Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Medicine (Baltimore) ; 96(30): e7669, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28746233

RESUMO

Bleeding following cardiac surgery is a serious event with potentially life-threatening consequences. Preoperative recognition of coagulation abnormalities and detection of cardiopulmonary bypass (CPB) related coagulopathy could aid in the start of preventive treatment strategies that minimize perioperative blood loss. Most algorithms that analyze thromboelastometry coagulation tests in elective cardiac surgery do not include test results performed before surgery. We evaluated preoperative rotational thromboelastometry test results for their ability to predict blood loss during and after cardiac surgery.A total of 114 adult patients undergoing cardiac surgery with CPB were included in this retrospective analysis. Each patient had thromboelastometry tests done twice: preoperatively, before the induction of anesthesia and postoperatively, 10 minutes after heparin reversal with protamine after decannulation.Patients were placed into 1 of 2 groups depending on whether preoperative thromboelastometry parameters deviated from reference ranges: Group 1 [N = 29; extrinsically activated test (EXTEM) or INTEM results out of normal range] or Group 2 (N = 85; EXTEM and INTEM results within the normal range). We observed that the total amount of chest tube output was significantly greater in Group 1 than in Group 2 (700 mL vs 570 mL, P = .03). At the same time, the preoperative values of standard coagulation tests such as platelet count, aPTT, and INR did not indicate any abnormalities of coagulation.Preoperative coagulation abnormalities diagnosed with thromboelastometry can predict increased chest tube output in the early postoperative period in elective adult cardiac surgery. Monitoring of the coagulation system with thromboelastometry allows rapid diagnosis of coagulation abnormalities even before the start of the surgery. These abnormalities could not always be detected with routine coagulation tests.


Assuntos
Perda Sanguínea Cirúrgica , Ponte Cardiopulmonar , Tubos Torácicos , Hemorragia Pós-Operatória/diagnóstico , Cuidados Pré-Operatórios , Tromboelastografia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Prognóstico , Estudos Retrospectivos
2.
Anaesthesiol Intensive Ther ; 49(1): 34-39, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28362031

RESUMO

BACKGROUND: The automatic control module of end-tidal volatile agents (EtC) was designed to reduce the consumption of anaesthetic gases, increase the stability of general anaesthesia and reduce the need for adjustments in the settings of the anaesthesia machine. The aim of this study was to verify these hypotheses. METHODS: The course of general anaesthesia with the use of the EtC module was analysed for haemodynamic stability, depth of anaesthesia, end-expiratory concentration of anaesthetic, number of ventilator key presses, fentanyl supply, consumption of volatile agents and anaesthesia and operation times. These data were compared with the data obtained during general anaesthesia controlled manually and were processed with statistical tests. RESULTS: Seventy-four patients underwent general anaesthesia for scheduled operations. Group AUTO-ET (n = 35) was anaesthetized with EtC, and group MANUAL-ET (n = 39) was controlled manually. Both populations presented similar anaesthesia stability. No differences were noted in the time of anaesthesia, saturation up to MAC 1.0 or awakening. Data revealed no differences in mean EtAA or the fentanyl dose. The AUTO-ET group exhibited fewer key presses per minute, 0.0603 min⁻¹, whereas the MANUAL-ET exhibited a value of 0.0842 min⁻¹; P = 0.001. The automatic group consumed more anaesthetic and oxygen per minute (sevoflurane 0.1171 mL min⁻¹; IQR: 0.0503; oxygen 1.8286 mL min⁻¹, IQR: 1,3751) than MANUAL-ET (sevoflurane 0.0824 mL min⁻¹, IQR: 0.0305; oxygen 1,288 mL min⁻¹, IQR: 0,6517) (P = 0.0028 and P = 0.0171, respectively). CONCLUSION: Both methods are equally stable and safe for patients. The consumption of volatile agents was significantly increased in the AUTO-ET group. EtC considerably reduces the number of key presses.


Assuntos
Anestesia Geral/métodos , Anestesia por Inalação/métodos , Anestésicos Inalatórios/administração & dosagem , Éteres Metílicos/administração & dosagem , Adjuvantes Anestésicos/administração & dosagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fentanila/administração & dosagem , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Oxigênio/metabolismo , Sevoflurano
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA