Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Breast Cancer Res ; 8(1): R8, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16417651

RESUMO

INTRODUCTION: Current and recent users of hormone replacement therapy (HRT) have an increased risk of being recalled to assessment at mammography without breast cancer being diagnosed ('false positive recall'), but there is limited information on the effects of different patterns of HRT use on this. The aim of this study is to investigate in detail the relationship between patterns of use of HRT and false positive recall. METHODS: A total of 87,967 postmenopausal women aged 50 to 64 years attending routine breast cancer screening at 10 UK National Health Service Breast Screening Units from 1996 to 1998 joined the Million Women Study by completing a questionnaire before screening and were followed for their screening outcome. RESULTS: Overall, 399 (0.5%) participants were diagnosed with breast cancer and 2,629 (3.0%) had false positive recall. Compared to never users of HRT, the adjusted relative risk (95% CI) of false positive recall was: 1.62 (1.43-1.83), 1.80 (1.62-2.01) and 0.76 (0.52-1.10) in current users of oestrogen-only HRT, oestrogen-progestagen HRT and tibolone, respectively (p (heterogeneity) < 0.0001); 1.65 (1.43-1.91), 1.49 (1.22-1.81) and 2.11 (1.45-3.07) for current HRT used orally, transdermally or via an implant, respectively (p (heterogeneity) = 0.2); and 1.84 (1.67-2.04) and 1.75 (1.49-2.06) for sequential and continuous oestrogen-progestagen HRT, respectively (p (heterogeneity) = 0.6). The relative risk of false positive recall among current users appeared to increase with increasing time since menopause, but did not vary significantly according to any other factors examined, including duration of use, hormonal constituents, dose, whether single- or two-view screening was used, or the woman's personal characteristics. CONCLUSION: Current use of oestrogen-only and oestrogen-progestagen HRT, but not tibolone, increases the risk of false positive recall at screening.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Terapia de Reposição de Estrogênios , Mamografia/normas , Moduladores de Receptor Estrogênico/uso terapêutico , Reações Falso-Positivas , Feminino , Humanos , Programas de Rastreamento , Pessoa de Meia-Idade , Norpregnenos/uso terapêutico , Pós-Menopausa , Progestinas/uso terapêutico , Reprodutibilidade dos Testes , Fatores de Risco , Sensibilidade e Especificidade
2.
BMJ ; 329(7464): 477, 2004 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-15331472

RESUMO

OBJECTIVES: To examine how lifestyle, hormonal, and other factors influence the sensitivity and specificity of mammography. METHODS: Women recruited into the Million Women Study completed a questionnaire about various personal factors before routine mammographic screening. A sample of 122,355 women aged 50-64 years were followed for outcome of screening and incident breast cancer in the next 12 months. Sensitivity and specificity were calculated by using standard definitions, with adjustment for potential confounding factors. RESULTS: Breast cancer was diagnosed in 726 (0.6%) women, 629 in screen positive and 97 in screen negative women; 3885 (3.2%) were screen positive but had no subsequent diagnosis of breast cancer. Overall sensitivity was 86.6% and specificity was 96.8%. Three factors had an adverse effect on both measures: use of hormone replacement therapy (sensitivity: 83.0% (95% confidence interval 77.4% to 87.6%), 84.7% (73.9% to 91.6%), and 92.1% (87.6% to 95.0%); specificity: 96.8% (96.6% to 97.0%), 97.8% (97.5% to 98.0%), and 98.1% (98.0% to 98.2%), respectively, for current, past, and never use); previous breast surgery v no previous breast surgery (sensitivity: 83.5% (75.7% to 89.1%) v 89.4% (86.5% to 91.8%); specificity: 96.2% (95.8% to 96.5%) v 97.4% (97.3% to 97.5%), respectively); and body mass index < 25 v > or = 25 (sensitivity: 85.7% (81.2% to 89.3%) v 91.0% (87.5% to 93.6%); specificity: 97.2% (97.0% to 97.3%) v 97.4% (97.3% to 97.6%), respectively). Neither sensitivity nor specificity varied significantly according to age, family history of breast cancer, parity, past oral contraceptive use, tubal ligation, physical activity, smoking, or alcohol consumption. CONCLUSIONS: The efficiency, and possibly the effectiveness, of mammographic screening is lower in users of hormone replacement therapy, in women with previous breast surgery, and in thin women compared with other women.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mamografia/normas , Índice de Massa Corporal , Neoplasias da Mama/psicologia , Neoplasias da Mama/cirurgia , Estudos de Coortes , Feminino , Terapia de Reposição Hormonal , Humanos , Estilo de Vida , Programas de Rastreamento/métodos , Menopausa , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Prognóstico , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA