Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Pract Radiat Oncol ; 14(2): e165-e172, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38048988

RESUMO

PURPOSE: The purpose of this work is to develop a method to automate the treatment planning process of craniospinal irradiation (CSI) using volumetric modulated arc therapy. METHODS AND MATERIALS: Two scripts were developed using the Eclipse Scripting Application Programming Interface to perform auto-plan preparation and optimization. Ten patients (age, 5-44 years) previously treated at our institution with low dose volumetric modulated arc therapy CSI (prescription of 12 Gy) before total body irradiation were selected to evaluate the efficacy of the proposed auto-planning process. Paired t tests compared the dosimetric indices of the auto-plans to the manually generated clinical plans. All plans were normalized to 95% of planning target volume (PTV) coverage with the prescription dose. Two physicians and one physicist were asked to evaluate the manual plans and auto-plans of each patient in a blinded retrospective review and to indicate clinical acceptability and which plans were preferred for treatment. RESULTS: Compared with the manual CSI plans, the auto plans obtained significant reductions in Dmean to the parotids, submandibular glands, larynx, thyroid, and significant reduction in the plan PTV Dmax and D0.03 cc. The standard deviation range of the dosimetric parameters was greatly reduced for auto plans (range, 0.1-1.3 Gy) relative to manual plans (range, 0.4-5.9 Gy) indicating better plan consistency. Among the 10 patients, the auto-plans were preferred over the manual plans 90% of the time by the reviewing experts. The required time for auto-planning was approximately 1 hour compared with estimated 4 or more hours for manual planning. CONCLUSIONS: Reductions in planning time without sacrifices in plan quality were obtained using the auto-planning process compared with manual planning. Variation in plan quality was also reduced. The auto-planning scripts will be made freely available to other institutions and clinics.


Assuntos
Radiação Cranioespinal , Médicos , Radioterapia de Intensidade Modulada , Humanos , Pré-Escolar , Criança , Adolescente , Adulto Jovem , Adulto , Instalações de Saúde , Glândula Parótida
2.
J Appl Clin Med Phys ; 24(2): e13820, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36325743

RESUMO

PURPOSE: To develop an independent log file-based intensity-modulated radiation therapy (IMRT) quality assurance (QA) tool for the 0.35 T magnetic resonance-linac (MR-linac) and investigate the ability of various IMRT plan complexity metrics to predict the QA results. Complexity metrics related to tissue heterogeneity were also introduced. METHODS: The tool for particle simulation (TOPAS) Monte Carlo code was utilized with a previously validated linac head model. A cohort of 29 treatment plans was selected for IMRT QA using the developed QA tool and the vendor-supplied adaptive QA (AQA) tool. For 27 independent patient cases, various IMRT plan complexity metrics were calculated to assess the deliverability of these plans. A correlation between the gamma pass rates (GPRs) from the AQA results and calculated IMRT complexity metrics was determined using the Pearson correlation coefficients. Tissue heterogeneity complexity metrics were calculated based on the gradient of the Hounsfield units. RESULTS: The median and interquartile range for the TOPAS GPRs (3%/3 mm criteria) were 97.24% and 3.75%, respectively, and were 99.54% and 0.36% for the AQA tool, respectively. The computational time for TOPAS ranged from 4 to 8 h to achieve a statistical uncertainty of <1.5%, whereas the AQA tool had an average calculation time of a few minutes. Of the 23 calculated IMRT plan complexity metrics, the AQA GPRs had correlations with 7 out of 23 of the calculated metrics. Strong correlations (|r| > 0.7) were found between the GPRs and the heterogeneity complexity metrics introduced in this work. CONCLUSIONS: An independent MC and log file-based IMRT QA tool was successfully developed and can be clinically deployed for offline QA. The complexity metrics will supplement QA reports and provide information regarding plan complexity.


Assuntos
Radioterapia de Intensidade Modulada , Humanos , Radioterapia de Intensidade Modulada/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Simulação por Computador , Dosagem Radioterapêutica , Aceleradores de Partículas , Imageamento por Ressonância Magnética
3.
Med Phys ; 48(4): 1967-1982, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33555052

RESUMO

PURPOSE: The aim of this work was to develop and benchmark a magnetic resonance (MR)-guided linear accelerator head model using the GEANT4 Monte Carlo (MC) code. The validated model was compared to the treatment planning system (TPS) and was also used to quantify the electron return effect (ERE) at a lung-water interface. METHODS: The average energy, including the spread in the energy distribution, and the radial intensity distribution of the incident electron beam were iteratively optimized in order to match the simulated beam profiles and percent depth dose (PDD) data to measured data. The GEANT4 MC model was then compared to the TPS model using several photon beam tests including oblique beams, an off-axis aperture, and heterogeneous phantoms. The benchmarked MC model was utilized to compute output factors (OFs) with the 0.35 T magnetic field turned on and off. The ERE was quantified at a lung-water interface by simulating PDD curves with and without the magnetic field for 6.6 × 6.6  cm 2 and 2.5 × 2.5  cm 2 field sizes. A 2%/2 mm gamma criterion was used to compare the MC model with the TPS data throughout this study. RESULTS: The final incident electron beam parameters were 6.0 MeV average energy with a 1.5 MeV full width at half maximum (FWHM) Gaussian energy spread and a 1.0 mm FWHM Gaussian radial intensity distribution. The MC-simulated OFs were found to be in agreement with the TPS-calculated and measured OFs, and no statistical difference was observed between the 0.35 T and 0.0 T OFs. Good agreement was observed between the TPS-calculated and MC-simulated data for the photon beam tests with gamma pass rates ranging from 96% to 100%. An increase of 4.3% in the ERE was observed for the 6.6 × 6.6  cm 2 field size relative to the 2.5 × 2.5  cm 2 field size. The ratio of the 0.35 T PDD to the 0.0 T PDD was found to be up to 1.098 near lung-water interfaces for the 6.6 × 6.6  cm 2 field size using the MC model. CONCLUSIONS: A vendor-independent Monte Carlo model has been developed and benchmarked for a 0.35 T/6 MV MR-linac. Good agreement was obtained between the GEANT4 and TPS models except near heterogeneity interfaces.


Assuntos
Aceleradores de Partículas , Planejamento da Radioterapia Assistida por Computador , Método de Monte Carlo , Imagens de Fantasmas , Dosagem Radioterapêutica
4.
Med Phys ; 48(1): 366-375, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33107049

RESUMO

PURPOSE: The dosimetric properties of inverse Compton (IC) x-ray sources were investigated to determine their utility for stereotactic radiation therapy. METHODS: Monte Carlo simulations were performed using the egs brachy user code of EGSnrc. Nominal IC source x-ray energies of 80 and 150 keV were considered in this work. Depth-dose and lateral dose profiles in water were calculated, as was dose enhancement in the bone. Further simulations were performed for brain and spine treatment sites. The impact of gold nanoparticle doping was also investigated for the brain treatment site. Analogous dose calculations were performed in a clinical treatment planning system using a clinical 6 MV photon beam model and were compared to the Monte Carlo simulations. RESULTS: Both 80 and 150 keV IC beams were observed to have sharp 80-20 penumbra (i.e., < 0.1 mm) with broad low-dose tails in water. For reference, the calculated penumbra for the 6 MV clinical beam was 3 mm. Maximum dose enhancement factors in bone of 3.1, 1.4, and 1.1 were observed for the 80, 150 keV, and clinical 6 MV beams, respectively. The plan quality for the single brain metastasis case was similar between the IC beams and the 6 MV beam without gold nanoparticles. As the concentration of gold within the target increased, the V12 Gy to the normal brain tissue and D max within the target volume significantly decreased and the conformity significantly improved, which resulted in superior plan quality over the clinical 6 MV beam plan. In the spine cases, the sharp penumbra and enhanced dose to bone of the IC beams produced superior plan quality (i.e., better conformity, normal tissue sparing, and spinal cord sparing) as compared to the clinical 6 MV beam plans. CONCLUSIONS: The findings from this work indicate that inverse Compton x-ray sources are well suited for stereotactic radiotherapy treatments due to their sharp penumbra and dose enhancement around high atomic number materials. Future work includes investigating the properties of intensity-modulated inverse Compton x-ray sources to improve the homogeneity within the target tissue.


Assuntos
Nanopartículas Metálicas , Radiocirurgia , Ouro , Método de Monte Carlo , Radioterapia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA