Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Card Surg ; 37(9): 2923-2926, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35665964

RESUMO

BACKGROUND: Postoperative pain after cardiac surgery is a very important issue and affects recovery, risk of postoperative complications and quality of life. The pain management has been traditionally based on intravenous opioids with growing evidence suggesting the use of opioid-free and opioid-sparing techniques to reduce its adverse effects. CASE PRESENTATION: We report the case of a 75-year-old frail patient underwent awake mediastinal revision with subxiphoid access due to deep sternal wound infection using a pectoralis-intercostal rectus sheath (PIRS) plane block. During the procedure the patient never reported pain receiving acetaminophen 1 g every 8 h for postoperative pain management without others pain relievers. CONCLUSION: Ultrasound guided PIRS block could be an effective and safe analgesic technique to manage sternal and subxiphoid drainage pain in patients undergoing cardiac surgery via subxiphoid approach.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Bloqueio Nervoso , Idoso , Analgésicos Opioides , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Humanos , Bloqueio Nervoso/métodos , Dor Pós-Operatória , Qualidade de Vida , Ultrassonografia de Intervenção/métodos , Vigília
2.
J Heart Lung Transplant ; 40(8): 794-804, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34134912

RESUMO

BACKGROUND: Donor-derived cell-free DNA (dd-cfDNA) is considered a reliable marker of organ damage with potential applications in the follow-up of transplant recipients. METHODS: In this work we present an assay based on the donor-recipient HLA-mismatch (human leukocyte antigen) at the HLA-DRB1 locus to monitor rejection by quantifying the percentage of dd-cfDNA using a droplet digital PCR (polymerase chain reaction) technique. A panel of probes targeting the HLA-DRB1 locus and covering >85% genetic variability was validated and used to assess dd-cfDNA levels in a prospective cohort of 19 adult heart transplant recipients (mean age 50.9±14.8 years). The assay was carried out on a total of 232 liquid biopsies collected at the same time as endomyocardial biopsy (EMB) during routine post-transplant follow-up. RESULTS: Results show a significant increase of dd-cfDNA related to ischemia-reperfusion injury (2.22±2.09%) and to acute cellular rejection (1.71±3.10%) compared to stable conditions (0.43±1.04%, p < 0.0001). On the contrary, no increase was observed during infections or vascular complications, underlining the potential role of this biomarker for rejection monitoring. With a cut-off of 0.11%, the test showed 70.8% specificity (95% CI, 58.17% - 81.40%) and 64.2% sensitivity (95% CI, 49.80% - 76.86%) in discriminating acute rejection from no rejection. CONCLUSIONS: These data demonstrate that this HLA mismatch-based droplet digital PCR method is effective for monitoring rejection in heart transplant recipients. Compared to next generation sequencing approaches, it is far more flexible, less expensive and provides faster results.


Assuntos
Ácidos Nucleicos Livres/sangue , Rejeição de Enxerto/genética , Cadeias HLA-DRB1/genética , Transplante de Coração , Doadores de Tecidos , Transplantados , Biomarcadores/sangue , Ácidos Nucleicos Livres/genética , Feminino , Rejeição de Enxerto/sangue , Rejeição de Enxerto/imunologia , Cadeias HLA-DRB1/sangue , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos
3.
Membranes (Basel) ; 11(5)2021 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-33946566

RESUMO

Since the beginning of the COVID-19 emergency, the referral Intensive Care Unit for the Extracorporeal Membrane Oxygenation (ECMO) support of Piedmont Region (Italy), in cooperation with infectious disease specialists, perfusionists and cardiac surgeons, developed a protocol to guarantee operator safety during invasive procedures, among which the ECMO positioning or inter-hospital transport. The use of powered air-purifying respirators, filtering facepiece particles (FFP) 2-3 masks, protective suits, disposable sterile surgical gowns, and two pairs of sterile gloves as a part of a protocol seemed effective and feasible for trained healthcare workers and allow all the complex activities connected with the positioning of the ECMO support to be completed effectively. The simulation training on donning and doffing procedures and the presence of a dedicated team member to verify the compliance with the safety procedure effectively reassured operators and likely reduced the risk of self-contamination. From 1 March to 31 December 2020, we used the procedure in 35 severe acute respiratory distress syndrome (ARDS) patients and one acute respiratory failure caused by neoplastic total tracheal obstruction, all positive to COVID-19, to be connected to veno-venous ECMO in peripheral hospitals and centralized for ECMO management. This preliminary experience seems to confirm that the use of ECMO during COVID-19 outbreaks is feasible and the risks associated with its positioning and management are sustainable for the health-care workers and safe for patients.

4.
Tex Heart Inst J ; 47(4): 302-305, 2020 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-33472226

RESUMO

Cardiac involvement in familial amyloid polyneuropathy consists of arrhythmias, conduction disturbances, and heart failure. To our knowledge, heart rupture has never been described in association with this condition. We report the case of a 62-year-old man with a 6-year history of refractory familial amyloid polyneuropathy who underwent liver transplantation. The operation was complicated by severe hypotension because the neuropathy involved the autonomic system. Perioperatively, the patient had a myocardial infarction, and during the next 10 days, a complete interventricular septal rupture developed, resulting in a systemic-to-pulmonary shunt. Coronary angiographic findings were normal. However, the shunt caused unstable hemodynamics, resulting in cardiogenic shock. An attempt to close the rupture percutaneously failed. The patient underwent successful heart transplantation 50 days later. Macroscopic examination of the explanted heart showed thickening of both ventricles, septal rupture, and a gray scar in the interventricular septum around the cavity. Histopathologic examination revealed intramural amyloid angiopathy. Our case shows that heart rupture can occur in patients with familial amyloid polyneuropathy who have no history of obstructive coronary artery disease, perhaps as a result of tissue fragility caused by amyloid angiopathy. Therefore, autonomic disturbances should be regarded with concern and promptly treated in the perioperative period.


Assuntos
Neuropatias Amiloides Familiares/complicações , Ruptura do Septo Ventricular/etiologia , Neuropatias Amiloides Familiares/diagnóstico , Procedimentos Cirúrgicos Cardíacos/métodos , Ecocardiografia , Eletrocardiografia , Humanos , Masculino , Pessoa de Meia-Idade , Ruptura do Septo Ventricular/diagnóstico , Ruptura do Septo Ventricular/cirurgia
5.
Ther Adv Respir Dis ; 13: 1753466619878555, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31566097

RESUMO

BACKGROUND: There is no univocal prophylactic regimen to prevent cytomegalovirus (CMV) infection/disease in lung transplantation (LT) recipients. The aim of this study is to evaluate short-term clinical outcomes of a tailored combined CMV management approach. METHODS: After 1-year follow up, 43 LT patients receiving combined CMV prophylaxis with antiviral agents and CMV-specific IgG were evaluated in a retrospective observational study. Systemic and lung viral infections were investigated by molecular methods on a total of 1134 whole blood and 167 bronchoalveolar lavage (BAL) and biopsy specimens. CMV immunity was assessed by ELISPOT assay. Clinical and therapeutic data were also evaluated. RESULTS: We found 2/167 cases of CMV pneumonia (1.2%), both in the donor-positive/recipient-positive (D+/R+) population, and 51/167 cases of CMV pulmonary infection (BAL positivity 30.5%). However, only 32/167 patients (19.1%) were treated due to their weak immunological response at CMV ELISPOT assay. Viremia ⩾100,000 copies/mL occurred in 33/1134 specimens (2.9%). Regarding CMV-serological matching (D/R), the D+/R- population had more CMV viremia episodes (p < 0.05) and fewer viremia-free days (p < 0.001). CONCLUSIONS: Compared to previous findings, our study shows a lower incidence of CMV pneumonia and viremia despite the presence of a substantial CMV load. In addition, our findings further confirm the D+/R- group to be a high-risk population for CMV viremia. Overall, a good immunological response seems to protect patients from CMV viremia and pneumonia but not from CMV alveolar replication. The reviews of this paper are available via the supplemental material section.


Assuntos
Antivirais/administração & dosagem , Infecções por Citomegalovirus/prevenção & controle , Citomegalovirus/efeitos dos fármacos , Imunoglobulina G/administração & dosagem , Transplante de Pulmão/efeitos adversos , Infecções Oportunistas/prevenção & controle , Pneumonia Viral/prevenção & controle , Adulto , Antivirais/efeitos adversos , Citomegalovirus/crescimento & desenvolvimento , Citomegalovirus/imunologia , Infecções por Citomegalovirus/diagnóstico , Infecções por Citomegalovirus/imunologia , Infecções por Citomegalovirus/virologia , Esquema de Medicação , Feminino , Humanos , Hospedeiro Imunocomprometido , Imunoglobulina G/efeitos adversos , Imunossupressores/efeitos adversos , Masculino , Pessoa de Meia-Idade , Infecções Oportunistas/diagnóstico , Infecções Oportunistas/imunologia , Infecções Oportunistas/virologia , Pneumonia Viral/diagnóstico , Pneumonia Viral/imunologia , Pneumonia Viral/virologia , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Carga Viral , Replicação Viral
6.
Ann Cardiothorac Surg ; 8(1): 54-61, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30854312

RESUMO

BACKGROUND: Lung transplantation is the treatment of choice for end-stage pulmonary disease in selected patients. However, severe primary graft dysfunction is a significant complication of transplant and requires the implantation of an extracorporeal support. The aim of the study is to evaluate the impact of extracorporeal membrane oxygenation (ECMO) after transplant in our center. METHODS: From January 2008 till June 2018, 195 consecutive unselected patients receiving a lung transplant were considered. Mean age was 49±15 years. Main indications for transplant were idiopathic pulmonary fibrosis in 72 patients, chronic obstructive pulmonary disease in 60 patients, and cystic fibrosis in 40 patients. Prior to transplant, 18 patients were on mechanical ventilation and 14 were on ECMO. RESULTS: Twenty-five patients required venous-venous ECMO after transplant. Vascular disease as cause of transplant [relative risk (RR) 7.8, 95% CI: 1.5-41, P=0.02], donor age (RR 1.6, 95% CI: 1.03-2.3, P=0.03) and need for cardiopulmonary by-pass during transplant (RR 3.1, 95% CI: 1.02-9, P=0.04) were associated with ECMO implantation. Patients requiring post-transplant ECMO received more transfusions (P<0.01), had a longer mechanical ventilation (P<0.01) and ICU stay (P<0.01) and had a higher hospital mortality (P<0.01). Post-transplant ECMO significantly influenced one- and five-year survival [hazard ratio (HR) 5.5, 95% CI: 3-10, P<0.001 and HR 3.5, 95% CI: 2-6, P<0.001, respectively]. However, conditional survival after t months is similar for patients with or without post-transplant ECMO. CONCLUSIONS: In our experience, although ECMO is a reliable and effective strategy to support pulmonary function, severe graft dysfunction after lung transplantation still has a significant impact on early and late results.

7.
J Card Surg ; 32(2): 166-167, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28097728

RESUMO

We report a case of a patient supported with a HeartWare left ventricular assist device for idiopathic cardiomyopathy who was resistance to vitamin-K antagonists three months after implantation. The patient initially started low-molecular-weight heparin therapy and then, after the onset of an ischemic stroke, switched to dabigatran etexilate (DE). The patient had progressive recovery of cardiac function for which the device was explanted. No thrombotic or bleeding events occurred during DE therapy.


Assuntos
Cardiomiopatia Dilatada/cirurgia , Dabigatrana/administração & dosagem , Coração Auxiliar , Cuidados Pós-Operatórios/métodos , Trombose/prevenção & controle , Vitamina K/antagonistas & inibidores , Idoso , Antitrombinas/administração & dosagem , Feminino , Seguimentos , Coração Auxiliar/efeitos adversos , Humanos , Trombose/etiologia
8.
Interact Cardiovasc Thorac Surg ; 18(4): 415-7, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24431003

RESUMO

OBJECTIVES: Driveline infections are one of the most common and important complications in patients with left ventricular assist device (LVAD). One of the causes favouring the development of this complication is the traumatism of the exit site, which occurs in response to movement of the driveline. In this work, we present a simple and feasible method to immobilize the driveline at the level of the exit site. METHODS: From April 2013 until November 2013, 6 patients underwent implantation of HeartWare LVAD (HVAD) for an end-stage heart failure. When the patient has begun to mobilize after the implantation of the device, we have combined the use of two components with the aim of securing the driveline to the patient's skin: a StatLock system and a silicone suture. RESULTS: No case of local traumatism and no case of local infection at the driveline were observed during the follow-up. No patient reported pain or swelling at the driveline exit site. All patients were satisfied with their quality-of-life and they do not report any limitations in their daily activities. CONCLUSIONS: One of the major long-term complications in patients with LVAD is the development of infections of the exit site of the driveline. The trauma of this skin region promotes the onset and maintenance of an inflammatory process and local infectious. Avoiding excessive mobilization of the driveline is likely to reduce the incidence of infections of the exit site and improve the quality-of-life.


Assuntos
Insuficiência Cardíaca/terapia , Coração Auxiliar/efeitos adversos , Infecções Relacionadas à Prótese/prevenção & controle , Técnicas de Sutura , Função Ventricular Esquerda , Adulto , Idoso , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/microbiologia , Sistema de Registros , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA