Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
1.
Braz. oral res. (Online) ; 38: e024, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1557358

RESUMO

Abstract This study aimed to identify and characterize the antimicrobial susceptibility profile of bacteria found in primary endodontic infections in the teeth of patients treated at the Dental Clinic of the University of Ribeirão Preto, São Paulo, Brazil. From September to December 2019, samples were obtained from 21 patients with primary endodontic infections. The collections were carried out in triplicate using paper cones placed close to the total length of the root canal. Bacterial isolation was performed in Brain Heart Infusion agar, Blood agar, and other selective culture media cultured at 37°C for up to 48 h under aerobiosis and microaerophilic conditions. The bacterial species were identified using the Vitek 2 automated system. The disk diffusion method on agar Müeller-Hinton was used to assess antimicrobial susceptibility with the recommended antimicrobials for each identified bacterial species. A total of 49 antibiotics were evaluated. Fifteen of the 21 samples collected showed bacterial growth, and 17 bacterial isolates were found. There were 10 different bacterial species identified: Enterococcus faecalis (four isolates), Streptococcus mitis/oralis (three isolates), Streptococcus anginosus (three isolates) being the most common, followed by Staphylococcus epidermidis, Enterococcus faecium, Streptococcus constellatus, Streptococcus alactolyticus, Enterobacter cloacae, Klebsiella variicola, and Providencia rettgeri (one isolate of each species). The analysis demonstrated significant susceptibility to most of the tested antibiotics. However, some Enterococcus isolates resisted the antibiotic's erythromycin, ciprofloxacin, and tetracycline. A Staphylococcus epidermidis isolate was characterized as multidrug-resistant. Five Streptococcus isolates were non-susceptible to all antibiotics tested.

2.
J Photochem Photobiol B ; 238: 112612, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36459910

RESUMO

Photobiomodulation therapy (PTB) is a therapeutic possibility for temporomandibular disorders (TMD), but its effectiveness and protocols for use remain controversial. This study is a RCT that compared the effectiveness of PTB on pain points of the masticatory muscles and TMJs, located through palpation versus application of pre-established points in women with painful TMD, diagnosis by DC/TMD (Diagnostic Criteria for Temporomandibular Disorders - Brazilian Portuguese version). Therefore, a total sample of 54 women, aged between 18 and 60 years, was investigated. Volunteers were randomly randomized and PTB was applied in four different groups with a dose of 4 J and 6 J divided into pre-established application points (PE - G1) and pain points (PD - G2) - Groups 4PE, 4PD, 6PE and 6PD. Four laser applications were performed with a wavelength of 780 nm, one session per week, totaling one month of therapy. The following assessments were performed: DC/TMD, Brief Pain Inventory (BPI), McGill Questionnaire - Short Version (SF-MPQ) and Pain Intensity, Visual Analogue Scale (VAS). Friedman's test was used for within-group comparisons, while the Mann-Whitney test was used for between-group comparisons (p < 0.05). According to the results, laser application on pain points (G2) was more effective. McGill's results showed that regardless of dose, the pain point application group had better outcomes (p = 0.004). Pain intensity evaluation (last days) also showed that application at the pain points was more effective regardless of dose (p = 0.0002). Medians and interquartile deviations showed overall that PTB was more effective at pain points, with a trend towards better outcomes at the 6 J dose. Therefore, it can be concluded that in women with chronic painful TMD, the application of PTB at pain points is more effective than the application at pre-established points. Therefore, individualized PTB protocols are proposed, based on examination palpation of the masticatory structures.


Assuntos
Dor Crônica , Terapia com Luz de Baixa Intensidade , Transtornos da Articulação Temporomandibular , Humanos , Feminino , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Dor Crônica/radioterapia , Transtornos da Articulação Temporomandibular/radioterapia , Terapia com Luz de Baixa Intensidade/métodos , Medição da Dor , Músculos da Mastigação
3.
Braz. oral res. (Online) ; 37: e096, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1520524

RESUMO

Abstract The survival of endodontically treated teeth depends on the remaining tooth structure. The aim of this study was to evaluate the impact of different access cavities on root canal preparation, restorative protocol, and fracture resistance of endodontically treated teeth. Fifty-six mandibular molars were divided into control (n=8) and experimental (n=16) groups according to access cavity: Traditional, Conservative, and Truss; and redistributed (n=8) according to instrumentation protocols: Reciproc Blue and R-motion. After, teeth were scanned in micro-CT and then filled and redistributed according to composite resin restoration (n=8): Filtek One BulkFill and Filtek Z350. A new micro-CT scan was performed to analyze the restorative material. Then, samples were submitted to fracture resistance testing and the failure pattern was determined. Data were analyzed using paired T-test, ANOVA, Tukey, and chi-square tests (α=0.05). In Truss, R-Motion promoted less transportation in different thirds of root canals. Higher percentages of voids (5.05%) and filling material (11.7%) were observed in Truss. Fracture resistance values were higher for the control group, followed by Truss, Conservative, and Traditional. The predominant failure pattern was type-II. In Truss, reciprocating instruments with smaller taper showed less canal transportation. Also, Truss provided higher values of fracture resistance, although it presented a higher percentage of voids and remaining filling material. Thus, in Truss, reciprocating files with smaller taper showed less canal transportation, and these cavities provided higher values of fracture resistance, although it presented a higher percentage of voids and remaining filling material.

4.
J Mech Behav Biomed Mater ; 135: 105486, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36182677

RESUMO

Chemical composition of temporary cements interferes in the bond strength and quality of the bond interface of glass fiber posts to root dentin. The aim of the present study was to evaluate the influence of different temporary cements on the bond strength of fiberglass posts and resin cement. Thirty-two maxillary central incisor roots were standardized at 15 mm length. The root canals were prepared with Reciproc R50 and filled with a R50 single cone and AH Plus. Ten mm of filling material was removed with a heated Schilder condenser, leaving 5 mm of apical filling material. The roots were randomly distributed into 4 groups (n = 8). In the control group, the root canal was prepared with a standard drill according to the post diameter (DC #1, FGM, Joinville, Brazil), irrigated with 5 mL of distilled water and immediately received the fiberglass post cemented with self-adhesive resin cement. For the other groups, cores were made with temporary intraradicular retainers cemented with different temporary cements: methacrylate-based resin (Bifix Temp - Voco), calcium hydroxide-based (Provicol - Voco) and zinc oxide-based - eugenol-free (Relyx Temp NE - 3M). After 7 days, mechanical removal of the temporary retainers, preparation, irrigation of the root canal and cementation of the fiberglass post were performed, following the same protocol that had been performed in the control group. The roots were sectioned to obtain 3 slices per root third. The most cervical section of each third was used for the push-out test and failure pattern analysis, while the most apical section was subjected to analysis of the adhesive interface by scanning electron microscopy (SEM). The BS data were compared between groups using the two-way ANOVA and Tukey post-test. The failure pattern results were expressed in percentage and compared between groups using the chi-square test and the material adaptation data at the bond interface were evaluated using the Kruskal-Wallis and Dwass-Steel-Critchlow-Fligner tests. The results showed higher BS in the cervical third, with a higher value in the control group (10.8 ± 0.94) and Bifix Temp group (9.78 ± 0.71), with no statistically significant difference between these groups (P > .05). The middle and apical thirds showed no statistically significant difference (P > .05). As regards the type of failure, a higher percentage of mixed adhesive failures was observed for all groups. Analysis of the adhesive interface by SEM showed that the temporary cement Bifix Temp showed greater adaptation at the bond interface. It was concluded that the methacrylate-based resin temporary cement showed the highest bond strength values and best adaptation to root dentin than the zinc oxide-based and calcium hydroxide-based temporary cements.


Assuntos
Colagem Dentária , Técnica para Retentor Intrarradicular , Óxido de Zinco , Hidróxido de Cálcio , Cimentação/métodos , Análise do Estresse Dentário , Dentina , Vidro/química , Hidroxibenzoatos , Teste de Materiais , Metacrilatos , Nitrofuranos , Cimentos de Resina/química , Aço , Água
5.
Int Endod J ; 55(1): 124-136, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34687053

RESUMO

AIM: To evaluate the shaping ability of several heat-treated nickel-titanium systems used to prepare root canals with moderate and severe curvature, in extracted mandibular molars, by micro-computed tomography, considering their variation in kinematics and design. METHODOLOGY: Curved-mesial roots of mandibular molars were randomly selected and assigned into 4 balanced experimental groups (n = 10), established by determining homogeneous 3D parameters of volume and surface area: R-Motion (RM) size 30, 0.04 taper (RM; FKG Dentaire), Reciproc Blue (RCB) size 25, 0.08 taper (RCB; VDW GmbH), HyFlex CM (HFX) size 30, 0.04 taper (HFX; Coltène Whaledent) and XP-endo Shaper size (XPS) 30, 0.01 taper (XPS; FKG Dentaire). The volume of irrigation was established at 10 ml of 2.5% NaOCl. Throughout the entire root canal preparation procedures, the samples were fixed in a vice submerged in a container with water monitored at 37°C. Dimensional cross-sectional measures of area, perimeter, roundness, major/minor diameters and 3-dimensional (volume, surface area, structure model index - SMI) parameters as well as the smallest dentine thickness along the cervical and middle root thirds were evaluated by micro-CT. Data were analysed using analysis of variance and post hoc Tukey tests (α = 5%). RESULTS: Reciproc Blue and XPS had significantly greater mean increases in cross-sectional area measurements, only in the middle third, when compared with RM and HFX (p < .05). RM, RCB and XPS had a similar increase in measurements of length and width of perimeter (p > .05), and HFX had significantly lower mean increases in perimeter values only when compared with XPS (p < .05). RCB and XPS had significantly greater mean increases in volume when compared with RM and HFX (p < .05). RM had a significantly lower difference in SMI after preparation, compared with RCB, HFX and XPS (p < .05). The smallest dentine thickness was observed after the use of RCB (p < .05), in the danger and safety zones. CONCLUSIONS: XP-endo Shaper and RM had a shaping ability similar to that of instruments with larger tapers, achieved with less dentine removal in danger and safe zones in curved-mesial canals of extracted molar teeth treated on a laboratory benchtop.


Assuntos
Cavidade Pulpar , Preparo de Canal Radicular , Cavidade Pulpar/diagnóstico por imagem , Desenho de Equipamento , Dente Molar/diagnóstico por imagem , Dente Molar/cirurgia , Níquel , Titânio , Microtomografia por Raio-X
6.
Braz. dent. j ; 32(5): 12-22, Sept.-Oct. 2021. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1350296

RESUMO

Abstract The aim of this study was to evaluate the influence of different instruments and mechanisms of agitation of the irrigating solution on the penetration by confocal laser scanning microscopy (CLSM), and the bond strength (BS) of the filling material to the dentin by push-out test. Human premolars were distributed in two experimental groups (n=30), according to the instrumentation system: ProTaper Next (PN) or XP-endo Shaper (XS) and three irrigation protocol (n=10): NaviTip (Nv), XP-endo Finisher (XF), passive ultrasonic irrigation/ XP-endo Finisher (PUIXF). The 2.5% NaOCl and 17% EDTA were the irrigating solutions used. The filling was performed using a lateral condensation technique, with AH Plus added to 0.1% rodhamine B. The roots were sectioned, obtaining 2 slices for each third of the root. The first slice was submitted to the sealer penetration analysis and the push-out test. The second slice was submitted to qualitative analysis (SEM) of the union interface. For the penetration (%) Tukey showed that PNXF (82.38±13.48), PNPUIXF (82.48± 12.02), XSXF (82.24±11.28) and XSPUIXP (86.23±10.45) presented the highest values, different (p<0.05) from PNNv (68.29±15.12) and XSNv (71.41±16.50). The BS (MPa) test evidenced that in the cervical third, PNPF (4.92±1.04) and XPSPF (5.03±0.70) obtained the highest values differing from the others groups (p<0.05). CSLM and SEM showed greater penetration of the sealer on the entire length of the root canal when the irrigation solution was stirred. In conclusion that the association PUI and XP-endo Finisher favored the penetration and bond strength of the filling material to the root dentin.


Resumo O objetivo neste estudo foi avaliar a influência de diferentes instrumentos e mecanismos de agitação da solução irrigadora na penetração e resistência de união (RU) do AH Plus à dentina. Pré molares humanos foram distribuídos em dois grupos experimentais (n=30), de acordo com o sistema de instrumentação: ProTaper Next (PN) ou XP-endo Shaper (XS) e de acordo com três protocolos de irrigação (n=10): NaviTip (Nv), XP-endo Finisher (XF), passive ultrasonic irrigation/ XP-endo Finisher (PUIXF). A irrigação do canal radicular foi realizada com NaOCl 2,5% e EDTA 17%. A obturação foi realizada por meio da técnica da condensação lateral, com AH Plus acrescido de rodhamina B 0,1%. As raízes foram seccionadas, obtendo-se 2 slices de 2,0 mm para cada terço radicular. O primeiro slice foi submetido a análise da penetração do cimento e ao teste de push-out e o segundo slice submetido a MEV para análise da interface de união. Para penetração (%) Tukey evidenciou que PNXF (82,38±13,48), PNPUIXF (82,48±12,02), XSXF (82,24±11,28) e XSPUIXF (86,23±10,45) apresentaram os maiores valores, diferentes (p<0,05) de PNC (68,29±15,12) e XPSC (71,41±16,50). Na RU (MPa) foi evidenciado que PNPF (4,92±1,04) e XPSPF (5,03±0,70), no terço cervical, obtiveram os maiores valores diferentes dos demais (p<0,05). MCVL e MEV evidenciaram maior penetração do cimento em toda extensão da parede do canal radicular inclusive nas regiões polares, quando foi realizada a agitação da solução irrigadora. Concluiu-se que a associação PUI e XP-endo Finisher favoreceu a penetração e resistência de união do material obturador à dentina radicular.

7.
Braz. oral res. (Online) ; 35: e117, 2021. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1350360

RESUMO

Abstract This study evaluated by the efficacy of rotary and reciprocating systems to remove filling material by micro-CT. Sixty human canines were instrumented up to F3 by ProTaper Universal system and filled with AH Plus/ gutta-percha. Specimens were submitted to 1,200 thermal cycles, scanned by microCT SkyScan 1176 and randomly distributed in groups according to the filling material removal protocol (n = 10): ProTaper Universal, ProTaper Universal/xylol, ProTaper Next, ProTaper Next/xylol, Reciproc and Reciproc/xylol. After filling removal, specimens were analyzed by microCT to separately verify the presence of gutta-percha and sealer remnants. The data (mm3) were analyzed by two way ANOVA and Tukey´s test (5%). For the remaining gutta-percha, the use of xylol provided the highest values for Reciproc (7.60 ± 0.73), which was statistically different from the other groups (p < 0.05) that presented lower values and were statistically similar to each other (p > 0.05). For the remaining sealer, xylol provided the highest values (21.25 ± 6.94) different (p < 0.05) from the use of instruments alone (11.47 ± 9.45). ProTaper Next presented the lowest values (8.16 ± 1.37) for the remaining sealer, different (p < 0.05) from that of Reciproc (24.67 ± 6.32). The qualitative analysis revealed that all groups presented some remaining root filling material, with the highest volumes presented by Reciproc and Reciproc/xylol. In conclusion the rotary systems provided greater removal of filling material regardless of the use of xylol. The use of xylol negatively interfered with the action of the reciprocating system in the removal of the gutta-percha and sealer.

8.
Braz. dent. j ; 31(5): 485-492, Sept.-Oct. 2020. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1132341

RESUMO

Abstract Green chemistry has been applied in different areas due to the growing demands for renewable processes and one of them is nanotechnology. The aim of this study was to characterize a formulation containing silver nanoparticles (AgNPs) produced by a green synthesis and to evaluate its antimicrobial activity. The formulation will be used as an intracanal dressing exploiting the AgNPs' antimicrobial properties, which are crucial to prevent infections and bacterial reinfections that can compromise endodontic treatments. In the green synthesis, silver nitrate was employed as the precursor salt, maltose as a reducing agent, and gelatin as a stabilizing agent. The formulation was prepared mixing 50 % of a liquid containing the AgNPs and 50 % of hydroxyethylcellulose gel at 1.5 % with proper evaluation of the process inherent parameters. Techniques such as molecular absorption spectrometry and dynamic light scattering were used in characterization step. The antimicrobial activity of the AgNPs against Escherichia coli ATCC 25922, Enterococcus faecalis NCTC 775, Pseudomonas aeruginosa ATCC 27853, Staphylococcus aureus ATCC 25923 and Streptococcus mutans ATCC 25175 was verified according to National Comittee for Clinical Laboratory Standards (NCCLS) by determining minimal inhibitory concentration (MIC) and minimal bactericidal concentration (MBC). The obtained results indicated the formulation containing AgNPs produced by a green synthesis was properly characterized by the selected techniques. Furthermore, the formulation assessment proved that it is suitable for the proposal as well as it has potential to be used as an intracanal dressing since presented antimicrobial activity against all bacterial strains evaluated.


Resumo A química verde tem sido aplicada em diferentes áreas devido à crescente demanda por processos renováveis e uma delas é a nanotecnologia. O objetivo deste estudo foi caracterizar uma formulação contendo nanopartículas de prata (AgNPs) produzidas por meio de síntese verde e avaliar sua atividade antimicrobiana. A formulação será usada como curativo intracanal explorando as propriedades antimicrobianas das AgNPs que são cruciais para prevenir infecções e reinfecções bacterianas que podem comprometer os tratamentos endodônticos. Na síntese verde, nitrato de prata foi empregado como sal precursor, maltose como agente redutor e gelatina como agente estabilizador. A formulação foi preparada misturando-se 50% do líquido contendo as AgNPs e 50% de gel de hidroxietilcelulose a 1,5% com avaliação adequada dos parâmetros inerentes ao processo. Técnicas como espectrometria de absorção molecular e espalhamento dinâmico de luz foram usadas na etapa de caracterização. A atividade antimicrobiana das AgNPs contra Escherichia coli ATCC 25922, Enterococcus faecalis NCTC 775, Pseudomonas aeruginosa ATCC 27853, Staphylococcus aureus ATCC 25923 e Streptococcus mutans ATCC 25175 foi verificada de acordo com o National Comittee for Clinical Laboratory Standards (NCCLS), determinando-se a concentração inibitória mínima (MIC) e a concentração bactericida mínima (MBC). Os resultados obtidos indicaram que a formulação contendo AgNPs produzidas por meio de síntese verde foi devidamente caracterizada pelas técnicas selecionadas. Além disso, a avaliação da formulação provou que ela é adequada para a proposta, bem como tem potencial para ser utilizada como curativo intracanal já que apresentou atividade antimicrobiana contra todas as cepas bacterianas avaliadas.


Assuntos
Nanopartículas Metálicas , Anti-Infecciosos/farmacologia , Prata/farmacologia , Bandagens , Testes de Sensibilidade Microbiana , Antibacterianos/farmacologia
9.
Braz. dent. j ; 31(4): 374-379, July-Aug. 2020. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1132322

RESUMO

Abstract The aim of this study was to verify the effect of the implant volume loss, vertical misfit between abutment and prosthetic platform, prosthetic screw loosening torque, and screw stress distribution in titanium and zirconia abutments. Ten CAD/CAM system custom abutments of each material were milled and attached to the titanium implants. The implant volume loss was evaluated by microtomography, the vertical misfit with optical microscopy, and digital torque wrench measured the prosthetic screw loosening. All experimental analyses were performed before and after mechanical cycle (1,000,000 cycles, 100 N/2 Hz). Virtual models of the structures were created for finite element analysis, and the stress on the screw obtained with von Mises procedure. Data were analyzed using an independent t-test, two-way ANOVA for repeated measures, and Tukey's HSD test (a=0.05). There was no significant difference in the implant volume loss for the two abutment materials (p=0.662). Titanium abutments provided higher loosening torque values after mechanical cycling (p<0.001). Lesser marginal misfit was obtained with titanium abutments before and after mechanical cycling (p<0.001). The stress distribution on the screw was similar between abutment materials. In conclusion, CAD/CAM custom titanium abutment reduced the marginal misfit and increased the torque maintenance of prosthetic screws when compared to CAD/CAM custom zirconia abutment.


Resumo O objetivo neste estudo foi verificar o efeito da diminuição de volume do implante, desajuste vertical entre o pilar e plataforma protética, torque de afrouxamento do parafuso protético e distribuição da tensão no parafuso em pilares de titânio e zircônia. Dez pilares personalizados de cada material foram fresados e conectados aos implantes de titânio. A diminuição de volume do implante foi avaliada com microtomografia, o desajuste vertical com microscopia óptica e o torque de afrouxamento do parafuso protético com chave de torque digital. Todas as análises experimentais foram realizadas antes e após aplicação do ciclo mecânico (1.000.000 ciclos, 100 N/2 Hz). Modelos virtuais das estruturas foram criados para análise por elementos finitos e a tensão no parafuso obtida com valores de von Mises. Os dados foram analisados usando teste t independente, análise de varância dois fatores para medidas repetidas e teste de Tukey HSD (a=0,05). Não houve diferença significativa na diminuição de volume do implante para os dois materiais do pilar (p= 0,662). Os pilares de titânio proporcionaram maiores valores de torque de afrouxamento após o ciclo mecânico (p<0,001). O menor desajuste marginal foi obtido com os pilares de titânio antes e após o ciclo mecânico (p<0,001). A distribuição da tensão no parafuso foi similar entre os materiais. Em conclusão, os pilares personalizados de titânio reduziram o desajuste marginal e aumentaram a manutenção do torque dos parafusos protéticos quando comparados aos pilares de zircônia.


Assuntos
Titânio , Dente Suporte , Zircônio , Parafusos Ósseos
10.
Braz. oral res. (Online) ; 34: e039, 2020. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1100935

RESUMO

Abstract To compare the shaping ability of different single-file systems in the preparation of mesial curved canals of mandibular molars using micro-CT technology. Fifteen mesial roots of mandibular molars with two independent and curved canals (n = 30) were selected, scanned at a resolution of 26.7 μm anatomically matched, and distributed into three groups (n = 10), according to the preparation system: WaveOne 25.08, Reciproc 25.08, and OneShape 25.06. A final micro-CT scanning was performed, data sets were registered with their respective counterparts, and compared regarding the three-dimensional (volume, surface area, and structure model index - SMI) and two-dimensional (perimeter, area, roundness, major and minor diameters) parameters, as well as, canal transportation, using ANOVA and post hoc Tukey tests (α = 5%). Overall, no difference was observed between groups regarding area, perimeter, volume, surface area, and canal transportation (p > 0.05). Within group, no canal transportation was significantly higherobserved in the apical third (0.10 ± 0.05 mm) compared to coronal (0.08±0.040 mm) and middle (0.07 ± 0.03 mm) thirds (p < 0.05). Structure model index (SMI) was statistically higher after preparation with OneShape instrument (0.36 ± 0.26) compared to other systems (p < 0.05). Within the parameters of this study, similar shaping ability was observed in the preparation of mesial curved root canals of mandibular molars with Reciproc, OneShape and WaveOne systems.


Assuntos
Humanos , Preparo de Canal Radicular/instrumentação , Cavidade Pulpar/anatomia & histologia , Cavidade Pulpar/diagnóstico por imagem , Valores de Referência , Teste de Materiais , Análise de Variância , Estatísticas não Paramétricas , Instrumentos Odontológicos , Desenho de Equipamento , Microtomografia por Raio-X/métodos , Dente Molar/anatomia & histologia
11.
J Endod ; 45(6): 768-773, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30954280

RESUMO

INTRODUCTION: The aim of this study was to compare the shaping ability of 4 different nickel-titanium systems, considering their variation in alloy treatment, kinematics, and design, used to prepare canals with severe curvature using micro-computed tomographic analysis. METHODS: Thirty-two mesial roots of mandibular molars with severe curvature were matched based on similar morphologic dimensions and assigned to 4 experimental groups (n = 8) according to the canal preparation: ProTaper Next (PTN; Dentsply Maillefer, Ballaigues, Switzerland), Reciproc (RC; VDW GmbH, Munich, Germany), Reciproc Blue (RCB, VDW GmbH), and TRUShape (TRU; Dentsply Tulsa Dental Specialties, Tulsa, OK) systems. Changes in 2-dimensional (area and perimeter) and 3-dimensional (volume, surface area, and structure model index) morphologic parameters as well as canal transportation were compared among groups using the analysis of variance post hoc Tukey tests with the significance level set at 5%. RESULTS: Preparation significantly increased all analyzed parameters. No statistically significant differences (P > .05) were observed between RC and RCB or between PTN and TRS in any of the analyzed parameters. In the cervical third, RC and RCB presented higher mean increases than PTN and TRU. In the apical third, there were no statistically significant differences (P > .05) among the systems. CONCLUSIONS: The instruments of greater taper may promote greater morphologic changes. However, regardless of the number of instruments (multiple or single), the type of movement (rotation or reciprocating), the type of heat treatment of alloys, and the particular characteristics of each instrument (taper and design), the evaluated systems did not result in different dimensional changes and canal transportation in the critical apical area.


Assuntos
Cavidade Pulpar , Níquel , Preparo de Canal Radicular , Titânio , Ligas , Ligas Dentárias , Desenho de Equipamento , Temperatura Alta , Microtomografia por Raio-X
12.
J. appl. oral sci ; 27: e20180556, 2019. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1019971

RESUMO

Abstract Objective: To evaluate the effect of ultrasonic and sonic activation on physicochemical properties of AH Plus, MTA Fillapex, ADSeal, GuttaFlow Bioseal, and GuttaFlow 2 sealers. Methodology: Three experimental groups were formed: no activation (NA), ultrasonic activation (UA), and sonic activation (SA). The sealers were manipulated according to the manufacturers' instructions. A 3-mL syringe was adapted to receive 1 mL of sealer. Activation was performed with a 20/.01 ultrasonic insert (20 s/1W) in the UA group. A size 35.04 sonic tip was used (20 s/10,000 cycles/min-1) in the SA group. The molds for physicochemical analysis were filled and evaluated according to ANSI/ADA specification no. 57: setting time (ST), flow (FL), dimensional change (DC), solubility (SB), and radiopacity (RD). Statistical analysis was performed by Kruskal-Wallis, one-way ANOVA, and Tukey's tests (P<0.05). Results: Regarding ST, only AH Plus and GuttaFlow 2 in the NA group met the ANSI/ADA standards. All FL values were greater than 20 mm in diameter, as determined by ANSI/ADA. The tested sealers and protocols did not comply with the ANSI/ADA standards for DC. As for SB, only MTA Fillapex, regardless of the activation protocol, did not follow the ANSI/ADA standards. All of the investigated sealers, regardless of the activation protocol, presented radiographic density higher than 3 mm Al, as proposed by ANSI/ADA. Conclusions: UA and SA promoted changes in the physicochemical properties of the evaluated root canal sealers, mainly in ST and F. Thus, it is important to evaluate the physicochemical properties of endodontic sealers associated with activation techniques prior to clinical application in order to determine whether the properties follow the parameters set by ANSI/ADA, ensuring safety and quality of root canal filling.


Assuntos
Óxidos/química , Materiais Restauradores do Canal Radicular/química , Silicatos/química , Compostos de Cálcio/química , Compostos de Alumínio/química , Dimetilpolisiloxanos/química , Resinas Epóxi/química , Ondas Ultrassônicas , Guta-Percha/química , Valores de Referência , Solubilidade , Propriedades de Superfície , Fatores de Tempo , Teste de Materiais , Reprodutibilidade dos Testes , Análise de Variância , Estatísticas não Paramétricas , Combinação de Medicamentos
13.
Braz. oral res. (Online) ; 32: e18, 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-889488

RESUMO

Abstract: The aim of this study was to evaluate the bond strength of different triccalcium silicate cements to retrograde cavity using a push out test. Thirty maxillary central incisors were shaped using #80 hand files and sectioned transversally. Root slices were obtained from the apical 4 mm after eliminating the apical extremity. The specimens were embedded in acrylic resin and positioned at 45° to the horizontal plane for preparation of root-end cavities with a diamond ultrasonic retrotip. The samples were divided into three groups according to the root-end filling material (n = 10): MTA Angelus, ProRoot MTA and Biodentine. A gutta-percha cone (#80) was tugged-back at the limit between the canal and the root-end cavity. The root-end cavity was filled and the gutta-percha cone was removed after complete setting of the materials. The specimens were placed in an Instron machine with the root-end filling turned downwards. The push-out shaft was inserted in the space previously occupied by the gutta-percha cone and push out testing was performed at a crosshead speed of 1.0 mm/min. There was no statistically significant difference in resistance to push out by the materials tested (p > 0.01). MTA Angelus and ProRoot MTA showed predominantly mixed failure while Biodentine exhibited mixed and cohesive failures. The tricalcium silicate-based root-end filling materials showed similar bond strength retrograde cavity.


Assuntos
Humanos , Bismuto/química , Compostos de Cálcio/química , Colagem Dentária/métodos , Cavidade Pulpar/efeitos dos fármacos , Dentina/efeitos dos fármacos , Óxidos/química , Materiais Restauradores do Canal Radicular/química , Silicatos/química , Análise de Variância , Falha de Restauração Dentária , Guta-Percha/química , Teste de Materiais , Reprodutibilidade dos Testes , Propriedades de Superfície/efeitos dos fármacos , Raiz Dentária/efeitos dos fármacos
14.
Braz. oral res. (Online) ; 32: e44, 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-889491

RESUMO

Abstract The aim of this study was to evaluate the effects of proanthocyanidin (PA) and chlorhexidine (CHX) on the bond strength (BS), failure pattern, and resin-dentin interface morphology of the endodontic sealers EndoREZ and AH Plus after 24 h and 6 months of water storage. A total of 120 prepared bovine roots were divided into six groups: AH Plus, CHX+AH Plus, PA+AH Plus, EndoREZ, CHX+EndoREZ, and PA+EndoREZ. Dentin was treated for 1 or 5 min with 2% CHX or 15% PA, respectively. Roots were filled and stored in water for 24 h or 6 months (n = 10). Root slices were subjected to push-out test and scanning electron microscopy (SEM). Data were compared using two-way ANOVA and student's t-test (α = 5%). BS decreased over time for AH Plus and untreated EndoREZ (p < 0.05). At 24 h, AH Plus had higher BS than EndoREZ (p < 0.001), with no differences among treatments for both sealers (p > 0.05). At 6 months, EndoREZ had higher BS values for CHX and PA than control (p < 0.05). AH Plus had higher BS than EndoREZ (p < 0.001), while with CHX or PA, similar BS was observed in both sealers (p > 0.05). Cohesive and mixed failures were observed in all groups. SEM revealed sealer tags in the root dentin. In conclusion, BS decreased with time and AH Plus had higher BS than EndoREZ in untreated dentin; however, CHX or PA enhanced long-term BS of EndoREZ. Overall, dentin treatment affected failure pattern and resin-dentin interface morphology, particularly for EndoREZ.


Assuntos
Animais , Bovinos , Clorexidina/farmacologia , Colagem Dentária/métodos , Proantocianidinas/farmacologia , Resinas Sintéticas/química , Materiais Restauradores do Canal Radicular/química , Análise do Estresse Dentário , Microscopia Eletrônica de Varredura , Resistência à Tração
15.
Braz. dent. j ; 28(6): 715-719, Nov.-Dec. 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-888707

RESUMO

Abstract This study evaluated the stress distribution in endodontically treated teeth, weakened (W) or not weakened (NW), restored with different materials of prosthetic crown using 3D-FEA. Models of a maxillary canine were constructed based on micro-CT images and divided into the groups: G1 (control) - sound tooth; G2 to G7 - endodontically treated teeth restored with glass fiber post (GFP); which G2 to G4 simulated NW root and G5 to G7 simulated W root. For crown material the teeth were restored with: G2 and G5: metallic coping and ceramic veneering, G3 and G6: zirconia coping and ceramic veneering, G4 and G7: alumina coping and ceramic veneering. Load of 180 N was applied at the incisal third of lingual surface at 45º. Models were supported by the periodontal ligament (x=y=z=0). The von Mises stress (VMS) values were calculated. The W teeth presented higher VMS at coping when compared to NW teeth and group G1 showed lower VMS value. For crown material, for both W or NW teeth, increasing VMS was found at metallic, zirconia and alumina coping, respectively. Metallic coping showed a better performance despite its unfavorable esthetics, suggesting as an appropriate material for prosthetic restoration of endodontically treated teeth.


Resumo Este estudo avaliou a distribuição de tensão em dentes tratados endodonticamente, fragilizados (F) ou não fragilizados (NF), restaurados com diferentes materiais para a coroa protética utilizando 3D-FEA. Modelos de um canino maxilar foram construídos baseados em imagens de micro-CT e divididos em grupos: G1 (controle) - dente hígido; G2 a G7 - dentes tratados endodonticamente com pino de fibra de vidro (PFV), sendo que G2 a G4 simularam raízes NF e G5 a G7 simularam raízes F. Para o material das coroas os dentes foram restaurados com: G2 e G5: coping metálico e revestimento cerâmico, G3 e G6: coping de zirconia e revestimento cerâmico, G4 e G7: coping de alumina e revestimento cerâmico. Carregamento de 180 N foi aplicado na superfície lingual em seu terço incisal com 45 graus de inclinação. Os modelos foram suportados pelo ligamento periodontal (x=y=z=0). Os valores da tensão de von Mises (VMS) foram calculados. Os dentes F apresentaram maiores valores VMS para o coping quando comparados aos dentes NF, sendo que o G1 apresentou menores valores VMS. Para o material das coroas, ambos F ou NF aumentaram VMS no coping metálico, zirconia e alumina, respectivamente. Copings metálicos apresentaram melhor comportamento mecânico apesar de não favorecerem a estética, o que sugere ser um material apropriado para a restauração de dentes tratados endodonticamente.


Assuntos
Humanos , Coroas , Análise do Estresse Dentário , Dente não Vital/fisiopatologia , Análise de Elementos Finitos , Dente não Vital/terapia
16.
Braz. dent. j ; 28(2): 165-171, mar.-Apr. 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-839141

RESUMO

Abstract The aim of the present study was to evaluate the cytotoxicity of root canal sealers under conditions closely resembling a clinical reality. A primary human fibroblast cell line was seeded in 24-well acrylic plates with Dulbecco’s modified Eagle’s medium supplemented with 10% serum fetal bovine (SFB) and incubated for 24 h. Root canals from premolars were filled and individually attached to nylon devices to be stabilized in the wells with the already seeded cells. Specimens were divided into groups as follows: Control: gutta-percha cones (GPC); AH Plus+GPC; Sealapex+GPC; MTA Fillapex+GPC and Endofill+GPC. After 24 and 48 h, cell viability and morphology were evaluated by MTT assay and scanning electron microscopy (SEM), respectively. Statistical analysis was performed by Mann-Whitney test, complemented by Kruskal Wallis test (p<0.05). Only Endofill presented cytotoxicity after 24 h. MTA Fillapex and Endofill reduced the production of succinic desidrogenase after 48 h. AH Plus was non-toxic at any time point. SEM showed that the AH Plus and MTA Fillapex groups presented fibroblasts with morphology close to the control group, while the Endofill group presented few cells with thin extensions cells. The present study showed that good results were present in AH Plus and Sealapex, but not the Endofill group after 48 h. The method used enabled evaluation of the cytotoxicity of the studied sealers that diffused through the root apex.


Resumo O objetivo do presente estudo foi avaliar a citotoxicidade dos cimentos dos canais radiculares em condições próximas à realidade clinica. Uma linhagem primária de fibrolastos humanos foi semeada em placas acrílicas de 24-poços com meio de cultura Dulbecco’s modified Eagle’s medium suplementado com 10% de soro fetal bovino e incubados por 24 h. Os canais radiculares de pré-molares foram obturados e individualmente adaptados aos dispositivos de nylon para serem estabilizados nos poços com as células já semeadas. Amostras foram dividas de acordo com os grupos: Controle: cones de gutta-percha (CGP); AH Plus+CGP; Sealapex+CGP; MTA Fillapex+CGP e Endofill+CGP. Após 24 e 48 h, a viabilidade e a morfologia celular foram avaliadas pelo ensaio de MTT e microscopia eletrônica de varredura (MEV), respectivamente. Análises estatísticas foram realizadas pelo teste de Mann-Whitney, complementadas por Kruskal Wallis (p<0,05). Apenas o Endofill apresentou citotoxicidade após 24 h. MTA Fillapex e Endofill reduziram a produção da enzima desidrogenase succinica após 48 h. AH Plus não apresentou toxicidade em nenhum momento. MEV mostrou que os grupos AH Plus e o MTA Fillapex apresentaram fibroblastos com morfologia próxima ao grupo controle, enquanto que o grupo do Endofill apresentou poucas células com finos prolongamentos. O presente estudo demonstrou que resultados satisfatórios foram apresentados nos grupos AH Plus e Sealapex, mas não para o Endofill após 48 h. O método utilizado permitiu avaliar a citotoxicidade dos cimentos que se difundem pelo ápice radicular.


Assuntos
Humanos , Materiais Restauradores do Canal Radicular/toxicidade , Raiz Dentária/efeitos dos fármacos , Modelos Biológicos , Técnicas In Vitro , Microscopia Eletrônica de Varredura , Linhagem Celular , Meios de Cultura
17.
Braz. oral res. (Online) ; 31: e11, 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-839534

RESUMO

Abstract This study evaluated the removal of filling material with ProTaper Universal Rotary Retreatment system (PTR) combined with solvents and the influence of solvents on the bond strength (PBS) of sealer to intraradicular dentin after canal reobturation. Roots were endodontically treated and distributed to five groups (n = 12). The control group was not retreated. In the four experimental groups, canals were retreated with PTR alone or in combination with xylol, orange oil, and eucalyptol. After filling material removal, two specimens of each group were analysed by SEM and µCT to verify the presence of filling remnants on root canal walls. The other roots were reobturated and sectioned in 1-mm-thick dentin slices that were subjected to the push-out test. Data were analysed by two-way ANOVA and Tukey’s test (α = 0.05). SEM and µCT analysis revealed that all retreatment techniques left filling remnants on canal walls. The control group (3.47 ± 1.21) presented significantly higher (p < 0.05) PBS than the experimental groups. The groups retreated with PTR alone (2.59 ± 0.99) or combined with xylol (2.54 ± 0.77) and orange oil (2.32 ± 0.93) presented similar bond strength (p > 0.05), and differed significantly from the group with eucalyptol (1.89 ± 0.63). The solvents reduced the PBS of the sealer to dentin and no retreatment technique promoted complete removal of filling material.


Assuntos
Humanos , Cavidade Pulpar/efeitos dos fármacos , Dentina/efeitos dos fármacos , Materiais Restauradores do Canal Radicular/química , Preparo de Canal Radicular/métodos , Solventes/química , Análise de Variância , Cicloexanóis/química , Colagem Dentária , Instrumentos Odontológicos , Resinas Epóxi/química , Guta-Percha , Teste de Materiais , Microscopia Eletrônica de Varredura , Monoterpenos/química , Óleos de Plantas/química , Reprodutibilidade dos Testes , Retratamento/instrumentação , Preparo de Canal Radicular/instrumentação
18.
Braz Dent J ; 27(4): 424-9, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27652705

RESUMO

Root canal irrigants are used to minimize the negative effects of smear layer on endodontic sealer retention. The aim of this study was to evaluate the efficacy of agitation of 17% ethylenediaminetetraacetic acid (EDTA) with ultrasonic, 1064-nm Nd:YAG and 980-nm diode laser on the retention of an epoxy-based sealer to the root canal walls. Forty single-rooted bovine teeth were instrumented with ProTaper rotary system and divided into four groups according to the final irrigation protocol (n = 10): (1) 17% EDTA (control); (2) 17% EDTA with 50-s ultrasonic agitation; (3) 17% EDTA with 50-s diode laser (2-W) agitation; and (4) 17% EDTA with 50-s Nd:YAG (1.5-W) laser agitation. After endodontic filling with gutta-percha F5 master cone and Sealer 26, the roots were sectioned at the cervical, middle, and apical root thirds to obtain 1.5-mm slices. Push-out tests were performed using a universal testing machine at a 1 mm/min crosshead speed. Data were analyzed using two-way ANOVA and Tukey's tests (α=0.05). Apical root thirds had significant higher retention values than cervical and middle thirds (p < 0.05). EDTA with 1064-nm Nd:YAG or 980-nm diode laser presented the highest retention values and was significantly different from EDTA with ultrasonic agitation and EDTA only (p < 0.05). Adhesive failures were predominant to EDTA only group. Mixed failures were predominant to all agitation groups. 1064-nm Nd:YAG and 980-nm diode laser EDTA agitation enhanced the retention of the epoxy-based sealer to the root canal walls compared with that due to EDTA only or EDTA with ultrasonic agitation.


Assuntos
Dentina/química , Ácido Edético/química , Resinas Epóxi/química , Lasers , Materiais Restauradores do Canal Radicular/química , Humanos
19.
Braz. dent. j ; 27(4): 430-435, July-Aug. 2016. tab, graf
Artigo em Inglês | LILACS | ID: lil-794606

RESUMO

Abstract The aim of this study was to assess the influence of sealer and light-curing unit on regional bond strength of resin composite to the weakened roots. Ninety roots of incisors were experimentally weakened, subjected to biomechanical preparation and filled with either Endofill, AH Plus or MTA Fillapex The roots were desobturated e reinforced with resin composite and fiber post light-activated with one of the light sources: halogen at 600 mW/ cm2 (QTH-600), LED at 800 mW/ cm2 (LED-800) and LED at 1500 mW/ cm2 (LED-1500). The roots were sectioned in slices from cervical, middle and apical root-reinforcement regions and analyzed by push out test, scanning electron microscopy (SEM) and confocal laser scanning microscopy (CLSM). Bond strength data were analyzed using three-way ANOVA and Tukey´s test (α=0.05). Specimens filled with AH Plus had higher bond strength, followed by MTA Fillapex and Endofill (p<0.05). For light-curing unit, LED-1500 presented superior bond strength than LED-800, which was higher than QTH-600 (p<0.05). The cervical region had the greatest mean values (p<0.05) while apical part showed the lowest bond strength (p<0.05). CLMS revealed remaining filling material in the dentinal tubules for all groups. The eugenol-containing sealer (Endofill) compromised the push-out bond strength of composite resin to the root dentin. Bond strength was favored in the cervical region, and when LED-1500 was used.


Resumo O objetivo neste estudo foi avaliar a influência do cimento endodôntico e da fonte de luz fotoativadora na resistência de união (RU) regional da resina composta às raízes fragilizadas. Noventa raízes de incisivos foram experimentalmente fragilizados, submetidos ao preparo biomecânico e obturadas com Endofill, AH Plus ou MTA Fillapex. Os canais foram desobturados e reforçados com pinos de fibra de vidro e resina composta fotoativada com uma das fontes de luz: halógena a 600 mW/cm2 (QTH-600), diodo emissor de luz a 800 mW/cm2 (LED-800) e LED a 1500 mW/cm2 (LED-1500). As raízes foram seccionadas em slices provenientes dos terços cervical, médio e apical das regiões da raiz reforçada e analisadas por meio do teste de push out, microscopia eletrônica de varredura (MEV) e microscopia confocal de varredura a laser (MCVL). Os dados de resistência de união foram analisados por ANOVA a três critérios e teste de Tukey (α=0,05). Os espécimes obturados com AH Plus apresentaram maior resistência de união, seguido do MTA Fillapex e do Endofill (p<0,05). Para fonte de luz fotoativadora, LED-1500 apresentou resistência de união superior ao LED-800 que foi maior que QTH-600 (p<0,05). A região cervical obteve as maiores médias (p<0,05), enquanto que a região apical apresentou a menor resistência de união (p<0,05). MCVL revelou remanescente de material endodôntico nos túbulos dentinários para todos os grupos. O cimento contendo eugenol (Endofill) comprometeu a resistência de união da resina composta à dentina radicular. A resistência de união foi favorecida na região cervical, e quando o LED-1500 foi empregado.


Assuntos
Humanos , Resinas Compostas , Teste de Materiais , Raiz Dentária
20.
Braz. dent. j ; 27(4): 424-429, July-Aug. 2016. tab
Artigo em Inglês | LILACS | ID: lil-794623

RESUMO

Abstract Root canal irrigants are used to minimize the negative effects of smear layer on endodontic sealer retention. The aim of this study was to evaluate the efficacy of agitation of 17% ethylenediaminetetraacetic acid (EDTA) with ultrasonic, 1064-nm Nd:YAG and 980-nm diode laser on the retention of an epoxy-based sealer to the root canal walls. Forty single-rooted bovine teeth were instrumented with ProTaper rotary system and divided into four groups according to the final irrigation protocol (n = 10): (1) 17% EDTA (control); (2) 17% EDTA with 50-s ultrasonic agitation; (3) 17% EDTA with 50-s diode laser (2-W) agitation; and (4) 17% EDTA with 50-s Nd:YAG (1.5-W) laser agitation. After endodontic filling with gutta-percha F5 master cone and Sealer 26, the roots were sectioned at the cervical, middle, and apical root thirds to obtain 1.5-mm slices. Push-out tests were performed using a universal testing machine at a 1 mm/min crosshead speed. Data were analyzed using two-way ANOVA and Tukey's tests (α=0.05). Apical root thirds had significant higher retention values than cervical and middle thirds (p < 0.05). EDTA with 1064-nm Nd:YAG or 980-nm diode laser presented the highest retention values and was significantly different from EDTA with ultrasonic agitation and EDTA only (p < 0.05). Adhesive failures were predominant to EDTA only group. Mixed failures were predominant to all agitation groups. 1064-nm Nd:YAG and 980-nm diode laser EDTA agitation enhanced the retention of the epoxy-based sealer to the root canal walls compared with that due to EDTA only or EDTA with ultrasonic agitation.


Resumo Irrigantes para canais radiculares são usados para minimizar os efeitos negativos da camada de smear na retenção do cimento obturador. O objetivo deste estudo foi avaliar a eficácia da agitação do ácido etilenodiaminotetracético a 17% (EDTA) com ultrassom, Nd:YAG 1064-nm e laser diodo 980-nm na retenção de um cimento obturador à base de resina epóxica nas paredes do canal radicular. Quarenta dentes bovinos unirradiculares foram instrumentados com o sistema rotatório ProTaper e divididos em quatro grupos de acordo com o protocolo de irrigação final (n = 10): (1) EDTA 17% (controle); (2) EDTA 17% com agitação ultrassônica por 50-s; (3) EDTA 17% com agitação com laser diodo (2-W) por 50-s; e (4) EDTA 17% com agitação com laser Nd:YAG (1,5-W) por 50-s. Após obturação endodôntica com cone principal F5 e cimento Sealer 26, as raízes foram seccionadas nos terços radiculares cervical, médio e apical para obtenção de slices de 1,5-mm. Testes de push-out foram realizados utilizando uma máquina universal de ensaios com velocidade de carga de 1 mm/min. Os dados foram analisados utilizando os testes two-way ANOVA e Tukey's (α=0,05). Os terços radiculares apicais tiveram força de adesão significantemente maior que os terços cervical e médio (p<0,05). EDTA com Nd:YAG 1064-nm ou laser diodo 980-nm apresentaram os maiores valores de força de adesão e foram significantemente diferentes do EDTA com agitação ultrassônica e EDTA apenas (p < 0,05). Falhas adesivas foram predominantes apenas no grupo EDTA. Falhas mistas foram predominantes em todos os grupos de agitação. A agitação do EDTA com Nd:YAG 1064-nm e laser diodo 980-nm aumentou a força de adesão do cimento à base de resina epóxica às paredes do canal radicular comparado com a obtida com EDTA apenas ou EDTA com agitação ultrassônica.


Assuntos
Humanos , Dentina/química , Ácido Edético/química , Resinas Epóxi/química , Lasers , Materiais Restauradores do Canal Radicular/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA