Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Diagn Microbiol Infect Dis ; 90(4): 257-263, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29433999

RESUMO

This study evaluated the performance of the Altona Diagnostics RealStar® Adenovirus Research Use Only (RUO) real-time PCR reagents for HAdV quantitation in plasma samples from immunodeficient patients. The assay was linear from 2.30-9.17 log10 copies/mL (coefficient of determination; R2=0.998) with limits of detection and quantification of 2.19 log10 and 2.30 log10 copies/mL (>95% positivity rate), respectively. Assay precision was highly reproducible with coefficients of variance ranging from 0% to 4.7%. A comparison of 66 matched samples showed good agreement (R2=0.845) between the Altona and the reference laboratory assay, with an average negative bias (-0.24 log10 copies/mL). Genotyping analysis demonstrated that HAdV species B and C accounted for 77% of the positive samples. A significant (≥0.9 log10) difference in quantitation between both tests was found for three HAdV types (HAdV types A12, B14 and F41). In conclusion, the Altona RealStar® test is a reliable and sensitive assay for HAdV DNA quantitation.


Assuntos
Infecções por Adenovirus Humanos/virologia , Adenovírus Humanos/isolamento & purificação , Reação em Cadeia da Polimerase/métodos , Carga Viral/métodos , Adenovírus Humanos/genética , Humanos , Plasma/virologia , Estudos Prospectivos , Reprodutibilidade dos Testes
2.
Am J Clin Pathol ; 144(6): 909-15, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26572998

RESUMO

OBJECTIVES: Viral load testing for BK virus (BKV) has become the standard of care for diagnosing BKV infection and monitoring therapy in kidney transplant patients. However, there are currently no US Food and Drug Administration-approved assays and no standardization among available tests. METHODS: This study evaluated the performance of the analyte-specific reagent (ASR) BKV primers r-gene and probe r-gene reagents (bioMérieux, Marcy l'Étoile, France) soon to become available on the US market for accuracy, linearity, precision, analytical sensitivity, specificity, and correlation with the Qiagen (Germantown, MD) BKV ASR test using commercial material and patient plasma samples. RESULTS: The assay was linear from 204 to 3.92 million (2.31-6.6 log10) DNA copies/mL (coefficient of determination: R(2) =0.999). A dilution series demonstrated limits of detection and quantitation of 2.14 log10 and 2.30 log10 copies/mL (95% hit rate detection), respectively. Interrun precision was highly reproducible, with coefficients of variance ranging from 2.2% to 6.0%. A comparison of 34 matched samples showed a good agreement (R(2) = 0.87) between the bioMérieux BKV laboratory test and the Qiagen BKV ASR assay results, with an average negative bias (-0.28 log10 copies/mL). CONCLUSIONS: The laboratory-developed test with bioMérieux BKV reagents is a reliable and sensitive assay for BKV DNA quantitation compared with the Qiagen ASR test.


Assuntos
Vírus BK , DNA Viral/sangue , Infecções por Polyomavirus/diagnóstico , Humanos , Indicadores e Reagentes , Sensibilidade e Especificidade , Infecções Tumorais por Vírus/diagnóstico
3.
J Clin Virol ; 54(3): 260-4, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22494899

RESUMO

BACKGROUND: Viral load testing for BK Virus (BKV) has become the standard of care for the diagnosis of infection and monitoring of therapy of kidney transplant patients infected with BKV. However, there are currently no FDA-approved BKV quantification assays and no standardization among available tests. OBJECTIVE AND STUDY DESIGN: This study evaluated the performance of the Artus BK Virus RG PCR (RUO) assay (QIAGEN) for accuracy, linearity, precision, analytical sensitivity, specificity, and correlation with a referral laboratory test in patient samples. RESULTS: Linear regression analysis of the quantitative results demonstrated a linear range of quantification from 192 to 194 million (2.28 to 8.29 log(10)) DNA copies/mL and a coefficient of determination (R(2)) of 0.994. A dilution series demonstrated a limit of detection and a limit of quantification of 2.00 log(10), and 2.30 log(10) copies/mL (>95% positivity rate), respectively. The precision of the assay was highly reproducible among runs with coefficients of variance (CV) ranging from 0.2% to 7.0%. A comparison of 34 matched samples showed a good agreement (R(2)=0.983) between the Artus BK test and the referral laboratory results, with an average positive bias (0.39 log(10) copies/mL). Genotyping analysis using large-T antigen sequences demonstrated that 90% of the positive samples were BKV type I, and that there was no significant difference in quantification between the referral laboratory and Artus BK Virus tests. CONCLUSIONS: The Artus BK Virus RG PCR test is a reliable and sensitive assay for BKV DNA quantification as compared to the referral laboratory test.


Assuntos
Vírus BK/genética , Vírus BK/isolamento & purificação , Reação em Cadeia da Polimerase/métodos , Carga Viral/métodos , Monitoramento de Medicamentos/métodos , Humanos , Transplante de Rim/efeitos adversos , Infecções por Polyomavirus/diagnóstico , Infecções por Polyomavirus/virologia , Sensibilidade e Especificidade
4.
Jpn J Cancer Res ; 93(2): 151-6, 2002 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11856478

RESUMO

The significance of urokinase-type plasminogen activator (uPA) expression in gastric cancer development was tested by using a human uPA cDNA transfection approach and an in vivo severe combined immunodeficient (SCID) mouse model. The AGS gastric cancer cell line, which has urokinase-type plasminogen-activator receptor (uPAR) but lacks uPA, was transfected with a plasmid containing human uPA cDNA and injected into the backs of SCID mice. Compared with the parent AGS cells, uPA protein secretion in AGS-2-, AGS-4-, and AGS-8-transfected cells increased by 26.1-, 34.6-, and 4.8-fold, respectively (P < 0.05). mRNA expression levels of uPA in the AGS-4 clone were much stronger than those in AGS-2 and AGS-8 clones. After the cancer cells (2 x 10(6)) were injected s.c. into the SCID mice, a palpable mass was observed at the injection site at around 140 days post-injection, followed by accelerated growth of the xenograft up to 180 days post-injection only in the high uPA-producing clone (AGS-4). These results suggest that continuous and high production of uPA by tumor cells is one of the important factors reflecting the malignancy of gastric cancer cells.


Assuntos
Neoplasias Gástricas/enzimologia , Ativador de Plasminogênio Tipo Uroquinase/biossíntese , Animais , Humanos , Imuno-Histoquímica , Camundongos , Camundongos SCID , Neoplasias Gástricas/patologia , Transfecção , Células Tumorais Cultivadas , Ativador de Plasminogênio Tipo Uroquinase/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA