Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Biomed Opt Express ; 15(3): 1777-1784, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38495685

RESUMO

Biomechanical testing of human skin in vivo is important to study the aging process and pathological conditions such as skin cancer. Brillouin microscopy allows the all-optical, non-contact visualization of the mechanical properties of cells and tissues over space. Here, we use the combination of Brillouin microscopy and optical coherence tomography for motion-corrected, depth-resolved biomechanical testing of human skin in vivo. We obtained two peaks in the Brillouin spectra for the epidermis, the first at 7 GHz and the second near 9-10 GHz. The experimentally measured Brillouin frequency shift of the dermis is lower compared to the epidermis and is 6.8 GHz, indicating the lower stiffness of the dermis.

2.
Materials (Basel) ; 15(23)2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-36500053

RESUMO

The measurement of the biomechanical properties of the skin is of great interest since these properties play an important role in the development of several diseases such as skin cancer and systemic sclerosis. In this direction, several diagnostic tools have been developed to analyze the mechanical properties of the skin. Optical coherence elastography (OCE) is one of the emerging imaging techniques used for the characterization of the mechanical properties of the tissue quantitatively. In systemic sclerosis patients, the measurement of the mechanical properties of the deeper skin layers is desirable compared to the superficial layers. There are several variants of OCE that exist, but it is still not clear which method is more suitable for the measurement of the mechanical properties of the deeper tissue. In this work, we tested three common methods, the pulsed excitation method, the continuous wave excitation method, and the resonant frequency method, for the measurement of the mechanical properties of the deeper layers in the tissue. We found out that the pulsed wave excitation method provides the most reliable measurements in the shortest possible time compared to the other two methods.

3.
Clin Gastroenterol Hepatol ; 20(4): 756-765.e3, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-33549871

RESUMO

BACKGROUND & AIMS: Tethered capsule endomicroscopy (TCE) involves swallowing a small tethered pill that implements optical coherence tomography (OCT) imaging, procuring high resolution images of the whole esophagus. Here, we demonstrate and evaluate the feasibility and safety of TCE and a portable OCT imaging system in patients with Barrett's esophagus (BE) in a multi-center (5-site) clinical study. METHODS: Untreated patients with BE as per endoscopic biopsy diagnosis were eligible to participate in the study. TCE procedures were performed in unsedated patients by either doctors or nurses. After the capsule was swallowed, the device continuously obtained 10-µm-resolution cross-sectional images as it traversed the esophagus. Following imaging, the device was withdrawn through mouth, and disinfected for subsequent reuse. BE lengths were compared to endoscopy findings when available. OCT-TCE images were compared to volumetric laser endomicroscopy (VLE) images from a patient who had undergone VLE on the same day as TCE. RESULTS: 147 patients with BE were enrolled across all sites. 116 swallowed the capsule (79%), 95/114 (83.3%) men and 21/33 (63.6%) women (P = .01). High-quality OCT images were obtained in 104/111 swallowers (93.7%) who completed the procedure. The average imaging duration was 5.55 ± 1.92 minutes. The mean length of esophagus imaged per patient was 21.69 ± 5.90 cm. A blinded comparison of maximum extent of BE measured by OCT-TCE and EGD showed a strong correlation (r = 0.77-0.79). OCT-TCE images were of similar quality to those obtained by OCT-VLE. CONCLUSIONS: The capabilities of TCE to be used across multiple sites, be administered to unsedated patients by either physicians or nurses who are not expert in OCT-TCE, and to rapidly and safely evaluate the microscopic structure of the esophagus make it an emerging tool for screening and surveillance of BE patients. Clinical trial registry website and trial number: NCT02994693 and NCT03459339.


Assuntos
Esôfago de Barrett , Neoplasias Esofágicas , Esôfago de Barrett/diagnóstico por imagem , Esôfago de Barrett/patologia , Biópsia , Neoplasias Esofágicas/patologia , Esofagoscopia/métodos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Tomografia de Coerência Óptica/métodos
4.
J Biophotonics ; 14(2): e202000324, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33131174

RESUMO

Multimodal low-cost endoscopy is highly desirable in poor resource settings such as in developing nations. In this work, we developed a smartphone-based low-cost, reusable tethered capsule endoscopic platform that allows white-light, narrowband, and fluorescence/autofluorescence imaging of the esophagus. The ex-vivo studies of swine esophagus were performed and compared with a commercial endoscope to test the white-light imaging capabilities of the endoscope. The efficacy of the capsule for narrow-band imaging was tested by imaging the vascularization of the tongue. To determine the autofluorescence/fluorescence capability of the endoscope, fluorescein dye with different concentrations was imaged. Furthermore, swine esophagus injected with fluorescein dye was imaged using the fluorescence/autofluorescence and the white-light imaging modules, ex-vivo. The overall cost of the capsules is approximately 12 €, 15 €, and 42 € for the white light imaging, the narrow-band imaging, and the fluorescence/autofluorescence imaging respectively. In addition, the cost of the laser source module required for the narrow-band imaging and the fluorescence/autofluorescence imaging is approximately 218 €. This device will open the possibility of imaging the esophagus in underprivileged areas.


Assuntos
Esôfago de Barrett , Endoscópios , Endoscopia , Humanos , Imagem Óptica , Smartphone
5.
J Biophotonics ; 13(12): e202000134, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32738024

RESUMO

Lead by the original idea to perform noninvasive optical biopsies of various tissues, optical coherence tomography found numerous medical applications within the last two decades. The interference based imaging technique opens the possibility to visualise subcellular morphology up to an imaging depth of 3 mm and up to micron level axial and lateral resolution. The birefringence properties of the tissue are visualised with enhanced contrast using polarisation sensitive or cross-polarised optical coherence tomography (OCT) techniques. Although, it requires strict control over the polarisation states, resulting in several polarisation controlling elements. In this work, we propose a novel input-polarisation independent endoscopic system based on cross-polarised OCT. We tested the feasibility of our approach by measuring the polarisation change from a quarter-wave plate for different rotational angles. Further performance tests reveal a lateral resolution of 30 µm and a sensitivity of 103 dB. Images of the human nail bed and cow muscle tissue demonstrate the potential of the system to measure structural and birefringence properties of the tissue endoscopically.


Assuntos
Endoscopia , Tomografia de Coerência Óptica , Animais , Birrefringência , Bovinos , Feminino , Humanos
6.
Arch Pathol Lab Med ; 143(3): 314-318, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30550349

RESUMO

CONTEXT.­: The accuracy of needle biopsy for the detection of prostate cancer is limited by well-known sampling errors. Thus, there is an unmet need for a microscopic screening tool that can screen large regions of the prostate comprehensively for cancer. Previous prostate imaging by optical coherence tomography (OCT) has had insufficient resolution for imaging cellular features related to prostate cancer. We have recently developed micro-optical coherence tomography (µOCT) that generates depth-resolved tissue images at a high frame rate with an isotropic resolution of 1 µm. OBJECTIVE.­: To demonstrate that optical images obtained with µOCT provide cellular-level contrast in prostate specimens that will enable differentiation and diagnosis of prostate pathologies. DESIGN.­: Fresh prostate specimens obtained from surgical resections were scanned with µOCT ex vivo. Histologic features in the µOCT images were correlated to the corresponding conventional histology. RESULTS.­: Findings indicate that µOCT is capable of resolving many of the architectural and cellular features associated with benign and neoplastic prostate. CONCLUSIONS.­: Because µOCT can be implemented in a small-diameter flexible probe, this study suggests that high-resolution µOCT imaging may be a useful tool for needle-based virtual biopsy of the prostate gland.


Assuntos
Diagnóstico por Imagem/métodos , Próstata/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Humanos , Masculino
7.
Lasers Surg Med ; 50(3): 230-235, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29105794

RESUMO

BACKGROUND AND OBJECTIVES: Endoscopic optical coherence tomography probes suffer from various artifacts due to dispersion imbalance and polarization mismatch between reference and sample arm light. Such artifacts can be minimized using a common path approach. In this work, we demonstrate a miniaturized common path probe for optical coherence tomography using an inline fiber mirror. MATERIALS AND METHODS: A common path optical fiber probe suitable for performing high-resolution endoscopic optical coherence tomography imaging was developed. To achieve common path functionality, an inline fiber mirror was fabricated using a thin gold layer. A commercially available swept source engine was used to test the designed probe in a cadaver human coronary artery ex vivo. RESULTS: We achieved a sensitivity of 104 dB for this probe using a swept source optical coherence tomography system. To test the probe, images of a cadaver human coronary artery were obtained, demonstrating the quality that is comparable to those obtained by OCT systems with separate reference arms. Additionally, we demonstrate recovery of ranging depth by use of a Michelson interferometer in the detection path. CONCLUSION: We developed a miniaturized monolithic inline fiber mirror-based common path probe for optical coherence tomography. Owing to its simplicity, our design will be helpful in endoscopic applications that require high-resolution probes in a compact form factor while reducing system complexity. Lasers Surg. Med. 50:230-235, 2018. © 2017 Wiley Periodicals, Inc.


Assuntos
Vasos Coronários/diagnóstico por imagem , Tecnologia de Fibra Óptica , Fibras Ópticas , Tomografia de Coerência Óptica , Cadáver , Desenho de Equipamento , Humanos
8.
Lasers Surg Med ; 49(3): 312-318, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27490964

RESUMO

BACKGROUND AND OBJECTIVES: Optical coherence tomography (OCT) catheters for intraluminal imaging are subject to various artifacts due to reference-sample arm dispersion imbalances and sample arm beam astigmatism. The goal of this work was to develop a probe that minimizes such artifacts. MATERIALS AND METHODS: Our probe was fabricated using a single mode fiber at the tip of which a glass spacer and graded index objective lens were spliced to achieve the desired focal distance. The signal was reflected using a curved reflector to correct for astigmatism caused by the thin, protective, transparent sheath that surrounds the optics. The probe design was optimized using Zemax, a commercially available optical design software. Common path interferometric operation was achieved using Fresnel reflection from the tip of the focusing graded index objective lens. The performance of the probe was tested using a custom designed spectrometer-based OCT system. RESULTS: The probe achieved an axial resolution of 15.6 µm in air, a lateral resolution 33 µm, and a sensitivity of 103 dB. A scattering tissue phantom was imaged to test the performance of the probe for astigmatism correction. Images of the phantom confirmed that this common-path, astigmatism-corrected OCT imaging probe had minimal artifacts in the axial, and lateral dimensions. CONCLUSIONS: In this work, we developed an astigmatism-corrected, common path probe that minimizes artifacts associated with standard OCT probes. This design may be useful for OCT applications that require high axial and lateral resolutions. Lasers Surg. Med. 49:312-318, 2017. © 2016 Wiley Periodicals, Inc.


Assuntos
Astigmatismo/diagnóstico por imagem , Desenho de Equipamento , Tecnologia de Fibra Óptica/métodos , Tomografia de Coerência Óptica/instrumentação , Astigmatismo/cirurgia , Segurança de Equipamentos , Humanos , Microcirurgia/métodos , Imagens de Fantasmas
9.
Biomed Opt Express ; 7(7): 2494-505, 2016 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-27446685

RESUMO

We have designed and fabricated a 4 mm diameter rigid endoscopic probe to obtain high resolution micro-optical coherence tomography (µOCT) images from the tracheal epithelium of living swine. Our common-path fiber-optic probe used gradient-index focusing optics, a selectively coated prism reflector to implement a circular-obscuration apodization for depth-of-focus enhancement, and a common-path reference arm and an ultra-broadbrand supercontinuum laser to achieve high axial resolution. Benchtop characterization demonstrated lateral and axial resolutions of 3.4 µm and 1.7 µm, respectively (in tissue). Mechanical standoff rails flanking the imaging window allowed the epithelial surface to be maintained in focus without disrupting mucus flow. During in vivo imaging, relative motion was mitigated by inflating an airway balloon to hold the standoff rails on the epithelium. Software implemented image stabilization was also implemented during post-processing. The resulting image sequences yielded co-registered quantitative outputs of airway surface liquid and periciliary liquid layer thicknesses, ciliary beat frequency, and mucociliary transport rate, metrics that directly indicate airway epithelial function that have dominated in vitro research in diseases such as cystic fibrosis, but have not been available in vivo.

10.
Sci Rep ; 6: 23107, 2016 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-26976363

RESUMO

Time-domain spectroscopy using coherent millimeter and sub-millimeter radiation (also known as terahertz radiation) is rapidly expanding its application, owing greatly to the remarkable advances in generating and detecting such radiation. However, many current techniques for coherent terahertz detection have limited dynamic range, thus making it difficult to perform some basic experiments that need to directly compare strong and weak terahertz signals. Here, we propose and demonstrate a novel technique based on cross-polarized spectral-domain interferometry to achieve ultra-high dynamic range electro-optic sampling measurement of coherent millimeter and sub-millimeter radiation. In our scheme, we exploit the birefringence in a single-mode polarization maintaining fiber in order to measure the phase change induced by the electric field of terahertz radiation in the detection crystal. With our new technique, we have achieved a dynamic range of 7 × 10(6), which is 4 orders of magnitude higher than conventional electro-optic sampling techniques, while maintaining comparable signal-to-noise ratio. The present technique is foreseen to have great impact on experiments such as linear terahertz spectroscopy of optically thick materials (such as aqueous samples) and nonlinear terahertz spectroscopy, where the higher dynamic range is crucial for proper interpretation of experimentally obtained results.

11.
Opt Lett ; 38(15): 2705-7, 2013 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-23903117

RESUMO

In this work, we demonstrate self-referenced spectral domain interferometry for the electro-optic sampling of terahertz (THz) electric fields. This technique allows reduction of the phase noise of the measurement, thus increasing the signal-to-noise ratio (SNR). Using the proposed technique, we achieve a more than sixfold improvement in the SNR of the detected THz electric field.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA