study analyzed MR and echocardiographic parameters of the third-generation LVAD HeartMate 3 (HM3) over 3 years. Of 135 LVAD patients (with severe MR, n = 33; with none, mild, or moderate MR, n = 102), data of transthoracic echocardiography were included preoperatively to LVAD implantation, up to 1 month postoperatively, and at 1, 2, and 3 years after LVAD implantation. Demographic data and clinical characteristics were collected. Severe MR was reduced immediately after LVAD implantation in all patients. The echocardiographic parameters left ventricular end-diastolic diameter (P < .001), right ventricular end-diastolic diameter (P < .001), tricuspid annular plane systolic excursion (P < .001), and estimated pulmonary artery pressure (P < .001) decreased after HM3 implantation independently from the grade of MR prior to implantation and remained low during the 2 years follow-up period. Following LVAD implantation, right heart failure, ventricular arrhythmias, ischemic stroke as well as pump thrombosis and bleeding events were comparable between the groups. The incidences of death and cardiac death did not differ between the patient groups. Furthermore, the Kaplan-Meier analysis showed that survival was comparable between the groups (P = .073). HM3 implantation decreases preoperative severe MR immediately after LVAD implantation. This effect is long-lasting in most patients and reinforces the LVAD implantation without MR surgery. The complication rates and survival were comparable between patients with and without severe MR.


Assuntos
Insuficiência Cardíaca/terapia , Coração Auxiliar , Insuficiência da Valva Mitral/fisiopatologia , Adulto , Ecocardiografia , Feminino , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/patologia , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/diagnóstico por imagem , Implantação de Prótese , Resultado do Tratamento , Disfunção Ventricular Esquerda/terapia
4.
J Cardiovasc Magn Reson ; 23(1): 87, 2021 07 08.
Artigo em Inglês | MEDLINE | ID: mdl-34233708

RESUMO

BACKGROUND: Four-dimensional cardiovascular magnetic resonance (CMR) flow assessment (4D flow) allows to derive volumetric quantitative parameters in mitral regurgitation (MR) using retrospective valve tracking. However, prior studies have been conducted in functional MR or in patients with congenital heart disease, thus, data regarding the usefulness of 4D flow CMR in case of a valve pathology like mitral valve prolapse (MVP) are scarce. This study aimed to evaluate the clinical utility of cine-guided valve segmentation of 4D flow CMR in assessment of MR in MVP when compared to standardized routine CMR and transthoracic echocardiography (TTE). METHODS: Six healthy subjects and 54 patients (55 ± 16 years; 47 men) with MVP were studied. TTE severity grading used a multiparametric approach resulting in mild/mild-moderate (n = 12), moderate-severe (n = 12), and severe MR (n = 30). Regurgitant volume (RVol) and regurgitant fraction (RF) were also derived using standard volumetric CMR and 4D flow CMR datasets with direct measurement of regurgitant flow (4DFdirect) and indirect calculation using the formula: mitral valve forward flow - left ventricular outflow tract stroke volume (4DFindirect). RESULTS: There was moderate to strong correlation between methods (r = 0.59-0.84, p < 0.001), but TTE proximal isovelocity surface area (PISA) method showed higher RVol as compared with CMR techniques (PISA vs. CMR, mean difference of 15.8 ml [95% CI 9.9-21.6]; PISA vs. 4DFindirect, 17.2 ml [8.4-25.9]; PISA vs. 4DFdirect, 27.9 ml [19.1-36.8]; p < 0.001). Only indirect CMR methods (CMR vs. 4DFindirect) showed moderate to substantial agreement (Lin's coefficient 0.92-0.97) without significant bias (mean bias 1.05 ± 26 ml [- 50 to 52], p = 0.757). Intra- and inter-observer reliability were good to excellent for all methods (ICC 0.87-0.99), but with numerically lower coefficient of variation for indirect CMR methods (2.5 to 12%). CONCLUSIONS: In the assessment of patients with MR and MVP, cine-guided valve segmentation 4D flow CMR is feasible and comparable to standard CMR, but with lower RVol when TTE is used as reference. 4DFindirect quantification has higher intra- and inter-technique agreement than 4DFdirect quantification and might be used as an adjunctive technique for cross-checking MR quantification in MVP.


Assuntos
Insuficiência da Valva Mitral , Prolapso da Valva Mitral , Humanos , Imagem Cinética por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Masculino , Insuficiência da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/diagnóstico por imagem , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença
5.
Int J Cardiovasc Imaging ; 37(6): 1947-1959, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33616785

RESUMO

Three-dimensional transthoracic echocardiography (3D-TTE) provides a semi-automated proximal isovelocity surface area method (3D-PISA) to obtain quantitative parameters. Data assessing regurgitation severity in mitral valve prolapse (MVP) are scarce, so we assessed the 3D-PISA method compared with 2D-PISA and cardiovascular magnetic resonance (CMR) and the role of an eccentricity index. We evaluated the 3D-PISA method for assessing MR in 54 patients with MVP (57 ± 14 years; 42 men; 12 mild/mild-moderate; 12 moderate-severe; and 30 severe MR). Role of an asymmetric (i.e. eccentricity index ≥ 1.25) flow convergence region (FCR) and inter-modality consistency were then assessed. 3D-PISA derived regurgitant volume (RVol) showed a good correlation with 2D-PISA and CMR derived parameters (r = 0.86 and r = 0.81, respectively). The small mean differences with 2D-PISA derived RVol did not reach statistical significance in overall population (5.7 ± 23 ml, 95% CI - 0.6 to 12; p = 0.08) but differed in those with asymmetric 3D-FCR (n = 21; 2D-PISA: 72 ± 36 ml vs. 3D-PISA: 93 ± 47 ml; p = 0.001). RVol mean values were higher using PISA methods (CMR 57 ± 33 ml; 2D-PISA 73 ± 39 ml; and 3D-PISA 79 ± 45 ml) and an overestimation was observed when CMR was used as reference (2D-PISA vs. CMR: mean difference: 15.8 ml [95% CI 10-22, p < 0.001]; and 3D-PISA vs. CMR: 21.5 ml [95% CI 14-29, p < 0.001]). Intra- and inter-observer reliability was excellent (ICC 0.91-0.99), but with numerically lower coefficient of variation for 3D-PISA (8%-10% vs. 2D-PISA: 12%-16%). 3D-PISA method for assessing regurgitation in MVP may enable analogous evaluation compared to standard 2D-PISA, but with overestimation in case of asymmetric FCR or when CMR is used as reference method.


Assuntos
Ecocardiografia Tridimensional , Insuficiência da Valva Mitral , Prolapso da Valva Mitral , Ecocardiografia Doppler em Cores , Humanos , Masculino , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Prolapso da Valva Mitral/diagnóstico por imagem , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
6.
Eur J Cardiothorac Surg ; 57(2): 300-307, 2020 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-31369069

RESUMO

OBJECTIVES: Mitral valve (MV) annuloplasty ring dehiscence with subsequent recurrent mitral regurgitation represents an unusual but challenging clinical problem. Incidence, localization and outcomes for this complication have not been well defined. METHODS: From 1996 to 2016, a total of 3478 patients underwent isolated MV repair with ring annuloplasty at the Leipzig Heart Centre. Of these patients, 57 (1.6%) underwent reoperation due to annuloplasty ring dehiscence. Echocardiographic data, operative and early postoperative characteristics as well as short- and long-term survival rates after MV reoperation were analysed. RESULTS: Occurrences of ring dehiscence were acute (<30 days), early (≤1 year) and late (>1 year) in 44%, 33% and 23% of patients, respectively. Localization of annuloplasty ring dehiscence was found most frequently in the P3 segment (68%), followed by the P2 (51%) and the P1 segments (47%). The 30-day mortality rate and 1- and 5-year survival rates after MV reoperation were 2%, 89% and 74%, respectively. During reoperation, MV replacement was performed in 38 (67%) and MV re-repair in 19 (33%) patients. CONCLUSIONS: Annuloplasty ring dehiscence is clinically less common, localized more frequently on the posterior annulus and occurs mostly acutely or early after MV repair. MV reoperation can be performed safely in such patients.


Assuntos
Implante de Prótese de Valva Cardíaca , Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Incidência , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Anuloplastia da Valva Mitral/efeitos adversos , Insuficiência da Valva Mitral/epidemiologia , Insuficiência da Valva Mitral/cirurgia , Reoperação , Resultado do Tratamento
7.
Eur J Cardiothorac Surg ; 56(5): 983-992, 2019 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-30932164

RESUMO

OBJECTIVES: The goal of this study was to quantify the mitral valve (MV) annulus, the MV shape and the anatomical MV orifice area throughout the cardiac cycle using 4-dimensional MV analysis software in patients with primary mitral regurgitation (PMR) and secondary mitral regurgitation (SMR) in comparison to a healthy control group. METHODS: Three-dimensional transoesophageal echocardiograms of the MV were acquired for 29 patients with PMR, for 28 patients with SMR and for 18 healthy control subjects. The MV was quantified with regards to anterior-posterior and lateromedial diameter, annular area and circumference, intertrigonal (IT) distance, annular sphericity index, annular height to commissural width ration, and anatomical MV orifice area throughout the cardiac cycle using 3-dimensional transoesophageal echocardiography-based 4-dimensional MV advanced analysis software. RESULTS: Normal annulus dynamics display a systolic enlargement followed by an early-diastolic plateau phase and a late-diastolic contraction. The IT distance showed a linear association with the anterior-posterior diameter (= 1.11 × IT distance) and lateromedial diameter (= 1.44 × IT distance) in the control subjects. Mitral regurgitation is associated with a less dynamic, planar and dilated annulus with small variations between PMR and SMR. The IT distance was less affected by mitral regurgitation compared to the control subjects. CONCLUSIONS: The novel 4-dimensional MV analysis allows new insights into the dynamic MV geometry in patients with PMR and SMR compared to the control subjects. The IT distance may be used to predict annuloplasty ring sizing.


Assuntos
Ecocardiografia Tridimensional/métodos , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Mitral , Valva Mitral , Adulto , Idoso , Idoso de 80 Anos ou mais , Diástole/fisiologia , Ecocardiografia Transesofagiana , Feminino , Próteses Valvulares Cardíacas , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/patologia , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/patologia , Insuficiência da Valva Mitral/cirurgia , Estudos Prospectivos , Software , Sístole/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA