Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Eur Radiol ; 2023 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-38041717

RESUMO

OBJECTIVES: To compare the results of CT- vs MR-guided radiofrequency ablation (RFA) of liver metastases (LM) from colorectal cancer after 10 years of follow-up in an observational, retrospective, and multicentric study. METHODS: A total of 238 patients with 496 LM were treated with RFA either with CT (CT group) or magnetic resonance (MR group) guidance. Every ablated LM was assessed and followed up with diagnostic MRI. Technical success, technique efficacy, predictive factors, recurrence rates, and overall survival were assessed. RESULTS: The CT group comprised 143 patients and the MR group 77 patients. Eighteen patients underwent ablation with both modalities. Technical success per patient and per lesion was 88% and 93% for CT and 87% and 89.6% for MR, and technique efficacy was 97.1% and 98.6% for CT and 98.7% and 99.3% for MR respectively. Local recurrence following the first ablation (primary patency) occurred in 20.1% (CT) vs 4.6% (MR) (p < 0.001). Residual liver tumor, size of LM, and advanced N and M stage at initial diagnosis were independent predictors for overall survival in both groups. The median overall survival measured from first RFA treatment was 2.6 years. The 1-year, 5-year, and 10-year survival were 85.9%, 25.5%, and 19.1% respectively. CONCLUSIONS: The MR group had significantly better local control compared to the CT group. There was no significant difference in patient survival between the two groups. CLINICAL RELEVANCE STATEMENT: MR-guided radiofrequency ablation of colorectal liver metastases is safe and effective, and offers better local control than CT-guided ablation. KEY POINTS: • Imaging modality for radiofrequency ablation guidance is an independent predictor of local recurrence in colorectal liver metastases. • MR-guided radiofrequency ablation achieved better local control of liver metastases from colorectal cancer than CT-guided. • The number and size of liver metastases are, among others, independent predictors of survival. Radiofrequency ablation with MR guidance improved clinical outcome but does not affect survival.

2.
Surg Innov ; 30(5): 628-631, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36450157

RESUMO

Background: The first modern cystoscope was developed with the invention of rod lens and optical fibers in the 1960s. Since then, many advances have been made in functionality and camera image analysis. The cost of purchasing equipment and volume of the endoscopic tower remains a challenge and a barrier to the spread of cystoscopy. Urinary tract injury is a significant complication in women undergoing gynecologic surgery. Selective intraoperative cystoscopy at laparoscopic hysterectomy or complex pelvic surgery is valuable for recognizing lower urinary tract injuries. We have developed a novel wireless cystoscope for performing diagnostic and operative cystoscopy. Methods: The new wireless cystoscopic setup consists of a rigid cystoscope 4 mm, 30° that joins a modified action camera to a c-mount adapter f 18-35 mm and a portable led light source. Results: The new setup has so far been effectively used in more than 50 diagnostic cystoscopies and pigtail catheter replacements without complications. Two cases performed with the new setup are presented in the video. Conclusions: The new cystoscopic setup has the advantage of a wireless video camera, 4K ultraHD, and is easy setup. Due to its low cost and portability, the wireless cystoscope is easy to obtain and use. Also, it is invaluable and ergonomic in managing the integrity or pathology of the bladder, urethra, and ureters.


Assuntos
Cistoscópios , Cistoscopia , Feminino , Humanos , Cistoscopia/métodos , Histerectomia/métodos , Procedimentos Cirúrgicos em Ginecologia , Processamento de Imagem Assistida por Computador
3.
Clin Case Rep ; 9(11): e05056, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34840798

RESUMO

We describe a useful technique, in laparoscopic cystectomy in-a-bag, for suspension and stabilization of endobag and adnexa using temporary sutures. It intends to create an isolated field to avoid spillage of the cyst content into the abdomen in case of rupture, thereby allowing the safe laparoscopic removal of ovarian masses.

4.
Clin Case Rep ; 9(9): e04693, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34484753

RESUMO

A simple technique that permits to reduce the cost during gynecologic laparoscopic surgery. Small specimens may be retrieved with the use of a modified urine pediatric bag.

5.
Obstet Gynecol ; 136(5): 908-911, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-33030861

RESUMO

BACKGROUND: Wireless signal transduction is the future in the field of laparoscopic surgery. Cable-free endoscopic equipment would be the ideal surgical instrument for every laparoscopic surgeon. INSTRUMENT: Our department has developed a new cable-free laparoscopic setup that couples a rigid 0°, 10-mm laparoscope with a wireless camera modified with a special adapter. We used a portable and rechargeable LED cold light source. The signal was wirelessly transmitted from the camera to a tablet computer using the corresponding mobile application. EXPERIENCE: Our team has used this setup in 14 laparoscopic operations with excellent results. Two cases performed exclusively with the new setup are presented in the videos. The image quality obtained was comparable with the conventional laparoscopic setup, and the operations performed were unaffected. CONCLUSION: This report presents the use of a wireless camera throughout the course of a laparoscopic surgery, and the results are promising. The new systems' favorable characteristics, such as wireless signal transmission, cost, flexibility, and size, support this as a feasible new technique for performing laparoscopic surgery.


Assuntos
Procedimentos Cirúrgicos em Ginecologia/instrumentação , Laparoscópios/tendências , Laparoscopia/instrumentação , Tecnologia sem Fio/tendências , Desenho de Equipamento , Feminino , Procedimentos Cirúrgicos em Ginecologia/métodos , Procedimentos Cirúrgicos em Ginecologia/tendências , Humanos , Laparoscopia/métodos , Laparoscopia/tendências
6.
Int J Surg Case Rep ; 41: 1-4, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29017137

RESUMO

INTRODUCTION: Ovarian vein thrombosis is a rare but potentially serious complication after surgical and gynecologic procedures such as oophorectomy and hysterectomy. The association of this event with laparoscopic hysterectomy in particular, is very rare. Only two cases have been described so far. PRESENTATION OF CASE: We present a case of ovarian vein thrombosis after laparoscopic hysterectomy in a 40-year-old with deep endometriosis and multiple intramural uterine myomas. Laparoscopic hysterectomy, left oophorectomy, right salpingectomy, and suspension (ovariopexy) of the right ovary on the ipsilateral round ligament of the uterus were performed, using bipolar electrocautery as a hemostatic tool. DISCUSSION: The 7th postoperative day the patient presented to our hospital complaining of abdominal pain and fever. An abdominal CT scan demonstrated a filling defect and enlargement of the right ovarian vein, a finding compatible with ovarian vein thrombosis. She was treated with low molecular weight heparin (LMWH). On the 19th postoperative day, an MRI scan was performed and did not reveal any pathological findings of the right ovarian vein. The patient was discharged on LMWH for three months. Post treatment evaluation for thrombophilia was negative for pathological findings. CONCLUSION: Our case is a very rare condition. Only two 'similar' cases have been described in the literature so far. Bipolar electrocautery and ovariopexy on the ipsilateral round ligament during laparoscopic hysterectomy should be evaluated further as possible contributing mechanisms for the thrombus formation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA